Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
5.
JTCVS Tech ; 21: 65-71, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37854815

RESUMEN

Objective: The use of transcatheter mitral valve repair (TMVr) devices is increasing in elderly and high-risk patients. However, the increasing number of patients with recurrent mitral regurgitation (MR) has confronted surgeons with the issue of how to explant the devices and whether the mitral valve should be repaired or replaced. The aim of the study is to summarize our clinical experience with the explantation of different TMVr devices and to provide alternative surgical techniques that can be performed in different clinical scenarios. Methods: A simulator system including a dummy valve representing native valves was used to create video documentation and to develop alternative surgical methods for clip explantation. Moreover, the clip explantation techniques were shown in 2 patients undergoing minimally-invasive mitral valve repair after a failed TMVr. Results: Alternative explantation techniques were described for each TMVr device; 2 techniques for MitraClip and 3 techniques for PASCAL (Precision Transcatheter Valve Repair System), which may be adjusted for each individual according to the underlying valve pathology and the degree of device encapsulation. The patients were discharged without residual MR and remained MR free at the follow-up. Conclusions: Transcatheter edge-to-edge repair devices can be surgically explanted without damaging the MV leaflets. Removal of each device may require a different technique tailored to the degree of device encapsulation and valve pathology. Increasing experience may facilitate repair in patients with recurrent MR after TMVr.

8.
Eur J Cardiothorac Surg ; 64(1)2023 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-37233202

RESUMEN

OBJECTIVES: Annuloplasty rings are routinely used in mitral valve repair (MVr). However, accurate annuloplasty ring size selection is essential to obtain a favourable outcome. Moreover, ring sizing can be challenging in some patients and is highly influenced by surgeons' experience. This study investigated the utility of three-dimensional mitral valve (3D-MV) reconstruction models to predict annuloplasty ring size for MVr. METHODS: A total of 150 patients undergoing minimally invasive MVr with annuloplasty ring due to Carpentier type II pathology and who were discharged with none/trace residual mitral regurgitation were included. 3D-MV reconstruction models were created with a semi-automated software package (4D MV Analysis) to quantitate mitral valve geometry. To predict the ring size, univariable and multivariable linear regression analyses were performed. RESULTS: Between 3D-MV reconstruction values and implanted ring sizes, the highest correlation coefficients were provided by commissural width (CW) (0.839; P < 0.001), intertrigonal distance (ITD) (0.796; P < 0.001), annulus area (0.782; P < 0.001), anterior mitral leaflet area (0.767; P < 0.001), anterior-posterior diameter (0.679; P < 0.001) and anterior mitral leaflet length (0.515; P < 0.001). In multivariable regression analysis, only CW and ITD were found to be independent predictors of annuloplasty ring size (R2 = 0.743; P < 0.001). The highest level of agreement was achieved with CW and ITD, and 76.6% of patients received a ring with no >1 ring size difference from the predicted ring sizes. CONCLUSIONS: 3D-MV reconstruction models can support surgeons in the decision-making process for annuloplasty ring sizing. The present study may be a first step towards accurate annuloplasty ring size prediction using multimodal machine learning decision support.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/patología , Procedimientos Quirúrgicos Cardíacos/métodos , Válvula Tricúspide/cirugía , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento
9.
Innovations (Phila) ; 18(3): 232-239, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37144727

RESUMEN

OBJECTIVE: Evidence determining the optimal treatment for cardiac tumors is rare. We report our midterm clinical outcome and patient characteristics of our series undergoing atrial tumor removal through a right lateral minithoracotomy (RLMT). METHODS: From 2015 to 2021, 51 patients underwent RLMT for atrial tumor extirpation. Patients receiving concomitant atrioventricular valvular, cryoablation, and/or patent foramen ovale closure surgery were included. Follow-up was performed using standardized questionnaires (mean: 1,041 ± 666 days). Follow-up involved any tumor recurrence, clinical symptoms, and any recurrent arterial embolization. Survival analysis was successfully achieved in all patients. RESULTS: Successful surgical resection was achieved in all patients. Mean cardiopulmonary bypass and cross-clamping times were 75 ± 36 and 41 ± 22 min, respectively. The most common tumor location was the left atrium (n = 42, 82.4%). Mean ventilation time was 12.74 ± 17.23 h, intensive care unit stay ranged from 1 to 1.9 days (median: 1 day). Nineteen patients (37.3%) received concomitant surgery. Histopathological analysis showed 38 myxoma (74.5%), 9 papillary fibroelastoma (17.6%), and 4 thrombus (7.8%). Thirty-day mortality was observed in 1 case (2%). One patient (2%) suffered a stroke postoperatively. No patient had a relapse of cardiac tumor. Three patients (9.7%) showed arterial embolization during follow-up. Thirteen follow-up patients (25.5%) were in New York Heart Association class ≤II. Overall survival was 90.2% at 2 years. CONCLUSIONS: A minimally invasive approach for benign atrial tumor resection is effective, safe, and reproducible. Of the atrial tumors, 74.5% were myxoma and 82% were located in the left atrium. A low 30-day mortality rate with no manifestation of recurrent intracardiac tumor was observed.


Asunto(s)
Fibrilación Atrial , Neoplasias Cardíacas , Mixoma , Humanos , Estudios de Seguimiento , Recurrencia Local de Neoplasia/epidemiología , Neoplasias Cardíacas/patología , Atrios Cardíacos/cirugía , Atrios Cardíacos/patología , Mixoma/cirugía , Resultado del Tratamiento , Procedimientos Quirúrgicos Mínimamente Invasivos
10.
Innovations (Phila) ; 17(6): 491-498, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36314445

RESUMEN

OBJECTIVE: Venous drainage is often problematic in minimally invasive cardiac surgery (MICS). Here, we describe our experience with a self-expandable stent cannula designed to optimize venous drainage. METHODS: The smart canula® was used in 58 consecutive patients undergoing MICS for mitral valve disease (n = 40), left atrial myxoma (n = 3), left ventricular outflow tract obstruction (n = 1), and aortic valve replacement via a right anterior minithoracotomy (n = 14) procedures. The venous cannula was placed under transesophageal echocardiography guidance to reach the superior vena cava. Vacuum-assisted venous drainage (between -20 and -35 mm Hg) was used to reach a target flow index of 2.2 L/min/m² at a core temperature of 34 °C using a goal-directed perfusion strategy aimed at a minimum DO2 of 272 mL/min/m2. Cardiopulmonary bypass (CPB) parameters were recorded, and hemolysis-related parameters were analyzed on postoperative days 1 to 7. RESULTS: Mean body surface area and median body mass index were 1.9 ± 0.2 m2 and 25.2 (23.4, 30.2) kg/m2. Mean CPB and median cross-clamping times were 107.7 ± 24.4 min and 64.5 (53, 75.8) min, and median CPB flow during cardioplegic arrest was 4 (3.6, 4.2) L/min (median cardiac index 2.1 [2, 2.2] L/min/m²). Venous drainage was considered sufficient by the surgeon in all cases, and insertion and removal were uncomplicated. Mean SvO2 during CPB was 80.2% ± 5.5%, and median peak lactate was 10 (8, 14) mg/dL, indicating sufficient perfusion. Mean venous negative drainage pressure during cross-clamping was 27.2 ± 12.3 mm Hg. Platelets dropped by 73.6 ± 37.5 K/µL, lactate dehydrogenase rose by 81.5 (44.3, 140.8) U/L, and leukocytes rose by 3.4 (2.2, 7.2) K/µL on postoperative day 1. CONCLUSIONS: The venous smart canula® allows for optimal venous drainage at low negative drainage pressures, facilitating sufficient perfusion in MICS.


Asunto(s)
Cánula , Procedimientos Quirúrgicos Cardíacos , Humanos , Vena Cava Superior/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Cateterismo , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Puente Cardiopulmonar/métodos
11.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-36069638

RESUMEN

OBJECTIVES: Analyses of fast-track (FT) processes demonstrated that low-risk cardiac surgical patients require minimal intensive care, with a low incidence of mortality or morbidity. We investigated perioperative factors and their association with fast-track failure (FTF) in a retrospective cohort study of patients undergoing minimally invasive mitral valve surgery. METHODS: Patients undergoing minimally invasive surgical mitral valve repair for Carpentier type I or type II mitral regurgitation between 2014 and 2020 were included in the study. The definition of FTF consisted of >10 h mechanical ventilation, >24 h intensive care unit stay, reintubation after extubation and re-admission to the intensive care unit. Multivariable logistic regression analysis enabled the identification of factors associated with FTF. RESULTS: In total, 491 patients were included in the study and were analysed. Two hundred and thirty-seven patients (48.3%) failed the FT protocol. Multivariable logistic regression analysis showed that a New York Heart Association classification ≥III [odds ratio (OR) 2.05; 95% confidence interval (CI) 1.38-3.08; P < 0.001], pre-existing chronic kidney disease (OR 2.03; 95% CI 1.14-3.70; P = 0.018), coronary artery disease (OR 1.90; 95% CI 1.13-3.23; P = 0.016), postoperative bleeding requiring surgical revision (OR 8.36; 95% CI 2.81-36.01; P < 0.001) and procedure time (OR 1.01; 95% CI 1.01-1.01; P < 0.001) were independently associated with FTF. CONCLUSIONS: Factors associated with FTF in patients with Carpentier type I and II pathologies undergoing minimally invasive mitral valve repair are a New York Heart Association classification III-IV at baseline, pre-existing chronic kidney disease and coronary artery disease. Postoperative bleeding requiring rethoracotomy and procedure time were also identified as important factors associated with failed FT.


Asunto(s)
Enfermedad de la Arteria Coronaria , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Insuficiencia Renal Crónica , Enfermedad de la Arteria Coronaria/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Tiempo de Internación , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Resultado del Tratamiento
12.
Front Cardiovasc Med ; 9: 960849, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36148056

RESUMEN

We report on a 72 years old male patient with recurrent heart failure hospitalizations caused by severe mitral regurgitation due to severe restriction of the posterior mitral leaflet treated with the transfemoral mitral valve replacement (TMVR) system Cardiovalve. Immediate interventional success was obtained resulting in a quick mobilization and discharge.

13.
Front Cardiovasc Med ; 9: 928740, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35935663

RESUMEN

Background: In most cases of transcatheter valve embolization and migration (TVEM), the embolized valve remains in the aorta after implantation of a second valve into the aortic root. There is little data on potential late complications such as valve thrombosis or aortic wall alterations by embolized valves. Aims: The aim of this study was to analyze the incidence of TVEM in a large cohort of patients undergoing transcatheter aortic valve implantation (TAVI) and to examine embolized valves by computed tomography (CT) late after TAVI. Methods: The patient database of our center was screened for cases of TVEM between July 2009 and July 2021. To identify risk factors, TVEM cases were compared to a cohort of 200 consecutive TAVI cases. Out of 35 surviving TVEM patients, ten patients underwent follow-up by echocardiography and CT. Results: 54 TVEM occurred in 3757 TAVI procedures, 46 cases were managed percutaneously. Horizontal aorta (odds ratio [OR] 7.51, 95% confidence interval [CI] 3.4-16.6, p < 0.001), implantation of a self-expanding valve (OR 4.63, 95% CI 2.2-9.7, p < 0.01) and a left ventricular ejection fraction < 40% (OR 2.94, 95% CI 1.1-7.3, p = 0.016) were identified as risk factors for TVEM. CT scans were performed on average 26.3 months after TAVI (range 2-84 months) and detected hypoattenuated leaflet thickening (HALT) in two patients as well as parts of the stent frame protruding into the aortic wall in three patients. Conclusion: TVEM represents a rare complication of TAVI. Follow up-CT detected no pathological findings requiring intervention.

14.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-35809065

RESUMEN

OBJECTIVES: A novel hybrid non-covered stent was developed to treat malperfusion and prevent aneurysm formation following hemiarch procedure for DeBakey I acute aortic dissection (AAD). The present analysis investigates the performance of the device in 100 consecutive implantations. METHODS: Between 2018 and 2021, 100 patients underwent surgical repair of DeBakey I AAD with implantation of a non-covered stent in the arch and descending aorta. The primary entry tear was located in the root or the ascending aorta. Clinical and imaging data were collected and analysed retrospectively. The endpoints of the study were 30-day mortality, neurological outcome and need of additional procedures due to postoperative malperfusion. Technical success was assessed in the first postoperative computed tomography in regard to the induction of false lumen thrombosis in the descending aorta. RESULTS: The median age was 61 (54-73) years. Preoperative malperfusion was present in 46 (46%) patients. The primary arterial cannulation strategy was the right axillary artery and an open distal anastomosis was performed in a median caudal circulatory arrest of 40 (34-52) min. In 48% of cases, a 55-40 tapered stent was implanted. The 30-day mortality was 18%, and the operation-related new postoperative neurological deficit was present in 8%. Technical success was achieved in 76% of patients. CONCLUSIONS: The novel non-covered stent can be safely applied to complement aortic repair with the hemiarch procedure for DeBakey I AAD. The expansion of the true lumen through the device may prevent postoperative malperfusion and induces positive vascular remodelling with the thrombosis of the false lumen.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Disección Aórtica/cirugía , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/métodos , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Resultado del Tratamiento
15.
Artículo en Inglés | MEDLINE | ID: mdl-35863058

RESUMEN

OBJECTIVES: The standard approach for minimally invasive cardiac surgery (MICS) for repair of the atrioventricular valves is a right lateral minithoracotomy. In this study, we report our experience with a periareolar endoscopic approach, which aims at an optimal cosmetic outcome while preserving optimal clinical outcomes. METHODS: All patients underwent periareolar endoscopic MICS using high-definition three-dimensional endoscopic visualization without additional rib-spreading. Patients presented with degenerative and/or functional mitral regurgitation. Patients undergoing concomitant tricuspid valve surgery, cryo-ablation, patent foramen ovale closure, left atrial appendage occlusion and/or left atrial myxoma extirpation were included. This descriptive article analysed the aesthetic and functional outcome of the periareolar scar using 5 most common and clinimetrically sound scar assessment scales. For statistical analysis of the scar assessment grading scales, box and whisker plots were calculated depicting median, interquartile range and high and low range data points. RESULTS: Median scar assessment scale scores for n = 100 male patients (response rate 100/109; 91.7%) were 2 [1, 4], 7.5 [6, 9], 11 [8, 14], 3 [2, 3] and 10 [9, 11] for the Vancouver scar scale, Manchester scar scale, patient scar assessment scale, Stony brook scar evaluation scale and Dermatology Quality of Life Index scale, respectively. Ninety-seven patients received mitral valve repair, 7 mitral valve replacement, whereas 5 had left atrial myxoma extirpation. Concomitant tricuspid annuloplasty, cryo-ablation, left atrial appendage occlusion and patent foramen ovale closure surgery were performed in 12, 29, 5 and 8 patients, respectively. Median procedure, cardiopulmonary bypass and cross-clamp times were 169.5 [154.3, 189.3], 111.5 [97, 127], and 68.5 [58.8, 81] min, respectively. CONCLUSIONS: Periareolar endoscopic MICS is safe and cosmetically appealing. It is feasible and allows for complex mitral valve repair, mitral valve replacement and concomitant surgery. Data from 5 scar assessment scales suggest that this technique delivers patient-satisfying results regarding functional and cosmetic outcomes.


Asunto(s)
Foramen Oval Permeable , Implantación de Prótesis de Válvulas Cardíacas , Mixoma , Cicatriz/diagnóstico por imagen , Cicatriz/etiología , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Calidad de Vida , Resultado del Tratamiento
16.
Artículo en Inglés | MEDLINE | ID: mdl-35713519

RESUMEN

OBJECTIVES: Although clinical experience with transcatheter mitral valve interventions is rapidly increasing, there is still a lack of evidence regarding surgical treatment options for the management of recurrent mitral regurgitation (MR). This study provides guidance for a minimally invasive surgical approach following failed transcatheter mitral valve repair, which is based on the underlying mitral valve (MV) pathology and the type of intervention. METHODS: A total of 46 patients who underwent minimally invasive MV surgery due to recurrent or residual MR after transcatheter edge-to-edge repair or direct interventional annuloplasty between October 2014 and March 2021 were included. RESULTS: The median age of the patients was 78 [interquartile range, 71-82] years and the EuroSCORE II was 4.41 [interquartile range, 2.66-6.55]. At the index procedure, edge-to-edge repair had been performed in 45 (97.8%) patients and direct annuloplasty in 1 patient. All patients with functional MR at the index procedure (n = 36) underwent MV replacement. Of the patients with degenerative MR (n = 10), 5 patients were eligible for MV repair after removal of the MitraClip. The 1-year survival following surgical treatment was 81.3% and 75.0% in patients with functional and degenerative MR, respectively. No residual MR greater than mild during follow-up was observed in patients who underwent MV repair. CONCLUSIONS: Minimally invasive surgery following failed transcatheter mitral valve repair is feasible and safe, with promising midterm survival. The surgical management should be tailored to the underlying valve pathology at the index procedure, the extent of damage of the MV leaflets and the type of previous intervention.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
17.
J Card Surg ; 37(8): 2466-2468, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35610730

RESUMEN

Improvementsin medical imaging and a steady increase in computing power are leading to new possibilities in the field of cardiovascular interventions. Interventions can be planned in advance in greater detail, even to the point of simulating procedures. Nevertheless, all techniques are at an early stage of development. It is of utmost importance that tools, especially if they can be used as decision support are intensively validated and their accuracy is demonstrated. In our commentary, we summarize current techniques for impprovements in planning and guiding of procedures, but also critically discuss the downsides of these techniques. Following the work of Kenichi and colleagues, we also discuss necessary steps in advancing new tools and techniques, particularly as they are used in routine clinical practice. We also discuss the role of artificial intelligence, which could play a crucial role in this context in the future.


Asunto(s)
Inteligencia Artificial , Realidad Virtual , Diagnóstico por Imagen , Humanos
18.
Surg Technol Int ; 412022 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-35623038

RESUMEN

Over the past few decades, the field of minimally invasive cardiac surgery has significantly broadened. Novel surgical and endovascular techniques have been developed for the treatment of aortic valve pathologies. Surgical aortic valve replacement (SAVR) through a right antero-lateral (mini-)thoracotomy (RALT) has gained approval due to its limited postoperative trauma, faster rehabilitation and sufficient pain control. Nevertheless, SAVR RALT has not been adopted by a significant proportion of cardiac surgeons, due, in part, to its technical complexity and steep learning curve. In this review, we discuss the data for minimally invasive aortic valve surgery and describe our operative technique for SAVR RALT.

19.
J Card Surg ; 37(6): 1749-1752, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35366352

RESUMEN

Mitral annular calcification (MAC) complicates the management of mitral valve (MV) disease, regardless of its etiology. Strategies to address MV surgery in MAC include two main options with their own pros and cons; respect and resect strategy. Here, we present a case of minimally-invasive MV repair with partial annuloplasty in the management of noncircumferential MAC with respect to strategy. This technique may be an alternative option for rescuing high-risk patients without extensive decalcification.


Asunto(s)
Calcinosis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/etiología , Calcinosis/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA