1.
J Cardiothorac Vasc Anesth ; 38(7): 1460-1466, 2024 Jul.
Article En | MEDLINE | ID: mdl-38580474

OBJECTIVES: This study aimed to evaluate the accuracy of identifying the true aortic valve (AV) annulus using 2-dimensional (2D) echocardiography, with the goal of highlighting potential misidentification issues in clinical practice. DESIGN: An observational study employing 3-dimensional (3D) datasets to generate 2D images of the AV annulus for analysis. SETTING: The study was conducted in an academic medical center. PARTICIPANTS: Three-dimensional transesophageal echocardiography datasets were obtained from 11 patients with normal AV and aortic root anatomies undergoing coronary artery bypass surgery. Attending anesthesiologists certified by the National Board of Echocardiography (NBE) were approached subsequently to participate in this study. INTERVENTIONS: Two images per patient were generated from 3D datasets, reflecting the mid-esophageal long-axis view of the AV, a true AV annulus image, and an off-axis image. A survey was distributed to NBE-certified perioperative echocardiographers across 12 academic institutions to identify the true AV annulus from these images. MEASUREMENTS AND MAIN RESULTS: The survey, completed by 45 qualified respondents, revealed a significant misidentification rate of the true AV annulus, with only 36.8% of responses correctly identifying it. The rate of correct identification varied across image sets, with 44.4% of participants unable to correctly identify any true AV annulus image. CONCLUSIONS: The study highlighted the limitations of 2D echocardiography in accurately identifying the true AV annulus in complex 3D structures like the aortic root. The findings suggest a need for greater reliance on advanced imaging modalities, such as 3D echocardiography, to improve accuracy in clinical practice.


Aortic Valve , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Echocardiography, Three-Dimensional/methods , Echocardiography, Three-Dimensional/standards , Echocardiography, Transesophageal/methods , Echocardiography, Transesophageal/standards , Male , Female , Aged , Middle Aged , Echocardiography/methods , Echocardiography/standards
2.
J Cardiothorac Vasc Anesth ; 38(5): 1251-1259, 2024 May.
Article En | MEDLINE | ID: mdl-38423884

New artificial intelligence tools have been developed that have implications for medical usage. Large language models (LLMs), such as the widely used ChatGPT developed by OpenAI, have not been explored in the context of anesthesiology education. Understanding the reliability of various publicly available LLMs for medical specialties could offer insight into their understanding of the physiology, pharmacology, and practical applications of anesthesiology. An exploratory prospective review was conducted using 3 commercially available LLMs--OpenAI's ChatGPT GPT-3.5 version (GPT-3.5), OpenAI's ChatGPT GPT-4 (GPT-4), and Google's Bard--on questions from a widely used anesthesia board examination review book. Of the 884 eligible questions, the overall correct answer rates were 47.9% for GPT-3.5, 69.4% for GPT-4, and 45.2% for Bard. GPT-4 exhibited significantly higher performance than both GPT-3.5 and Bard (p = 0.001 and p < 0.001, respectively). None of the LLMs met the criteria required to secure American Board of Anesthesiology certification, according to the 70% passing score approximation. GPT-4 significantly outperformed GPT-3.5 and Bard in terms of overall performance, but lacked consistency in providing explanations that aligned with scientific and medical consensus. Although GPT-4 shows promise, current LLMs are not sufficiently advanced to answer anesthesiology board examination questions with passing success. Further iterations and domain-specific training may enhance their utility in medical education.


Anesthesiology , Humans , Artificial Intelligence , Prospective Studies , Reproducibility of Results , Language
3.
J Cardiothorac Vasc Anesth ; 38(3): 755-770, 2024 Mar.
Article En | MEDLINE | ID: mdl-38220517

OBJECTIVES: To investigate whether implementation of a multidisciplinary protocol for ruptured abdominal aortic aneurysm (rAAA) management reduces rates of adverse complications. DESIGN: A retrospective before-after study. SETTING: A tertiary-care academic hospital. PARTICIPANTS: Adult patients who underwent open or endovascular rAAA repair; data were stratified into before-protocol implementation (group 1: 2015-2018) and after-protocol implementation (group 2: 2019-2022) groups. INTERVENTION: The protocol details the workflow for vascular surgery, anesthesia, emergency department, and operating room staff for a rAAA case; training was accomplished through yearly workshops. MEASUREMENTS AND MAIN RESULTS: The primary outcome was in-hospital mortality. Secondary outcomes included all-cause morbidity and other major complications. Differences in postoperative complication rates between groups were assessed using Pearson's χ2 test. Of the 77 patients included undergoing rAAA repair, 41 (53.2%) patients were in group 1, and 36 (46.8%) patients were in group 2. Patients in group 2 had a significantly shorter median time to incision (1.0 v 0.7 hours, p = 0.022) and total procedure time (180.0 v 160.5 minutes, p = 0.039) for both endovascular and open repair. After protocol implementation, patients undergoing endovascular repair exhibited significantly lower rates of mortality (46.2% v 20.0%, p = 0.048), all-cause morbidity (65.4% v 44.0%, p = 0.050), and renal complications (15.4% v 0.0%, p = 0.036); patients undergoing open repair for a rAAA exhibited significantly lower rates of mortality (53.3% v 27.3%, p = 0.018) and bowel ischemia (26.7% v 0.0%, p = 0.035). CONCLUSIONS: Implementation of a multidisciplinary protocol for the management of a rAAA may reduce rates of adverse complications and improve the quality of care.


Aortic Aneurysm, Abdominal , Aortic Rupture , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Retrospective Studies , Controlled Before-After Studies , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/methods , Treatment Outcome , Aortic Rupture/surgery , Postoperative Complications/etiology , Risk Factors
4.
Echocardiography ; 41(1): e15709, 2024 Jan.
Article En | MEDLINE | ID: mdl-37922229

Double orifice mitral valve is a rare congenital anomaly that is often associated with other congenital cardiac abnormalities. Patients may present with valvular dysfunction or may be asymptomatic and have an incidental diagnosis of double outlet mitral valve. Whether symptoms due to this pathology are present or not it is important to accurately characterize this lesion. Three-dimensional imaging is a powerful diagnostic modality for diagnosing and characterizing lesions such as this as highlighted in this case image series where we describe how three-dimensional transesophageal echocardiography was utilized to characterize both complete and incomplete bridge type double orifice mitral valve.


Echocardiography, Three-Dimensional , Heart Defects, Congenital , Heart Valve Diseases , Humans , Mitral Valve , Echocardiography, Transesophageal , Heart Defects, Congenital/diagnosis
5.
J Cardiothorac Vasc Anesth ; 37(10): 2090-2097, 2023 10.
Article En | MEDLINE | ID: mdl-37422335

Invasive procedures are associated with adverse events that are both hazardous to patients and expensive to treat. A trainee is expected to perform complex sterile invasive procedures in a dynamic environment under time pressure while maintaining patient safety at the highest standard of care. For mastery in performing an invasive procedure, the automatism of the technical aspects is required, as well as the ability to adapt to patient conditions, anatomic variability, and environmental stressors. Virtual reality (VR) simulation training is an immersive technology with immense potential for medical training, potentially enhancing clinical proficiency and improving patient safety. Virtual reality can project near-realistic environments onto a head-mounted display, allowing users to simulate and interact with various scenarios. Virtual reality has been used extensively for task training in various healthcare-related disciplines and other fields, such as the military. These scenarios often incorporate haptic feedback for the simulation of physical touch and audio and visual stimuli. In this manuscript, the authors have presented a historical review, the current status, and the potential application of VR simulation training for invasive procedures. They specifically explore a VR training module for central venous access as a prototype for invasive procedure training to describe the advantages and limitations of this evolving technology.


Simulation Training , Virtual Reality , Humans , Computer Simulation , Simulation Training/methods
6.
J Cardiothorac Vasc Anesth ; 37(9): 1813-1818, 2023 09.
Article En | MEDLINE | ID: mdl-37296022

Simulation-based training is an essential component in the education of transthoracic echocardiography (TTE). Nevertheless, current TTE teaching methods may be subject to certain limitations. Hence, the authors in this study aimed to invent a novel TTE training system employing three-dimensional (3D) printing technology to teach the basic principles and psychomotor skills of TTE imaging more intuitively and understandably. This training system comprises a 3D-printed ultrasound probe simulator and a sliceable heart model. The probe simulator incorporates a linear laser generator to enable the visualization of the projection of the ultrasound scan plane in a 3D space. By using the probe simulator in conjunction with the sliceable heart model or other commercially available anatomic models, trainees can attain a more comprehensive understanding of probe motion and related scan planes in TTE. Notably, the 3D-printed models are portable and low-cost, suggesting their potential utility in various clinical scenarios, particularly for just-in-time training.


Echocardiography , Heart , Humans , Echocardiography/methods , Ultrasonography , Heart/diagnostic imaging , Models, Anatomic , Printing, Three-Dimensional
7.
J Coll Physicians Surg Pak ; 29(1): 70-72, 2019 Jan.
Article En | MEDLINE | ID: mdl-30630574

Replacement of aortic valve with the pulmonary autograft is carried out through the Ross procedure due to its potential for growth, durability in pediatric population, and absence of anticoagulation. This case series reports the postoperative outcome of two technical variations of Ross procedure in eight patients who underwent surgery from January 2007 to December 2016. The dominant valvular hemodynamic indication was aortic regurgitation. The techniques employed for Ross procedure included free standing root replacement in six patients and modified root replacement with autograft stabilisation using Dacron interposition graft in two patients. Right ventricular outflow tract (RVOT) conduit reconstruction was achieved by utilisation of Contegra bio prosthesis in four patients; and use of manually constructed valved conduit comprising of PTFE (polytetrafluoroethelene) membrane and bovine pericardial tube in remaining four patients. There was no mortality and no re-intervention. The technical varieties of Ross procedure offer freedom from need of anti-coagulation, mortality, and RVOT conduit failure in younger adults.


Aortic Valve/surgery , Bioprosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Pulmonary Artery/transplantation , Ventricular Outflow Obstruction/surgery , Adolescent , Adult , Blood Vessel Prosthesis Implantation/adverse effects , Child , Female , Heart Valve Diseases/surgery , Humans , Male , Transplantation, Homologous , Treatment Outcome
...