Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur J Radiol ; 115: 31-38, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31084756

RESUMEN

AIM: The aim of this paper is to present baseline imaging data and the improvement that was achieved by the participating centers after applying practice-specific interventions that were identified during the course of a multicentric multinational research coordinated project. INTRODUCTION: The incidence and mortality rates from breast cancer are rising worldwide and particularly rapidly across the countries with limited resources. Due to lack of awareness and screening options it is usually detected at a later stage. Breast cancer screening programs and even clinical services on breast cancer have been neglected in such countries particularly due to lack of available equipment, funds, organizational structure and quality criteria. MATERIALS AND METHODS: A harmonized form was designed in order to facilitate uniformity of data collection. Baseline data such as type of equipment, number of exams, type and number of biopsy procedures, stage of cancer at detection were collected from 10 centers (9 countries: Bosnia-Herzegovina, Costa Rica, Egypt, India, North Macedonia, Pakistan, Slovenia, Turkey, Uganda) were collected. Local practices were evaluated for good practice and specific interventions such as training of professionals and quality assurance programs were identified. The centers were asked to recapture the data after a 2-year period to identify the impact of the interventions. RESULTS: The data showed increase in the number of training of relevant professionals, positive changes in the mammography practice and image guided interventions. All the centers achieved higher levels of success in the implementation of the quality assurance procedures. CONCLUSION: The study has encountered different levels of breast imaging practice in terms of expertise, financial and human resources, infrastructure and awareness. The most common challenges were the lack of appropriate quality assurance programs and lack of trained skilled personnel and lack of high-quality equipment. The project was able to create higher levels of breast cancer awareness, collaboration amongst participating centers and professionals. It also improved quality, capability and expertise in breast imaging particularly in centers involved diagnostic imaging.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Detección Precoz del Cáncer/normas , Mamografía/normas , Atención a la Salud/normas , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Cooperación Internacional , Garantía de la Calidad de Atención de Salud , Mejoramiento de la Calidad
2.
Phys Med ; 48: 127-134, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29599081

RESUMEN

PURPOSE: The International Atomic Energy Agency (IAEA) through a Coordinated Research Project on "Enhancing Capacity for Early Detection and Diagnosis of Breast Cancer through Imaging", brought together a group of mammography radiologists, medical physicists and radiographers; to investigate current practices and improve procedures for the early detection of breast cancer by strengthening both the clinical and medical physics components. This paper addresses the medical physics component. METHODS: The countries that participated in the CRP were Bosnia and Herzegovina, Costa Rica, Egypt, India, Kenya, the Frmr. Yug. Rep. of Macedonia, Mexico, Nigeria, Pakistan, Philippines, Slovenia, Turkey, Uganda, United Kingdom and Zambia. Ten institutions participated using IAEA quality control protocols in 9 digital and 3 analogue mammography equipment. A spreadsheet for data collection was generated and distributed. Evaluation of image quality was done using TOR MAX and DMAM2 Gold phantoms. RESULTS: QC results for analogue equipment showed satisfactory results. QC tests performed on digital systems showed that improvements needed to be implemented, especially in thickness accuracy, signal difference to noise ratio (SDNR) values for achievable levels, uniformity and modulation transfer function (MTF). Mean glandular dose (MGD) was below international recommended levels for patient radiation protection. Evaluation of image quality by phantoms also indicated the need for improvement. CONCLUSIONS: Common activities facilitated improvement in mammography practice, including training of medical physicists in QC programs and infrastructure was improved and strengthened; networking among medical physicists and radiologists took place and was maintained over time. IAEA QC protocols provided a uniformed approach to QC measurements.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Detección Precoz del Cáncer , Agencias Internacionales , Colaboración Intersectorial , Relación Señal-Ruido
3.
J Clin Ultrasound ; 38(6): 328-31, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19902525

RESUMEN

We report the case of dicephalic conjoined twins discovered incidentally on a routine ultrasound at 24 weeks of gestation. There were 2 heads and a neck that fused with 1 thorax, but the spines continued all the way to the coccyx. The spines were connected medially by a fused rib, and laterally, there were ribs that went around the thorax in a more normal fashion. Antenatal ultrasound images are supplemented by postnatal photographs and x-rays.


Asunto(s)
Gemelos Siameses , Ultrasonografía Prenatal/métodos , Aborto Eugénico/métodos , Adulto , Cesárea , Femenino , Humanos , Hallazgos Incidentales , Masculino
4.
J Coll Physicians Surg Pak ; 16(12): 760-3, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17125634

RESUMEN

OBJECTIVE: To assess the role of hysterosalpingoscintigraphy (HSSG) in the evaluation of fallopian tube patency and function and compare the results with hysterosalpingography (HSG) and laparoscopy (LS). DESIGN: Cross-sectional study. PLACE AND DURATION OF STUDY: The study was conducted at Multan Institute of Nuclear Medicine and Radiotherapy (MINAR), Multan from August 2004 to February 2005. PATIENTS AND METHODS: HSSG was performed after instillation of 4mCi (148 MBq) 99mTechnetium-macroaggregated albumin (99mTc-MAA) in posterior vaginal fornix in 65 patients. Serial static images were acquired in supine position at 1 hour, 2 hours, 3 hours and, if needed, at 24 hours. The results were compared to the findings on LS and HSG. RESULTS: Out of 65 patients, 37 (56.9%) patients had bilateral blocked tubes, 17 (26.1%) patients had bilateral patent tubes, 6 (9.2%) patients had blocked left tube and 5 (7.1%) patients had blocked right tube. The calculated sensitivity, specificity, positive predicted value (PPV), negative predicted value (NPV) and accuracy for HSSG were 90%, 83%, 90% and 90% respectively. The agreement between HSSG and LS was found in 32 out of 35 patients and agreement between HSG and HSSG was found in 24 out of 30 patients. CONCLUSION: This simple procedure can delineate tubal physiology; in selected cases it can replace HSG and in others augment the information gathered by HSG. HSSG should be part of the infertility workup algorithm.


Asunto(s)
Trompas Uterinas/diagnóstico por imagen , Infertilidad Femenina/diagnóstico por imagen , Pruebas de Obstrucción de las Trompas Uterinas , Femenino , Humanos , Histerosalpingografía , Infertilidad Femenina/diagnóstico , Laparoscopía , Cintigrafía , Radiofármacos , Agregado de Albúmina Marcado con Tecnecio Tc 99m
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA