Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 42
1.
Article En | MEDLINE | ID: mdl-38744352

BACKGROUND: Sarcopenia, characterized by loss of muscle mass and function, is prevalent in heart failure (HF) and predicts poor outcomes. We investigated alterations in sarcopenia index (SI), a surrogate for skeletal muscle mass, in HF, left ventricular assist device (LVAD) and heart transplant (HT), and assessed its relationship with inflammation and digestive tract (gut and oral) microbiota. METHODS: We enrolled 460 HF, LVAD and HT patients. Repeated measures pre/post procedures were obtained prospectively in a subset of LVAD and HT patients. SI (serum Creatinine/Cystatin C) and inflammatory biomarkers (C-reactive protein, interleukin-6, tumor necrosis factor-alpha) were measured in 271 and 622 blood samples, respectively. Gut and saliva microbiota were assessed via 16S rRNA sequencing among 335 stool and 341 saliva samples. Multivariable regression assessed the relationship between SI and i) New York Heart Association class; ii) pre- vs. post-LVAD or HT; iii) biomarkers of inflammation and microbial diversity. RESULTS: Median (interquartile range) natural logarithm (ln)-SI was -0.13 (-0.32,0.05). Ln-SI decreased across worsening HF class, further declined at 1-month after LVAD and HT and rebounded over time. Ln-SI was correlated with inflammation (r=-0.28, p<0.01), and gut (r=0.28, p<0.01) and oral microbial diversity (r=0.24, p<0.01), these associations remained significant after multivariable adjustment in the combined cohort but not for all individual cohorts. Presence of the gut taxa Roseburia inulinivorans was associated with increased SI. CONCLUSIONS: SI levels decreased in symptomatic HF and remained decreased long-term after LVAD and HT. In the combined cohort, SI levels covaried with inflammation in a similar fashion and significantly related to overall microbial (gut and oral) diversity, including specific taxa compositional changes.

2.
J Heart Lung Transplant ; 43(6): 1010-1020, 2024 Jun.
Article En | MEDLINE | ID: mdl-38360159

Heart transplantation remains the gold standard treatment for end-stage heart failure patients without contraindications. However, limited donor availability and long wait times have created a need for left ventricular assist devices (LVAD) to be used as a bridge to transplantation in appropriately selected patients. Improvements in LVAD technology have resulted in improved short- and long-term outcomes, further supporting the use of these devices for a bridge-to-transplant (BTT) indication. LVAD utilization as BTT exhibits notable disparities worldwide, mainly due to variations in organ availability, allocation policies, and financial constraints. Although Europe has experienced a consistent increase in the use of LVAD for this purpose, the United Network for Organ Sharing 2018 policy amendment resulted in a significant reduction in the number of LVADs used for BTT in the US. To overcome this issue, modifications in the US allocation policy to consider factors such as days on device support, age, and type of complications may be necessary to potentially increase implantation rates.The authors provide an overview comparing the current state of heart transplantation in the US and Europe, with a particular focus on how distinct allocation policies and organ availability impact medical practices. Additionally, the review will examine critical aspects ranging from patient selection and pre-implantation optimization to post-transplant outcomes.


Heart Failure , Heart Transplantation , Heart-Assist Devices , Waiting Lists , Humans , Heart Failure/surgery , Heart Failure/therapy , Europe , Tissue and Organ Procurement , United States , Patient Selection
3.
ASAIO J ; 2024 Feb 20.
Article En | MEDLINE | ID: mdl-38373176

In patients supported by the HeartMate 3 left ventricular assist device (HM3 LVAD), pump speed adjustments may improve hemodynamics. We investigated the hemodynamic implications of speed adjustments in HM3 recipients undergoing hemodynamic ramp tests. Clinically stable HM3 recipients who underwent routine invasive hemodynamic ramp tests between 2015 and 2022 at our center were included. Filling pressure optimization, defined as central venous pressure (CVP) <12 mm Hg and pulmonary capillary wedge pressure (PCWP) <18 mm Hg, was assessed at baseline and final pump speeds. Patients with optimized pressures were compared to nonoptimized patients. Overall 60 HM3 recipients with a median age of 62 years (56, 71) and time from LVAD implantation of 187 days (124, 476) were included. Optimized filling pressures were found in 35 patients (58%) at baseline speed. Speed was adjusted in 84% of the nonoptimized patients. Consequently, 39 patients (65%) had optimized pressures at final speed. There were no significant differences in hemodynamic findings between baseline and final speeds (p > 0.05 for all). Six and 12 month readmission-free rates were higher in optimized compared with nonoptimized patients (p = 0.03 for both), predominantly due to lower cardiac readmission-free rates (p = 0.052). In stable outpatients supported with HM3 who underwent routine ramp tests, optimized hemodynamics were achieved in only 2 of 3 of the patients. Patients with optimized pressures had lower all-cause readmission rates, primarily driven by fewer cardiac-related hospitalizations.

4.
Prog Cardiovasc Dis ; 82: 135-146, 2024.
Article En | MEDLINE | ID: mdl-38242192

This comprehensive review highlights the significant advancements in Left Ventricular Assist Device (LVAD) therapy, emphasizing its evolution from the early pulsatile flow systems to the cutting-edge continuous-flow devices, particularly the HeartMate 3 (HM3) LVAD. These advancements have notably improved survival rates, reduced complications, and enhanced the quality of life (QoL) for patients with advanced heart failure. The dual role of LVADs, as a bridge-to-transplantation and destination therapy is discussed, highlighting the changing trends and policies in their application. The marked reduction in hemocompatibility-related adverse events (HRAE) with the HM3 LVAD, compared to previous models signifies ongoing progress in the field. Challenges such as managing major infections are discussed, including innovative solutions like energy transfer systems aimed at eliminating external drivelines. It explores various LVAD-associated complications, including HRAE, infections, hemodynamic-related adverse events, and cardiac arrhythmias, and underscores emerging strategies for predicting post-implantation outcomes, fostering a more individualized patient care approach. Tools such as the HM3 risk score are introduced for predicting survival based on pre-implant factors, along with advanced imaging techniques for improved complication prediction. Additionally, the review highlights potential new technologies and therapies in LVAD management, such as hemodynamic ramp tests for optimal speed adjustment and advanced remote monitoring systems. The goal is to automate LVAD speed adjustments based on real-time hemodynamic measurements, indicating a shift towards more effective, patient-centered therapy. The review concludes optimistically that ongoing research and potential future innovations hold the promise of revolutionizing heart failure management, paving the way for more effective and personalized treatment modalities.


Heart Failure , Heart Transplantation , Heart-Assist Devices , Humans , Quality of Life , Heart Failure/diagnosis , Heart Failure/therapy , Risk Factors , Heart-Assist Devices/adverse effects , Treatment Outcome
5.
J Heart Lung Transplant ; 43(4): 642-651, 2024 Apr.
Article En | MEDLINE | ID: mdl-38070663

BACKGROUND: The physiological response of the right ventricle (RV) following left ventricular assist device (LVAD) implantation is difficult to predict. We aimed to investigate RV geometric and functional changes after LVAD insertion and their effects on clinical outcomes. METHODS: We retrospectively reviewed 188 patients who underwent HeartMate 3 implantation at our center between November 2014 and September 2021. The RV end-diastolic diameter (RVEDD) and RV end-diastolic area (RVEDA) were measured on preoperative and predischarge transthoracic echocardiography. The nonadapted group included patients with increased RVEDD and RVEDA at discharge. The composite outcome was defined as death or readmission due to worsening right heart failure. RESULTS: There were 82 patients (44%) who had a nonadapted and 106 patients (56%) who had an adapted RV. Preoperatively, the nonadapted group had smaller RVEDD (46 vs 49 mm, p < 0.001) and RVEDA (27 vs 31 cm2, p < 0.001). At discharge, the nonadapted group had larger RVEDD (51 vs 43 mm, p < 0.001) and RVEDA (33 vs 27 cm2, p < 0.001). Kaplan-Meier analysis demonstrated worse 3-year survival (77% vs 91%, p = 0.006) and freedom from composite outcome (58% vs 85%, p < 0.001) in the nonadapted group. A multivariable Cox proportional hazards model showed that nonadaption (hazard ratio [HR] 3.09, 95% confidence interval [CI] 1.29-7.40, p = 0.01) and age (HR 3.73, 95% CI 1.42-9.77, p = 0.007) were independent predictors of composite outcome. CONCLUSIONS: Acute RV dimensional changes after LVAD insertion may represent intrinsic RV function and may be a useful prognostic marker.


Heart Failure , Heart-Assist Devices , Ventricular Dysfunction, Right , Humans , Heart Ventricles/diagnostic imaging , Retrospective Studies , Echocardiography , Ventricular Function, Right
6.
ASAIO J ; 70(4): e65-e68, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-37963291

Despite advances in our understanding of myocardial recovery among left ventricular assist device (LVAD) patients, with 10-30% of patients achieving substantial myocardial improvement, the rates of LVAD support cessation remain extremely low (1-2%). These numbers are in stark contrast to clinical trial data where successful LVAD cessation is reported in up to 47% of patients. The majority of LVAD programs lack structured recovery programs and targeted protocols, likely underscoring the heterogeneity that exists among LVAD patients with myocardial recovery. This perspective summarizes the current medical and surgical challenges with respect to 1) identifying the appropriate candidates for LVAD cessation; 2) methods to wean LVAD support; 3) reviewing surgical techniques for cessation of current generation HeartMate 3 LVAD; and 4) approaching shared decision making for LVAD cessation between patients and providers given the uncertainties that remain in the field.


Heart Failure , Heart-Assist Devices , Humans , Heart Failure/surgery , Goals
8.
J Card Fail ; 30(1): 95-99, 2024 Jan.
Article En | MEDLINE | ID: mdl-37625582

BACKGROUND: Aortic regurgitation (AR) is a common complication following left ventricular assist device (LVAD) implantation. We evaluated the hemodynamic implications of AR in patients with HeartMate 3 (HM3) LVAD at baseline and in response to speed changes. METHODS AND RESULTS: Clinically stable outpatients supported by HM3 who underwent a routine hemodynamic ramp test were retrospectively enrolled in this analysis. Patients were stratified based on the presence of at least mild AR at baseline speed. Hemodynamic and echocardiographic parameters were compared between the AR and non-AR groups. Sixty-two patients were identified. At the baseline LVAD speed, 29 patients (47%) had AR, while 33 patients (53%) did not. Patients with AR were older and supported on HM3 for a longer duration. At baseline speed, all hemodynamic parameters were similar between the groups including central venous pressure, pulmonary capillary wedge pressure, pulmonary arterial pressures, cardiac output and index, and pulmonary artery pulsatility index (p > 0.05 for all). During the subacute assessment, AR worsened in some, but not all, patients, with increases in LVAD speed. There were no significant differences in 1-year mortality or hospitalization rates between the groups, however, at 1-year, ≥ moderate AR and right ventricular failure (RVF) were detected in higher rates among the AR group compared to the non-AR group (45% vs. 0%; p < 0.01, and 75% vs. 36.8%; p = 0.02, respectively). CONCLUSIONS: In a cohort of stable outpatients supported with HM3 who underwent a routine hemodynamic ramp test, the presence of mild or greater AR did not impact the ability of HM3 LVADs to effectively unload the left ventricle during early subacute assessment. Although the presence of AR did not affect mortality and hospitalization rates, it resulted in higher rates of late hemodynamic-related events in the form of progressive AR and RVF.


Aortic Valve Insufficiency , Heart Failure , Heart-Assist Devices , Humans , Retrospective Studies , Heart Failure/diagnosis , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/etiology , Hemodynamics/physiology
9.
Clin Transplant ; 37(12): e15131, 2023 12.
Article En | MEDLINE | ID: mdl-37897211

INTRODUCTION: Monitoring for graft rejection is a fundamental tenet of post-transplant follow-up. In heart transplantation (HT) in particular, rejection has been traditionally assessed with endomyocardial biopsy (EMB). EMB has potential complications and noted limitations, including interobserver variability in interpretation. Additional tests, such as basic cardiac biomarkers, cardiac imaging, gene expression profiling (GEP) scores, donor-derived cell-free DNA (dd-cfDNA) and the novel molecular microscope diagnostic system (MMDx) have become critical tools in rejection surveillance beyond standard EMB. METHODS: This paper describes an illustrative case followed by a review of MMDx within the context of other noninvasive screening modalities for rejection. CONCLUSIONS: We suggest MMDx be used to assist with early detection of rejection in cases of discordance between EMB and other noninvasive studies.


Heart Transplantation , Myocardium , Humans , Myocardium/pathology , Heart Transplantation/adverse effects , Biopsy , Gene Expression Profiling , Graft Rejection/diagnosis , Graft Rejection/etiology , Graft Rejection/epidemiology
10.
Article En | MEDLINE | ID: mdl-37824209

OBJECTIVES: Lateral thoracotomy (LT) approach may preserve the right ventricular (RV) function after left ventricular assist device (LVAD) implantation. This study evaluated the short- and long-term RV function using echocardiography after LVAD implantation via LT or median sternotomy (sternotomy). METHODS: The patients who underwent HeartMate 3 implantation were retrospectively reviewed. The RV function was assessed before and 1 month and 1 year after LVAD implantation. The primary and secondary outcomes were all-cause mortality and a composite of death or readmission due to RV failure, respectively. RESULTS: Of the 195 patients, 55 (28%) underwent LT and 140 (72%) underwent sternotomy. There were no significant differences in the preoperative RV geometry or function. One month after the LVAD implantation, the LT group had a smaller RV end-diastolic dimension [42 (29-48) vs 47 (42-52) mm; P = 0.003] and RV end-diastolic area [25 (21-28) vs 29 (24-36) cm2; P < 0.001] and a greater RV fractional area change [30 (25-34)% vs 28 (23-31)%; P = 0.04] and peak systolic tissue velocity [8 (7-9) vs 7 (6-8) cm/s; P = 0.01]. Twenty-four patients died and 46 met the composite end point. Kaplan-Meier curve analysis did not reveal significant differences between LT and sternotomy in the 2-year survival (93% vs 83%; log-rank test, P = 0.28) and adverse event rate (76% vs 71%; log-rank test, P = 0.65). CONCLUSIONS: LT approach yielded a better-preserved RV function at 1 month; however, there were no significant differences in the 2-year survival and adverse event rates.

11.
Article En | MEDLINE | ID: mdl-37739242

BACKGROUND: Aortic root thrombosis(ART) is a complication of continuous-flow left ventricular assist device therapy. However, the incidence and related complications of ART in HeartMate 3 (HM3) patients remain unknown. METHODS: Patients who underwent HM3 implantation from November 2014 to August 2020 at a quaternary academic medical center were included. Demographics and outcomes were abstracted from the medical record. Echocardiograms and contrast-enhanced computed tomography studies were reviewed to identify patients who developed ART and/or moderate or greater aortic insufficiency (AI) on HM3 support. RESULTS: The study cohort included 197 HM3 patients with a median postimplant follow-up of 17.5 months. Nineteen patients (9.6%) developed ART during HM3 support, and 15 patients (7.6%) developed moderate or greater AI. Baseline age, gender, race, implantation strategy, and INTERMACS classification were similar between the ART and no-ART groups. ART was associated with an increased risk of death, stroke, or aortic valve (AV) intervention (subhazard ratio [SHR] 3.60 [95% confidence interval (CI) 1.71-7.56]; p = 0.001) and moderate or greater AI (SHR 11.1 [CI 3.60-34.1]; p < 0.001) but was not associated with a statistically significantly increased risk of death or stroke on HM3 support (2.12 [0.86-5.22]; p = 0.10). Of the 19 patients with ART, 6 (31.6%) developed moderate or greater AI, necessitating more frequent AV interventions (ART: 5 AV interventions [3 surgical repairs, 1 surgical replacement, 1 transcatheter replacement; 26.3%]; no-ART: 0). CONCLUSIONS: Nearly 10% of HM3 patients developed ART during device support. ART was associated with increased risk of a composite end-point of death, stroke, or AV intervention as well as moderate or greater AI.

12.
Am J Kidney Dis ; 82(5): 521-533, 2023 Nov.
Article En | MEDLINE | ID: mdl-37086965

RATIONALE & OBJECTIVE: The clinical implications of the discrepancy between cystatin C (cysC)- and serum creatinine (Scr)-estimated glomerular filtration rate (eGFR) in patients with heart failure (HF) and reduced ejection fraction (HFrEF) are unknown. STUDY DESIGN: Post-hoc analysis of randomized trial data. SETTING & PARTICIPANTS: 1,970 patients with HFrEF enrolled in PARADIGM-HF with available baseline cysC and Scr measurements. EXPOSURE: Intraindividual differences between eGFR based on cysC (eGFRcysC) and Scr (eGFRScr; eGFRdiffcysC-Scr). OUTCOMES: Clinical outcomes included the PARADIGM-HF primary end point (composite of cardiovascular [CV] mortality or HF hospitalization), CV mortality, all-cause mortality, and worsening kidney function. We also examined poor health-related quality of life (HRQoL), frailty, and worsening HF (WHF), defined as HF hospitalization, emergency department visit, or outpatient intensification of therapy between baseline and 8-month follow-up. ANALYTICAL APPROACH: Fine-Gray subdistribution hazard models and Cox proportional hazards models were used to regress clinical outcomes on baseline eGFRdiffcysC-Scr. Logistic regression was used to investigate the association of baseline eGFRdiffcysC-Scr with poor HRQoL and frailty. Linear regression models were used to assess the association of WHF with eGFRcysC, eGFRScr, and eGFRdiffcysC-Scr at 8-month follow-up. RESULTS: Baseline eGFRdiffcysC-Scr was higher than +10 and lower than-10mL/min/1.73m2 in 13.0% and 35.7% of patients, respectively. More negative values of eGFRdiffcysC-Scr were associated with worse outcomes ([sub]hazard ratio per standard deviation: PARADIGM-HF primary end point, 1.18; P=0.008; CV mortality, 1.34; P=0.001; all-cause mortality, 1.39; P<0.001; worsening kidney function, 1.31; P=0.05). For a 1-standard-deviation decrease in eGFRdiffcysC-Scr, the prevalences of poor HRQoL and frailty increased by 29% and 17%, respectively (P≤0.008). WHF was associated with a more pronounced decrease in eGFRcysC than in eGFRScr, resulting in a change in 8-month eGFRdiffcysC-Scr of-4.67mL/min/1.73m2 (P<0.001). LIMITATIONS: Lack of gold-standard assessment of kidney function. CONCLUSIONS: In patients with HFrEF, discrepancies between eGFRcysC and eGFRScr are common and are associated with clinical outcomes, HRQoL, and frailty. The decline in kidney function associated with WHF is more marked when assessed with eGFRcysC than with eGFRScr. PLAIN-LANGUAGE SUMMARY: Kidney function assessment traditionally relies on serum creatinine (Scr) to establish an estimated glomerular filtration rate (eGFR). However, this has been challenged with the introduction of an alternative marker, cystatin C (cysC). Muscle mass and nutritional status have differential effects on eGFR based on cysC (eGFRcysC) and Scr (eGFRScr). Among ambulatory patients with heart failure enrolled in PARADIGM-HF, we investigated the clinical significance of the difference between eGFRcysC and eGFRScr. More negative values (ie, eGFRScr>eGFRcysC) were associated with worse clinical outcomes (including mortality), poor quality of life, and frailty. In patients with progressive heart failure, which is characterized by muscle loss and poor nutritional status, the decline in kidney function was more pronounced when eGFR was estimated using cysC rather than Scr.

13.
Clin Transplant ; 37(5): e14974, 2023 05.
Article En | MEDLINE | ID: mdl-36938656

BACKGROUND: Heart transplantation (HT) is the gold standard therapy for advanced heart failure, providing excellent long-term outcomes. However, postoperative outcomes are limited by bleeding, infections, and primary graft dysfunction (PGD) that contribute to early mortality after HT. HT candidates with pre-existing hematologic disorders, bleeding, and clotting, may represent a higher risk population. We assessed the short- and long-term outcomes of patients with pre-existing hematologic disorders undergoing HT. METHODS AND RESULTS: Medical records of all adult patients who received HT from January 2010 to December 2019 at our institution were retrospectively reviewed. Hematologic disorders were identified via chart review and adjudicated by a board-certified hematologist. Inverse probability weighting and multivariable models were used to adjust for potential pretransplant confounders. Four hundred and ninety HT recipients were included, of whom 29 (5.9%) had a hematologic disorder. Hematologic disorders were associated with severe PGD requiring mechanical circulatory support (aOR 3.15 [1.01-9.86]; p = .049), postoperative infections (aOR 2.93 [1.38-6.23]; p = .01), and 3-year acute cellular rejection (ACR) (≥1R/1B) (aSHR 2.06 [1.09-3.87]; p = .03). There was no difference in in-hospital mortality (aOR 1.23 [.20-7.58], p = .82) or 3-year mortality (aHR 1.58 [.49-5.12], p = .44). CONCLUSIONS: Patients with hematologic disorders undergoing HT are at increased risk of severe PGD, postoperative infections, and ACR, while in-hospital and 3-year mortality remain unaffected.


Heart Failure , Heart Transplantation , Primary Graft Dysfunction , Adult , Humans , Retrospective Studies , Primary Graft Dysfunction/etiology , Heart Transplantation/adverse effects , Heart Failure/surgery , Morbidity , Risk Factors , Postoperative Complications/etiology
14.
J Heart Lung Transplant ; 42(6): 819-827, 2023 06.
Article En | MEDLINE | ID: mdl-36806438

BACKGROUND: Pulmonary function tests (PFT) are a frequent component of heart transplant evaluation. In cardiac surgery abnormal PFTs, especially reduced DLCO, have been associated with poor outcomes. We sought to evaluate the impact of pretransplant PFTs on post-transplant pulmonary outcomes and patient survival. METHODS: Among the 652 adult heart transplant recipients between January 1, 2010 and July 31, 2021, 462 had PFTs and constituted the patient cohort. Obstructive ventilatory defects (OVD), restrictive ventilatory defects (RVD), and reduced DLCO were defined according to established criteria. The primary outcome was the combined endpoint of a post-transplant pulmonary complication defined as reintubation, postoperative pneumonia, prolonged intubation, or tracheostomy. Secondary outcomes included 90-day all-cause mortality, length of stay, and the odds of individual pulmonary complications. Kaplan-Meier survival analysis, multivariable Cox proportional-hazards regression, and multivariable logistic regression were performed to compare outcomes between the groups. RESULTS: Patients with severe OVD (OR 1.48, 95% CI 1.18-5.23, p = 0.02) or severely reduced DLCO (OR 1.95, 95% CI 1.19-3.20, p = 0.008) had increased odds of post-transplant pulmonary complications. Following multivariable adjustment, severe OVD (aOR 2.67, 95% CI 1.15-6.19, p = 0.02) and severely reduced DLCO (aOR 1.79, 95% CI 1.05-3.04) remained strongly associated with post-transplant pulmonary complications. Patients with any degree of extrinsic RVD, moderate or less OVD, or moderately reduced DLCO or less did not have increased odds of post-transplant pulmonary complications. Ninety-day post-transplant survival was significantly reduced for both severe OVD (97.2% vs 86.5%, p = 0.04) and severely reduced DLCO (97.3% vs 90.4%, p = 0.004). Post-transplant ICU and hospital length of stay were nominally longer for both groups as well. CONCLUSIONS: Severe OVD or severely reduced DLCO on preheart transplant PFTs were associated with increased odds of post-transplant pulmonary complications and early mortality.


Pneumonia , Respiratory Insufficiency , Adult , Humans , Lung , Spirometry , Respiratory Function Tests , Retrospective Studies
15.
J Heart Lung Transplant ; 42(1): 124-133, 2023 01.
Article En | MEDLINE | ID: mdl-36272893

BACKGROUND: Following the MOMENTUM 3 trial and the discontinuation of the HeartWare HVAD, the HeartMate 3 LVAD (HM 3) has become the main durable device for bridging to transplantation; however, outcome of this strategy in the new heart allocation system is not well understood. METHODS: The United Network for Organ Sharing (UNOS) registry was queried to include adult patients (≥18 years old) listed for heart transplantation between 2010 and 2020. Trends in durable LVAD utilization and outcomes of patients with HM 3 LVAD were examined in the pre- vs post-heart allocation system. RESULTS: From 2017 to 2020, there was a 28.3% decline in the number of patients waitlisted with an FDA-approved durable LVAD. Overall, 449 patients were waitlisted with HM 3 in the pre-allocation era compared to 1094 patients in the post-allocation. Cumulative incidence of heart transplantation (53.4% vs 50.7%, p = 0.76) and death or delisting for worsening status (5.0%, vs 4.2%, p = 0.43) at 1-year after listing with HM 3 LVAD was comparable in the pre- vs post-allocation era. Old age (>50), ischemic HF, poor functional status, elevated creatinine (>1.3 mg/dL), pulmonary hypertension (>3 WU), and obesity (body mass index > 33 kg/m2) were predictors of post-transplant graft mortality after bridging with HM 3. CONCLUSIONS: While the utilization of durable devices as BTT have declined under the new heart allocation system, bridging with HM 3 LVAD remains a safe strategy in carefully selected patients. Bridging decision should be individualized based on patient risk factors.


Heart Failure , Heart Transplantation , Heart-Assist Devices , Hypertension, Pulmonary , Adult , Humans , Adolescent , Heart-Assist Devices/adverse effects , Heart Failure/surgery , Heart Failure/etiology , Heart Transplantation/adverse effects , Risk Factors , Hypertension, Pulmonary/etiology , Treatment Outcome , Retrospective Studies
16.
J Thorac Cardiovasc Surg ; 165(1): 168-182.e11, 2023 01.
Article En | MEDLINE | ID: mdl-33678503

BACKGROUND: Little is known regarding the profile of patients with multiorgan failure listed for simultaneous cardiac transplantation and secondary organ. In addition, few studies have reported how these patients are bridged with mechanical circulatory support (MCS). In this study, we examined national data of patients listed for multiorgan transplantation and their outcomes after bridging with or without MCS. METHODS: United Network for Organ Sharing data were reviewed for adult multiorgan transplantations from 1986 to 2019. Post-transplant patients and total waitlist listings were examined and stratified according to MCS status. Survival was assessed via Cox regression in the post-transplant cohort and Fine-Gray competing risk regression with transplantation as a competing risk in the waitlist cohort. RESULTS: There were 4534 waitlist patients for multiorgan transplant during the study period, of whom 2117 received multiorgan transplants. There was no significant difference in post-transplant survival between the MCS types and those without MCS in the whole cohort and heart-kidney subgroup. Fine-Gray competing risk regression showed that patients bridged with extracorporeal membrane oxygenation had significantly greater waitlist mortality compared with those without MCS when controlling for preoperative characteristics (subdistribution hazard ratio, 2.27; 95% confidence interval, 1.48-3.47; P < .001), whereas those bridged with a ventricular assist device had a decreased incidence of death compared with those without MCS (subdistribution hazard ratio, 0.78; 95% confidence interval, 0.63-0.96; P = .017). CONCLUSIONS: MCS, as currently applied, does not appear to compromise the survival of multiorgan heart transplant patients. Waitlist data show that extracorporeal membrane oxygenation patients have profoundly worse survival irrespective of preoperative factors including organ type listed. Survival on the waitlist for multiorgan transplant has improved across device eras.


Extracorporeal Membrane Oxygenation , Heart Failure , Heart Transplantation , Heart-Assist Devices , Adult , Humans , Treatment Outcome , Heart Transplantation/adverse effects , Waiting Lists , Retrospective Studies , Heart Failure/surgery
17.
Pharmacotherapy ; 42(9): 697-706, 2022 09.
Article En | MEDLINE | ID: mdl-35979678

STUDY OBJECTIVE: Mycophenolate mofetil (MMF) is the gold-standard immunosuppressive agent in heart transplantation (HT), but dose-dependent toxicities (e.g., neutropenia) are frequent. Gut bacteria ß-d-glucuronidases (GUS) modulate MMF bioavailability, and changes in the intestinal flora may influence the pharmacokinetics of MMF. The objective of this study was to evaluate the safety and efficacy of MMF 1.5 g every 12 h (q12) [high-dose, HD] versus 1 g q12 [low-dose, LD] and explore the association between neutropenia and GUS. MEASUREMENTS: We compared the incidence of acute cellular rejection (ACR) and neutropenia during the first 6 months post-HT. The association between neutropenia and GUS was investigated in an exploratory analysis on a subset of patients with prospectively collected stool data. Stool samples were analyzed using 16S rRNA sequencing. MAIN RESULTS: A total of 168 patients (120 MMF-HD, 48 MMF-LD; mean age 55.7 years, 79% male) were studied. Neutropenia occurred in 38.6% of patients at a median of 106 [64-143] days. Freedom from neutropenia was lower in MMF-HD compared with MMF-LD (57% vs. 73%, p = 0.03). ACR (≥1R/1B) occurred in 37.5% of patients at a median of 20 [10-96] days, while high-grade ACR (≥2R/3A) occurred in 11.3% at a median of 14 [9-89] days. Freedom from ACR was similar between groups. MMF-LD was associated with more high-grade ACR (hazard ratio [HR] 3.47, 95% confidence interval [CI] 1.09-11.08, p = 0.03) during the first month, but less neutropenia (HR 0.54, 95% CI 0.29-1.00, p = 0.05) between 1 and 6 months. GUS-producing bacteria were more abundant in neutropenic patients. CONCLUSIONS: MMF-LD was associated with higher rates of early high-grade ACR and lower rates of later neutropenia. Further studies are warranted to test whether temporal MMF dose adjustments and gut microbial composition could improve clinical outcomes post-HT.


Heart Transplantation , Kidney Transplantation , Neutropenia , Female , Graft Rejection/prevention & control , Heart Transplantation/adverse effects , Humans , Immunosuppressive Agents/adverse effects , Male , Middle Aged , Mycophenolic Acid/adverse effects , Neutropenia/chemically induced , Neutropenia/epidemiology , RNA, Ribosomal, 16S
18.
ESC Heart Fail ; 9(5): 3139-3148, 2022 10.
Article En | MEDLINE | ID: mdl-35762103

AIMS: Acute heart failure (HF) is associated with muscle mass loss, potentially leading to overestimation of kidney function using serum creatinine-based estimated glomerular filtration rate (eGFRsCr ). Cystatin C-based eGFR (eGFRCysC ) is less muscle mass dependent. Changes in the difference between eGFRCysC and eGFRsCr may reflect muscle mass loss. We investigated the difference between eGFRCysC and eGFRsCr and its association with clinical outcomes in acute HF patients. METHODS AND RESULTS: A post hoc analysis was performed in 841 patients enrolled in three trials: Diuretic Optimization Strategy Evaluation (DOSE), Renal Optimization Strategies Evaluation (ROSE), and Cardiorenal Rescue Study in Acute Decompensated Heart Failure (CARRESS-HF). Intra-individual differences between eGFRs (eGFRdiff ) were calculated as eGFRCysC -eGFRsCr at serial time points during HF admission. We investigated associations of (i) change in eGFRdiff between baseline and day 3 or 4 with readmission-free survival up to day 60; (ii) index hospitalization length of stay (LOS) and readmission with eGFRdiff at day 60. eGFRCysC reclassified 40% of samples to more advanced kidney dysfunction. Median eGFRdiff was -4 [-11 to 1.5] mL/min/1.73 m2 at baseline, became more negative during admission and remained significantly different at day 60. The change in eGFRdiff between baseline and day 3 or 4 was associated with readmission-free survival (adjusted hazard ratio per standard deviation decrease in eGFRdiff : 1.14, P = 0.035). Longer index hospitalization LOS and readmission were associated with more negative eGFRdiff at day 60 (both P ≤ 0.026 in adjusted models). CONCLUSIONS: In acute HF, a marked difference between eGFRCysC and eGFRsCr is present at baseline, becomes more pronounced during hospitalization, and is sustained at 60 day follow-up. The change in eGFRdiff during HF admission and eGFRdiff at day 60 are associated with clinical outcomes.


Cystatin C , Heart Failure , Humans , Creatinine , Glomerular Filtration Rate , Heart Failure/complications , Kidney
19.
Clin Transplant ; 36(9): e14761, 2022 09.
Article En | MEDLINE | ID: mdl-35730923

BACKGROUND: As cardiac re-transplantation is associated with inferior outcomes compared with primary transplantation, allocating scarce resources to appropriate re-transplant candidates is important. The aim of this study is to elucidate the factors associated with 1-year mortality in cardiac re-transplantation using the random forests algorithm for survival analysis. METHODS: We retrospectively reviewed the United Network for Organ Sharing registry and identified all adult (> 17 years old) recipients who underwent cardiac re-transplantation between January 2000 and March 2020. The random forest algorithm on Cox modeling was used to calculate the variable importance (VIMP) of independent variables for contributing to 1-year mortality. RESULTS: A total of 1294 patients underwent cardiac re-transplantation. Of these, 137 patients were re-transplanted within 1 year of their first transplant, while 1157 patients were re-transplanted more than 1 year after their first transplant. One-year mortality was significantly higher for patients receiving early transplantation compared with those receiving late transplantation (Early 40.6% vs. Late 13.6%, log-rank P < .001). Machine learning analysis showed that total bilirubin (> 2 mg/dl) (VIMP, 2.99%) was an independent predictor of 1-year mortality after early re-transplant. High BMI (> 30.0 kg/m2 ) (VIMP, 1.43%) and ventilator dependence (VIMP, 1.47%) were independent predictors of 1-year mortality for the late re-transplantation group. CONCLUSION: Machine learning showed that optimal 1-year survival following cardiac re-transplantation was significantly related to liver function in early re-transplantation, and to obesity and preoperative ventilator dependence in late re-transplantation.


Heart Transplantation , Adolescent , Adult , Bilirubin , Humans , Machine Learning , Retrospective Studies , Survival Analysis
20.
Clin Transplant ; 36(7): e14705, 2022 07.
Article En | MEDLINE | ID: mdl-35545895

INTRODUCTION: Venous thromboembolism (VTE), such as deep vein thrombosis (DVT) and pulmonary embolism (PE), is an important and serious postoperative complication after heart transplantation. We sought to characterize in-hospital VTE after heart transplantation and its association with clinical outcomes. METHOD: Adult (≧18 years) patients undergoing heart transplantation from 2015 to 2019 at our center were retrospectively reviewed. Post-transplant VTE was defined as newly diagnosed venous system thrombus by imaging studies. RESULTS: There were 254 patients. The cohort's median age was 55 years. A total of 61 patients were diagnosed with VTE, including one with right atrial thrombus, 54 with upper extremity DVT in which one patient subsequently developed PE, four with lower extremity DVT, and two with upper and lower extremity DVT. The cumulative incidence of VTE was 42% at 60-days of post heart transplant. Patients with VTE had longer hospital stay (P < .001), higher in-hospital mortality (P = .010), and worse 5-year survival (P = .009). On the multivariable Cox analysis, history of DVT/PE and intubation for more than 3 days were associated with an increased risk of in hospital VTE. CONCLUSION: The incidence of VTE in heart transplant recipients is high. Post-transplant surveillance, and appropriate preventive measures and treatment strategies after diagnosis are warranted.


Heart Transplantation , Pulmonary Embolism , Venous Thromboembolism , Venous Thrombosis , Adult , Heart Transplantation/adverse effects , Humans , Incidence , Middle Aged , Pulmonary Embolism/epidemiology , Pulmonary Embolism/etiology , Retrospective Studies , Risk Factors , Venous Thromboembolism/epidemiology , Venous Thromboembolism/etiology , Venous Thrombosis/complications , Venous Thrombosis/etiology
...