Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
JACC Cardiovasc Interv ; 16(23): 2900-2914, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38092496

RESUMEN

BACKGROUND: There is a scarcity of published head-to-head comparisons between different paclitaxel-coated angioplasty balloons. More prospective safety data to support the health care economic reimbursement processes are needed. OBJECTIVES: The aim of this study was to report the safety and efficacy of the Passeo-18 Lux drug-coated balloon (DCB) (Biotronik AG) for the treatment of symptomatic peripheral artery disease caused by stenosis, restenosis, or occlusion of the femoral and/or popliteal arteries. METHODS: A total of 302 patients were randomized 1:1 and assigned to the Passeo-18 Lux DCB (study device) group or the IN.PACT Admiral DCB (control device, Medtronic Vascular) group for testing of noninferiority. The primary efficacy endpoint was freedom from clinically driven target lesion revascularization at 12 months. The primary safety endpoint was a composite of freedom from device-/procedure-related death through 30 days postindex procedure, major target limb amputation, and clinically driven target vessel revascularization at 12 months. RESULTS: At 12 months, 130 of 134 patients in the IN.PACT Admiral group had freedom from clinically driven target lesion revascularization (97.0%) compared with 137 of 141 patients in the Passeo-18 Lux group (97.2%). The primary safety endpoint showed 96.3% in the control group vs 95.7% in the study device group. The null hypothesis of inferiority on both efficacy and safety was rejected. The Kaplan-Meier estimate of primary patency at 1 year was 88.7% in the control arm vs 91.5% in the study device arm. CONCLUSIONS: The Passeo-18 Lux and the IN.PACT Admiral DCBs demonstrate comparable results with excellent effectiveness and safety through 12 months for femoropopliteal interventions.


Asunto(s)
Angioplastia de Balón , Enfermedad Arterial Periférica , Humanos , Arteria Femoral/diagnóstico por imagen , Resultado del Tratamiento , Paclitaxel/efectos adversos , Estudios Prospectivos , Materiales Biocompatibles Revestidos , Factores de Tiempo , Arteria Poplítea/diagnóstico por imagen , Angioplastia de Balón/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Grado de Desobstrucción Vascular
2.
Expert Rev Med Devices ; 20(9): 715-720, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37486180

RESUMEN

INTRODUCTION: Radial access is the standard of care for nearly all cardiac catheterization procedures. It improves patient satisfaction, reduces the length of stay, and is associated with fewer complications. However, few devices and tools are available for the treatment of peripheral arterial disease via a transradial approach (TRA). The S.M.A.R.T. RADIANZ Vascular Stent System is among the RADIANZ suite of products, which is aimed at expanding the portfolio of devices to treat peripheral arterial disease. AREAS COVERED: In this Expert review, the following areas will be covered: (1) Current Landscape of peripheral vascular intervention (PVI) using TRA (2) Detailed description of the S.M.A.R.T. RADIANZ Vascular Stent System. (3) Ongoing clinical trials to evaluate safety of this approach. (4) Future directions and current regulatory status. EXPERT OPINION: TRA for PVI is a promising approach. It holds the possibility of substantially improving the care of patients with peripheral arterial disease (PAD). Numerous challenges must be overcome to realize the full potential of a radial-to-peripheral (RTP) approach. The length of devices and the small sheath size are the main constraints of this approach. The results of the ongoing RADIANCY trial will demonstrate the safety, in selected patients, of the RADIANZ suite of products.


Asunto(s)
Cateterismo Periférico , Procedimientos Endovasculares , Enfermedad Arterial Periférica , Humanos , Resultado del Tratamiento , Arteria Radial/cirugía , Cateterismo Periférico/métodos , Enfermedad Arterial Periférica/cirugía , Stents
3.
Cardiovasc Intervent Radiol ; 45(12): 1855-1859, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36058996

RESUMEN

PURPOSE: Although effectiveness and safety of many different paclitaxel coated balloons in the treatment of peripheral arterial disease (PAD) are extensively studied, there is a lack of direct head-to-head comparison studies. To meet this need and to avoid potential "class-effects", the BIOPACT was set up. The purpose is to demonstrate the safety and efficacy of the Passeo-18 Lux DCB (Biotronik) for treatment of patients with symptomatic PAD due to femoropopliteal lesions. METHODS: 302 patients are randomized in a 1:1 manner to treatment with either the Passeo-18 Lux DCB or the IN.PACT Admiral DCB (Medtronic) for testing of a formal non-inferiority hypothesis. The participants will be followed for 5 years. The primary efficacy endpoint is freedom from clinically-driven target lesion revascularization (CD-TLR) at 12 months, defined as any re-intervention at the target lesion due to symptoms, drop of ankle brachial index (ABI) > 20% or > 0.15 compared to post-procedural ABI. Primary safety endpoint is a composite of freedom from device/procedure-related death through 30 days post-index procedure, freedom from major target limb amputation and clinically-driven target vessel revascularization (CD-TVR) through 12 months post-index procedure. Secondary endpoints can be found at clinicaltrials.gov, ID NCT03884257. DISCUSSION: As full enrolment was reached by the beginning of September, the investigators expect complete analysis of the primary endpoints by the end of 2022; Meanwhile preliminary results will be disclosed during 2022. As in terms of randomized head-to-head efficacy and safety analysis, this study on paclitaxel coated balloons may provide additional information to clinicians and healthcare providers. Trial registration ClinicalTrials.gov ID: NCT03884257 LEVEL OF EVIDENCE: Level 2, Randomized trial.


Asunto(s)
Angioplastia de Balón , Enfermedad Arterial Periférica , Humanos , Arteria Poplítea/diagnóstico por imagen , Angioplastia de Balón/efectos adversos , Materiales Biocompatibles Revestidos , Grado de Desobstrucción Vascular , Factores de Tiempo , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/patología , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Paclitaxel/efectos adversos , Resultado del Tratamiento
5.
JACC Cardiovasc Interv ; 15(6): 618-626, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-35219622

RESUMEN

OBJECTIVES: The aim of the study was to assess 24-month efficacy and safety of a novel drug-eluting stent (DES) for femoropopliteal interventions with an innovative stent design and abluminal reservoir technology releasing the amphilimus formulation (sirolimus plus fatty acid) for efficient drug transfer and optimized release kinetics. BACKGROUND: DES releasing paclitaxel exhibited good patency rates after femoropopliteal interventions. No benefit has been reported when sirolimus or everolimus were used for antiproliferative stent coating. METHODS: Within a multicenter, first-in-man, single-arm study, 100 patients with symptomatic femoropopliteal disease (Rutherford category 2-4, mean lesion length 5.8 ± 3.9 cm, 35.0% total occlusions) were treated with the NiTiDES stent (Alvimedica). Two-year follow-up included assessment of primary patency (defined as absence of clinically driven target lesion revascularization or binary restenosis with a peak systolic velocity ratio >2.4 by duplex ultrasound), safety, functional, and clinical outcomes. RESULTS: At 24 months, Kaplan-Meier estimates of primary patency and freedom from clinically driven target lesion revascularization were 83.4% (95% CI: 73.9%-89.6%) and 93.1% (95% CI: 85.3%-96.9%), respectively. Over the study period, 3 deaths were reported with no major limb amputation. Functional and clinical benefits were sustained, as 82.1% of patients fell into Rutherford category 0 or 1 at 24 months, which was associated with preserved improvements in all walking disability questionnaire scores. CONCLUSIONS: The 2-year results of the ILLUMINA (Innovative siroLimus seLf expanding drUg-eluting stent for the treatMent of perIpheral disease: evaluation of safety aNd efficAcy) study demonstrate a sustained treatment benefit with a novel sirolimus-eluting stent that also compares favorably to other femoropopliteal intervention trials. Head-to-head comparisons of NiTiDES with a paclitaxel-based DES are warranted. (The ILLUMINA Study [ILLUMINA]; NCT03510676).


Asunto(s)
Fármacos Cardiovasculares , Stents Liberadores de Fármacos , Enfermedad Arterial Periférica , Fármacos Cardiovasculares/efectos adversos , Arteria Femoral/diagnóstico por imagen , Humanos , Paclitaxel/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Arteria Poplítea/diagnóstico por imagen , Sirolimus/efectos adversos , Stents , Resultado del Tratamiento , Grado de Desobstrucción Vascular
6.
EuroIntervention ; 18(1): 50-57, 2022 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-34794937

RESUMEN

BACKGROUND: Although the presence of a thrombus contraindicates left atrial appendage closure procedure (LAAC), a previous study reported the feasibility of the thrombus trapping procedure (TTP) technique to overcome this limitation. AIMS: This study aimed to analyse the short-term outcomes in a series of patients who underwent LAAC using the TTP (TTP-LAAC). METHODS: This retrospective series included patients who underwent TTP-LAAC between January 2018 and May 2020 in 13 European centres. Device choice, pre-interventional work-up and post-discharge antithrombotic therapy regimens were left to the discretion of the operators. The primary endpoint was the 30-day occurrence of stroke, systemic embolism or cardiovascular death. RESULTS: During the study period, a total of 1,918 patients underwent LAAC. A thrombus was identified in 71 cases but completely disappeared in 24 patients before procedure. TTP-LAAC was finally performed in 53 cases (3%). Thrombi were identified ahead of the actual day of implantation in 47 patients (87%) and were mostly limited in size (50 cases with extension <50% of the LAA surface). The Amplatzer Amulet and WATCHMAN FLX occluders were implanted in 44 and 9 patients, respectively. A single deployment approach was applied in 70% and a cerebral embolic protection system was used in 9% of the patients. The overall success rate was 100%. Small pericardial effusion without tamponade was observed in 6% of the cases. Patients were discharged with 72% under antiplatelet therapy and 10% under short-term oral anticoagulation. The primary endpoint occurred in one patient. CONCLUSIONS: TTP-LAAC might be used in a minority of LAAC procedures but appears to be feasible and safe in the short-term, in select cases.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Cuidados Posteriores , Apéndice Atrial/cirugía , Humanos , Alta del Paciente , Sistema de Registros , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Trombosis/cirugía , Resultado del Tratamiento
7.
Eur J Vasc Endovasc Surg ; 61(1): 98-105, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33004284

RESUMEN

OBJECTIVE: Endovascular repair is the preferred method of treatment for infrarenal abdominal aortic aneurysms with numerous publications from multiple geographic regions showing excellent patient outcomes. Since the original ACE (Anevrysme de l'aorte abdominale: Chirurgie versus Endoprothese) randomised control trial, studies of French specific population have also contributed significantly to the body of evidence in support of endovascular abdominal aortic repair. METHODS: In the ENDURANT France registry, 180 patients were consecutively enrolled from 20 French centres starting in 2012. Investigational sites included public and private practice and differing centre volumes to be as representative of real world French experience as possible. The aim of this study was to present the five year outcomes from this registry. RESULTS: Instructions for use (IFU) were respected in 97.8% (176/180) of patients. At five years, the Kaplan-Meier overall survival was 69.9% ± 3.5% and the freedom from aneurysm related death was 97.6% ± 1.2%. The freedom from Type IA endoleaks was 94.5% ± 1.7%, freedom from endoleaks of any type was 70.1 ± 3.4%, and freedom from secondary endovascular procedure 90.4% ± 2.6%. In addition, 61.6% (45/73) of patients exhibited sac shrinkage at five years. CONCLUSION: In this five year report of the Endurant France registry, survival, re-intervention, and freedom from endoleak rates were comparable to recent EVAR registries and there was a high sac shrinkage rate. Secondary procedure and aneurysm rupture were lower than those of ACE, the French RCT which included older generation devices. This prospective registry demonstrates favourable five year outcomes of the Endurant stent graft used within IFU.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares , Anciano , Aneurisma de la Aorta Abdominal/mortalidad , Conversión a Cirugía Abierta/estadística & datos numéricos , Endofuga/epidemiología , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/mortalidad , Femenino , Francia/epidemiología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Sistema de Registros , Reoperación/estadística & datos numéricos , Análisis de Supervivencia , Resultado del Tratamiento
8.
JACC Cardiovasc Interv ; 13(4): 447-457, 2020 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-32081238

RESUMEN

OBJECTIVES: The primary objective of the BATTLE (Bare Metal Stent vs. Paclitaxel Eluting Stent in the Setting of Primary Stenting of Intermediate-Length Femoropopliteal Lesions) trial is to demonstrate the clinical superiority of the Zilver PTX stent over the Misago stent in the treatment of femoropopliteal lesions. BACKGROUND: No randomized studies have compared self-expanding paclitaxel-eluting stents with bare-metal stents in the treatment of femoropopliteal lesions. METHODS: BATTLE is a multicenter randomized controlled trial in patients with symptomatic (Rutherford category 2 to 5) de novo lesions of the superficial femoral or proximal popliteal artery. The primary endpoint is freedom from in-stent restenosis (ISR) at 1 year, with restenosis defined as a peak systolic velocity index >2.4 at the target lesion. The Kaplan-Meier method was used to evaluate time-to-event data for freedom from ISR over the 2-year follow-up period. RESULTS: Between March 2014 and August 2016, 186 patients were enrolled; 91 were assigned to the Misago arm and 90 to the Zilver PTX arm. Kaplan-Meier 1-year estimates of freedom from ISR were 88.6% for Misago and 91% for Zilver PTX (hazard ratio [HR]: 1.2; 95% confidence interval [CI]: 0.6 to 2.4; p = 0.64). Comparing Misago with Zilver PTX, 2-year estimates were 6.4% and 1.2% (HR: 7.3; 95% CI: 0.9 to 59.3; p = 0.0632) for mortality, 74.6% and 78.8% (HR: 1.2; 95% CI: 0.6 to 2.1; p = 0.62) for patency, and 14.4% and 12.4% (HR: 1.2; 95% CI: 0.5 to 2.8; p = 0.69) for target lesion revascularization. CONCLUSIONS: In the treatment of symptomatic femoropopliteal lesions, the Zilver PTX stent failed to show superiority over the Misago stent in freedom from ISR at 1 year.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Procedimientos Endovasculares/instrumentación , Arteria Femoral , Metales , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Stents , Anciano , Anciano de 80 o más Años , Fármacos Cardiovasculares/efectos adversos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Francia , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Estudios Prospectivos , Diseño de Prótesis , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
10.
Quant Imaging Med Surg ; 10(1): 283-293, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31956549

RESUMEN

BACKGROUND: To ascertain the safety and mid-term outcomes of Rotarex®S rotational atherectomy plus thrombectomy device (Straub Medical AG, Wangs, Switzerland) with or without adjunctive treatment (e.g., percutaneous transluminal angioplasty, PTA/drug-coated balloon, DCB/stenting) in patients with in-stent restenosis (ISR) or occlusion in the iliac and/or infrainguinal arteries. METHODS: French multicenter retrospective study of all patients treated by in-stent percutaneous mechanical debulking (PMD) of the lower limbs with Rotarex®S device between January 2013 and November 2018. RESULTS: The cohort consisted of 128 patients (88 men and 40 women), aged 39-94 years (mean, 66.7±12 years). All patients presented with cardio-vascular risk factors. Overall, 51.5% of patients had critical limb ischemia. The study demonstrated a technical success of 96.9% in the population with PMD and adjunctive PTA (95/128, 74.2%) or adjunctive DCB (16/128, 12.5%) or both (13/128, 10.2%). At 12-months follow-up, the primary clinical success/patency rate was 92.3% and the secondary clinical success/patency rate was 91.4%. Rate of limb salvage was 93.7%. Overall 32 (25%) reinterventions were reported with mean time from Rotarex®S treatment to reintervention of 7.1±8.2 months. Target lesion revascularization (TLR) was 19.5% (25/128). Seven (5.5%) patients developed distal embolism that responded to endovascular treatment. At mean follow-up, major adverse events (MAE) observed were death (18/128, 14.1%), myocardial infarction (MI) (9/128, 7.0%), stroke (2/128, 1.6%) and renal failure (3/128, 2.3%). CONCLUSIONS: Recanalization with Rotarex®S rotational atherectomy plus thrombectomy device is a practical choice for arterial ISR/occlusions of the iliac and/or infrainguinal arteries, regardless of the age of the thrombus, with satisfying TLR. Only adjunctive PTA is often necessary to further improve the recanalization.

11.
JACC Case Rep ; 2(15): 2394-2396, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34317178

RESUMEN

We report the case of an extended pseudo-subarachnoid hemorrhage (PSAH) related to contrast intracerebral diffusion from blood-brain barrier breakdown on periprocedural percutaneous coronary intervention right corticofrontal ischemic stroke. PSAH is a rare and complex phenomenon, and it is important to differentiate PSAH from subarachnoid hemorrhage to avoid inappropriate treatment with potentially severe consequences. (Level of Difficulty: Beginner.).

14.
J Cardiovasc Surg (Torino) ; 60(2): 198-204, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30650962

RESUMEN

Endovascular treatment for peripheral artery occlusive disease carries unresolved problem of restenosis. Treatment modalities in areas of high mechanical stress like popliteal artery and common femoral artery remains challenging. New-generation devices improved the results of stent therapy in this anatomical territory, but could impact on future surgical options if they are needed. Vessel preparation prior to drug (paclitaxel)-coated balloons (DCB) angioplasty leads to better paclitaxel penetration into the arterial wall and improved drug uptake. The "leave nothing behind" strategies, DCB angioplasty and combined directional atherectomy (DA) and antirestenotic therapy (DAART), can theoretically overcome the problems caused by the mobility of the knee joint. However, calcified and longer lesions remain a challenging subset that is less responsive to DCBs, resulting in higher provisional stent rates. For the treatment of long and calcified femoropopliteal lesions, vessel preparation with DA before DCB angioplasty seems to be safe in mid-term follow-up and might have benefits in more challenging lesion subsets that are at higher risk for acute and chronic technical treatment failure of percutaneous transluminal angioplasty, including DCB angioplasty, such as severely calcified lesions. Treatment with DA+DCB resulted in both increased technical success and fewer flow-limiting dissections compared with treatment with DCB alone. In concept of "leave nothing behind" therapies for isolated popliteal artery lesions, DAART was associated with a higher primary patency rate than DCB angioplasty alone.


Asunto(s)
Angioplastia de Balón , Aterectomía , Enfermedad Arterial Periférica/terapia , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/instrumentación , Aterectomía/efectos adversos , Aterectomía/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Constricción Patológica , Humanos , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Recurrencia , Factores de Riesgo , Resultado del Tratamiento , Dispositivos de Acceso Vascular , Grado de Desobstrucción Vascular
15.
JACC Cardiovasc Interv ; 11(10): 934-941, 2018 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-29730375

RESUMEN

OBJECTIVES: The authors sought to evaluate the performance of the Ranger paclitaxel-coated balloon versus uncoated balloon angioplasty for femoropopliteal lesions at 12 months. BACKGROUND: Drug-coated balloons (DCBs) are a promising endovascular treatment option for peripheral artery disease of the femoropopliteal segment, and each unique device requires dedicated clinical study. METHODS: The prospective, randomized RANGER SFA (Comparison of the Ranger™ Paclitaxel-Coated PTA Balloon Catheter and Uncoated PTA Balloons in Femoropopliteal Arteries) study (NCT02013193) enrolled 105 patients with symptomatic lower limb ischemia (Rutherford category 2 to 4) and stenotic lesions in the nonstented femoropopliteal segment at 10 European centers. Seventy-one patients (mean age 68 ± 8 years, n = 53 men) were enrolled in the Ranger DCB arm, and 34 patients (mean age 67 ± 9 years, n = 23 men) were assigned to the control group. Twelve-month analysis included patency, safety, and clinical outcomes and quality-of-life assessments. RESULTS: The DCB group had a greater primary patency rate at 12 months (Kaplan-Meier estimate 86.4% vs. 56.5%), with a significantly longer time to patency failure (log-rank p < 0.001). The estimated freedom from target lesion revascularization rate was 91.2% in the DCB group and 69.9% in the control group at 12 months, with a significantly longer time to reintervention (p = 0.010). No target limb amputations or device-related deaths occurred in either group. CONCLUSIONS: Twelve-month results show that patency was maintained longer after Ranger DCB treatment than after conventional balloon angioplasty, and this result was associated with a low revascularization rate and good clinical outcomes.


Asunto(s)
Angioplastia de Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Arteria Femoral , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Dispositivos de Acceso Vascular , Anciano , Angioplastia de Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Constricción Patológica , Europa (Continente) , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Estudios Prospectivos , Recurrencia , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
17.
J Endovasc Ther ; 24(4): 459-467, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28558502

RESUMEN

PURPOSE: To evaluate the performance of the Ranger paclitaxel-coated balloon vs uncoated balloon angioplasty for femoropopliteal lesions. METHODS: Between January 2014 and October 2015, the prospective, randomized RANGER SFA study ( ClinicalTrials.gov identifier NCT02013193) enrolled 105 patients with symptomatic lower limb ischemia (Rutherford category 2-4) and stenotic lesions in the nonstented femoropopliteal segment at 10 European centers. Seventy-one patients (mean age 68±8 years; 53 men) were enrolled in the Ranger drug-coated balloon (DCB) arm and 34 patients (mean age 67±9 years; 23 men) were assigned to the control group. Six-month analysis included angiographic late lumen loss and safety and clinical outcomes assessments. RESULTS: Baseline characteristics of the DCB and control groups were similar, as were lesion lengths (68±46 vs 60±48 mm; p=0.731), severity of calcification (p=0.236), and the prevalence of occlusions (34% vs 34%; p>0.999). At 6 months, late lumen loss was significantly less for the DCB group vs controls (-0.16±0.99 vs 0.76±1.4; p=0.002). The DCB group had significantly greater freedom from binary restenosis (92% vs 64%; p=0.005) and primary patency rates (87% vs 60%; p=0.014). Target lesion revascularization rates were 5.6% in the DCB group and 12% in the control group (p=0.475). No target limb amputations or device-related deaths occurred in either group. CONCLUSION: Six-month results suggest that Ranger DCB treatment effectively inhibited restenosis in symptomatic femoropopliteal disease, resulting in improved vessel patency and a low revascularization rate in the short term compared with uncoated balloon angioplasty.


Asunto(s)
Angioplastia de Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Arteria Femoral , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Dispositivos de Acceso Vascular , Anciano , Angioplastia de Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Diseño de Equipo , Europa (Continente) , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Estudios Prospectivos , Recurrencia , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
18.
JACC Cardiovasc Interv ; 9(11): 1178-87, 2016 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-27282601

RESUMEN

OBJECTIVES: This is the first-in-human study of a drug-eluting bioresorbable vascular scaffold (BVS) for treatment of peripheral artery disease (PAD) involving the external iliac artery (EIA) and superficial femoral artery (SFA). BACKGROUND: Drug-eluting BVS has shown promise in coronary arteries. METHODS: The ESPRIT BVS system is a device-drug combination consisting of an everolimus-eluting poly-l-lactide scaffold. Safety and performance were evaluated in 35 subjects with symptomatic claudication. RESULTS: Lesions were located in the SFA (88.6%) and EIA (11.4%). Mean lesion length was 35.7 ± 16.0 mm. The study device was successfully deployed in 100% of cases, without recoil. Procedure-related minor complications were observed in 3 patients (groin hematoma, dissection). Within 2 years there was 1 unrelated death, but no patients in this cohort had an amputation. At 1 and 2 years, the binary restenosis rates were 12.1% and 16.1%, respectively, and target lesion revascularization was performed in 3 of 34 patients (8.8%) and 4 of 32 patients (11.8%), respectively. The ankle brachial index 0.75 ± 0.14 improved from pre-procedure to 0.96 ± 0.16 at 2 years' follow-up. At 2 years, 71.0% of the patients were Rutherford-Becker 0, and 93.5% achieved a maximum walking distance of 1,500 feet. CONCLUSIONS: The safety of the ESPRIT BVS was demonstrated with no procedure or device-related deaths or amputations within 2 years. The low occurrence of revascularizations was consistent with duplex-ultrasonography showing sustained patency at 2-years. (A Clinical Evaluation of the Abbott Vascular ESPRIT BVS [Bioresorbable Vascular Scaffold] System [ESPRIT I]; NCT01468974).


Asunto(s)
Implantes Absorbibles , Angioplastia de Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Everolimus/administración & dosificación , Arteria Femoral , Arteria Ilíaca , Claudicación Intermitente/terapia , Enfermedad Arterial Periférica/terapia , Anciano , Angiografía , Angioplastia de Balón/efectos adversos , Índice Tobillo Braquial , Fármacos Cardiovasculares/efectos adversos , Everolimus/efectos adversos , Tolerancia al Ejercicio , Estudios de Factibilidad , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Claudicación Intermitente/diagnóstico por imagen , Claudicación Intermitente/fisiopatología , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Recurrencia , Retratamiento , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
19.
EuroIntervention ; 9(12): 1385-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24161437

RESUMEN

We describe the first use of transradial access renal denervation in a patient with resistant hypertension using a dedicated radiofrequency catheter (Iberis™; Terumo Medical Corporation, Tokyo, Japan). The system includes a generator and a 4 Fr single-use radiofrequency (RF) device which has to be introduced via a 6 Fr guiding catheter. Radiofrequency energy is delivered at the tip of the catheter. The system was CE approved in March 2013.


Asunto(s)
Presión Sanguínea , Ablación por Catéter , Hipertensión/cirugía , Riñón/irrigación sanguínea , Arteria Radial , Arteria Renal/inervación , Simpatectomía , Dispositivos de Acceso Vascular , Anciano , Antihipertensivos/uso terapéutico , Presión Sanguínea/efectos de los fármacos , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Resistencia a Medicamentos , Diseño de Equipo , Humanos , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Masculino , Arteria Radial/diagnóstico por imagen , Radiografía Intervencional , Arteria Renal/diagnóstico por imagen , Simpatectomía/instrumentación , Simpatectomía/métodos , Resultado del Tratamiento
20.
EuroIntervention ; 7(9): 1069-76, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21959084

RESUMEN

AIMS: To compare the outcomes of drug-eluting (DES) vs. bare-metal (BMS) stents for stenting of native aorto-ostial lesions (AOL) and to identify predictors of major adverse cardio and cerebrovascular events (MACCE). METHODS AND RESULTS: A total of 181 patients (182 AOL) who underwent stenting of AOL were retrospectively identified: right-coronary artery in 130 (71.4%), left main in 52 (28.6%). In-hospital event rate was 1.1% (two non-Q-wave myocardial infarctions). Follow-up was possible in 98.3%, median time=23.9 months (IQR 12.1-37.7). Event rates and survival MACCE-free were not significantly different between DES and BMS. After multivariate analysis, only the logistic EuroSCORE >10% predicted MACCE (HR=4.66, 95% CI: 2.38-9.12, p<0.001), whereas the predictors for TLR were age (HR=0.96, 95% CI: 0.92-1.00, p=0.039) and the stented artery (RCA vs. LM, HR=10.2, 95% CI: 1.37-75.45, p=0.024). CONCLUSIONS: AOL stenting can be performed with high success and low complication rates. At follow-up, no significant differences in event rates were found between DES and BMS; EuroSCORE>10% was the only predictor of MACCE.


Asunto(s)
Angioplastia/métodos , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/terapia , Stents Liberadores de Fármacos , Metales , Stents , Anciano , Anciano de 80 o más Años , Enfermedades de la Aorta/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/epidemiología , Pronóstico , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...