Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
3.
J Cardiovasc Electrophysiol ; 33(8): 1747-1755, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35671359

RESUMEN

AIMS: Cardiac tamponade is a high morbidity complication of transseptal puncture (TSP). We examined the associations of TSP-related cardiac tamponade (TRCT) for all patients undergoing left atrial ablation at our center from 2016 to 2020. METHODS AND RESULTS: Patient and procedural variables were extracted retrospectively. Cases of cardiac tamponade were scrutinized to adjudicate TSP culpability. Adjusted multivariate analysis examined predictors of TRCT. A total of 3239 consecutive TSPs were performed; cardiac tamponade occurred in 51 patients (incidence: 1.6%) and was adjudicated as TSP-related in 35 (incidence: 1.1%; 68.6% of all tamponades). Patients of above-median age [odds ratio (OR): 2.4 (1.19-4.2), p = .006] and those undergoing re-do procedures [OR: 1.95 (1.29-3.43, p = .042] were at higher risk of TRCT. Of the operator-dependent variables, choice of transseptal needle (Endrys vs. Brockenbrough, p > .1) or puncture sheath (Swartz vs. Mullins vs. Agilis vs. Vizigo vs. Cryosheath, all p > .1) did not predict TRCT. Adjusting for operator, equipment and demographics, failure to cross the septum first pass increased TRCT risk [OR: 4.42 (2.45-8.2), p = .001], whilst top quartile operator experience [OR: 0.4 (0.17-0.85), p = .002], transoesophageal echocardiogram [TOE prevalence: 26%, OR: 0.51 (0.11-0.94), p = .023], and use of the SafeSept transseptal guidewire [OR: 0.22 (0.08-0.62), p = .001] reduced TRCT risk. An increase in transseptal guidewire use over time (2016: 15.6%, 2020: 60.2%) correlated with an annual reduction in TRCT (R2 = 0.72, p < .001) and was associated with a relative risk reduction of 70%. CONCLUSIONS: During left atrial ablation, the risk of TRCT was reduced by operator experience, TOE-guidance, and use of a transseptal guidewire, and was increased by patient age, re-do procedures, and failure to cross the septum first pass.


Asunto(s)
Fibrilación Atrial , Taponamiento Cardíaco , Ablación por Catéter , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cateterismo Cardíaco , Taponamiento Cardíaco/diagnóstico por imagen , Taponamiento Cardíaco/epidemiología , Taponamiento Cardíaco/etiología , Ablación por Catéter/métodos , Humanos , Punciones/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
4.
J Interv Card Electrophysiol ; 63(2): 259-266, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33638777

RESUMEN

PURPOSE: A significant proportion of patients undergoing catheter ablation for atrial fibrillation (AF) experience arrhythmia recurrence. This is mostly due to pulmonary vein reconnection (PVR). Whether mapping using High-Density Wave (HDW) technology is superior to standard bipolar (SB) configuration at detecting PVR is unknown. We aimed to evaluate the efficacy of HDW technology compared to SB mapping in identifying PVR. METHODS: High-Density (HD) multipolar Grid catheters were used to create left atrial geometries and voltage maps in 36 patients undergoing catheter ablation for AF (either due to recurrence of an atrial arrhythmia from previous AF ablation or de novo AF ablation). Nineteen SB maps were also created and compared. Ablation was performed until pulmonary vein isolation was achieved. RESULTS: Median time of mapping with HDW was 22.3 [IQR: 8.2] min. The number of points collected with HDW (13299.6±1362.8 vs 6952.8±841.9, p<0.001) and used (2337.3±158.0 vs 1727.5±163.8, p<0.001) was significantly higher compared to SB. Moreover, HDW was able to identify more sleeves (16 for right and 8 for left veins), where these were confirmed electrically silent by SB, with significantly increased PVR sleeve size as identified by HDW (p<0.001 for both right and left veins). Importantly, with the use of HDW, the ablation strategy changed in 23 patients (64% of targeted veins) with a significantly increased number of lesions required as compared to SB for right (p=0.005) and left veins (p=0.003). CONCLUSION: HDW technology is superior to SB in detecting pulmonary vein reconnections. This could potentially result into a significant change in ablation strategy and possibly to increased success rate following pulmonary vein isolation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Catéteres , Técnicas Electrofisiológicas Cardíacas , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
6.
Int J Cardiol Heart Vasc ; 27: 100490, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32181321

RESUMEN

BACKGROUND: Atrial tachyarrhythmias (ATs) are a major source of morbidity in the atrial septal defect (ASD) patient cohort. The optimal timing and approach of anti-arrhythmic intervention is currently unclear. Here, we sought to determine the overall rate of ATs following percutaneous ASD closure and risk factors that may predict this. METHODS: A systematic search of the literature was performed using the search terms '(Secundum Atrial Septal Defects AND Atrial arrhythmias) AND (transcatheter closure or percutaneous closure or device closure)'. All studies in English reporting the rate of ATs following percutaneous closure of secundum ASDs in adult patients were included. The primary outcome was documented AT detection during follow-up ECG monitoring. A meta-regression was then performed to test for an interaction between demographic/procedural characteristics and the primary outcome. RESULTS: 13 observational studies including 2366 patients were analysed. The overall post-procedure AT event detection rate was 8.6%. Multivariate meta-regression analysis revealed that only male gender was associated with a higher rate of post-procedure AT detection while utilisation of the Amplatzer Septal Occluder device was associated with a lower AT detection rate and comprised 96.2% of all devices used. A high level of heterogeneity was observed (I2-statistic 92.3%, Q value 156.8). CONCLUSIONS: Our study illustrates that despite percutaneous ASD closure, a high proportion of adult patients have ATs with male gender correlating with higher AT rates. While the Amplatzer Septal Occluder device correlated with lower AT rates, this was the overwhelmingly the predominant device used hence comparison to other devices remains challenging.

7.
J Cardiovasc Electrophysiol ; 31(4): 903-912, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32048786

RESUMEN

BACKGROUND: Noninvasive mapping identifies potential drivers (PDs) in atrial fibrillation (AF). We analyzed the impact of pulmonary vein isolation (PVI) on PDs and whether baseline PD pattern predicted termination of AF. METHODS: Patients with persistent AF less than 2 years underwent electrocardiographic imaging mapping before and after cryoballoon PVI. We recorded the number of PD occurrences, characteristics (rotational wavefronts ≥ 1.5 revolutions or focal activations), and distribution using an 18-segment atrial model. RESULTS: Of 100 patients recruited, PVI terminated AF in 15 patients; 21.3% ± 9.1% (8.7 ± 4.8) of PDs occurred at the pulmonary veins (PVs) and posterior wall. PVI had no impact on PD occurrences outside the PVs and posterior wall (33.2 ± 12.9 vs 31.6 ± 12.5; P = .164), distribution over the remaining 13 segments (9 [8-11] vs 9 [8-10]; P = .634), the proportion of PDs that was rotational (82.9% ± 9.7% vs 83.6% ± 10.1%; P = .496), or temporal stability (2.4 ± 0.4 vs 2.4 ± 0.5 rotations; P = .541). Fewer focal PDs (area under the curve, 0.683; 95% CI, 0.528-0.839; P = .024) but not rotational PDs (P = .626) predicted AF termination with PVI. CONCLUSIONS: PVI did not have a global impact on PDs outside the PVs and posterior wall. Although fewer focal PDs predicted termination of AF with PVI, the burden of rotational PDs did not. It is accepted though not all PDs are necessarily real or important. Outcome data are needed to confirm whether noninvasive mapping can predict patients likely to respond to PVI.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Criocirugía , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Electrocardiografía , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
8.
BMJ Case Rep ; 13(1)2020 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-31948978

RESUMEN

Here we present a rare clinical presentation of papillary muscle rupture in a 55-year-old man who presented to accident and emergency department with chest pain and was diagnosed as having had a non-ST elevation myocardial infarction. During the admission, he developed papillary muscle rupture due to the myocardial infarction resulting in acute mitral regurgitation. This caused significant haemodynamic compromise needing emergency admission to the intensive care unit and eventually surgery to replace the valve.


Asunto(s)
Rotura Cardíaca Posinfarto/etiología , Rotura Cardíaca Posinfarto/cirugía , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio sin Elevación del ST/complicaciones , Músculos Papilares/lesiones , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Músculos Papilares/cirugía
9.
Europace ; 22(3): 375-381, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31808520

RESUMEN

AIMS: Although cryoballoon pulmonary vein isolation is a well-established treatment for paroxysmal atrial fibrillation (AF), it's role in persistent AF is unclear. We examined procedural success and long-term outcomes of cryoablation in persistent and longstanding persistent AF. METHODS AND RESULTS: International multicentre registry from three UK and eight European centres. Consecutive patients undergoing cryoablation for persistent AF included. Procedural data, complications, and follow-up were prospectively recorded. Patients were followed-up at 3, 6, and 12 months with an electrocardiogram with open access to arrhythmia nurses thereafter. Ambulatory monitoring was dictated by symptoms. Success was defined as freedom from AF or atrial tachycardia lasting >30 s off antiarrhythmic drugs (AADs). Six hundred and nine consecutive cryoablation procedures. Mean procedure and fluoroscopy times were 95 ± 65 and 13 ± 10 min. Single procedure success rates were 368/602 (61%) off AADs over a median of 2.4 (1.0-4.0) years. Arrhythmia-free survival off AADs was 64% and 57% for persistent and longstanding persistent AF at 24 months of follow-up (P = 0.02). Rate of repeat ablations was 20% in persistent and 32% in longstanding persistent AF (P = 0.006). Cox regression analyses showed a significant association between duration of AF and left atrial diameter and arrhythmia recurrence [hazard ratio (HR) 1.05, P-value 0.01 and HR 1.02, P-value 0.004]. CONCLUSION: Cryoablation for persistent AF is safe, fast and has good outcomes at long-term follow-up. Cryoablation is reasonable as a first line option for these patients. Short procedure times may help increase capacity of cardiac units to meet the rising demand for AF ablation. Randomised control trials are needed to compare outcomes with different techniques.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Sistema de Registros , Resultado del Tratamiento
10.
JACC Clin Electrophysiol ; 5(12): 1459-1472, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31857047

RESUMEN

OBJECTIVES: A new electroanatomic mapping system (Rhythmia, Boston Scientific, Marlborough, Massachusetts) using a 64-electrode mapping basket is now available; we systematically assessed its use in complex congenital heart disease (CHD). BACKGROUND: The incidence of atrial arrhythmias post-surgery for CHD is high. Catheter ablation has emerged as an effective treatment, but is hampered by limitations in the mapping system's ability to accurately define the tachycardia circuit. METHODS: Mapping and ablation data of 61 patients with CHD (35 males, age 45 ± 14 years) from 8 tertiary centers were reviewed. RESULTS: Causes were as follows: Transposition of Great Arteries (atrial switch) (n = 7); univentricular physiology (Fontans) (n = 8); Tetralogy of Fallot (n = 10); atrial septal defect (ASD) repair (n = 15); tricuspid valve (TV) anomalies (n = 10); and other (n = 11). The total number of atrial arrhythmias was 86. Circuits were predominantly around the tricuspid valve (n = 37), atriotomy scar (n = 10), or ASD patch (n = 4). Although the majority of peri-tricuspid circuits were cavo-tricuspid-isthmus dependent (n = 30), they could follow a complex route between the annulus and septal resection, ASD patch, coronary sinus, or atriotomy. Immediate ablation success was achieved in all but 2 cases; with follow-up of 12 ± 8 months, 7 patients had recurrence. CONCLUSIONS: We demonstrate the feasibility of the basket catheter for mapping complex CHD arrhythmias, including with transbaffle and transhepatic access. Although the circuits often involve predictable anatomic landmarks, the precise critical isthmus is often difficult to predict empirically. Ultra-high-density mapping enables elucidation of circuits in this complex anatomy and allows successful treatment at the isthmus with a minimal lesion set.


Asunto(s)
Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Cardiopatías Congénitas , Taquicardia , Adulto , Anciano , Ablación por Catéter/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Diseño de Equipo , Femenino , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia/diagnóstico por imagen , Taquicardia/etiología , Taquicardia/fisiopatología
11.
J Cardiovasc Electrophysiol ; 30(3): 357-365, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30556609

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. METHODS: Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. RESULTS: One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 Ω, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group ( P = 0.186). CONCLUSION: High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estudios de Casos y Controles , Ablación por Catéter/efectos adversos , Inglaterra , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Tempo Operativo , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Pacing Clin Electrophysiol ; 42(1): 4-12, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30397922

RESUMEN

BACKGROUND: Transseptal puncture (TSP) is commonly performed under fluoroscopic guidance in left atrial ablation procedures. This exposes patients and healthcare professionals to deleterious ionizing radiation. We describe a novel technique for performing TSP non-fluoroscopically using a three-dimensional (3D) mapping system only. The safety and efficacy of this technique is compared to traditional fluoroscopy guided TSP. METHODS: Retrospective, single-center study of patients undergoing TSP for left atrial ablation. Those undergoing TSP using 3D mapping system alone (nonfluoroscopy group) were compared to those undergoing fluoroscopic guided TSP (Fluoroscopy group). Clinical, procedural data and complications were analyzed from a prospective registry. RESULTS: Twenty patients (32 TSPs) in the nonfluoroscopy (NF) group were compared to 14 patients (25 TSPs) in fluoroscopy (F) group. TSP success rates were similar across the groups (88% vs 96% in the NF and F groups, P = 0.97). In the NF group, there was one cardiac tamponade, two unsuccessful TSPs (previous cardiac surgery-required TOE guided TSP), and one patient required fluoroscopy on a background of CRTD device to avoid lead displacement. The mean fluoroscopy time and dose were significantly lower in the nonfluoroscopy group (0.75  ±  0.50 vs 5.32 ± 3.23 min, P  <  0.001; 92.5 ± 60.7 vs 394.3 ± 182.7 cGy/cm2 , P < 0.001). CONCLUSION: Our study shows that TSPs can be performed safely and effectively using this non-fluoroscopic novel technique in a select group of patients. Radiation exposure is reduced significantly without compromising patient safety. Larger studies are required to substantiate these results. Patients with cardiac implantable devices and previous cardiac surgery may pose a challenge to using this technique.


Asunto(s)
Fibrilación Atrial/cirugía , Tabique Interatrial/cirugía , Ablación por Catéter/métodos , Mapeo Epicárdico/métodos , Punciones , Estudios de Casos y Controles , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Exposición a la Radiación , Estudios Retrospectivos
13.
Int J Cardiol ; 277: 110-117, 2019 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-30196998

RESUMEN

BACKGROUND: To investigate the long term outcomes after catheter ablation (CA) of ventricular tachycardia (VT) in the context of structural heart disease in a multicenter cohort. The impact of different ablation strategies (substrate ablation versus activation guided versus combined) and non-inducibility as an end-point was evaluated. METHODS: Data was pooled from prospective registries at 5 centres over a 5 year period. Success was defined as survival free from recurrent ventricular arrhythmias (VA). Multivariate analysis of factors predicting survival free from VA was analysed by Cox regression. RESULTS: Five hundred sixty-six patients underwent CA for VT. Patients were 64 ±â€¯15 years. Left ventricular ejection fraction was 35 ±â€¯15% and 66% had ischaemic heart disease. At 2.3 (IQR 1.0-4.2) years, success was achieved in 44% after a single procedure, rising to 60% after repeat procedures. Mortality at final follow up was 22%. Multivariate analysis showed that higher left ventricular ejection fraction, younger age, ischaemic heart disease, and non-inducibility of VA predicted long term survival free from VA (all p < 0.05). There was no impact of the approach to ablation. CONCLUSION: CA eliminates VT in a large proportion of patients long term. Ablation strategy did not impact outcome and hence substrate ablation is a reasonable initial strategy. Non-inducibility of VA predicted survival free from VA and may be worth pursuing as a procedural end-point.


Asunto(s)
Ablación por Catéter/tendencias , Determinación de Punto Final/tendencias , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Anciano , Ablación por Catéter/mortalidad , Estudios de Cohortes , Determinación de Punto Final/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Mortalidad/tendencias , Estudios Prospectivos , Sistema de Registros , Taquicardia Ventricular/mortalidad , Resultado del Tratamiento
15.
Europace ; 20(12): 1997-2002, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29868905

RESUMEN

Aims: Endocardial left ventricular (LV) pacing is a viable alternative in patients with failed coronary sinus (CS) lead implantation. However, long-term thrombo-embolic risk remains unknown. Much of the data have come from a small number of centres. We examined the safety and efficacy of endocardial LV pacing to determine the long-term thrombo-embolic risk. Methods and results: Registries from four UK centres were combined to include 68 patients with endocardial leads with a mean follow-up of 20 months. These were compared to a matched 1:2 control group with conventional CS leads. Medical records were reviewed, and patients contacted for follow-up. Ischaemic stroke occurred in four patients (6%) in the endocardial arm providing an annual event rate (AER) of 3.6% over a 20 month follow-up; compared to 9 patients (6.6%) amongst controls with an AER of 3.4% over a 23-month follow-up. Regression analyses showed a significant association between sub-therapeutic international normalized ratio and stroke (P = 0.0001) in the endocardial arm. There was no association between lead material and mode of delivery (transatrial/transventricular) and stroke. Mortality rate was 12 and 15 per 100 patient years in the endocardial and control arm respectively with end-stage heart failure being the commonest cause. Conclusion: Endocardial LV lead in heart failure patients has a good success rate at 1.6 year follow-up. However, it is associated with a thrombo-embolic risk (which is not different from conventional CS leads) attributable to sub-therapeutic anticoagulation. Randomized control trials and studies on non-vitamin K antagonist oral anticoagulants are required to ascertain the potential of widespread clinical application of this therapeutic modality.


Asunto(s)
Isquemia Encefálica/etiología , Estimulación Cardíaca Artificial/efectos adversos , Endocardio/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Accidente Cerebrovascular/etiología , Tromboembolia/etiología , Función Ventricular Izquierda , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Coagulación Sanguínea/efectos de los fármacos , Isquemia Encefálica/sangre , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/prevención & control , Estimulación Cardíaca Artificial/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/sangre , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/prevención & control , Tromboembolia/sangre , Tromboembolia/diagnóstico , Tromboembolia/prevención & control , Factores de Tiempo , Resultado del Tratamiento , Reino Unido
16.
Artículo en Inglés | MEDLINE | ID: mdl-29768672

RESUMEN

BACKGROUND: Current consensus guidelines suggest direct oral anticoagulants (DOACs) are interrupted periprocedurally for catheter ablation (CA) of atrial fibrillation (AF). However, this may predispose patients to thromboembolic complications. This study investigates the safety of CA for AF on uninterrupted DOACs compared to uninterrupted warfarin. METHODS: This was a single-center, retrospective study of consecutive patients undergoing CA for AF. All patients were heparinized prior to transseptal puncture with a target-activated clotting time (ACT) of 300-350 seconds. Patients who had procedures performed on continuous DOAC were compared to those on continuous warfarin. Clinical, procedural data, and complications occurring up to 3 months were analyzed from a prospective registry with additional review of electronic health records. RESULTS: A total of 1,884 procedures were performed over 28 months: 761 (609 patients) on uninterrupted warfarin and 1,123 (900 patients) on uninterrupted DOAC (rivaroxaban 64%, apixaban 32%, and dabigatran 4%). There was no difference in the composite endpoint of death, thromboembolism, or major bleeding complication (2.2% vs 1.4%, P = 0.20). There was no difference in the complications comprising this, including tamponade, hematoma, pseudoaneurysm, and transfusion (P-values 0.28, 0.13, 0.45, and 0.36). There were no strokes, transient ischemic attacks, or other thromboembolic complications. There was no difference between groups in the proportion of tamponades requiring reversal of oral anticoagulation, the volume of blood lost, the proportion transfused, or the proportion drained percutaneously (P-values 0.50, 0.51, 0.36, and 0.38). CONCLUSION: Catheter ablation for AF can be performed safely and effectively in patients anticoagulated with DOACs and heparinized with a therapeutic ACT. There is no increased risk of periprocedural bleeding when compared to uninterrupted warfarin.

17.
Pacing Clin Electrophysiol ; 41(4): 353-361, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29344950

RESUMEN

INTRODUCTION: Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. OBJECTIVE: To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. METHODS: EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. RESULTS: Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. CONCLUSION: LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Endocardio/fisiopatología , Insuficiencia Cardíaca/prevención & control , Insuficiencia Cardíaca/fisiopatología , Terapia de Resincronización Cardíaca/métodos , Humanos
18.
Pacing Clin Electrophysiol ; 41(3): 261-266, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29344960

RESUMEN

BACKGROUND: Telomeres are known to provide genomic stability and telomere length has been associated with cardiovascular diseases. Moreover, a higher telomerase activity has been shown to be associated with ventricular arrhythmias (VA) in ischemic cardiomyopathy. Increasing evidence suggests that genetic variation in key telomere genes has an impact on telomerase activity. Each copy of the minor allele of SNP rs12696304, at a locus including TERC (telomerase), has been associated with ∼75 base pairs reduction in mean telomere length likely mediated by an effect on TERC expression. We investigated the impact of genetic variation of this SNP on telomerase and its association with VA in ischemic cardiomyopathy patients. METHODS AND RESULTS: Ninety ischemic cardiomyopathy patients with primary prevention implantable cardioverter defibrillators (ICDs) were recruited. Thirty-five received appropriate ICD therapy for potentially fatal VA (cases), while the remaining 55 patients did not (controls). No significant differences in baseline demographics were seen between the groups. TS was measured by qPCR, telomerase activity by TRAP assay, and SNP genotyping with Taqman probes. Telomerase was highest in C homozygous allele and had a significant association with VA in this group only (C/C,C/G,G/G; P-value 0.04, 0.33, 0.43). CONCLUSION: The present study is the first to examine the association between telomerase, a SNP at a locus including TERC, and VA in ischemic cardiomyopathy patients. Homozygosity for C-allele significantly effects telomerase expression and its association with VA in this cohort. Large-scale prospective studies are required to determine if this genetic variation predisposes patients to greater arrhythmic tendency post-MI.


Asunto(s)
Arritmias Cardíacas/genética , Cardiomiopatías/genética , Isquemia Miocárdica/genética , Polimorfismo de Nucleótido Simple , Telomerasa/genética , Telómero/genética , Anciano , Alelos , Arritmias Cardíacas/enzimología , Cardiomiopatías/enzimología , Estudios de Casos y Controles , Estudios Transversales , Desfibriladores Implantables , Femenino , Variación Genética , Genotipo , Humanos , Masculino , Isquemia Miocárdica/enzimología , Reacción en Cadena de la Polimerasa , Estudios Retrospectivos
19.
J Cardiovasc Electrophysiol ; 28(12): 1423-1432, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28862787

RESUMEN

INTRODUCTION: Panoramic mapping with basket catheters has been used to map atrial fibrillation (AF). However, the limited tissue contact and coverage achieved has raised concerns. METHODS AND RESULTS: Patients undergoing catheter ablation for atrial tachycardia (AT) and persistent AF were recruited. Unipolar signals were recorded with the Constellation or FIRMap catheters. The proportion and distribution of anatomical coverage by the catheters was determined and tissue contact achieved measured. The impact of catheter position, left atrium (LA) size, and bipolar voltage were evaluated. Forty patients were recruited (20 Constellation and 20 FIRMap). The LA coverage achieved with the FIRMap catheter compared to the Constellation catheter was greater (76.9 ± 12.9% vs. 50.8 ± 10.3%; P < 0.001), with better septal coverage (66.8 ± 20.9% vs. 15.5 ± 12.0%; P < 0.001). A greater number of electrodes recorded peak-to-peak electrogram amplitude of ≥0.5 mV (84.2% vs. 62.8%; P < 0.001). Positioning the catheter tip at or posterior to LA appendage ridge gave better coverage than a more anterior position (P = 0.001). Increasing LA area correlated inversely with coverage (P < 0.001) and contact (P = 0.002) despite patient-specific basket catheter sizing. An LA area of >30 cm2 and mean bipolar voltage of <0.3 mV was associated with reduction in coverage and contact (both P < 0.001). There was a significant difference in AT/AF freedom during follow-up in the FIRMap versus Constellation group (13/13 vs. 8/12; P = 0.04). CONCLUSIONS: The FIRMap is superior to the Constellation catheter in terms of LA coverage and contact. Optimizing catheter position and appropriate patient selection based on no more than moderately dilated or scarred atria will also facilitate mapping with basket catheters.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Mapeo del Potencial de Superficie Corporal/normas , Ablación por Catéter/normas , Catéteres/normas , Selección de Paciente , Anciano , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional/métodos , Imagenología Tridimensional/normas , Masculino , Persona de Mediana Edad , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA