Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
Adv Mater ; 36(16): e2307810, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38277680

RESUMEN

The need for the development of soft materials capable of stably adhering to nerve tissues without any suturing followed by additional damages is at the fore at a time when success in postoperative recovery depends largely on the surgical experience and/or specialized microsuturing skills of the surgeon. Despite fully recognizing such prerequisite conditions, designing the materials with robust adhesion to wet nerves as well as acute/chronic anti-inflammation remains to be resolved. Herein, a sticky and strain-gradient artificial epineurium (SSGAE) that overcomes the most critically challenging aspect for realizing sutureless repair of severely injured nerves is presented. In this regard, the SSGAE with a skin-inspired hierarchical structure entailing strain-gradient layers, anisotropic Janus layers including hydrophobic top and hydrophilic bottom surfaces, and synergistic self-healing capabilities enables immediate and stable neurorrhaphy in both rodent and nonhuman primate models, indicating that the bioinspired materials strategy significantly contributes to translational medicine for effective peripheral nerve repair.


Asunto(s)
Nervios Periféricos , Roedores , Animales , Nervios Periféricos/fisiología , Nervios Periféricos/cirugía , Primates , Regeneración Nerviosa
2.
Skeletal Radiol ; 52(8): 1485-1491, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36752828

RESUMEN

OBJECTIVE: The ulnar positive variance (UPV) can be observed on simple radiography due to a triangular fibrocartilage complex (TFCC) foveal tear. This study investigated to identify how much radiographic UPV occurs due to a TFCC foveal tear, which may be misdiagnosed as an ulnar impaction syndrome (UIS). MATERIALS AND METHODS: One hundred forty patients who underwent arthroscopic transosseus TFCC foveal repair from March 2013 to March 2019 in our institution were enrolled in this study. Ulnar variances were measured in preoperative, postoperative 6 weeks, 1-year follow-up wrist posteroanterior (PA) radiograph, and power grip PA radiograph of the affected wrist and were compared with those of the same patient's unaffected wrist. RESULTS: In the neutral wrist PA radiograph, ulnar variance increased by 0.56 mm (p < 0.001) after TFCC foveal tear compared to the unaffected side. In the power grip view, ulnar variance also increased by 0.39 mm (p < 0.001) in the affected wrist. The preoperative ulnar positive variance was reduced after an arthroscopic transosseous TFCC foveal repair from 0.56 to 0 mm (p < 0.001). No significant statistical difference was observed between an Atzei class 2 and 3 TFCC tear (0.56 mm vs. 0.41 mm, p = 0.263). CONCLUSION: This study revealed that TFCC foveal tear induces 0.56 mm of radiologic UPV, which was successfully corrected after arthroscopic transosseous TFCC foveal repair. Therefore, UPV associated with TFCC foveal tear should not be misdiagnosed as an UIS. Also, when ulnar shortening osteotomy is planned in case of UIS combined with TFCC foveal tear, the amount of UPV induced by TFCC foveal tear should be considered to prevent over-shortening.


Asunto(s)
Enfermedades de los Cartílagos , Artropatías , Fibrocartílago Triangular , Traumatismos de la Muñeca , Humanos , Artroscopía , Fibrocartílago Triangular/diagnóstico por imagen , Fibrocartílago Triangular/cirugía , Articulación de la Muñeca , Traumatismos de la Muñeca/diagnóstico por imagen , Traumatismos de la Muñeca/cirugía
3.
Clin Orthop Surg ; 14(4): 576-584, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36518941

RESUMEN

Background: Posterior inferior capsule (PIC) tightness in the shoulder joint, a known risk factor for shoulder injury, can be assessed using shear-wave ultrasound elastography (SWE). However, to date, the correlation between PIC elasticity and shoulder rotator muscle performance in college baseball players with glenohumeral internal rotation deficit (GIRD) has not been reported. This study aimed to analyze the differences in PIC elasticity measured using SWE and shoulder rotator muscle performance between male college baseball players with and without GIRD. Methods: Twenty-four male college baseball players participated in this study: 10 with GIRD (G group) vs. 14 without GIRD (NG group). PIC elasticity was measured using SWE in the lateral decubitus position. Shoulder rotator muscle performance tests were performed for the internal rotators (IRs) and external rotators (ERs) at an angular velocity of 180°/sec with 90° shoulder abduction using an isokinetic test device. Results: Mean PIC elasticity was significantly greater in the throwing shoulders of the G group than in those of the NG group (4.8 ± 1.2 kPa vs. 3.7 ± 1.2 kPa, p = 0.036). In the throwing shoulders of the G group, compared with those of the NG-group, the ER/IR ratio was significantly lower (35.7% ± 5.0% vs. 55.5% ± 6.2%, p < 0.001) and IR muscle strength was significantly greater (75.0 ± 7.6 Nm kg-1 × 100 vs. 55.7 ± 6.4 Nm kg-1 × 100, p = 0.002). The mean elasticity of the PIC showed a significant negative correlation with the ER/IR ratio in the throwing shoulders of the G group (r = -0.640, p = 0.046). Conclusions: Among the male college baseball players with GIRD, SWE could quantitatively assess PIC tightness, and an imbalance in shoulder rotator muscle strength was found in these baseball players. Therefore, clinicians and therapists need to focus on the restoration of shoulder rotator muscle imbalance in addition to improving internal rotation in these players.


Asunto(s)
Béisbol , Lesiones del Hombro , Articulación del Hombro , Masculino , Humanos , Béisbol/lesiones , Rango del Movimiento Articular/fisiología , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiología , Músculo Esquelético/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...