Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J AOAC Int ; 105(1): 1-10, 2022 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-34338773

RESUMEN

BACKGROUND: Nitrosamine impurities are potent carcinogens in animals and probable carcinogens in humans. There is a need for effective analytical methods to detect and identify various nitrosamine impurities, and to develop rapid solutions to ensure the safety and quality of the drugs. OBJECTIVE: A liquid chromatographic method was developed for estimation of six nitrosamine impurities in valsartan. METHODS: The developed method employed: a C18 (250 × 4.6 mm, 5 µm) column as a stationary phase; a combination of acetonitrile, water (pH 3.2 adjusted with formic acid), and methanol with gradient elution as mobile phase; and 228 nm as the detection wavelength. The developed method was validated as per International Conference on Harmonization Q2(R1) guidelines. The method was successfully applied to estimate six nitrosamine impurities in valsartan API (active pharmaceutical ingradient) and formulation (tablets). RESULTS: The method was able to separate each impurity and valsartan with resolved and sharp peaks. Results indicated that the developed method is linear in selected ranges (coefficient of regressions >0.9996), precise (RSD <2%), accurate (recovery in a range of 99.02-100.16%), sensitive (low detection and quantitation limits), and specific for estimation of each impurity in valsartan. Assay results were in agreement with the spiked amount of each impurity. CONCLUSION: The developed method can be applied for simultaneous estimation of six nitrosamine impurities in valsartan raw material, tablets, and fixed dose combination at very low levels. HIGHLIGHTS: Development, validation, and application of a HPLC method for the estimation of six nitrosamine impurities in valsartan API and formulation samples.


Asunto(s)
Nitrosaminas , Cromatografía Líquida de Alta Presión , Humanos , Límite de Detección , Reproducibilidad de los Resultados , Comprimidos , Valsartán
2.
J Pharm Biomed Anal ; 30(4): 1319-29, 2002 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-12408922

RESUMEN

The present study describes development of a sensitive and simple HPTLC method for estimation of lomefloxacin (LMF) in human urine. The drug was extracted using chloroform after adjusting the pH of urine to 7.0. Chloroform extract was spotted on silica gel 60 F(254) TLC plate and was developed in a mixture of n-butanol-methanol-ethyl acetate-6 M ammonia (4:2:3:2, v/v/v/v) as the mobile phase and scanned at 290 nm. The peak for LMF resolved at R(F) of 0.40+/-0.02. The method was validated in terms of linearity (50-600 microgram/ml), precision, specificity and accuracy. The limit of detection and limit of quantification for LMF in urine were found to be 20 and 50 microgram/ml, respectively. The average recovery of LMF from urine was 91.93%. The proposed method was applied to generate urinary excretion data for LMF after administration of two market LMF tablet formulations (400 mg, Formulation R and Formulation T) to six healthy human volunteers in a two-treatment, open, crossover design. Various pharmacokinetic parameters like peak excretion rate ((dAU/dt)(max)), time for peak excretion rate (t(max)), AUC(0-48), AUC(0- infinity ), cumulative amount and % cumulative amount of LMF excreted, elimination half-life (t(1/2)), terminal elimination rate constant (k(el)) and overall elimination rate constant (K), were calculated for both the formulations. The average cumulative amounts of LMF excreted in urine after administration of Formulation R and Formulation T were found to be 321.60 mg (80.40% of dose) and 296.51 mg (74.13% of dose), respectively. The urinary excretion profiles of LMF upto 48 h for both the formulations were found to be similar. Statistical comparison (90% confidence intervals of ratio) of various pharmacokinetic parameters of Formulation T with that of Formulation R revealed that Formulation T is bioequivalent with Formulation R.


Asunto(s)
Antiinfecciosos/farmacocinética , Antiinfecciosos/orina , Fluoroquinolonas , Quinolonas/farmacocinética , Quinolonas/orina , Adulto , Cromatografía Líquida de Alta Presión/métodos , Intervalos de Confianza , Estudios Cruzados , Humanos , Masculino , Proyectos Piloto , Comprimidos , Equivalencia Terapéutica
3.
Artículo en Inglés | MEDLINE | ID: mdl-11863299

RESUMEN

A sensitive and simple HPTLC method was developed for estimation of ranitidine in human urine. The drug was extracted from urine after basification using dichloromethane. Dichloromethane extract was spotted on silica gel 60 F254 TLC plate and was developed in a mixture of ethyl acetate-methanol-ammonia (35:10:5 v/v) as the mobile phase and scanned at 320 nm. The RF value obtained for the drug was 0.67 +/- 0.03. The method was validated in terms of linearity (50-400 ng/spot), precision and accuracy. The average recovery of ranitidine from urine was 89.35%. The proposed method was applied to evaluate bioequivalence of two marketed ranitidine tablet formulations (150 mg, Formulation I and Formulation 2) using a crossover design by comparing urinary excretion data for unchanged ranitidine in six healthy volunteers. Various pharmacokinetic parameters like peak excretion rate [(dAU/dt)max], time for peak excretion rate (tmax), AUC0-24, AUC0-infinity, cumulative amount excreted were calculated for both formulations and subjected to statistical analysis. The relative bioavailability of Formulation 2 with respect to Formulation 1 was 93.76 and 95.31% on the basis of AUC0-24 and cumulative amount excreted, respectively. Statistical comparison of various pharmacokinetic parameters indicated that the two ranitidine tablet formulations are bioequivalent.


Asunto(s)
Cromatografía en Capa Delgada/métodos , Antagonistas de los Receptores H2 de la Histamina/orina , Ranitidina/orina , Área Bajo la Curva , Disponibilidad Biológica , Calibración , Antagonistas de los Receptores H2 de la Histamina/farmacocinética , Humanos , Ranitidina/farmacocinética , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Equivalencia Terapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA