Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
J Endocrinol Invest ; 44(11): 2359-2366, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33666874

RESUMEN

OBJECTIVES: To investigate whether adrenal volumetry provides better agreement with adrenal vein sampling (AVS) than conventional CT for subtyping PA. Furthermore, we evaluated whether the size of this contralateral adrenal was a prognostic factor for clinical outcome after unilateral adrenalectomy. METHODS: We retrospectively analyzed volumes of both adrenal glands of the 180 CT-scans (88/180 with unilateral and 92/180 with bilateral disease) of the patients with PA included in the SPARTACUS trial of which 85 also had undergone an AVS. In addition, we examined CT-scans of 20 healthy individuals to compare adrenal volumes with published normal values. RESULTS: Adrenal volume was higher for the left than the right adrenal (mean and SD: 6.49 ± 2.77 ml versus 5.25 ± 1.87 ml for the right adrenal; p < 0.001). Concordance between volumetry and AVS in subtyping was 58.8%, versus 51.8% between conventional CT results and AVS (p = NS). The volumes of the contralateral adrenals in the patients with unilateral disease (right 4.78 ± 1.37 ml; left 6.00 ± 2.73 ml) were higher than those of healthy controls reported in the literature (right 3.62 ± 1.23 ml p < 0.001; left 4.84 ± 1.67 ml p = 0.02). In a multivariable analysis the contralateral volume was not associated with biochemical or clinical success, nor with the defined daily doses of antihypertensive agents at 1 year follow-up. CONCLUSIONS: Volumetry of the adrenal glands is not superior to current assessment of adrenal size by CT for subtyping patients with PA. Furthermore, in patients with unilateral disease the size of the contralateral adrenal is enlarged but its size is not associated with outcome.


Asunto(s)
Glándulas Suprarrenales , Aldosterona/sangre , Tomografía Computarizada de Haz Cónico , Hiperaldosteronismo , Tomografía Computarizada por Rayos X , Glándulas Suprarrenales/irrigación sanguínea , Glándulas Suprarrenales/diagnóstico por imagen , Glándulas Suprarrenales/patología , Antihipertensivos/uso terapéutico , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada de Haz Cónico/estadística & datos numéricos , Correlación de Datos , Femenino , Humanos , Hiperaldosteronismo/sangre , Hiperaldosteronismo/clasificación , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/fisiopatología , Hipertensión/etiología , Hipertensión/terapia , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Tamaño de los Órganos , Pronóstico , Valores de Referencia , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos
2.
J Plast Reconstr Aesthet Surg ; 70(12): 1696-1701, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28882494

RESUMEN

BACKGROUND: The IDEAL framework aims at improving the evidence base of available surgical innovations. However, the development of such innovations and collection of evidence is costly. Surgical innovation can provide more value for money if innovations are evaluated at an early stage, where evaluations can inform the decision whether to stop or to further develop an innovation. We illustrate how decision modelling can be readily adopted at the earliest stages (0-1) of the IDEAL framework, using an innovation in bilateral DIEP flap breast reconstruction as an example. METHODS: We quantified expected costs and quality-adjusted life years (QALYs) of the current treatment and compared them with an innovation aimed at reducing complications and surgery time. The maximum effect of eliminating all complications (headroom analysis) was explored. Moreover, three scenarios with varying complications and surgery time reductions were modelled. Furthermore, the maximum price of the innovation was estimated in a threshold analysis according to its impact and societal willingness to pay. RESULTS: The headroom analysis showed that when all complications associated with the current treatment are prevented, up to €889 per patient is saved. Scenario analysis showed cost savings between €256 and €828 per patient. When surgery time is reduced by 15 min and complications by 50%, the innovation will remain cost-effective at €671 per patient. CONCLUSION: In a field struggling with cost containment, decision modelling can help to separate promising innovations from costly failures at an early stage. In this example, decision modelling showed that it seems worthwhile to further develop the innovation.


Asunto(s)
Técnicas de Apoyo para la Decisión , Mamoplastia/métodos , Colgajo Perforante , Ahorro de Costo , Difusión de Innovaciones , Medicina Basada en la Evidencia , Femenino , Humanos , Mamoplastia/economía , Mastectomía , Tempo Operativo , Colgajo Perforante/economía , Complicaciones Posoperatorias/economía , Complicaciones Posoperatorias/prevención & control , Años de Vida Ajustados por Calidad de Vida
3.
Ned Tijdschr Geneeskd ; 160: D288, 2016.
Artículo en Holandés | MEDLINE | ID: mdl-27827286

RESUMEN

Fibromuscular dysplasia (FMD) is a non-inflammatory, non-atherosclerotic vasculopathy that can lead to arterial stenosis, occlusion, aneurysms, and dissection. FMD of the renal arteries can lead to renovascular hypertension. Percutaneous angioplasty of the renal arteries (PTRA) can lead to normalization of blood pressure in 45% of patients with renal artery stenosis caused by FMD, particularly in younger patients and patients with a short history of hypertension. A considerable number of the patients with renovascular FMD also have cervical FMD, which can lead to ischaemic or haemorrhagic stroke. In this article we discuss diagnostic and therapeutic options, illustrated by two cases of patients with renovascular and carotid FMD. Most of the recommendations are based on data from retrospective studies and expert opinion; prospective studies on the optimal diagnostic strategy and treatment are therefore, urgently required.


Asunto(s)
Displasia Fibromuscular/complicaciones , Hipertensión/etiología , Humanos
4.
Ned Tijdschr Geneeskd ; 160: A9948, 2016.
Artículo en Holandés | MEDLINE | ID: mdl-27334082

RESUMEN

BACKGROUND: The incidence of hereditary haemorrhagic telangiectasia (HHT - Osler-Weber-Rendu disease) in the Netherlands is 1:5000 but approximately 1:1300 in people from the Antilles. The disease is characterised by the development of telangiectasia and arteriovenous malformations (AVMs) that may result in serious morbidity and mortality. CASE DESCRIPTION: A 31-year-old primigravid patient consulted her general practitioner at 31 1/7 weeks gestational age with dyspnoea. She was referred for further diagnostics because of suspected pulmonary embolism. A CT scan showed haemothorax and a bleeding arteriovenous malformation (AVM) in the left lung. Family history suggested the possibility of HHT. After multidisciplinary consideration, a primary caesarean section was performed, followed by embolisation of the AVM during the same surgical session. The patient had a gene mutation consistent with HHT type 2. CONCLUSION: Pregnant patients with HHT are at risk of serious morbidity, especially if they are not screened for AVMs. A multidisciplinary approach for such patients, with consideration of various scenarios, is highly recommended.


Asunto(s)
Malformaciones Arteriovenosas/genética , Hemotórax/genética , Complicaciones Cardiovasculares del Embarazo/genética , Telangiectasia Hemorrágica Hereditaria/complicaciones , Adulto , Femenino , Edad Gestacional , Humanos , Pulmón/irrigación sanguínea , Embarazo , Telangiectasia Hemorrágica Hereditaria/genética , Tomografía Computarizada por Rayos X
5.
J Plast Reconstr Aesthet Surg ; 69(3): 376-80, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26620253

RESUMEN

INTRODUCTION: Lymphedema of the arm is a common postoperative complication as a result of breast cancer surgery. One of the surgical treatments comprises modification of a deep inferior epigastric perforator (DIEP) flap breast reconstruction to facilitate additional lymph node transplantation from the inguinal area. Using computed tomography angiography (CTA), the distribution of these lymph nodes can be assessed. A virtual planning based on this CTA created for the DIEP flap is presented, with the inguinal lymph nodes included, followed by preoperatively projecting this information on the patient's abdomen. METHODS: A total of 10 patients underwent the standard imaging protocol: A preoperative CTA to assess the vascular anatomy of the lower abdomen. A three-dimensional (3D) model of the blood vessels was produced, and the inguinal lymph nodes in this reconstruction were included. Preoperative projection of the 3D model onto the patients' abdomen and inguinal area was performed, followed by tracing of this image. Intraoperatively found lymph nodes were identified by touch and compared with the markings on the skin. RESULTS: In all 10 patients, all lymph nodes located preoperatively were found intraoperatively within a 1-cm radius of the marking on the skin; and these were more easily located by two operating surgeons. CONCLUSION: Virtual planning of lymph node transplantations in a deep inferior epigastric artery perforator flap breast reconstruction seems feasible and can be performed quickly. This additional visual support aids the surgeon in locating the lymph nodes in the inguinal area.


Asunto(s)
Angiografía/métodos , Imagenología Tridimensional , Ganglios Linfáticos/diagnóstico por imagen , Linfedema/prevención & control , Mamoplastia/métodos , Colgajo Perforante/irrigación sanguínea , Pared Abdominal/irrigación sanguínea , Pared Abdominal/cirugía , Adulto , Brazo , Neoplasias de la Mama/cirugía , Estudios de Cohortes , Arterias Epigástricas/trasplante , Femenino , Humanos , Conducto Inguinal , Ganglios Linfáticos/irrigación sanguínea , Ganglios Linfáticos/cirugía , Mamoplastia/efectos adversos , Mastectomía/métodos , Persona de Mediana Edad , Colgajo Perforante/trasplante , Cuidados Preoperatorios/métodos , Pronóstico , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
6.
J Plast Reconstr Aesthet Surg ; 68(3): 390-4, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25498828

RESUMEN

INTRODUCTION: In a deep inferior epigastric perforator (DIEP) flap breast reconstruction, computed tomography angiography (CTA) is currently considered as the gold standard in preoperative imaging for this procedure. Unidirectional Doppler ultrasound (US) is frequently used; however, this method does not distinguish the main axial vessels from perforator arteries at the height of the fascia, it has a limited penetration depth, and it cannot assess the branching patterns of the deep inferior arteries. A new method and system were developed, which consisted of a video projector preoperatively displaying the location and intramuscular course of the artery perforators and subcutaneous branching on the patient's abdomen. METHOD: All patients (n=9) underwent a standard protocol: a preoperative CTA was performed and the DIEPs were localized using a unidirectional Doppler probe. In addition, a three-dimensional (3D) reconstruction of the perforator locations based on CTA was projected on the abdomen of the patients. All projected perforator locations were assessed using a unidirectional Doppler probe. The intraoperative results were collected for comparison. RESULTS: A total of 88 locations were marked with the use of unidirectional Doppler and a total of 100 perforators were projected (p=0.38). In 98 out of 100 projected perforator locations, a Doppler signal was audible. The intraoperative results demonstrate that 19 out of 34 transplanted perforators were correctly identified with unidirectional Doppler (56.9%±31.4%), where the projection method properly revealed 29 locations (84.3%±25.8%) (p=0.030). CONCLUSION: The projection method is not only capable of providing more information and identifying more perforators used for transplantation than unidirectional Doppler probing but also more accurate in pointing out the corresponding perforator found intraoperatively.


Asunto(s)
Mamoplastia/métodos , Colgajo Perforante/irrigación sanguínea , Cirugía Asistida por Computador , Ultrasonografía Doppler , Pared Abdominal/irrigación sanguínea , Arterias Epigástricas/trasplante , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Microcirugia/métodos , Tomografía Computarizada por Rayos X
7.
Br J Radiol ; 86(1030): 20130310, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23913308

RESUMEN

OBJECTIVE: To determine the accuracy of cone beam CT (CBCT) guidance and CT guidance in reaching small targets in relation to needle path complexity in a phantom. METHODS: CBCT guidance combines three-dimensional CBCT imaging with fluoroscopy overlay and needle planning software to provide real-time needle guidance. The accuracy of needle positioning, quantified as deviation from a target, was assessed for inplane, angulated and double angulated needle paths. Four interventional radiologists reached four targets along the three paths using CBCT and CT guidance. Accuracies were compared between CBCT and CT for each needle path and between the three approaches within both modalities. The effect of user experience in CBCT guidance was also assessed. RESULTS: Accuracies for CBCT were significantly better than CT for the double angulated needle path (2.2 vs 6.7 mm, p<0.001) for all radiologists. CBCT guidance showed no significant differences between the three approaches. For CT, deviations increased with increasing needle path complexity from 3.3 mm for the inplane placements to 4.4 mm (p=0.007) and 6.7 mm (p<0.001) for the angulated and double angulated CT-guided needle placements, respectively. For double angulated needle paths, experienced CBCT users showed consistently higher accuracies than trained users [1.8 mm (range 1.2-2.2) vs 3.3 mm (range 2.1-7.2) deviation from target, respectively; p=0.003]. CONCLUSION: In terms of accuracy, CBCT is the preferred modality, irrespective of the level of user experience, for more difficult guidance procedures requiring double angulated needle paths as in oncological interventions. ADVANCES IN KNOWLEDGE: Accuracy of CBCT guidance has not been discussed before. CBCT guidance allows accurate needle placement irrespective of needle path complexity. For angulated and double-angulated needle paths, CBCT is more accurate than CT guidance.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Fluoroscopía/métodos , Agujas , Tomografía Computarizada por Rayos X/métodos , Competencia Clínica , Humanos , Imagenología Tridimensional , Fantasmas de Imagen , Programas Informáticos
8.
J Cardiovasc Surg (Torino) ; 51(2): 253-6, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20354495

RESUMEN

AIM: Endovascular skills are an integral part of modern-day vascular surgery. The STRESS machine has been developed to test these skills in vascular surgeons. This study aims to define an optimal pass/fail cutoff value for the STRESS test score. METHODS: The STRESS machine consists of a dry glass model of the abdominal aorta and its tributaries with various stenotic lesions, elongations, and tortuosities. A camera and computer software are used to simulate plain fluoroscopy-mode. The test subjects are given two assignments after which two reviewers use a combination of the ICEPS and MRS to produce the final total score; 43 subjects were tested. According to previous endovascular experience, subjects were classified into four groups: novice-low (no experience, less than 11 performed procedures, less than 50 assisted procedures), novice-high (11-25 performed procedures, more than 50 assisted procedures), intermediate (1-10 performed and >11-25 assisted procedures, 11-25 performed and >1-10 assisted procedures or 25-50 performed procedures) and advanced (more than 50 performed procedures). RESULTS: Test-score and noted experience showed a correlation of 0.794. All intermediate and advanced test subjects scored more than 50 points compared to 4 out of 15 novices. CONCLUSION: We demonstrated that it is possible to determine an optimal cut-off value for competence testing with the STRESS machine.


Asunto(s)
Aorta Abdominal/cirugía , Enfermedades de la Aorta/cirugía , Competencia Clínica , Simulación por Computador , Destreza Motora , Evaluación de Resultado en la Atención de Salud , Procedimientos Quirúrgicos Vasculares , Aorta Abdominal/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Humanos , Radiografía , Reproducibilidad de los Resultados , Análisis y Desempeño de Tareas
9.
Neth Heart J ; 17(7-8): 284-7, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19789696

RESUMEN

An acute myocardial infarction is a rare complication of a subarachnoid haemorrhage. The combination of these two conditions imposes important treatment dilemmas. We describe two patients with this combination of life-threatening conditions. Patient 1 was treated with emergency percutaneous coronary intervention followed by clipping of the anterior communicating artery aneurysm. Six months after discharge the patient's memory and orientation had almost completely recovered. Patient 2 was treated with aspirin until coiling of the aneurysm could be performed. After successful coiling low-molecular-weight heparin was added. One week later the patient died due to a free wall rupture. (Neth Heart J 2009;17:284-7.).

10.
Eur J Vasc Endovasc Surg ; 38(6): 715-7, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19828338

RESUMEN

Angio-Seal is a frequently used vascular closure device after arterial catheterisation. Major complications are infrequently reported. We present four cases occurring within a 2-month period in our hospital with dislodgement of an Angio-Seal causing acute arterial occlusion, resulting in loss of limb in one case. Surgical intervention was necessary in all cases. Acute arterial occlusion after deployment of the Angio-Seal in patients with peripheral arterial disease might be less uncommon than the literature suggests.


Asunto(s)
Angioplastia de Balón , Arteriopatías Oclusivas/etiología , Migración de Cuerpo Extraño/etiología , Hemorragia/prevención & control , Técnicas Hemostáticas/efectos adversos , Isquemia/etiología , Extremidad Inferior/irrigación sanguínea , Enfermedades Vasculares Periféricas/terapia , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Amputación Quirúrgica , Angioplastia de Balón/efectos adversos , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/cirugía , Remoción de Dispositivos , Endarterectomía , Diseño de Equipo , Femenino , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/cirugía , Hemorragia/etiología , Técnicas Hemostáticas/instrumentación , Humanos , Isquemia/diagnóstico por imagen , Isquemia/cirugía , Masculino , Persona de Mediana Edad , Punciones , Radiografía , Reoperación , Trombectomía , Terapia Trombolítica , Resultado del Tratamiento
11.
Cardiovasc Intervent Radiol ; 32(1): 132-5, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18661174

RESUMEN

The purpose of this study was to assess the technical performance and immediate procedure outcome of a new balloon catheter in the treatment of calcified lesions in infrainguinal arterial disease. Seventy-five patients with infrainguinal arterial disease were prospectively entered into the registry. The catheter (ReeKross Clearstream, Ireland) is a 5- to 6-Fr balloon catheter with a rigid shaft intended for enhanced pushability. Only technical procedural outcome was recorded. Treated calcified lesions (range: 5-30 cm), assessed angiographically, were located in the superficial femoral, popliteal, and crural arteries. In 67 patients the lesion was an occlusion. Guidewire passage occurred subintimally in 68 patients. In 24 patients a standard balloon catheter was chosen as first treatment catheter: 5 failed to cross the lesion, 8 balloons ruptured, and in 11 patients there was an inadequate dilatation result. In only one of the five patients did subsequent use of the ReeKross catheter also fail in lesion crossing. The ReeKross was successful as secondary catheter in the other 23 cases. In 50 patients the ReeKross was used as primary catheter. In total the ReeKross crossed the lesions in 74 patients. After passage and dilatation with this catheter in 73 patients (1 failed true-lumen reentry), 19 had >30% residual lesions, of which 11 were not treated and 8 were successfully stented. No ReeKross balloons ruptured. We conclude that in the treatment of difficult calcified lesions in arterial stenotic or occlusive disease, the choice of a high-pushability angioplasty catheter, with more calcification-resistant balloon characteristics, like the ReeKross, warrants consideration.


Asunto(s)
Arteriopatías Oclusivas/terapia , Calcinosis/terapia , Cateterismo/instrumentación , Enfermedades Vasculares Periféricas/terapia , Angiografía , Arteria Femoral , Humanos , Arteria Poplítea , Estudios Prospectivos , Sistema de Registros , Stents , Resultado del Tratamiento
13.
Neth J Med ; 66(2): 81-4, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18292612

RESUMEN

Two adult patients with presumed primary hypertension are presented. In the first patient the diagnosis of coarctation of the aorta was straightforward while in the second patient there was a substantial delay in reaching the correct diagnosis. A 32-year-old patient was analysed for hypertension in the outpatient clinic. At physical examination a systolic cardiac murmur was present and leg blood pressure was not measurable. Magnetic resonance imaging angiography showed a severe coarctation of the thoracic aorta with extensive distended collateral blood vessels. A second patient was a 31-year-old man referred with longstanding hypertension and an unsatisfactory blood pressure response to treatment. Previously, a diagnosis of primary hypertension was made. Renal computed tomography angiography excluded renal artery stenosis as a cause of hypertension but disclosed many distended collateral blood vessels in the musculus rectus abdominis and in the upper abdominal area. Leg blood pressure was measured and further analysis revealed a coarctation of the aorta. Both patients illustrate and emphasise the importance of leg blood pressure measurement at a first analysis of adult hypertensive patients and should always be performed when hypertension is accompanied by murmurs or weak femoral pulsations.


Asunto(s)
Coartación Aórtica/diagnóstico , Determinación de la Presión Sanguínea/métodos , Hipertensión/diagnóstico , Pierna/irrigación sanguínea , Adulto , Humanos , Hipertensión/etiología , Masculino
14.
Ned Tijdschr Geneeskd ; 151(18): 1029-34, 2007 May 05.
Artículo en Holandés | MEDLINE | ID: mdl-17508690

RESUMEN

In 3 patients, men aged 60, 55 and 60, respectively, with hypertension due to primary hyperaldosteronism, the aldosterone level in the adrenal veins was determined for the purpose of further diagnosis. In two patients, unilateral adrenal enlargement on the CT-scan was accompanied by overproduction ofaldosterone, in one case in a non-enlarged adrenal gland and in the other case in both adrenals. The first patient underwent adrenalectomy of the non-enlarged adrenal gland, while in the second patient surgery was decided against. The third patient had bilateral adrenal gland enlargement on the CT-scan with a surgically treatable, unilateral overproduction ofaldosterone. Now that determination ofthe aldosterone:renin ratio in plasma as a screening method in selected patients with hypertension is being used more often, primary hyperaldosteronism turns out to be more common than was previously thought. For differentiation between unilateral and bilateral overproduction of aldosterone, imaging of the adrenals, for example with CT, is insufficiently accurate. Aldosterone determination in the adrenal veins can distinguish between unilateral and bilateral overproduction of aldosterone with great accuracy, which has important therapeutic consequences.


Asunto(s)
Adrenalectomía/métodos , Aldosterona/biosíntesis , Hiperaldosteronismo/complicaciones , Hiperaldosteronismo/diagnóstico , Hipertensión/etiología , Aldosterona/sangre , Diagnóstico Diferencial , Humanos , Hiperaldosteronismo/cirugía , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Venas
15.
Neth J Med ; 63(3): 81-90, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15813419

RESUMEN

This article presents a review of the treatment of lower-extremity deep venous thrombosis (DVT) with systemic and catheter-directed thrombolysis (CDT) and percutaneous mechanical thrombectomy (PMT). Standard treatment including anticoagulation therapy and compression stockings may not be entirely adequate, because a significant proportion of patients eventually develop post-thrombotic syndrome (PTS). Thrombolytic agents might offer a potential advantage because they cause faster and more complete clot resolution, which may reduce or prevent residual vein stenosis and valve damage. Thrombolytic therapy results in greater lysis, but also in higher complication rates than does anticoagulation alone. Major bleeding occurs in 11% of patients treated with thrombolytic therapy. The incidence of PTS tends to be lower in patients treated with thrombolytics. However, several methodological flaws limit the conclusions with respect to reduction in PTS. No adequate randomised controlled trials have been performed comparing CDT or PMT with conventional therapy. Given the current data, thrombolytic treatment, CDT or PMT should not be applied except in extraordinary cases. First, the long-term effectiveness in terms of reducing PTS, although possible, remains uncertain. Second, the risks of thrombolytic therapy and PMT are higher. Third, current conventional therapy is relatively inexpensive, convenient and safe.


Asunto(s)
Trombectomía/métodos , Terapia Trombolítica/métodos , Trombosis de la Vena/tratamiento farmacológico , Enfermedad Aguda , Cateterismo Periférico , Fibrinolíticos/uso terapéutico , Humanos , Resultado del Tratamiento
16.
Ned Tijdschr Geneeskd ; 148(26): 1297-300, 2004 Jun 26.
Artículo en Holandés | MEDLINE | ID: mdl-15279215

RESUMEN

A 4-year-old boy was hit by a car travelling at 40 km/h and was admitted 3.5 h later to the department of paediatric surgery. Because he was haemodynamically unstable and needed blood transfusion, the patient underwent an emergency operation. The liver was ruptured in the right lobe. A large haematoma was found in the serosa of the duodenum, along with a Meckel's diverticle, which was left in place. The liver rupture was covered and sealed. One month after the accident the patient was re-admitted, because of abdominal pain and gastrointestinal bleeding. The cause was thought to be the Meckel's diverticle, which was removed later. Two months after the trauma the patient was re-admitted with abdominal pain, again with haematemesis and melaena. The diagnosis of hemobilia was obtained with MRI and angiography, which revealed a ruptured pseudoaneurysm of the ramus dexter of the proper hepatic artery. The patient was successfully treated with embolization. The diagnostic delay was two months, which illustrates the importance of considering the possibility of the diagnosis hemobilia in case of gastrointestinal haemorrhage combined with biliary symptoms.


Asunto(s)
Accidentes de Tránsito , Hemobilia/diagnóstico , Hígado/lesiones , Preescolar , Embolización Terapéutica , Hemobilia/cirugía , Hemobilia/terapia , Humanos , Hígado/cirugía , Masculino , Rotura
17.
Eur J Surg Oncol ; 29(9): 757-63, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-14602496

RESUMEN

AIM: Isolated hepatic perfusion (IHP) is an invasive, technically difficult, non-repeatable and demanding operation. In this study we report the development of a less invasive alternative for the surgical IHP in a pig model. METHODS: Our technique was tested in 8 Yorkshire pigs (60 kg). The liver was isolated from the systemic circuit using minimally invasive techniques: an occlusion stent-graft and balloon catheters, with reversal of the blood flow through the liver during IHP. RESULTS: Tests with varying pressures applied at the PV revealed a clear relation between the suction pressure at the outflow site (PV), intrahepatic pressure and systemic leakage of 99mTc. A leakage-free IHP could be obtained in seven separate experiments. CONCLUSION: Isolated hepatic perfusion using minimally invasive techniques is feasible in pigs when the intrahepatic pressure is controlled. This technique has yet to be tested in patients.


Asunto(s)
Quimioterapia del Cáncer por Perfusión Regional , Neoplasias Hepáticas/tratamiento farmacológico , Animales , Modelos Animales de Enfermedad , Neoplasias Hepáticas/patología , Procedimientos Quirúrgicos Mínimamente Invasivos , Metástasis de la Neoplasia , Porcinos , Resultado del Tratamiento
18.
Eur J Cancer ; 39(8): 1068-73, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12736105

RESUMEN

Currently, breast cancer patients without clinically suspicious lymph nodes are candidates for sentinel lymph node procedures (SLNPs). The aims of this study were to investigate whether preoperative axillary ultrasonography and fine-needle aspiration cytology (FNA) can reduce the number of the more time-consuming SLNPs, and to identify a subset of quantitative nodal features to predict metastatic involvement. 268 axillae were ultrasonographically examined. FNA was performed on suspicious nodes (smallest diameter > or =5 mm or atypical cortex appearance). SLNP was omitted if a tumour-positive node was found on FNA. Length, width, maximum cortex thickness and appearance of cortex and hilus were ultrasonographically established. In 93 axillae (35%), at least one node was detected with ultrasound. FNA was performed once per axilla on 66 nodes; 37 (56%) contained tumour cells. 31% of all tumour-positive axillae (macro-+micrometastases) was found by ultrasound and FNA (37/121). 41% of all axillae containing macrometastases was found by ultrasound and FNA (36/87). SLNPs were reduced by 14% (37/268). Maximum cortex thickness is the main feature to predict metastatic involvement (area under Receiver Operating Characteristic (ROC) curve (A(Z))=0.87).


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Biopsia del Ganglio Linfático Centinela/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Axila , Biopsia con Aguja/métodos , Biopsia con Aguja/estadística & datos numéricos , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Femenino , Humanos , Escisión del Ganglio Linfático/métodos , Metástasis Linfática/diagnóstico por imagen , Persona de Mediana Edad , Cuidados Preoperatorios/métodos , Curva ROC , Ultrasonografía
19.
J Nephrol ; 16(6): 807-12, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14736007

RESUMEN

BACKGROUND: Atherosclerotic renal artery stenosis (ARAS) is associated with progressive loss of renal function and is one of the most important causes of renal failure in the elderly. Current treatment includes restoration of the renal arterial lumen by endovascular stent placement. However, this treatment only affects damage caused by ARAS due to the stenosis and ensuing post-stenotic ischemia. ARAS patients have severe general vascular disease. Atherosclerosis and hypertension can also damage the kidney parenchyma causing renal failure. Medical treatment focuses on the latter. Lipid-lowering drugs (statins) could reduce renal failure progression and could reduce the overall high cardiovascular risk. The additional effect on preserving renal function of stent placement as compared to medical therapy alone is unknown. Therefore, the STAR-study aims to compare the effects of renal artery stent placement together with medication vs. medication alone on renal function in ARAS patients. METHOD: Patients with an ARAS of > or = 50% and renal failure (creatinine (Cr) clearance < 80 mL/min/1.73 m2) are randomly assigned to stent placement with medication or to medication alone. Medication consists of statins, anti-hypertensive drugs and antiplatelet therapy. Patients are followed for 2 yrs with extended follow-up to 5 yrs. The primary outcome of this study is a reduction in Cr clearance > 20% compared to baseline. This trial will include 140 patients.


Asunto(s)
Antihipertensivos/uso terapéutico , Arteriosclerosis/terapia , Ácidos Heptanoicos/uso terapéutico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Pirroles/uso terapéutico , Obstrucción de la Arteria Renal/terapia , Arteria Renal , Stents , Angioplastia de Balón , Arteriosclerosis/complicaciones , Arteriosclerosis/fisiopatología , Atorvastatina , Terapia Combinada , Progresión de la Enfermedad , Humanos , Riñón/fisiopatología , Obstrucción de la Arteria Renal/etiología , Obstrucción de la Arteria Renal/fisiopatología , Proyectos de Investigación
20.
Invest Radiol ; 36(6): 347-53, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11410756

RESUMEN

RATIONALE AND OBJECTIVES: The aim of this study was to quantify the displacement of breast tissue and the inaccuracy of needle positioning for biopsy (14-gauge) and localization (19.5-gauge) needles. METHODS: For displacement of breast tissue, differences between the coordinates of identifiable microcalcifications in the images before (baseline) and after needle positioning were analyzed (n = 52). For accuracy of needle positioning, differences between the coordinates of the needle tip and the target were analyzed in breast tissue (n = 97) and in air (n = 246). RESULTS: Average target displacement was 2.1 mm for biopsy needles (95% prediction interval [PI] 0.6-7.8) and 1.0 mm (95% PI 0.3-3.9) for localization needles. Mean inaccuracy of needle positioning in breast tissue was 1.1 mm (95% PI 0.4-3.0) and 1.8 mm (95% PI 0.7-4.6) for biopsy and localization needles, respectively. CONCLUSIONS: Tissue and needle displacements cause a total positioning error of 2.4 mm in stereotactic core biopsy, which will limit the attainable diagnostic accuracy.


Asunto(s)
Biopsia con Aguja , Neoplasias de la Mama/patología , Mama/patología , Biopsia con Aguja/métodos , Neoplasias de la Mama/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Errores Diagnósticos , Femenino , Humanos , Mamografía , Movimiento , Técnicas Estereotáxicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA