Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
1.
Opt Express ; 32(4): 5252-5260, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38439257

RESUMEN

Although Sc doped AlN (ScAlN) has been used extensively in micro-electro-mechanical systems (MEMS) devices and more recently in optical devices, there have not been thorough studies of its intrinsic optical losses. Here we explore the optical losses of the Sc0.30Al0.70N waveguide system by observing racetrack resonator waveguide quality factors. Using a partial physical etch, we fabricate waveguides and extract propagation losses as low as 1.6 ± 0.3 dB/cm at wavelengths around 1550 nm, mostly dominated by intrinsic material absorption from the Sc0.30Al0.70N thin film layer. The highest quality factor of the resonators was greater than 87,000. The propagation loss value is lower than any value previously published and shows that this material can be broadly used in optical modulators without significant loss.

2.
Appl Opt ; 60(19): D43-D51, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34263827

RESUMEN

We present the inscription of narrow-linewidth fiber Bragg gratings (FBGs) into different types of multicore fibers (MCFs) using ultrashort laser pulses and the phase mask technique, which can act as notch filters. Such filters are required, e.g., to suppress light emitted by hydroxyl in the Earth's upper atmosphere, which disturbs ground-based observation of extraterrestrial objects in the near infrared. However, the inscription into a commercially available seven-core fiber showed a quite large core-to-core deviation of the resonance wavelength of up to 0.45 nm. Two options are presented to overcome this: first, we present the photo-treatment of the FBGs to tune the resonance wavelength, which allows for sufficient resonance shifts. Second, adapted MCFs containing 12 cores, arranged on a circle, are fabricated. For this, two different fabrication procedures were investigated, namely, the mechanical drilling of the preform for a rod-in-tube version as well as a stack-and-draw approach. Both adapted MCFs yielded significant improvements with core-to-core wavelength variations of the FBGs of only about 0.18 nm and 0.11 nm, respectively, sufficient to fulfill the requirements for astronomical filter applications as discussed above.

3.
Herzschrittmacherther Elektrophysiol ; 32(2): 244-249, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33977306

RESUMEN

BACKGROUND: Three-dimensional mapping systems and the use of ultra-low dose radiation protocols have supported minimization of radiation dose during left atrial ablation procedures. By using optimal shielding, scattered radiation reaching the operator can be further reduced. This prospective study was designed to determine the remaining operator radiation exposure during left atrial catheter ablations using real-time dosimetry. METHODS: Radiation dose was recorded using real-time digital dosimetry badges outside the lead apron during 201 consecutive left atrial fibrillation ablation procedures. All procedures were performed using the same X­ray system (Siemens Healthineers Artis dBc; Siemens Healthcare AG, Erlangen, Germany) programmed with ultra-low dose radiation settings including a low frame rate (two frames per second), maximum copper filtration, and an optimized detector dose. To reduce scattered radiation to the operators, table-suspended lead curtains, ceiling-suspended leaded plastic shields, and radiation-absorbing shields on the patient were positioned in an overlapping configuration. RESULTS: The 201 procedures included 139 (69%) pulmonary vein isolations (PVI) (20 cryoballoon ablations, 119 radiofrequency ablations, with 35 cases receiving additional ablation of the cavotricuspid isthmus) and 62 (31%) PVI plus further left atrial substrate ablation. Mean radiation dose measured as dose area product for all procedures was 128.09 ± 187.87 cGy ∙ cm2 with a mean fluoroscopy duration of 9.4 ± 8.7 min. Real-time dosimetry showed very low average operator doses of 0.52 ± 0.10 µSv. A subanalysis of 51 (25%) procedures showed that the radiation burden for the operator was highest during pulmonary vein angiography. CONCLUSION: The use of ultra-low dose radiation protocols in combination with optimized shielding results in extremely low scattered radiation reaching the operator.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Fluoroscopía , Alemania , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía
4.
Pneumologie ; 75(10): 761-775, 2021 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-33853133

RESUMEN

BACKGROUND: Demographic changes in the society and among doctors, as well as changing attitudes towards and norms of how living should be structured are creating challenges regarding the organization of work environment in the hospital. In addition, organization of medical training is increasingly being influenced by economic considerations as well as a high level of medical specialization. We asked young respiratory physicians how they assessed their current situation with respect to quality of medical training and organization of their work environment. METHODS: From September to November 2019, we performed an online survey adressing young respiratory physicians in Germany. Participants were recruited via three emails (baseline and reminders after 2 and 6 weeks) sent by the German Respiratory Society (DGP) and the German Union of Pulmonologists (BdP). The questionnaire consisted of a maximum of 62 questions. Apart from own questions that had been aligned with other questionnaires from similar surveys in other medical specialties, we also assessed the effort-reward ratio (ER ratio) based on the short version of the effort-reward imbalance questionnaire (16 questions). RESULTS: We recuited n = 224 participants (33.8 ±â€Š4.5 years, 5.4 ±â€Š2.9 years of medical training, 54.4 % female , 86.8 % with German nationality). A little under half of the interviewees (n = 103, 46 %) reported to be very or generally satisfied with their working conditions, while n = 60 (27 %) were unsure. The main reasons for not being satisfied were long working hours and high work-load, as well as a lack of streamlining the work environment in the hospital to the specific needs of doctors. Despite the fact that many participants were satisfied, a large majority (n = 166, 88.2 %) depicted an unfavorable effort-reward ratio imbalance (adjusted mean 1.89 ±â€Š2.18). CONCLUSION: Compared to many other European countries and internationally, the German healthcare system offers high-quality patient care and a well-equipped work environment. Increasing demands in the health care sector, however, are leading to a gratification crisis that not only harms the health and work performance of doctors but is also leading to reduced attractiveness of the job that might possibly lead to the search for new fields of activity or migration. Respiratory medicine is a discipline of growing interest and motivating young doctors to secure the promotion of this discipline is increasingly important. Factors harming the growth of this discipline should be immediately addressed. The results of this survey might help leaders in the field to restructure the work environment and medical education according to the actual needs.


Asunto(s)
Médicos , Neumólogos , Femenino , Alemania , Humanos , Satisfacción en el Trabajo , Masculino , Encuestas y Cuestionarios , Carga de Trabajo
5.
Opt Express ; 28(22): 33456-33474, 2020 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-33115008

RESUMEN

In this paper we present numerical and experimental results revealing that the mode instability threshold of highly Yb-doped, Ce/Al co-doped pedestal fibers is affected by the size of the index-increased pedestal structure surrounding the core. An alternative preparation technology for the realization of large mode area fibers with very large Al-doped silica pedestals is introduced. Three different pedestal fiber design iterations characterized by low photodarkening were manufactured and tested in counter-pumped amplifier setups. Up to 1.9 kW continuous-wave output power of near-diffraction-limited beam quality (M2 = 1.26) was achieved with an 18/200/420 µm fiber of very low NA = 0.042, limited only by the occurrence of mode instabilities.

6.
Opt Lett ; 43(7): 1519-1522, 2018 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-29601019

RESUMEN

We present a coherently combined laser amplifier with 16 channels from a multicore fiber in a proof-of-principle demonstration. Filled-aperture beam splitting and combination, together with temporal phasing, is realized in a compact and low-component-count setup. Combined average power of up to 70 W with 40 ps pulses is achieved with combination efficiencies around 80%.

7.
Opt Express ; 26(25): 32417-32432, 2018 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-30645409

RESUMEN

We present the application of a confocal fluorescence microscope to the analysis of Yb-doped solid-state laser materials, with examples of Yb-doped crystals, photonic crystal fibers and fiber preforms made with different manufacturing processes. Beside the fluorescence lifetime image itself, a microscopic spectral fluorescence emission analysis is presented and spatially resolved emission cross sections are obtained. Doping concentration and its distributions and other laser optical parameters are measured, which help to analyze manufacturing steps. Further properties like photodarkening and saturation are addressed.

8.
Opt Express ; 25(13): 14892-14899, 2017 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-28789071

RESUMEN

We investigate the average power scaling of two diode-pumped Yb-doped fiber amplifiers emitting a diffraction-limited beam. The first fiber under investigation with a core diameter of 30 µm was able to amplify a 10 W narrow linewidth seed laser up to 2.8 kW average output power before the onset of transverse mode instabilities (TMI). A further power scaling was achieved using a second fiber with a smaller core size (23µm), which allowed for a narrow linewidth output power of 3.5 kW limited by stimulated Brillouin scattering (SBS). We mitigated SBS using a spectral broadening mechanism, which allowed us to further increase the output power to 4.3 kW only limited by the available pump power. Up to this power level, a high slope efficiency of 90% with diffraction-limited beam quality and without any sign of TMI or stimulated Raman scattering for a spectral dynamic range of higher than -80 dB was obtained.

9.
Opt Express ; 25(4): 3006-3012, 2017 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-28241518

RESUMEN

We present modal content measurements (S2) of two different negative curvature hollow-core photonic crystal fibers: a kagome fiber and an ice cream cone fiber. Their sensitivity towards mode matching, bending and polarization is analyzed. For the kagome fiber, a higher order mode suppression of 17dB under optimal conditions was achieved, and for the ice cream cone fiber there was a suppression of up to 42dB. Polarization turned out to be a critical parameter for good higher order mode suppression in both fibers.

10.
Methods Enzymol ; 576: 361-78, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27480693

RESUMEN

The discovery of proteins with programmable DNA-binding specificities triggered a whole array of applications in synthetic biology, including genome editing, regulation of transcription, and epigenetic modifications. Among those, transcription activator-like effectors (TALEs) due to their natural function as transcription regulators, are especially well-suited for the development of orthogonal systems for the control of gene expression. We describe here the construction and testing of libraries of synthetic TALE-activated promoters which are under the control of a single TALE with a given DNA-binding specificity. These libraries consist of a fixed DNA-binding element for the TALE, a TATA box, and variable sequences of 19 bases upstream and 43 bases downstream of the DNA-binding element. These libraries were cloned using a Golden Gate cloning strategy making them usable as standard parts in a modular cloning system. The broad range of promoter activities detected and the versatility of these promoter libraries make them valuable tools for applications in the fine-tuning of expression in metabolic engineering projects or in the design and implementation of regulatory circuits.


Asunto(s)
Clonación Molecular/métodos , ADN/metabolismo , Ingeniería Metabólica/métodos , Plantas/genética , Regiones Promotoras Genéticas , Efectores Tipo Activadores de la Transcripción/metabolismo , Agrobacterium/genética , Agrobacterium/metabolismo , Secuencia de Bases , ADN/genética , Plantas/metabolismo , Biología Sintética/métodos , Efectores Tipo Activadores de la Transcripción/genética , Transformación Genética
11.
Opt Express ; 24(6): 6011-20, 2016 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-27136795

RESUMEN

We report on a newly designed and fabricated ytterbium-doped large mode area fiber with an extremely low NA (~0.04) and related systematic investigations on fiber parameters that crucially influence the mode instability threshold. The fiber is used to demonstrate a narrow linewidth, continuous wave, single mode fiber laser amplifier emitting a maximum output power of 3 kW at a wavelength of 1070 nm without reaching the mode-instability threshold. A high slope efficiency of 90 %, excellent beam quality, high temporal stability, and an ASE suppression of 70 dB could be reached with a signal linewidth of only 170 pm.

12.
Opt Lett ; 39(13): 3725-7, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24978721

RESUMEN

In this Letter, we demonstrate a single-mode continuous-wave fiber laser amplifier emitting 146 W of average output power at a wavelength of 1009 nm. The wavelength and bandwidth of the seed oscillator are defined by a pair of fiber Bragg gratings. The seed is amplified in a two-stage ytterbium-doped rod-type amplifier to 146 W with a high slope efficiency of 64%, showing excellent beam quality and stability throughout the experiment. The ASE suppression is as high as 63 dB.

13.
Toxicol In Vitro ; 26(6): 993-1000, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22579513

RESUMEN

Existing guidelines for testing developmental neurotoxicity (DNT) propose investigations in rodents, which are ethically questionable as well as time and cost intensive. Thus, there is international agreement that predictive in vitro methods are needed to increase efficiency of testing and limit the number of animals used. One of a variety of novel approaches for DNT testing utilizes neurospheres, three-dimensional aggregate cultures of primary normal neural progenitor cells (NPCs). Because sorting and plating of single neurospheres is one of the most time-consuming steps within the assay, the aim of this study was to evaluate if the complex object parametric analyzer and sorter (COPAS PLUS(TM), Union Biometrica Inc.) is a suitable tool for automated sorting and plating of neurospheres. The results of the comparison of NPC viability, proliferation, migration, differentiation and intracellular oxidative stress between manually and COPAS sorted and plated neurospheres of different species show that the automation by the COPAS instrument does not influence the basic performance of neurospheres. Therefore, we consider the COPAS instrument as a useful tool for higher throughput neurosphere research in toxicology, neuroregeneration, brain development, drug development and brain aging research.


Asunto(s)
Alternativas a las Pruebas en Animales , Ensayos Analíticos de Alto Rendimiento , Células-Madre Neurales/citología , Pruebas de Toxicidad/métodos , Animales , Diferenciación Celular , Movimiento Celular , Proliferación Celular , Supervivencia Celular , Células Cultivadas , Humanos , Ratones , Ratones Endogámicos C57BL , Células-Madre Neurales/metabolismo , Ratas , Ratas Wistar , Especies Reactivas de Oxígeno/metabolismo
14.
Opt Express ; 19(5): 4421-7, 2011 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-21369273

RESUMEN

In this paper we describe a high power narrow-band amplified spontaneous emission (ASE) light source at 1030 nm center wavelength generated in an Yb-doped fiber-based experimental setup. By cutting a small region out of a broadband ASE spectrum using two fiber Bragg gratings a strongly constrained bandwidth of 12±2 pm (3.5±0.6 GHz) is formed. A two-stage high power fiber amplifier system is used to boost the output power up to 697 W with a measured beam quality of M2≤1.34. In an additional experiment we demonstrate a stimulated Brillouin scattering (SBS) suppression of at least 17 dB (theoretically predicted ~20 dB), which is only limited by the dynamic range of the measurement and not by the onset of SBS when using the described light source. The presented narrow-band ASE source could be of great interest for brightness scaling applications by beam combination, where SBS is known as a limiting factor.


Asunto(s)
Amplificadores Electrónicos , Tecnología de Fibra Óptica/instrumentación , Rayos Láser , Refractometría/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
15.
Opt Express ; 19(27): 26742-51, 2011 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-22274258

RESUMEN

We report on the generation of high-energy pulses in an all normal dispersion photonic-crystal fiber laser. Two mode-locking techniques with and without passive spectral filtering are studied both numerically and experimentally to address a roadmap for energy scaling. It is found that high-contrast passive modulation is a very promising mode-locking technique for energy scaling in dissipative-soliton laser. Moreover, this technique does not need any additional spectral filtering than the limited gain bandwidth to stabilize high-energy ultrashort pulses. The presented laser generates 110 nJ chirped pulses at 57 MHz repetition rate for an average power of 6.2 W. The output pulses could be dechirped close to the transform-limited duration of 100 fs.


Asunto(s)
Amplificadores Electrónicos , Tecnología de Fibra Óptica/instrumentación , Rayos Láser , Oscilometría/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
16.
Br J Cancer ; 101(3): 381-6, 2009 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-19638986

RESUMEN

The cancer immunoediting hypothesis has gained significant footing over the past decade as a result of work performed using sarcomas induced by 3-methylcholanthrene (3-MCA) in mice. Despite the progress made by several groups in establishing evidence for the three phases of immunoediting (elimination, equilibrium and escape), there continues to be active controversy on the nature of interaction between spontaneously formed tumour cells and the immune system during the early phases of tumourigenesis. At the root of this controversy is conflicting and unresolved evidence spanning back to the 1970s regarding the incidence and frequency of 3-MCA-induced sarcomas in immunocompetent mice as compared to immunodeficient mice. In this mini review we provide a critical analysis of both sides of this controversy.


Asunto(s)
Vigilancia Inmunológica , Sarcoma Experimental/inmunología , Animales , Metilcolantreno , Ratones , Ratones Endogámicos C57BL , Subfamilia K de Receptores Similares a Lectina de Células NK/fisiología , Sarcoma Experimental/inducido químicamente
17.
Opt Lett ; 34(10): 1567-9, 2009 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-19448823

RESUMEN

We report on spectral combination of four high repetition rate 5 ns pulsed Yb-doped fiber amplifiers at 1 microm wavelength. The output beam is spatially and temporally superposed by use of an all-reflective diffraction grating. 1.1 kW average power and 220 microJ pulse energy were extracted with a combining efficiency of 99%.

18.
Opt Express ; 17(3): 1178-83, 2009 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-19188944

RESUMEN

We report on beam combining of four narrow-linewidth fiber amplifier chains, running at different wavelengths and each delivering 500 W optical output power. The main amplifier stage consists of a large mode area photonic crystal fiber. The four output beams of the amplifier chains are spectrally (incoherent) combined using a polarization-independent dielectric reflective diffraction grating to form an output beam of 2 kW continuous-wave optical power with good beam quality (M(2)x = 2.0, M(2)y = 1.8).

19.
Opt Express ; 17(25): 22974-82, 2009 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-20052223

RESUMEN

In this paper we introduce a simple scheme to spectrally combine four single beams using three low-cost dielectric interference filters as combining elements. 25 ns pulses from four independent and actively Q-switched fiber seed-sources are amplified in a single stage fiber-amplifier. Temporally and spatially combined 208 W of average power and 6.3 mJ of pulse energy are obtained at two different repetition frequencies. A detailed analysis of beam quality as well as the thermal behavior of the combining elements is carried out and reveals mutual dependency.


Asunto(s)
Amplificadores Electrónicos , Rayos Láser , Refractometría/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo
20.
Opt Express ; 16(3): 2122-8, 2008 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-18542292

RESUMEN

The generation of high-power and stable ultra-short pulses from a passively mode-locked purely normal dispersion fiber laser is reported using the unique combination of a photonic crystal fiber featuring single-polarization, single-mode, and low nonlinearity with a high modulation depth semiconductor saturable absorber mirror. The environmentally-stable, self-starting fiber laser generates 1.6 W of average power at a repetition rate of 63 MHz, corresponding to a pulse energy of 25 nJ. The emitted pulses are positively chirped with a pulse duration of 3.7 ps. They are compressible down to a near transform-limited duration of 750 fs. Numerical simulations are in good agreement with the experimental results.


Asunto(s)
Diseño Asistido por Computadora , Tecnología de Fibra Óptica/instrumentación , Rayos Láser , Modelos Teóricos , Refractometría/instrumentación , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...