Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
JTCVS Open ; 15: 211-219, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37808015

RESUMEN

Objective: In patients with ischemic cardiomyopathy, coronary artery bypass grafting ensures better survival than medical therapy. However, the long-term clinical impact of complete revascularization remains unclear. This observational study aimed to evaluate the effects of complete revascularization on long-term survival and left ventricular functional recovery in patients with ischemic cardiomyopathy undergoing coronary artery bypass grafting. Methods: We retrospectively reviewed outcomes of 498 patients with ischemic cardiomyopathy who underwent complete (n = 386) or incomplete (n = 112) myocardial revascularization between 1993 and 2015. The baseline characteristics were adjusted using inverse probability of treatment weighting to reduce the impact of treatment bias and potential confounding. The mean follow-up duration was 77.2 ± 42.8 months in survivors. Results: The overall 5-year survival rate (complete revascularization, 72.5% vs incomplete revascularization, 57.9%, P = .03) and freedom from all-cause death and/or readmission due to heart failure (54.5% vs 40.1%, P = .007) were significantly greater in patients with complete revascularization than those with incomplete revascularization. After adjustments using inverse probability of treatment weighting, the complete revascularization group demonstrated a lower risk of all-cause death (hazard ratio, 0.61; 95% confidence interval, 0.43-0.86; P = .005) and composite adverse events (hazard ratio, 0.59; 95% confidence interval, 0.44-0.79; P < .001) and a greater improvement in the left ventricular ejection fraction 1-year postoperatively (absolute change: 11.0 ± 11.9% vs 8.3 ± 11.4%, interaction effect P = .05) than the incomplete revascularization group. Conclusions: In patients with ischemic cardiomyopathy undergoing coronary artery bypass grafting, complete revascularization was associated with better long-term outcomes and greater left ventricular functional recovery and should be encouraged whenever possible.

2.
Eur Heart J Case Rep ; 7(9): ytad459, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37743897

RESUMEN

Background: Bicuspid aortic valve (BAV) with displacement of the attachment of the conjoined aortic leaflet and fibrous strands is a rare cardiac malformation. We report a case of BAV that presented as acute massive aortic regurgitation during cardiopulmonary bypass for a planned non-valve-related procedure and was successfully treated by emergency aortic valve replacement. Case summary: A 70-year-old man with triple vessel coronary disease and severe left ventricular systolic dysfunction underwent coronary bypass grafting and graft replacement of the ascending aorta. Acute aortic regurgitation occurred during ventricular fibrillation and after de-clamping of the aortic graft. Intra-operative findings included a fused BAV (right-left cusp fusion), very asymmetrical leaflet (commissure angle of the non-fused leaflet 135°), three aortic sinuses, and conjoined leaflets originating from the myocardium in the inter-ventricular septum. The aortic leaflets were resected and replaced with a prosthetic aortic valve at the attachment site of the conjoined leaflets. Post-operatively, no peri-valvular leaks were observed, and left ventricular function was improved. Discussion: Intra-operative acute massive aortic regurgitation may be caused by a morphologically abnormal aortic leaflet and root complex in patients with a BAV. The dilated aortic root, asymmetrical leaflet, and abnormal aortic leaflet insertion, with thick septal myocardium of the coronary aortic sinus, might have caused unstable leaflet co-aptation, leading to deformation of the aortic leaflets influenced by the change in myocardial tone and intra-operative change in the sinotubular junction. Familiarity with the classification of congenital BAV, and the anatomy of the normal and abnormal aortic root complex, is important.

3.
Am J Case Rep ; 24: e940291, 2023 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-37401051

RESUMEN

BACKGROUND Cardiac perforation is a rare complication of cardiac implantable electronic devices, with a reported incidence ranging from 0.1% to 5.2%. Delayed perforation, defined as perforation occurring more than 1 month after implantation, is more uncommon. In this report, we present a case of cardiac perforation involving the right ventricle wall that occurred 9 years after pacemaker implantation. CASE REPORT A 79-year-old woman presented with symptoms of dyspnea and was subsequently admitted to a hospital. She had undergone pacemaker implantation for a complete atrioventricular block 9 years prior to the presentation. The patient had right ventricular failure to capture and a resultant complete atrioventricular block. Computed tomography imaging revealed that the right ventricular lead had clearly protruded outside the heart; however, no pericardial effusion was observed. When the patient underwent open surgical repair, the ventricular tined lead was noted to be traversing the right ventricular apex. Device interrogation revealed a sudden increase followed by a gradual decrease in the right ventricular pacing threshold over the course of 2 months, indicating that the lead had slowly traversed the right ventricular muscle before ultimately rupturing through it. CONCLUSIONS This study described the case of a delayed right ventricular pacemaker lead perforation that occurred 9 years after implantation, which was managed via open surgical repair.


Asunto(s)
Bloqueo Atrioventricular , Lesiones Cardíacas , Marcapaso Artificial , Derrame Pericárdico , Femenino , Humanos , Anciano , Ventrículos Cardíacos/cirugía , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/complicaciones , Marcapaso Artificial/efectos adversos , Derrame Pericárdico/etiología , Lesiones Cardíacas/cirugía , Lesiones Cardíacas/complicaciones
4.
Circ J ; 85(11): 1991-2001, 2021 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-33828021

RESUMEN

BACKGROUND: In patients with severe left ventricular (LV) dysfunction requiring coronary artery bypass grafting (CABG), the association between diabetic status and outcomes after surgery, as well as with survival benefit following bilateral internal thoracic artery (ITA) grafting, remain largely unknown.Methods and Results:Patients (n=188; mean [±SD] age 67±9 years) with LV ejection fraction ≤40% who underwent isolated initial CABG were classified into non-diabetic (n=64), non-insulin-dependent diabetic (NIDM; n=74), and insulin-dependent diabetic (IDM; n=50) groups. During follow-up (mean [±SD] 68±47 months), the 5-year survival rate was 84% and 65% among non-diabetic and diabetic patients, respectively (P=0.034). After adjusting for all covariates, both NIDM and IDM were associated with increased mortality, with hazard ratios (HRs) of 1.9 (95% confidence interval [CI] 1.0-3.7; P=0.049) and 2.4 (95% CI 1.2-4.8; P=0.016), respectively. Among non-diabetic patients, there was no difference in the 5-year survival rate between single and bilateral ITA grafting (86% vs. 80%, respectively; P=0.95), whereas bilateral ITA grafting increased survival among diabetic patients (57% vs. 81%; P=0.004). Multivariate analysis revealed that bilateral ITA was significantly associated with a decreased risk of mortality (HR 0.3; 95% CI 0.1-0.8; P=0.024). CONCLUSIONS: NIDM and IDM were significantly associated with worse long-term clinical outcome after CABG for severe LV dysfunction. Bilateral ITA grafting has the potential to improve survival in diabetic patients with severe LV dysfunction.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Arterias Mamarias , Disfunción Ventricular Izquierda , Anciano , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Disfunción Ventricular Izquierda/cirugía
5.
Intern Med ; 60(16): 2627-2631, 2021 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-33678745

RESUMEN

We herein report the case of a 79-year-old man who presented with right-sided heart failure (HF) 27 years after undergoing surgery for tetralogy of Fallot. The HF did not respond well to oral diuretics. Transthoracic echocardiography and chest X-ray failed to determine the cause of the HF for three years. An intrapericardial mass located just behind the sternum, was finally identified on computed tomography. The mass had compressed the right ventricle, causing right-sided HF. Pre-surgical diagnostic images led to suspicion of a chronic expanding intrapericardial hematoma (CEIH), and the CEIH was surgically removed. The patient's symptoms improved markedly.


Asunto(s)
Insuficiencia Cardíaca , Tetralogía de Fallot , Anciano , Ecocardiografía , Insuficiencia Cardíaca/etiología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Hematoma/diagnóstico por imagen , Hematoma/etiología , Hematoma/cirugía , Humanos , Masculino , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía
6.
Ann Thorac Surg ; 112(6): 1909-1920, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33545152

RESUMEN

BACKGROUND: Consensus regarding an optimal atrial fibrillation (AF) ablation lesion set concomitant with aortic valve replacement (AVR) and/or coronary artery bypass grafting (CABG) has not been established. METHODS: We enrolled 125 consecutive patients (89 men; 70 ± 8 years old) with persistent AF who underwent radiofrequency-based pulmonary vein isolation (PVI) (PVI group, n = 53) or a Cox-Maze procedure (Maze group, n = 72) with AVR and/or CABG. To reduce the impact of treatment bias and potential confounding in the direct comparisons between patients who underwent Cox-Maze with and those who underwent PVI, we established weighted Cox proportional-hazards regression models with inverse probability of treatment weighting. Mean follow-up was 63 ± 34 months (maximum, 154 months). RESULTS: There was 1 in-hospital death in each group. Patients who underwent Cox-Maze showed a higher freedom from AF at all follow-up examinations. After the operation, there were 32 deaths, 13 thromboembolisms, 8 hemorrhagic events, and 22 heart failure readmissions. The Maze group had higher rates for 5-year survival (88% vs 64%, P = .013) and freedom from composite events (74% vs 42%, P < .001). After adjustment with inverse probability of treatment weighting, the Cox-Maze procedure still showed a lower risk of overall mortality (adjusted hazard ratio, 0.38; 95% confidence interval, 0.21-0.66; P = .001) and composite adverse events (adjusted hazard ratio, 0.52; 95% confidence interval, 0.35-0.76; P = .001). CONCLUSIONS: In patients with persistent AF indicated for nonmitral valve surgery, a concomitant Cox-Maze procedure resulted in superior AF- and event-free survival compared with PVI, without increased risk of early mortality. These findings may assist decision making for surgical management of persistent AF concomitant with AVR and/or CABG.


Asunto(s)
Válvula Aórtica/cirugía , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Fibrilación Atrial/complicaciones , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/complicaciones , Mortalidad Hospitalaria/tendencias , Humanos , Japón/epidemiología , Masculino , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
7.
Eur J Cardiothorac Surg ; 58(4): 832-838, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32968791

RESUMEN

OBJECTIVES: Although concomitant surgery for coronary artery disease (CAD) and thoracic aortic aneurysm is performed often, the long-term patency of the coronary artery bypass grafting (CABG) anastomosed to a vascular prosthesis has not been fully investigated. Here, we explored the long-term patency of the graft in comparison with the proximal anastomosis site on the native ascending aorta or vascular prosthesis. METHODS: A total of 84 patients with concomitant CABG who underwent surgery for thoracic aortic aneurysm at 3 Osaka Cardiovascular Research Group institutes were retrospectively investigated for this study. The patency of 109 aortocoronary bypasses using saphenous vein grafts was evaluated with computed tomography angiography or coronary angiography, comparing the grafts anastomosed on the vascular prosthesis (group P, n = 75) to those anastomosed on the native ascending aorta (group N, n = 34). RESULTS: During 45.9 ± 39.7 months follow-up, significantly worse patency of the grafts in group P was revealed when compared with those in group N (100% vs 77.6% in 12 months, 100% vs 52.7% in 36 months and 100% vs 31.6% in 57 months, log rank P < 0.001). The poor patency of the grafts was confirmed in each target lesions (left anterior descending artery: P = 0.050, right coronary artery: P = 0.045, left circumflex artery: P = 0.051) and regardless of the severities of the target coronary vessels (severe stenosis: P = 0.013, mild-to-moderate stenosis: P = 0.029). Furthermore, an analysis of graft occlusion risk factors using the univariate Cox proportional hazards model revealed that the proximal anastomosis site on the vascular prosthesis was the sole risk factor for graft occlusion (P < 0.001). CONCLUSIONS: In the simultaneous surgery for CAD and thoracic aortic aneurysm, CABG design from vascular prosthesis to coronary artery should be avoided if possible, although further studies are warranted.


Asunto(s)
Prótesis Vascular , Oclusión de Injerto Vascular , Angiografía Coronaria , Puente de Arteria Coronaria , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/cirugía , Humanos , Estudios Retrospectivos , Vena Safena/diagnóstico por imagen , Vena Safena/cirugía , Resultado del Tratamiento , Grado de Desobstrucción Vascular
8.
Ann Vasc Surg ; 64: 116-123, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31629849

RESUMEN

BACKGROUND: Although endovascular repair (EVAR) is the first-line treatment for abdominal aortic aneurysm, type 2 endoleak (EL), which is associated with late sac enlargement or rupture, remains a concern. The present study aimed to assess the influence of type 2 EL on long-term outcomes after EVAR. METHODS: Among 550 patients who underwent EVAR between 2007 and 2013 at 14 Japanese national hospitals, 135 patients had type 2 EL diagnosed on follow-up computed tomography (CT) within 12 months after EVAR (EL2[+] group) and 415 patients did not have EL within 12 months (EL2[-] group). The cumulative incidences of sac enlargement, late intervention, and aneurysm-related death after EVAR were estimated using the cumulative incidence function method, and prognostic factors were investigated using the Fine-Gray hazard model. RESULTS: The median follow-up period was 5 years, and the 5-year cumulative incidence rates of sac enlargement, late intervention, and aneurysm-related death were 30.7% ± 4.4%, 25.3% ± 4.1%, and 2.6% ± 1.4%, respectively, in the EL2(+) group, and 8.7% ± 1.6%, 7.6% ± 1.4%, and 0.3% ± 0.3%, respectively, in the EL2(-) group. The cumulative incidence rates of sac enlargement (P = 0.002), late intervention (P < 0.001), and aneurysm-related death (P = 0.015) were significantly different between the 2 groups. As the first-line treatment for sac enlargement with type 2 EL, transcatheter coil embolization was performed in 30 patients. Information about sac behavior on CT after coil embolization was available in 20 of the 30 patients. Among these patients, no patients experienced sac shrinkage, and the aneurysmal sac dilated after coil embolization in 18 patients. CONCLUSIONS: Type 2 EL affects the long-term outcomes after EVAR. It is not recommended to observe large aneurysmal sacs conservatively as they tend to dilate in the presence of type 2 EL.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Endofuga/epidemiología , Procedimientos Endovasculares/efectos adversos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/mortalidad , Embolización Terapéutica , Endofuga/diagnóstico por imagen , Endofuga/mortalidad , Endofuga/terapia , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Incidencia , Japón/epidemiología , Masculino , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
9.
Ann Thorac Surg ; 108(2): 481-490, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30914284

RESUMEN

BACKGROUND: A successful endovascular treatment for acute type A dissection has been recently reported. However, there has been no consensus regarding the appropriate stent graft size based on the estimated predissected aortic diameter for this pathology. METHODS: We developed new equations for estimating the predissected ascending aorta and aortic arch by investigating computed tomography images that had been scanned less than 3 years before dissection. From 684 patients with type A AAD, 28 were matched for the study. We measured the predissected whole circumference length (pre-wCL), postdissected whole circumference length (post-wCL), postdissected true lumen circumference length (post-tCL), postdissected major diameter (post-Dma), and postdissected minor diameter (post-Dmi) of the acutely dissected aorta. This was followed by the calculation of (post-tCL + post-wCL)/2 and (post-Dma + post-Dmi)/2. Six equations (linear function) and modified equations were derived from each of the abovementioned parameters. RESULTS: Four equations (post-wCL, post-Dma, [post-tCL + post-wCL]/2, and [post-Dma + post-Dmi]/2) had nearly the same bias and accuracy (<9.42 mm). For clinical use, we also developed one modified equation using the post-wCL (y = 0.9x) among four parameters because of its simplicity and decreased the possibility of measurement error. The biases of circumference length and accuracy were 5.5 ± 4.9 mm and 84.6%, respectively, and they improved to 4.4 ± 3.3 mm and 93.4% in cases with a ratio of post-tCL/post-wCL of 0.66 or more. CONCLUSIONS: Our newly developed equation can be used to calculate the predissected ascending aortic diameter and aortic arch diameter in cases of acute type A dissection.


Asunto(s)
Algoritmos , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico , Disección Aórtica/diagnóstico , Procedimientos Endovasculares/métodos , Stents , Enfermedad Aguda , Anciano , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Angiografía por Tomografía Computarizada , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
J Thorac Cardiovasc Surg ; 155(3): 1021-1029.e5, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28992971

RESUMEN

BACKGROUND: Although diabetes mellitus (DM) increases the incidence of infective endocarditis (IE), little is known about the outcome of valve surgery for active IE in patients with DM. We evaluated the clinical outcomes of valve surgery for IE in patients with DM. METHODS: Between 2009 and 2016, 470 patients underwent valve surgery for definitive left-sided active IE at 12 affiliated hospitals. We compared the preoperative variables and clinical outcomes between patients without (n = 374) and with DM (n = 96). RESULTS: Staphylococcus and chronic hemodialysis were more prevalent in patients with DM, and these patients had greater preoperative inflammation levels and worse renal function than patients without DM. In-hospital mortality was 8% in patients without DM and 13% in patients with DM (P = .187). The overall survival rate at 1 and 5 years was 87% and 81% in patients without DM and 72% and 59% in patients with DM (P < .001). The incidence of infection-related death was greater in patients with DM than in patients without DM (P < .001; hazard ratio 3.74 [1.78-7.71]). Freedom from the recurrence of endocarditis at 1 and 5 years postoperatively was 98% and 95% in patients without DM, and 89% and 78% in patients with DM (P < .001), respectively. The Cox hazard analysis revealed that the presence of DM was the only independent risk for recurrence (hazard ratio 3.74 [1.45-9.54], P = .007). CONCLUSIONS: The short- and mid-term outcome after valve surgery for active IE in patients with DM is worse because of the greater prevalence of infection-related death and IE recurrence.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/mortalidad , Diabetes Mellitus/mortalidad , Endocarditis/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Diabetes Mellitus/diagnóstico , Endocarditis/diagnóstico , Endocarditis/mortalidad , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Supervivencia sin Progresión , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
11.
Int J Surg Case Rep ; 35: 21-24, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28427001

RESUMEN

INTRODUCTION: Traumatic blunt cardiac injuries have a high mortality rate, and prompt diagnosis and treatment can be lifesaving in cardiac tamponade. PRESENTATION OF CASE: A 62-year-old man was transferred to the emergency department after a motor vehicle accident. He was hemodynamically unstable. A focused assessment with sonography in trauma (FAST) showed pericardial fluid with right ventricular collapse consistent with cardiac tamponade in the subxiphoid view. He collapsed despite a subxiphoid pericardiotomy. Owing to the ongoing hemodynamic instability, we performed a left anterolateral thoracotomy. Direct incision of the pericardium showed blood and clots within the pericardial space, indicating hemopericardium. The heart stroke and hemodynamic status recovered on removing the clot. DISCUSSION: Although the physical findings of cardiac tamponade are not always apparent in life-threatening acute cardiac tamponade after blunt trauma, FAST is a reliable tool for diagnosing and following cardiac tamponade. A median sternotomy is a standard approach for evaluating cardiac injury in hemodynamically stable patients with or without cardiopulmonary bypass. However, a left anterior thoracotomy was the fastest, simplest life-saving procedure considering the need for open-chest cardiac massage given our patient's life-threatening condition. CONCLUSION: A prompt diagnosis using FAST and treatment can be lifesaving in traumatic acute cardiac tamponade. A pericardiotomy via a thoracotomy is mandatory for lifesaving cardiac decompression in acute traumatic cardiac tamponade in cases of ineffective drainage due to clot formation within the pericardial space.

12.
Gen Thorac Cardiovasc Surg ; 65(2): 110-116, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27645146

RESUMEN

OBJECTIVE: To identify the predictive factors for responders to tolvaptan, a novel vasopressin type 2 receptor antagonist for fluid management after cardiovascular surgery. METHODS: Between January 2013 and May 2014, 113 patients were treated with tolvaptan for fluid management after cardiovascular surgery. As indicators for the effects of tolvaptan, change in bodyweight during the tolvaptan administration period and correlations with perioperative factors were assessed. Thirty-one patients were administered tolvaptan at the first day after surgery (early tolvaptan group). In this group, urine volume during the 6 h before the initial tolvaptan administration was compared with that at 6 h after administration. RESULTS: For all the patients, the change in bodyweight during the tolvaptan administration period significantly correlated with pre-operative serum creatinine (r = 0.19, p = 0.04) and albumin levels before tolvaptan administration (r = -0.29, p = 0.002). In the early tolvaptan group, the ratio of urine volume at 6 h before and 6 h after the initial tolvaptan administration significantly correlated with the pre-operative serum creatinine level (r = 0.43, p = 0.02), the serum albumin level before tolvaptan administration (r = -0.50, p = 0.004), and change in bodyweight (r = 0.38, p = 0.03). CONCLUSIONS: In patients undergoing cardiovascular surgery, deteriorating renal function, increased bodyweight, and hypoalbuminemia were found to be predictive factors for responders to tolvaptan for postoperative fluid management.


Asunto(s)
Benzazepinas/administración & dosificación , Procedimientos Quirúrgicos Cardiovasculares , Fluidoterapia/métodos , Cuidados Posoperatorios/métodos , Complicaciones Posoperatorias/tratamiento farmacológico , Anciano , Antagonistas de los Receptores de Hormonas Antidiuréticas/administración & dosificación , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Tolvaptán , Resultado del Tratamiento
14.
Ann Vasc Dis ; 9(2): 102-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27375803

RESUMEN

BACKGROUND: Sac behavior after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAAs) is considered as a surrogate for the risk of late rupture. The purpose of the study is to assess the sac behavior of AAAs after EVAR. METHODS AND RESULTS: Late sac enlargement (LSE) (≥5 mm) and late sac shrinkage (LSS) (≥5 mm) were analyzed in 589 consecutive patients who were registered at 14 national centers in Japan. The proportions of patients who had LSE at 1, 3 and 5 years were 2.6% ± 0.7%, 10.0% ± 1.6% and 19.0% ± 2.9%. The proportions of patients who had LSS at 1, 3 and 5 years were 50.1% ± 0.7%, 59.2% ± 2.3% and 61.7% ± 2.7%. Multiple logistic regression analysis identified two variables as a risk factor for LSE; persistent endoleak (Odds ratio 9.56 (4.84-19.49), P <0.001) and low platelet count (Odds ratio 0.92 (0.86-0.99), P = 0.0224). The leading cause of endoleak in patients with LSE was type II. CONCLUSIONS: The incidence of LSE is not negligible over 5 year period. Patients with persistent endoleak and/or low platelet count should carefully be observed for LSE. CLINICAL TRIAL REGISTRATION: UMIN-CTR (UMIN000008345).

15.
BMC Res Notes ; 8: 183, 2015 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-25935638

RESUMEN

BACKGROUND: To report a technique of keeping unilateral blood flow in the internal iliac artery in cases of an abdominal aortic aneurysm in achieving successful Endovascular abdominal aortic aneurysm repair using an external-to-internal artery bypass. CASE PRESENTATION: 6 japanese patients with infra-renal abdominal aortic aneurysms were treated using the retroperitoneal approach via a left (right) paramedian incision followed by an external-to-internal artery bypass. Endovascular abdominal aortic aneurysm repair was conducted on mean postoperative day 29 ± 18 and was performed because the contralateral internal iliac artery, which was not involved in the external-to-internal artery bypass, was treated with a coil embolization. No complications developed during the postoperative follow-up period (17 ± 1.5 months). In all 6 patients, patent grafts were evident on computed tomography angiography scans even after 1-3 months. CONCLUSIONS: Endovascular abdominal aortic aneurysm repair with unilateral internal iliac artery embolization and contralateral external-to-internal artery bypass is feasible with a relatively low risk. It is a safe procedure and reduces the incidence of postoperative complications.


Asunto(s)
Puente de Arteria Coronaria/métodos , Procedimientos Endovasculares/métodos , Arteria Ilíaca/cirugía , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/patología , Aneurisma de la Aorta Abdominal/cirugía , Femenino , Estudios de Seguimiento , Humanos , Arteria Ilíaca/diagnóstico por imagen , Masculino , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
16.
Eur J Cardiothorac Surg ; 48(5): 765-77; discussion 777, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25612746

RESUMEN

OBJECTIVES: Left atrial (LA) dimension can predict atrial fibrillation (AF) recurrence after catheter-based or surgical ablation. Pulmonary vein isolation (PVI) may be a surgical option during aortic valve replacement (AVR) and/or coronary artery bypass grafting (CABG), though consensus regarding patient selection and late outcome is lacking. METHODS: We studied 160 patients (mean age 70 ± 9 years) with paroxysmal AF who underwent radiofrequency-based PVI during AVR and/or CABG, and were followed up postoperatively for at least 6 months. Mean preoperative LA dimension was 44 ± 7 mm. Serial echocardiography was performed to evaluate left ventricular (LV) and LA dimensions, E/e', estimated systolic pulmonary artery (PA) pressure and degree of valvular regurgitation. Follow-up was completed with a mean duration of 47 ± 25 months. RESULTS: At the latest follow-up, 133 patients (83%) remained in sinus rhythm. Preoperative LA dimension was independently associated with increased risk of AF recurrence at 6 months after surgery [adjusted odds ratio 1.3 per 1-mm increase in LA dimension, 95% confidence interval (CI) 1.1-1.6, P < 0.001]. Receiver-operating characteristic curve analysis demonstrated an optimal cut-off value for preoperative LA dimension of 45 mm to predict sinus rhythm restoration (98% for <45 mm vs 55% for ≥45 mm, P < 0.001). Patients with LA dimension ≥45 mm had a significantly lower 5-year survival rate (62 ± 7 vs 82 ± 7%, P = 0.025) and freedom from adverse events defined as cerebral infarction/haemorrhage, admission for heart failure, catheter ablation and permanent pacemaker implantation (58 ± 7 vs 91 ± 4%, P < 0.001). Multivariate analysis showed that preoperative LA dimension ≥45 mm was independently associated with adverse events (adjusted hazards ratio 2.4, 95% CI 1.2-5.1, P = 0.019). Serial echocardiography demonstrated improvement in LV systolic function irrespective of LA dimension, whereas patients with LA dimension ≥45 mm showed less improvement in LA dimension and systolic PA pressure (interaction effect P < 0.001) and persistent higher E/e' (group effect P < 0.001), along with aggravated tricuspid regurgitation. CONCLUSIONS: In patients with paroxysmal AF related to aortic valve disease and/or coronary artery disease, a dilated left atrium (≥45 mm) was associated with inferior AF- and event-free survival after PVI, accompanied by persistent abnormalities in cardiac and haemodynamic function. These findings may assist patient selection for PVI during AVR and/or CABG.


Asunto(s)
Fibrilación Atrial/etiología , Puente de Arteria Coronaria/efectos adversos , Atrios Cardíacos/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Curva ROC , Estudios Retrospectivos , Resultado del Tratamiento
17.
Surg Today ; 44(12): 2388-91, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24496979

RESUMEN

Congenital quadricuspid aortic valve is a rare cardiac malformation with an unknown risk of infective endocarditis. We report a case of quadricuspid aortic valve complicated with infective endocarditis. A 53-year-old Japanese woman was hospitalized with leg edema and a fever of unknown origin. Corynebacterium striatum was detected in the blood culture. Echocardiography demonstrated a quadricuspid aortic valve with vegetation and severe functional regurgitation. The condition was diagnosed as a quadricuspid aortic valve with infective endocarditis, for which surgery was performed. The quadricuspid aortic valve had three equal-sized cusps and one smaller cusp (type B according to Hurwitz classification). We dissected the vegetation and infectious focus and implanted a mechanical valve. Following the case report, we review the literature.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Endocarditis/etiología , Endocarditis/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Aórtica/etiología , Infecciones por Corynebacterium , Endocarditis/diagnóstico , Endocarditis/microbiología , Femenino , Prótesis Valvulares Cardíacas , Humanos , Persona de Mediana Edad , Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
18.
Ann Vasc Surg ; 27(6): 802.e5-7, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23535526

RESUMEN

A 39-year-old man with a thoracic aortic aneurysm and pseudocoarctation underwent graft replacement of the distal arch. The left subclavian artery, which rose just after the aneurysm, was also reconstructed at surgery. The aneurysmal wall was extremely thin, and the adventitia and a small amount of medial tissue were found on histologic examination. Thus, surgical treatment was recommended due to risk of rupture. Furthermore, because aneurysms involved the cervical branch, separate reconstruction was also performed. Endovascular intervention is not appropriate for this group of patients because of the complex kinking of the aorta and the extremely thin aneurysmal wall.


Asunto(s)
Aneurisma de la Aorta Torácica/complicaciones , Coartación Aórtica/complicaciones , Arteria Subclavia , Procedimientos Quirúrgicos Vasculares/métodos , Adulto , Aneurisma/complicaciones , Aneurisma/diagnóstico por imagen , Aneurisma/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía , Humanos , Imagenología Tridimensional , Masculino , Tomografía Computarizada por Rayos X
19.
Heart Vessels ; 28(6): 769-74, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23160858

RESUMEN

Prosthesis-patient mismatch (PPM) is always of concern when performing aortic valve replacement (AVR) in patients with a small aortic annulus. Although bioprosthetic AVR is preferred in patients older than 65 years, we have experienced cases in elderly patients with a small aortic annulus whereby we could not implant small-sized bioprosthetic valves. We have implanted St. Jude Medical Regent (SJMR) mechanical valves (St. Jude Medical, St. Paul, MN, USA) as necessary, even in elderly patients with no aortic annulus enlargement. We investigated our experiences of AVR with SJMR mechanical valves of 21 mm or less in size. Between January 2006 and December 2009, 40 patients underwent AVR with SJMR mechanical valves ≤21 mm in size: 9 patients received 21-mm valves, 19 received 19-mm valves, and 12 received 17-mm valves. The mean age was 65.9 ± 9.5 years, and 25 patients (62.5 %) were 65 years or older. We evaluated the clinical outcome and the echocardiographic data for each valve size. There was no operative or hospital mortality. The mean duration of clinical follow-up was 31.2 ± 17.6 months. During follow-up, there were no hospitalizations due to heart failure. The cumulative valve-related event-free survival was 93 % at 33 months, and the cumulative hemorrhagic event-free survival was 93 % at 33 months and 84 % at 43 months, using the Kaplan-Meier method. At follow-up, the mean values of the measured effective orifice area (EOA) for the 21-, 19-, and 17-mm prostheses were 2.00 ± 0.22, 1.74 ± 0.37, and 1.25 ± 0.26 cm(2), and the mean measured EOA index (EOAI) were 1.17 ± 0.12, 1.11 ± 0.21 and 0.90 ± 0.22 cm(2)/m(2), respectively. A PPM (EOAI ≤0.85) was documented in 5 patients, all of whom had received a 17-mm SJMR valve. AVR with SJMR valves of 21 mm or less in size appears to show satisfactory clinical and hemodynamic results.


Asunto(s)
Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Supervivencia sin Enfermedad , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía
20.
Osaka City Med J ; 58(1): 39-44, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23094513

RESUMEN

Pericardial effusion and cardiac tamponade are often refractory and difficult to manage. The transthoracic pericardial fenestration which create a window is the conventional procedure for releasing pericardial effusion to the thoracic cavity. We experienced two cases of pericardial fenestration. The first case was a patient with hypertrophic cardiomyopathy with pericardial effusion. She had a thoracic compression fracture, which indicated pericardial fenestration before an orthopedic surgery. The second case was a patient with recurrent cardiac tamponade caused by postpericardiotomy syndrome after off-pump coronary artery bypass grafting. In both cases, the patients underwent left anterior thoracotomy of about 10 cm at the level of the 5th intercostal space. The pericardium was incised within a radius of about 20 mm; furthermore, the fenestrated window was opened to the left thoracic cavity. In this paper, we present our experience of pericardial fenestration and discuss a review of the literature.


Asunto(s)
Derrame Pericárdico/cirugía , Técnicas de Ventana Pericárdica , Anciano , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA