Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
J Am Coll Cardiol ; 84(1): 61-74, 2024 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-38864538

RESUMEN

BACKGROUND: The ADVENT randomized trial revealed no significant difference in 1-year freedom from atrial arrhythmias (AA) between thermal (radiofrequency/cryoballoon) and pulsed field ablation (PFA). However, recent studies indicate that the postablation AA burden is a better predictor of clinical outcomes than the dichotomous endpoint of 30-second AA recurrence. OBJECTIVES: The goal of this study was to determine: 1) the impact of postablation AA burden on outcomes; and 2) the effect of ablation modality on AA burden. METHODS: In ADVENT, symptomatic drug-refractory patients with paroxysmal atrial fibrillation underwent PFA or thermal ablation. Postablation transtelephonic electrocardiogram monitor recordings were collected weekly or for symptoms, and 72-hour Holters were at 6 and 12 months. AA burden was calculated from percentage AA on Holters and transtelephonic electrocardiogram monitors. Quality-of-life assessments were at baseline and 12 months. RESULTS: From 593 randomized patients (299 PFA, 294 thermal), using aggregate PFA/thermal data, an AA burden exceeding 0.1% was associated with a significantly reduced quality of life and an increase in clinical interventions: redo ablation, cardioversion, and hospitalization. There were more patients with residual AA burden <0.1% with PFA than thermal ablation (OR: 1.5; 95% CI: 1.0-2.3; P = 0.04). Evaluation of outcomes by baseline demographics revealed that patients with prior failed class I/III antiarrhythmic drugs had less residual AA burden after PFA compared to thermal ablation (OR: 2.5; 95% CI: 1.4-4.3; P = 0.002); patients receiving only class II/IV antiarrhythmic drugs pre-ablation had no difference in AA burden between ablation groups. CONCLUSIONS: Compared with thermal ablation, PFA more often resulted in an AA burden less than the clinically significant threshold of 0.1% burden. (The FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation [ADVENT]; NCT04612244).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/terapia , Fibrilación Atrial/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Calidad de Vida , Resultado del Tratamiento
2.
Artículo en Inglés | MEDLINE | ID: mdl-38869507

RESUMEN

BACKGROUND: Autonomic denervation is an ancillary phenomenon during thermal ablation of atrial fibrillation (AF), that may have synergistic effects on symptomatic improvement and long-term freedom from AF. Pulsed field ablation (PFA), a nonthermal ablation modality, was noninferior to thermal ablation in treating AF; however, PFA's relative myocardial selectivity may minimize autonomic effects. OBJECTIVES: This study sought to compare heart rate (HR) and heart rate variability (HRV) metrics as markers of autonomic function after ablation using PFA vs thermal ablation. METHODS: ADVENT (The FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation) was a randomized pivotal study comparing PFA (pentaspline catheter) with thermal ablation (radiofrequency [RF] or cryoballoon [CB]) for treating paroxysmal AF. Baseline HR was acquired from a pre-ablation 12-lead electrocardiogram, whereas follow-up HRs, as well as HRV (standard deviation of all normal to normal RR intervals, standard deviation of 5-minute average RR intervals) metrics, were derived from 72-hour Holter monitors at 6 and 12 months. RESULTS: This study included 379 paroxysmal AF patients undergoing PFA (n = 194) or thermal ablation (n = 185; n = 102 RF, n = 83 CB) completing 6- and 12-month Holter monitoring. Compared with PFA, thermal patients had significantly greater increases in HR from baseline to 6 months (ΔHR; 10.1 vs 5.9 beats/min; P = 0.02) and 12 months (ΔHR; 8.8 vs 5.2 beats/min; P = 0.03). This increase in HR at 6 and 12 months was similar between CB and RF (P = 0.94 and 0.83, respectively). HRV, both standard deviation of all normal to normal RR intervals and standard deviation of 5-minute average RR intervals, were significantly lower at both 6 and 12 months after thermal ablation compared with PFA (P < 0.01). CONCLUSIONS: PFA's effect on the autonomic nervous system was attenuated compared with thermal ablation. Whether this affects long-term freedom from AF or symptomatic bradycardia/pauses after AF ablation requires further study.

3.
Heart Rhythm ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38823667

RESUMEN

BACKGROUND: Atrial fibrillation (AF) ablation carries the risk of silent cerebral event (SCE) and silent cerebral lesion (SCL). Although "silent," these may have long-term clinical implications and are challenging to study as postprocedural magnetic resonance imaging (MRI) is not standard of care. OBJECTIVE: The neurological assessment subgroup (NAS) of ADVENT compared cerebral effects of pulsed field ablation (PFA) with standard-of-care thermal ablation. METHODS: The NAS included consecutive randomized PFA and thermal ablation patients who received postprocedural brain MRI 12-48 hours after ablation. Patients with apparent SCE or SCL findings underwent a modified Rankin scale assessment. MRI images were subsequently reviewed by a blinded brain imaging core laboratory. RESULTS: In total, 77 patients with paroxysmal AF were enrolled at 6 centers; 71 had analyzable scans (34 PFA; 37 thermal ablation). Through individual center review, 6 PFA and 4 thermal scans were identified as SCE/SCL positive, of which 3 PFA and 0 thermal SCE/SCL findings were confirmed by a blinded core laboratory. MRI findings revealed 1 patient with 2- to 4-mm SCEs, 1 patient with a 3-mm SCE, and 1 patient with 2 SCLs (5.5 mm and 11 mm). All modified Rankin scale and National Institutes of Health Stroke Scale scores were 0 before discharge and at 90-day follow-up. There were only 2 neurological safety events (1 transient ischemic attack [PFA] and 1 stroke [thermal ablation]) in the ADVENT study, neither of which was part of the NAS. CONCLUSION: The ADVENT trial provides the first prospective, randomized data on the cerebral impact of PFA and thermal ablation of AF. Incidence of SCE/SCL after ablation in the NAS was low.

4.
Am Surg ; : 31348241248810, 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38872622

RESUMEN

BACKGROUND: Many complex abdominal hernias are referred to tertiary academic institutions for evaluation and treatment. The purpose of this study was to compare clinical outcomes from complex abdominal hernia repairs and abdominal wall reconstructions at a community hospital vs high volume academic centers participating in Abdominal Core Health Quality Collaborative (ACHQC). METHODS: Patients undergoing elective complex abdominal hernia repair were identified in our community setting and treated between 2016 and 2019. These results were then compared to Academic centers in the ACHQC database. Complex hernia definition was limited to those who have undergone any myofascial advancement procedure for homogeneity. Informed consent was obtained, and study was IRB approved. All data was de-identified. RESULTS: A total of 180 patients underwent complex abdominal hernia repair at our community hospital. The ACHQC database identified 6299 patients meeting criteria at participating academic centers. Demographics were similar between the two groups including hernia grade, size and wound class. Academic centers tended to have patients with previous component separations (25.7% vs 10.6%) and immunosuppressed (7.2% vs 2.8%), while the community hospital patients included more patients with tobacco use (18.9% vs 12.1%) and hypertension (65% vs 54.9%). Operative times were significantly less at the community hospital, patients requiring >240 minutes of time for repair at academic centers (39.6% vs 5%). Postoperatively length of stay was significantly shorter at the community hospital group averaging 3.7 days vs academic centers of 6 days (P < .05). Although overall complications were less in the community hospital group (26.5% vs 19.4%). Readmission within 30 days was nearly twice as frequent in the community hospital group (14.4% vs 7.7%). CONCLUSION: Community hospitals can provide comparable care and surgical expertise as major academic centers in regard to complex hernias in a large majority of cases. There is a need for dedicated care coordination and continuous review of supporting staff and outcomes is necessary to assure quality care. There is still a need to identify which patients would benefit from treatment at an academic center as opposed to a community hospital in order to maximize patient access and outcomes at both types of hospital setting. Further investigation needs to be performed regarding criteria for which patients should be transferred to academic centers for their complex hernia care. Identifying patients who would benefit from treatment at Academic Centers as opposed to Community hospitals should continue to be investigated.

5.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38646926

RESUMEN

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Femenino , Masculino , Recurrencia , Europa (Continente) , Persona de Mediana Edad
6.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38340118

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Sistema de Registros , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Europa (Continente) , Resultado del Tratamiento , Recurrencia , Reoperación/estadística & datos numéricos
7.
JACC Clin Electrophysiol ; 10(5): 885-896, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38385916

RESUMEN

BACKGROUND: In treating atrial fibrillation, pulsed-field ablation (PFA) has comparable efficacy to conventional thermal ablation, but with important safety advantages: no esophageal injury or pulmonary vein stenosis, and rare phrenic nerve injury. However, when PFA is delivered in proximity to coronary arteries using a pentaspline catheter, which generates a broad electrical field, severe vasospasm can be provoked. OBJECTIVES: The authors sought to study the vasospastic potential of a focal PFA catheter with a narrower electrical field and develop a preventive strategy with nitroglycerin. METHODS: During atrial fibrillation ablation, a focal PFA catheter was used for cavotricuspid isthmus ablation. Angiography of the right coronary artery (some with fractional flow reserve measurement) was performed before, during, and after PFA. Beyond no nitroglycerin (n = 5), and a few testing strategies (n = 8), 2 primary nitroglycerin administration strategies were studied: 1) multiple boluses (3-2 mg every 2 min) into the right atrium (n = 10), and 2) a bolus (3 mg) into the right atrium with continuous peripheral intravenous infusion (1 mg/min; n = 10). RESULTS: Without nitroglycerin, cavotricuspid isthmus ablation provoked moderate-severe vasospasm in 4 of 5 (80%) patients (fractional flow reserve 0.71 ± 0.08). With repetitive nitroglycerin boluses, severe spasm did not occur, and mild-moderate vasospasm occurred in only 2 of 10 (20%). Using the bolus + infusion strategy, severe and mild-moderate spasm occurred in 1 and 3 of 10 patients (aggregate 40%). No patient had ST-segment changes. CONCLUSIONS: Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Vasoespasmo Coronario , Nitroglicerina , Humanos , Fibrilación Atrial/cirugía , Nitroglicerina/administración & dosificación , Nitroglicerina/uso terapéutico , Vasoespasmo Coronario/prevención & control , Masculino , Persona de Mediana Edad , Femenino , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Anciano , Vasodilatadores/uso terapéutico , Vasodilatadores/administración & dosificación , Angiografía Coronaria , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/cirugía , Vasos Coronarios/fisiopatología
8.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38305503

RESUMEN

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Estenosis de Vena Pulmonar , Humanos , Venas Pulmonares/cirugía , Constricción Patológica/complicaciones , Constricción Patológica/cirugía , Método Simple Ciego , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología
9.
Clin Chim Acta ; 550: 117583, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37802207

RESUMEN

BACKGROUND AND AIMS: Quinolinic acid (QA) is a metabolite of the kynurenine pathway, which is activated by inflammatory stimuli during viral infection. We investigated the role of QA in patients infected with SARS-CoV-2, particularly its prognostic value for survival. METHODS: Overall, 104 unvaccinated inpatients were included, divided into a survival (N = 80) and a deceased group (N = 24). Plasma levels of tryptophan, kynurenine, QA, C-reactive protein (CRP) and procalcitonin (PCT) were measured on admission and after seven days. The QA/TRP ratio and the relative differences between the measurements for QA (QA-Diff) and QA/TRP (Diff-QA/TRP) were calculated. RESULTS: Among the kynurenine pathway markers, QA-Diff showed the highest discriminatory power for the survival prognosis (Youden index 0.467, cut-off -1.3 %, AUC 0.733, p < 0.001, sensitivity 0.79, specificity 0.675). Among the inflammatory markers, CRP showed the highest discriminatory power (Youden index 0.533, cut-off 25.0 mg/L, AUC 0.794, p < 0.001, sensitivity 0.958, specificity 0.575). A significant correlation between QA and PCT was found on admission and after one week (Spearman's rho 0.455 and 0.539, all p-values < 0.001). CONCLUSIONS: QA may serve as prognostic marker for survival in patients with SARS-CoV-2. The repeated measurements during the first week of the disease may enhance the prognostic power.


Asunto(s)
COVID-19 , Quinurenina , Humanos , Quinurenina/metabolismo , Ácido Quinolínico/metabolismo , SARS-CoV-2 , COVID-19/diagnóstico , Triptófano/metabolismo , Proteína C-Reactiva/metabolismo , Polipéptido alfa Relacionado con Calcitonina
10.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37634148

RESUMEN

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/clasificación , Fibrilación Atrial/cirugía , Teorema de Bayes , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia , Método Simple Ciego , Taquicardia/etiología , Resultado del Tratamiento
11.
Clin Lab ; 69(8)2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37560847

RESUMEN

BACKGROUND: Next-generation sequencing (NGS) methods have become more commonly performed in clinical and research laboratories. METHODS: This review summarizes the current laboratory NGS-based diagnostic approaches in pharmacogenomics including targeted multi-gene panel sequencing, whole-exome sequencing (WES), and whole-genome sequencing (WGS). RESULTS: Clinical laboratories perform multiple non-uniform types of pharmacogenetic panels, which can reduce the overall number of single-gene tests to be more cost-efficient. Compared to the targeted multi-gene panels, which are not typically designed to detect novel variants, WES and WGS have a greater potential to identify secondary pharmacogenomic findings, which might be predictive for the pharmacotherapy outcome of different patient settings. WGS overcomes the limitations of WES enabling a more accurate exome-sequencing at appropriate coverage and the sequencing of non-coding regions. Different NGS-based study designs with different test strategies and study populations, varying sample sizes, and distinct analytical and interpretation procedures lead to different identification results of pharmacogenomic variants. CONCLUSIONS: The rapid progress in gene sequencing technologies will overcome the clinical and laboratory challenges of WES and WGS. Further high throughput NGS-based pharmacogenomics studies in different populations and patient settings are necessary to expand knowledge about rare functional variants and to enhance translation in clinical practice.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento , Farmacogenética , Humanos , Secuenciación de Nucleótidos de Alto Rendimiento/métodos
12.
Ecol Evol ; 13(7): e10266, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37435022

RESUMEN

Understanding how natural selection acts on the genome and contributes to the process of speciation is a primary aim of the study of evolution. Here we used natural variation in two subspecies of the Guadeloupean anole (Anolis marmoratus ssp.), from the island of Guadeloupe in the Lesser Antilles, to explore the genomic basis of adaptation and speciation in Anolis lizards. These subspecies inhabit distinct ecological environments and display marked differences in adult male color and pattern. We sequenced the complete genomes of 20 anoles, 10 from each subspecies, at 1.4× coverage. We used genome-wide scans of population differentiation, allele frequency spectrum, and linkage disequilibrium to characterize the genomic architecture within and between the subspecies. While most of the genome was undifferentiated, we observed five large divergent regions. Within these regions we identified blocks, 5 kb pairs in length, enriched for fixed single nucleotide polymorphisms. These blocks encompass 97 genes, two of which are candidate pigmentation genes. One is melanophilin (mlph), which helps transport melanosomes within melanocytes. The other is a cluster of differentiation 36 (cd36), which regulates carotenoid pigment sequestration. We used high-pressure liquid chromatography to confirm that carotenoid pigments are significantly more abundant in the conspicuous orange-pigmented skin of male A. m. marmoratus suggesting that cd36 may be regulating pigment deposition in this tissue. We identified for the first time a carotenoid gene that is a potential target of divergent sexual selection and may be contributing to the early stages of speciation in Anolis lizards.

13.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37379528

RESUMEN

AIMS: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. METHODS AND RESULTS: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. CONCLUSION: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Poria , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fluoroscopía , Venas Pulmonares/cirugía , Recurrencia
14.
Heart Rhythm O2 ; 4(5): 317-328, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37323994

RESUMEN

Background: Pulmonary vein isolation (PVI) is an effective treatment for paroxysmal atrial fibrillation (PAF). However, potential complications can occur due to the propagation of thermal energy into nontarget tissues adjacent to the targeted myocardium. Pulsed field ablation (PFA) is a novel ablation modality with the potential for preferential myocardial tissue ablation to minimize damage to collateral cardiac structures. A multielectrode pentaspline catheter has demonstrated safety and efficacy in treating PAF in single-arm, first-in-human studies. Objective: The study sought to perform a randomized clinical trial to directly compare this PFA catheter with conventional ablation-either radiofrequency or cryoballoon ablation. Methods: The ADVENT (Randomized Controlled Trial for Pulsed Field Ablation versus Standard of Care Ablation for Paroxysmal Atrial Fibrillation) trial is a multicenter, prospective, single-blind, randomized controlled trial to compare PVI using PFA vs conventional thermal ablation for drug-resistant PAF-with each site employing either (but not both) cryoballoon or radiofrequency ablation as a control condition. The sample size is adaptively determined based on Bayesian statistical methods. All patients will undergo PVI, and be followed for 12 months. Results: The primary effectiveness endpoint is a composite of acute procedural success and freedom from any documented atrial arrhythmia recurrence, repeat ablation, or use of antiarrhythmic drugs after a 3-month postablation blanking period. The primary safety endpoint is a composite of defined acute and chronic device- and procedure-related serious adverse events. Both primary endpoints will be evaluated for noninferiority of the novel PFA system compared with standard-of-care thermal ablation. Conclusions: By providing objective, comparative data, this study aims to scientifically determine whether the pentaspline PFA catheter is safe and effective for PVI ablation to treat drug-resistant PAF.

17.
Circ Arrhythm Electrophysiol ; 16(1): e011369, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36595634

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) has recently been shown to penetrate ischemic scar, but details on its efficacy, risk of arrhythmias, and imaging insights are lacking. In a porcine model of myocardial scar, we studied the ability of ventricular PFA to penetrate scarred tissue, induce ventricular arrhythmias, and assess the influence of QRS gating during pulse delivery. METHODS: Of a total of 6 swine, 5 underwent coronary occlusion and 1 underwent radiofrequency ablation to create infarct scar and iatrogenic scar models, respectively. Two additional swine served as healthy controls. An 8 Fr focal PFA catheter was used to deliver bipolar, biphasic PFA (2.0 kV) lesions guided by electroanatomical mapping, fluoroscopy, and intracardiac echocardiography over both scarred and healthy myocardium. Swine underwent magnetic resonance imaging 2-7 days post-PFA. RESULTS: PFA successfully penetrated scar without significant difference in lesion depth between lesion at the infarct border (5.9±1.0 mm, n=41) and healthy myocardium (5.7±1.3 mm, n=26; P=0.53). PFA penetration of both infarct and iatrogenic radiofrequency abalation scar was observed in all examined sections. Sustained ventricular arrhythmias requiring defibrillation occurred in 4 of 187 (2.1%) ungated applications, whereas no ventricular arrhythmias occurred during gated PFA applications (0 of 64 [0%]). Dark-blood late-gadolinium-enhanced sequences allowed for improved endocardial border detection as well as lesion boundaries compared with conventional bright-blood late-gadolinium-enhanced sequences. CONCLUSIONS: PFA penetrates infarct and iatrogenic scar successfully to create deep lesions. Gated delivery eliminates the occurrence of ventricular arrhythmias observed with ungated porcine PFA. Optimized magnetic resonance imaging sequences can be helpful in detecting lesion boundaries.


Asunto(s)
Ablación por Catéter , Infarto del Miocardio , Taquicardia Ventricular , Animales , Porcinos , Cicatriz , Gadolinio , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/cirugía , Electrofisiología Cardíaca , Enfermedad Iatrogénica , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía
18.
Clin Chim Acta ; 537: 77-79, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36279939

RESUMEN

BACKGROUND: The scale and the course of antibody production in patients with SARS-CoV-2 is highly variable. Factors involved in the immune regulation during the infection may play a major role in the antibody response. We investigated the relationship between the inflammatory markers of the kynurenine pathway and the concentration of antibodies against SARS-CoV-2 in infected patients 8 - 11 days after admission. METHODS: The study included 72 SARS-CoV-2 - positive inpatients hospitalized between August 2020 and April 2021. The plasma concentrations of tryptophan, kynurenine, anti-SARS-CoV-2 antibodies and the leucocyte count were measured 8 - 11 days after admission. The kynurenine/tryptophan ratio (KYN/TRP ratio) was calculated. Tertiles based on the values for tryptophan, kynurenine, KYN/TRP ratio and the leucocytes were generated. RESULTS: Statistically significant correlations were observed between anti-SARS-CoV-2 antibodies and tryptophan, kynurenine, KYN/TRP ratio and the leucocytes (p-values < 0.001-0.007). The high kynurenine and KYN/TRP ratio tertiles showed significantly lower antibody titers compared to the low tertiles (p-values 0.017 and < 0.001). The low tryptophan and leucocytes tertiles showed significantly lower antibody titers compared to the high tertiles (p-values 0.001 and 0.008). CONCLUSION: Patients with higher activation levels of the kynurenine pathway tended to develop lower anti-SARS-CoV-2 antibody titers.


Asunto(s)
COVID-19 , Quinurenina , Humanos , Quinurenina/metabolismo , Triptófano/metabolismo , Inmunidad Humoral , SARS-CoV-2
19.
J Reconstr Microsurg ; 38(6): 491-498, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34921370

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) has been widely used for perforator mapping in abdominal-based reconstruction, but it is less widespread in the anterolateral thigh (ALT) flap. However, CTA may be quite useful for ALT planning, as this flap has demonstrated substantial variability in intrapatient bilateral vascular anatomy. This study investigated whether standard use of preoperative CTA resulted in selection of the donor extremity with preferential perforator anatomy, and whether this affected operative time and postoperative outcomes. METHODS: A retrospective review of 105 patients who underwent proposed ALT flap reconstruction was performed. Seventy-nine patients received bilateral lower extremity CTAs, which were evaluated for dominant perforator anatomy (septocutaneous, musculoseptocutaneous, or musculocutaneous). Donor extremity selection was noted, and predicted perforator anatomy was compared with that encountered intraoperatively. RESULTS: Among the 73 patients who received bilateral imaging and ultimately received an ALT, congruent findings between imaging and surgical exploration were observed in 51 (69.8%) patients. Thirty (37.9%) patients had asymmetric perforator anatomy between their bilateral extremities on imaging. Among these, the leg with optimal perforator anatomy was selected in 70% of cases. There were no significant reductions among postoperative complication rates, but selection of the donor site with preferential anatomy was associated with a decrease in operative time (p = 0.049) among patients undergoing extremity reconstruction. CONCLUSION: CTA is a useful tool for optimizing donor site selection for ALT flaps and reducing operative time. We believe that standard use of preoperative CTA in ALTs warrants further consideration.


Asunto(s)
Colgajo Perforante , Procedimientos de Cirugía Plástica , Angiografía por Tomografía Computarizada , Humanos , Tempo Operativo , Colgajo Perforante/irrigación sanguínea , Cuidados Preoperatorios/métodos , Procedimientos de Cirugía Plástica/métodos , Colgajos Quirúrgicos/irrigación sanguínea , Muslo/irrigación sanguínea
20.
JACC Clin Electrophysiol ; 8(12): 1486-1496, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36779624

RESUMEN

BACKGROUND: The unique tissue selectivity of pulsed field ablation (PFA) allows for minimizing collateral damage to the nerves/esophagus. However, the safety profile of epicardial PFA on coronary arteries (CAs) has not been well defined. OBJECTIVES: This study sought to evaluate the effect of epicardial PFA directly on CAs in a swine model. METHODS: In 4 swine, an 8-F linear quadripolar PFA catheter (FARAPULSE Inc) was introduced into the pericardial space via a subxiphoid puncture. After coronary angiography (Angio), QRS synchronized, biphasic, bipolar PFA was delivered directly on the left anterior descending artery, left circumflex artery, or normal myocardium (control) (2.0 kV × 4 applications per site). Angio was repeated immediately after ablation and repeated every 5 minutes to quantify the degree of CA narrowing. After 4- or 8-week survival, repeat Angio was performed followed by gross and histologic lesion analyses. RESULTS: A total of 15 lesions were delivered (8 left anterior descending arteries, 3 left circumflexes, and 4 controls). Target site Angio revealed median of 47% (IQR: 38%-69%) acute luminal narrowing immediately after PFA, which gradually resolved over 30 minutes. Epicardial PFA lesions extended into the myocardium with a median depth of 4.1 mm (IQR: 3.6-5.6 mm) passing across the CAs and adipose tissue. However, 87.5% of the CAs demonstrated minimal to mild CA stenosis associated with neointimal hyperplasia and tunica media fibrosis. CONCLUSIONS: In a swine model, epicardial PFA directly on CAs allowed the creation of myocardial lesions but led to a CA response characterized by acute moderate spasm and chronic mild stenosis via neointimal hyperplasia.


Asunto(s)
Ablación por Catéter , Vasos Coronarios , Porcinos , Animales , Vasos Coronarios/cirugía , Constricción Patológica , Hiperplasia/patología , Ablación por Catéter/efectos adversos , Angiografía Coronaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...