Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Gynecol Oncol ; 185: 101-107, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38377761

RESUMEN

OBJECTIVE: To assess the health state utilities of ovarian cancer patients, clinicians, and non-cancer controls regarding surgical complications in ovarian cancer. METHODS: Utilities for 14 surgical complications were assessed from patients with recently diagnosed or recurrent ovarian cancer, clinicians, and non-cancer controls using the visual analog scale (VAS) and time trade-off (TTO) methods. Health state utilities were converted to a 0-to-1 scale, where 0 represents the least favorable outcome and 1 represents the most favorable outcome. RESULTS: Fifty patients, 50 clinicians, and 50 controls participated. Median VAS scores were lower than TTO scores across all groups (p < 0.01). Patients viewed 'bleeding requiring transfusion' most favorably (VAS utility 0.75), followed in order by less favorable utility scores for hernia, thromboembolism, pleural effusion, abscess, ileus/bowel obstruction, wound infection, bowel obstruction requiring surgery, anastomotic leak requiring drain, temporary ostomy, anastomotic leak requiring surgery, genito-urinary fistula, permanent ostomy, and genito-intestinal fistula (VAS utility 0.2). Overall, clinicians perceived complications more favorably than patients by VAS (overall utility score 0.49 vs 0.43, p < 0.01), but not by the TTO. There were no differences in overall utility scores between patients and controls. Patients who had not experienced certain surgical complications had less favorable scores than patients who did (utility score for ostomy = 0.2 for patients without ostomy vs. 0.7 for patients with ostomy, p = 0.02). CONCLUSIONS: This study establishes health state utilities for surgical complications associated with ovarian cancer. These utilities can be used in future cost-effectiveness evaluations to determine quality-adjusted outcomes and may help in counseling patients during the shared decision-making process.


Asunto(s)
Neoplasias Ováricas , Complicaciones Posoperatorias , Calidad de Vida , Humanos , Femenino , Neoplasias Ováricas/cirugía , Neoplasias Ováricas/psicología , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Anciano , Adulto , Estudios de Casos y Controles
2.
J Immunol Methods ; 435: 68-76, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27220271

RESUMEN

Immunogenicity can impact PK, PD, efficacy and safety of biopharmaceuticals, and is often evaluated as a secondary objective in clinical studies. Methods to detect anti-drug antibodies (ADA) and neutralizing ADA (NAb) are semi-quantitative and utilize cut points to determine positive or negative samples. Assay cut points are established by the statistical analysis of treatment-naïve subject specimens that are assumed ADA and NAb-negative. Pre-existing antibodies to various biopharmaceuticals have been observed in treatment-naïve subjects and may artificially elevate the cut point, resulting in compromised assay sensitivities, inaccuracy in immunogenicity reporting and ultimately misleading assessment of the impact of immunogenicity on clinical outcomes. Although several approaches such as removal of pre-existing antibody samples or increasing the sample dilution could be used for cut point establishment to mitigate impact of pre-existing antibodies, they each have limitations, especially when a high prevalence of pre-existing antibodies is observed. Here we describe an innovative approach used to establish cut points for ADA and NAb assays of moxetumomab pasudotox (moxetumomab), a recombinant anti-CD22 immunotoxin, to which a high prevalence of pre-existing antibodies was observed. In order to overcome the challenges associated with this high prevalence and prevent establishment of an artificially elevated cut point, we developed an immunoinhibition approach that allowed generation of pseudo ADA and NAb-negative populations for cut point determination. Immunoinhibition was performed by adding excess moxetumomab (for ADA) or a non-CD22 binding PE38-containing immunotoxin, CAT-5001 (for NAb), to treatment-naive samples prior to evaluating samples for cut point establishment. This approach successfully eliminated pre-existing antibody activity in treatment-naive samples, enabling establishment of more accurate ADA and NAb assay cut points. A comparative analysis of the clinical immunogenicity results using cut points derived with immunoinhibition and without immunoinhibition (conventional method) demonstrated that the immunoinhibition approach markedly improved detection sensitivity and accuracy of immunogenicity characterization in patient samples. This innovative approach provides an alternative, practical solution for immunogenicity assay cut point establishment when biopharmaceuticals have a high prevalence of pre-existing antibodies.


Asunto(s)
Anticuerpos/sangre , Toxinas Bacterianas/inmunología , Biofarmacia/métodos , Exotoxinas/inmunología , Inmunoensayo/métodos , Anticuerpos/inmunología , Anticuerpos Neutralizantes/sangre , Anticuerpos Neutralizantes/inmunología , Humanos
3.
Cytometry B Clin Cytom ; 90(2): 128-40, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26332491

RESUMEN

BACKGROUND: Receptor occupancy (RO) assays measure drug target engagement, and are used as pharmacodynamic (PD) biomarkers. RO assays are commonly performed by flow cytometry and often require multiplexing for assessment of multiple PD biomarkers when specimen volumes are limited. We present multiplexed RO assays for an IGF1R-EGFR bispecific antibody (Bs-Ab) and a CTLA4-Ig recombinant fusion protein to demonstrate key considerations for accurate RO assessment. METHODS: RO in cynomolgus monkeys was determined in whole blood using flow cytometry. Free and total receptors were measured using anti-receptor fluorescence-labeled detection reagents, competitive and noncompetitive to drug, respectively. RESULTS: RO of IGF1R was examined as PD for Bs-Ab, since IGF1R was expressed on blood cells. Multiplexed measurements of free and total IGF1R showed that IGF1R expression measured by total receptor was highly variable, impacting interpretation of free-IGF1R. Normalization of free-over-total IGF1R measurements compensated for variability of receptor expression allowing for accurate RO assessment. RO of CTLA4-Ig, a recombinant fusion protein targeting CD80 and CD86 receptors, was multiplexed to simultaneously measure target engagements for both receptors. Both RO methods demonstrated specificity of receptor measurements without cross-reactivity to each other in multiplexed formats. RO methods were used for evaluation of PD activity of Bs-Ab and CTLA4-Ig in cynomolgus monkeys. In both cases, RO results showed dose-dependent target engagement, corresponding well to the pharmacokinetics. CONCLUSIONS: Multiplexed RO methods allowed accurate assessment of PD activity for Bs-Ab and CTLA4-Ig, facilitating development of these biopharmaceuticals from preclinical to clinical stages.


Asunto(s)
Anticuerpos Biespecíficos/inmunología , Receptores ErbB/inmunología , Citometría de Flujo , Receptores de Somatomedina/inmunología , Anticuerpos Biespecíficos/uso terapéutico , Antígeno B7-1/inmunología , Antígeno B7-1/uso terapéutico , Biomarcadores , Antígeno CTLA-4/inmunología , Receptores ErbB/uso terapéutico , Humanos , Inmunoconjugados/inmunología , Inmunosupresores/inmunología , Inmunosupresores/farmacocinética , Inmunosupresores/uso terapéutico , Receptor IGF Tipo 1 , Receptores de Somatomedina/uso terapéutico , Proteínas Recombinantes de Fusión/inmunología , Proteínas Recombinantes de Fusión/uso terapéutico
4.
Cytometry B Clin Cytom ; 90(2): 117-27, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26054054

RESUMEN

Receptor occupancy (RO) assays are designed to quantify the binding of therapeutics to their targets on the cell surface and are frequently used to generate pharmacodynamic (PD) biomarker data in nonclinical and clinical studies of biopharmaceuticals. When combined with the pharmacokinetic (PK) profile, RO data can establish PKPD relationships, which are crucial for informing dose decisions. RO is commonly measured by flow cytometry on fresh blood specimens and is subject to numerous technical and logistical challenges. To ensure that reliable and high quality results are generated from RO assays, careful assay design, key reagent characterization, data normalization/reporting, and thorough planning for implementation are of critical importance during development. In this article, the authors share their experiences and perspectives in these areas and discuss challenges and potential solutions when developing and implementing a flow cytometry-based RO method in support of biopharmaceutical drug development.


Asunto(s)
Biomarcadores/análisis , Descubrimiento de Drogas , Citometría de Flujo/métodos , Humanos , Farmacocinética
5.
J Patient Saf ; 9(1): 8-12, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23007243

RESUMEN

BACKGROUND: Unsafe injection practices in health-care settings often result in notification of potentially affected patients, to disclose the error and recommend blood-borne pathogens testing. Few studies have assessed public perceptions and preferences for patient notification. METHODS: Six focus groups were conducted during Fall 2009, with residents of Atlanta, GA, and New York City, NY. Questions focused on preferences for receiving health information, knowledge of safe injection practices, and responses to and preferences for a patient notification letter. A mixed-method analysis was performed for qualitative themes and descriptive statistics. RESULTS: A total of 53 individuals participated; only 2 had ever heard of the term safe injection practices. After identification of unsafe injection practices, participants preferred to be notified via telephone, letter/mailing, email, or face-to-face from the facility where the incident occurred. More than 25 different types of information were mentioned as elements to be placed in a patient notification letter including: corrective actions by the facility, course of action for the patient, assurance of medical coverage, and how it happened/reason for the incident. Participants preferred that the tone of the letter be empathetic; nearly all indicated it was "very likely" that they would seek testing if notified. CONCLUSIONS: Facilities and health departments should strive to assure the notification process is conducted swiftly, clearly guiding affected patients to the necessary course of action. Notification letters are not "one size fits all," and some preferences expressed by patients may not be feasible in all situations. Prevention efforts should be complemented by research on improving effective patient communications when unsafe injection practices necessitate patient notification.


Asunto(s)
Patógenos Transmitidos por la Sangre , Revelación , Control de Infecciones , Inyecciones , Errores Médicos , Prioridad del Paciente , Anciano , Femenino , Grupos Focales , Georgia , Humanos , Masculino , Persona de Mediana Edad , Ciudad de Nueva York , Investigación Cualitativa
6.
Infect Control Hosp Epidemiol ; 33(9): 945-8, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22869270

RESUMEN

To understand the feasibility of implementing a standardized performance measure for collecting and reporting influenza vaccination rates among healthcare personnel, qualitative, semistructured interviews were conducted with key informants in 32 healthcare facilities. Despite practical and logistical challenges to implementing the measure, respondents perceived clear benefits to its use.


Asunto(s)
Actitud del Personal de Salud , Encuestas de Atención de la Salud/normas , Personal de Salud , Gripe Humana/prevención & control , Aceptación de la Atención de Salud/estadística & datos numéricos , Vacunación/estadística & datos numéricos , Humanos , Entrevistas como Asunto , Investigación Cualitativa , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...