Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Phys Chem B ; 123(17): 3832-3840, 2019 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-30958003

RESUMEN

Collective self-motion of particulate systems provides novel opportunities for developing flocking and sensing functions from seemingly inanimate objects. In this paper, we report videos documenting spontaneous collective flocking of multiple irregularly shaped macroscopic benzoquinone (BQ) particles at the air-water interface. Self-propulsion occurs due to the Gibbs-Marangoni effect surface tension gradients generated by the BQ particles. The air-water interface develops inhomogeneous interfacial tension fields created by differential dissolution at points and edges of BQ particles, causing interfacial tension variations along the solid-liquid-air interfaces. Responses of irregularly shaped BQ particles to these driving forces do not result in random motion but lead to a cooperative hydrodynamic flocking. Curiously, the flocking behavior was very evident for irregularly shaped particles but not observed for symmetric circular BQ disks. The flock responds to changes in its local environment as it forages for interfacial free energy. It exhibits warm and cool thermotaxis and thus can sense local temperature changes. Also, though a single magnetic bead is not confined to a part of the Petri dish by an applied magnetic field, when this magnetic bead is a member of a flock in which all of the other beads are not magnetic, the flock as a whole moves and hovers around the region where the field is maximum. In other words, the magnetic bead becomes a kind of "sensor" for the flock to respond to a magnetic field, the response being a drift in the direction of the field.

2.
Analyst ; 143(22): 5505-5511, 2018 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-30295303

RESUMEN

We report a low-cost, sensitive, bead-based electrochemical immunoarray for soluble L-selectin (or CD62L protein), a potential biomarker for staging bladder cancer. We used a semi-automated modular microfluidic array with online antigen capture on superparamagnetic beads, which were subsequently delivered to a detection chamber housing multiple sensors. The assay was designed to accurately detect CD62L in diluted serum with a limit of detection (LOD) of 0.25 ng mL-1 and a dynamic range of 0.25-100 ng mL-1. The microfluidic array gave significantly better accuracy and higher sensitivity than a standard ELISA kit, which was shown to be subject to significant systematic error at high and low concentration ranges. 31 serum samples from patients with varying grades of bladder cancer and cancer-free controls were analyzed by the immunoarray and ELISA, and the CD62L levels correlated. This work establishes a new accurate assay for determining CD62L levels and highlights the potential of this protein as a biomarker for detecting locoregional progression of bladder cancer.


Asunto(s)
Biomarcadores de Tumor/sangre , Selectina L/sangre , Neoplasias de la Vejiga Urinaria/sangre , Animales , Bovinos , Técnicas Electroquímicas/métodos , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Límite de Detección , Técnicas Analíticas Microfluídicas/métodos
3.
Nanotechnology ; 27(28): 284002, 2016 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-27250897

RESUMEN

While 3D printing technologies first appeared in the 1980s, prohibitive costs, limited materials, and the relatively small number of commercially available printers confined applications mainly to prototyping for manufacturing purposes. As technologies, printer cost, materials, and accessibility continue to improve, 3D printing has found widespread implementation in research and development in many disciplines due to ease-of-use and relatively fast design-to-object workflow. Several 3D printing techniques have been used to prepare devices such as milli- and microfluidic flow cells for analyses of cells and biomolecules as well as interfaces that enable bioanalytical measurements using cellphones. This review focuses on preparation and applications of 3D-printed bioanalytical devices.


Asunto(s)
Impresión Tridimensional , Microfluídica
4.
ACS Sens ; 1(2): 197-202, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27135052

RESUMEN

Clear plastic fluidic devices with ports for incorporating electrodes to enable electrochemiluminescence (ECL) measurements were prepared using a low-cost, desktop three-dimensional (3D) printer based on stereolithography. Electrodes consisted of 0.5 mm pencil graphite rods and 0.5 mm silver wires inserted into commercially available 1/4 in.-28 threaded fittings. A bioimaging system equipped with a CCD camera was used to measure ECL generated at electrodes and small arrays using 0.2 M phosphate buffer solutions containing tris(2,2'-bipyridyl)dichlororuthenium(II) hexahydrate ([Ru(bpy)3]2+) with 100 mM tri-n-propylamine (TPA) as the coreactant. ECL signals produced at pencil graphite working electrodes were linear with respect to [Ru(bpy)3]2+ concentration for 9-900 µM [Ru(bpy)3]2+. The detection limit was found to be 7 µM using the CCD camera with exposure time set at 10 s. Electrode-to-electrode ECL signals varied by ±7.5%. Device performance was further evaluated using pencil graphite electrodes coated with multilayer poly(diallyldimethylammonium chloride) (PDDA)/DNA films. In these experiments, ECL resulted from the reaction of [Ru(bpy)3]3+ with guanines of DNA. ECL produced at these thin-film electrodes was linear with respect to [Ru(bpy)3]2+ concentration from 180 to 800 µM. These studies provide the first demonstration of ECL measurements obtained using a 3D-printed closed-channel fluidic device platform. The affordable, high-resolution 3D printer used in these studies enables easy, fast, and adaptable prototyping of fluidic devices capable of incorporating electrodes for measuring ECL.

5.
Biosens Bioelectron ; 77: 188-93, 2016 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-26406460

RESUMEN

Herein we report a low cost, sensitive, supercapacitor-powered electrochemiluminescent (ECL) protein immunoarray fabricated by an inexpensive 3-dimensional (3D) printer. The immunosensor detects three cancer biomarker proteins in serum within 35 min. The 3D-printed device employs hand screen printed carbon sensors with gravity flow for sample/reagent delivery and washing. Prostate cancer biomarker proteins, prostate specific antigen (PSA), prostate specific membrane antigen (PSMA) and platelet factor-4 (PF-4) in serum were captured on the antibody-coated carbon sensors followed by delivery of detection-antibody-coated Ru(bpy)3(2+) (RuBPY)-doped silica nanoparticles in a sandwich immunoassay. ECL light was initiated from RuBPY in the silica nanoparticles by electrochemical oxidation with tripropylamine (TPrA) co-reactant using supercapacitor power and ECL was captured with a CCD camera. The supercapacitor was rapidly photo-recharged between assays using an inexpensive solar cell. Detection limits were 300-500f gmL(-1) for the 3 proteins in undiluted calf serum. Assays of 6 prostate cancer patient serum samples gave good correlation with conventional single protein ELISAs. This technology could provide sensitive onsite cancer diagnostic tests in resource-limited settings with the need for only moderate-level training.


Asunto(s)
Conductometría/instrumentación , Suministros de Energía Eléctrica , Inmunoensayo/instrumentación , Mediciones Luminiscentes/instrumentación , Impresión Tridimensional , Análisis por Matrices de Proteínas/instrumentación , Capacidad Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Phys Chem Chem Phys ; 17(44): 29891-8, 2015 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-26488440

RESUMEN

Self-motion of physical-chemical systems is a promising avenue for studying and developing mechanical functions with inanimate systems. In this paper, we investigate spontaneous motion of collections of solid macroscopic benzoquinone (BQ) disks at the air-water interface without intervention of chemical reactions. The BQ particles slowly dissolve and create heterogeneous interfacial tension fields on the water surface that drive the motion. Spontaneous, continuous locomotion was observed between multiple BQ particles, along with coupling, collisions, cycling and collective foraging for interfacial free energy. Analysis of the motion suggests co-operative behavior depends strongly on particle shape.


Asunto(s)
Aire , Benzoquinonas/química , Agua , Solubilidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA