Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Express ; 31(21): 33930-33944, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37859162

RESUMEN

Spatial-mode demultiplexing (SPADE) has recently been adopted to measure the separation in the transverse plane between two incoherent point-like sources with sub-wavelength separation. It has been argued that this approach may yield extraordinary performances in the photon-counting regime. Here, we explore SPADE as a tool for precision measurements in the regime of bright, incoherent sources. First we analyze the general problem of estimating the second moments of the source's intensity distribution, for an extended incoherent source of any shape. Our theory predicts a substantial improvement in signal-to-noise ratio (SNR) of SPADE over direct imaging in the sub-wavelength regime. Second, we present an experimental application of SPADE to the case of two point-like, bright sources. We demonstrate the use of this setup for the estimation of the transverse separation and for the estimation of the relative intensity, confirming the expected improvement in SNR.

2.
Nat Commun ; 13(1): 7016, 2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36385118

RESUMEN

By reducing both the internal and translational temperature of any species down to a few kelvins, the buffer-gas-cooling (BGC) technique has the potential to dramatically improve the quality of ro-vibrational molecular spectra, thus offering unique opportunities for transition frequency measurements with unprecedented accuracy. However, the difficulty in integrating metrological-grade spectroscopic tools into bulky cryogenic equipment has hitherto prevented from approaching the kHz level even in the best cases. Here, we overcome this drawback by an original opto-mechanical scheme which, effectively coupling a Lamb-dip saturated-absorption cavity ring-down spectrometer to a BGC source, allows us to determine the absolute frequency of the acetylene (ν1 + ν3) R(1)e transition at 6561.0941 cm-1 with a fractional uncertainty as low as 6 × 10-12. By improving the previous record with buffer-gas-cooled molecules by one order of magnitude, our approach paves the way for a number of ultra-precise low-temperature spectroscopic studies, aimed at both fundamental Physics tests and optimized laser cooling strategies.

3.
Materials (Basel) ; 15(4)2022 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-35208053

RESUMEN

Time-resolved photoluminescence (TRPL) analysis is often performed to assess the qualitative features of semiconductor crystals using predetermined functions (e.g., double- or multi-exponentials) to fit the decays of PL intensity. However, in many cases-including the notable case of interband PL in direct gap semiconductors-this approach just provides phenomenological parameters and not fundamental physical quantities. In the present work, we highlight that within a properly chosen range of laser excitation, the TRPL of zinc oxide (ZnO) bulk crystals can be described with excellent precision with second-order kinetics for the total recombination rate. We show that this allows us to define an original method for data analysis, based on evaluating the "instantaneous" recombination rate that drives the initial slope of the decay curves, acquired as a function of the excitation laser fluence. The method is used to fit experimental data, determining useful information on fundamental quantities that appear in the second-order recombination rate, namely the PL (unimolecular) lifetime, the bimolecular recombination coefficient, the non-radiative lifetime and the equilibrium free-carrier concentration. Results reasonably close to those typically obtained in direct gap semiconductors are extracted. The method may represent a useful tool for gaining insight into the recombination processes of a charge carrier in ZnO, and for obtaining quantitative information on ZnO excitonic dynamics.

4.
Int J Mol Sci ; 22(1)2020 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-33383699

RESUMEN

We review the recent developments in precision ro-vibrational spectroscopy of buffer-gas-cooled neutral molecules, obtained using infrared frequency combs either as direct probe sources or as ultra-accurate optical rulers. In particular, we show how coherent broadband spectroscopy of complex molecules especially benefits from drastic simplification of the spectra brought about by cooling of internal temperatures. Moreover, cooling the translational motion allows longer light-molecule interaction times and hence reduced transit-time broadening effects, crucial for high-precision spectroscopy on simple molecules. In this respect, we report on the progress of absolute frequency metrology experiments with buffer-gas-cooled molecules, focusing on the advanced technologies that led to record measurements with acetylene. Finally, we briefly discuss the prospects for further improving the ultimate accuracy of the spectroscopic frequency measurement.


Asunto(s)
Acetileno/química , Modelos Teóricos , Espectrofotometría Infrarroja , Algoritmos
5.
Sci Rep ; 7(1): 15168, 2017 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-29123171

RESUMEN

We present a detection scheme to search for QCD axion dark matter, that is based on a direct interaction between axions and electrons explicitly predicted by DFSZ axion models. The local axion dark matter field shall drive transitions between Zeeman-split atomic levels separated by the axion rest mass energy m a c 2. Axion-related excitations are then detected with an upconversion scheme involving a pump laser that converts the absorbed axion energy (~hundreds of µeV) to visible or infrared photons, where single photon detection is an established technique. The proposed scheme involves rare-earth ions doped into solid-state crystalline materials, and the optical transitions take place between energy levels of 4f N electron configuration. Beyond discussing theoretical aspects and requirements to achieve a cosmologically relevant sensitivity, especially in terms of spectroscopic material properties, we experimentally investigate backgrounds due to the pump laser at temperatures in the range 1.9 - 4.2 K. Our results rule out excitation of the upper Zeeman component of the ground state by laser-related heating effects, and are of some help in optimizing activated material parameters to suppress the multiphonon-assisted Stokes fluorescence.

6.
Opt Lett ; 42(10): 1911-1914, 2017 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-28504757

RESUMEN

We report on absolute measurements of saturated-absorption line-center frequencies of room-temperature trifluoromethane using a quantum cascade laser at 8.6 µm and the frequency modulation spectroscopy method. Absolute calibration of the laser frequency is obtained by direct comparison with a mid-infrared optical frequency comb synthesizer referenced to a radio-frequency Rb standard. Several sub-Doppler transitions falling in the υ5 vibrational band are investigated at around 1158.9 cm-1 with a fractional frequency precision of 8.6·10-12 at 1-s integration time, limited by the Rb-clock stability. The demonstrated frequency uncertainty of 6.6·10-11 is mainly limited by the reproducibility of the frequency measurements.

7.
Phys Chem Chem Phys ; 18(25): 16715-20, 2016 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-27273337

RESUMEN

We demonstrate continuous-wave cavity ring-down spectroscopy of a partially hydrodynamic molecular beam emerging from a buffer-gas-cooling source. Specifically, the (ν1 + ν3) vibrational overtone band of acetylene (C2H2) around 1.5 µm is accessed using a narrow-linewidth diode laser stabilized against a GPS-disciplined rubidium clock via an optical frequency comb synthesizer. As an example, the absolute frequency of the R(1) component is measured with a fractional accuracy of ∼1 × 10(-9). Our approach represents the first step towards the extension of more sophisticated cavity-enhanced interrogation schemes, including saturated absorption cavity ring-down or two-photon excitation, to buffer-gas-cooled molecular beams.

8.
J Chem Phys ; 143(23): 234202, 2015 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-26696053

RESUMEN

We report a high-precision spectroscopic study of room-temperature trifluoromethane around 8.6 µm, using a CW quantum cascade laser phase-locked to a mid-infrared optical frequency comb. This latter is generated by a nonlinear down-conversion process starting from a dual-branch Er:fiber laser and is stabilized against a GPS-disciplined rubidium clock. By tuning the comb repetition frequency, several transitions falling in the υ5 vibrational band are recorded with a frequency resolution of 20 kHz. Due to the very dense spectra, a special multiple-line fitting code, involving a Voigt profile, is developed for data analysis. The combination of the adopted experimental approach and survey procedure leads to fractional accuracy levels in the determination of line center frequencies, down to 2 × 10(-10). Line intensity factors, pressure broadening, and shifting parameters are also provided.

9.
Opt Express ; 21(12): 14618-26, 2013 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-23787649

RESUMEN

We report a thorough analysis of the spectral properties of an ytterbium-doped fibre amplifier, seeded by a Nd:YAG laser, whose linewidth has been narrowed down to 1 Hz by locking the laser to an ultrastable reference cavity. We measured the phase noise contribution from the amplifier, showing that it does not depend on the amplification gain, nor on the seed laser linewidth. Moreover, the amplifier-induced phase noise does not affect the final linewidth, as verified by heterodyne linewidth measurement within the 0.2 Hz resolution bandwidth of our acquisition set-up. Preservation of spectral purity below Hz-level is promising for more demanding applications, from nonlinear optics to frequency/time-standard transfer over fibre links.


Asunto(s)
Amplificadores Electrónicos , Artefactos , Tecnología de Fibra Óptica/instrumentación , Láseres de Estado Sólido , Diseño de Equipo , Análisis de Falla de Equipo , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...