Phys Imaging Radiat Oncol ; 31: 100618, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39188809

RESUMEN

Background and purpose: Squamous cell carcinoma of the anus (SCCA) can recur after chemoradiotherapy (CRT). Early prediction of treatment response is crucial for individualising treatment. Existing data on radiological biomarkers is limited and contradictory. We performed an individual patient data meta-analysis (IPM) of four prospective trials investigating whether diffusion-weighted (DW) magnetic resonance imaging (MRI) in weeks two to three of CRT predicts treatment failure in SCCA. Material and methods: Individual patient data from four trials, including paired DW-MRI at baseline and during CRT, were combined into one dataset. The association between ADC volume histogram parameters and treatment failure (locoregional and any failure) was assessed using logistic regression. Pre-defined analysis included categorising patients into a change in the mean ADC of the delineated tumour volume above and below 20%. Results: The study found that among all included 142 patients, 11.3 % (n = 16) had a locoregional treatment failure. An ADC mean change of <20 % and >20 % resulted in a locoregional failure rate of 16.7 % and 8.0 %, respectively. However, no other ADC-based histogram parameter was associated with locoregional or any treatment failure. Conclusions: DW-MRI standard parameters, as an isolated biomarker, were not found to be associated with increased odds of treatment failure in SCCA in this IPM. Radiological biomarker investigations involve multiple steps and can result in heterogeneous data. In future, it is crucial to include radiological biomarkers in large prospective trials to minimize heterogeneity and maximize learning.

2.
Eur J Radiol ; 178: 111642, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39079322

RESUMEN

PURPOSE: To benchmark image quality and corresponding radiation doses for acute abdominal CT examination across different laboratories and CT manufacturers. METHOD: An anthropomorphic phantom was scanned once with local abdominal CT protocols at 40 CT scanners, from four vendors, in thirty-three sites. Quantitative image quality was evaluated by CNR and SNR in the liver and kidney parenchyma. Qualitative image quality was assessed by visual grading analysis performed by three experienced radiologists using a five-point Likert scale to score thirteen image quality criteria. The CTDIvol was recorded for each scan. Pearson's correlation coefficient was calculated for the continuous variables, and the intraclass correlation coefficient was used to investigate interrater reliability between the radiologists. RESULTS: CTDIvol ranged from 3.5 to 12 mGy (median 5.3 mGy, third quartile 6.7 mGy). SNR in liver parenchyma ranged from 4.4 to 14.4 (median 8.5), and CNR ranged from 2.7 to 11.2 (median 6.1). A weak correlation was found between CTDIvol and CNR (r = 0.270, p = 0.092). Variations in CNR across scanners at the same dose level CTDIvol were observed. No significant difference in CTDIvol or CNR was found based on scanner installation year. The oldest scanners had a 15 % higher median CTDIvol and a 12 % lower median CNR. The ICC showed acceptable agreement for all dose groups: low (ICC=0.889), medium (ICC=0.767), high (ICC=0.847), and in low (ICC=0.803) and medium (ICC=0.811) CNR groups. CONCLUSION: There was large variation in radiation dose and image quality across the different CT scanners. Interestingly, the weak correlation between CTDIvol and CNR indicates that higher doses do not consistently improve CNR, indicating a need for systematic assessment and optimization of image quality and radiation doses for the abdominal CT examination.


Asunto(s)
Fantasmas de Imagen , Dosis de Radiación , Radiografía Abdominal , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Rayos X/métodos , Radiografía Abdominal/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Acta Radiol Open ; 13(5): 20584601241241523, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38645439

RESUMEN

Background: In staging early rectal cancers (ERC), submucosal tumor depth is one of the most important features determining the possibility of local excision (LE). The micro-enema (Bisacodyl) induces submucosal edema and may hypothetically improve the visualization of tumor depth. Purpose: To test the diagnostic performance of MRI to identify ERC suitable for LE when adding a pre-procedural micro-enema and concurrent use of a modified classification system. Material and Methods: In this prospective study, we consecutively included 73 patients with newly diagnosed rectal tumors. Two experienced radiologists independently interpreted the MRI examinations, and diagnostic performance was calculated for local tumors eligible for LE (Tis-T1sm2, n = 43) and non-local tumors too advanced for LE (T1sm3-T3b, n = 30). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were registered for each reader. Inter- and intra-reader agreements were assessed by kappa statistics. Lymph node status was derived from the clinical MRI reports. Results: Reader1/reader2 achieved sensitivities of 93%/86%, specificities of 90%/83%, PPV of 93%/88%, and NPV of 90%/81%, respectively, for identifying tumors eligible for LE. Rates of overstaging of local tumors were 7% and 14% for the two readers, and kappa values for the inter- and intra-reader agreement were 0.69 and 0.80, respectively. For tumors ≤T2, all metastatic lymph nodes were smaller than 3 mm on histopathology. Conclusion: MRI after a rectal micro-enema and concurrent use of a modified staging system achieved good diagnostic performance to identify tumors suitable for LE. The rate of overstaging of local tumors was comparable to results reported in previous endorectal ultrasound (ERUS) studies.

4.
J Appl Clin Med Phys ; 25(4): e14309, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38386922

RESUMEN

OBJECTIVE: This study identifies key characteristics to help build a physical liver computed tomography (CT) phantom for radiomics harmonization; particularly, the higher-order texture metrics. MATERIALS AND METHODS: CT scans of a radiomics phantom comprising of 18 novel 3D printed inserts with varying size, shape, and material combinations were acquired on a 64-slice CT scanner (Brilliance 64, Philips Healthcare). The images were acquired at 120 kV, 250 mAs, CTDIvol of 16.36 mGy, 2 mm slice thickness, and iterative noise-reduction reconstruction (iDose, Philips Healthcare, Andover, MA). Radiomics analysis was performed using the Cancer Imaging Phenomics Toolkit (CaPTk), following automated segmentation of 3D regions of interest (ROI) of the 18 inserts. The findings were compared to three additional ROI obtained of an anthropomorphic liver phantom, a patient liver CT scan, and a water phantom, at comparable imaging settings. Percentage difference in radiomic metrics values between phantom and tissue was used to assess the biological equivalency and <10% was used to claim equivalent. RESULTS: The HU for all 18 ROI from the phantom ranged from -30 to 120 which is within clinically observed HU range of the liver, showing that our phantom material (T3-6B) is representative of biological CT tissue densities (liver) with >50% radiomic features having <10% difference from liver tissue. Based on the assessment of the Neighborhood Gray Tone Difference Matrix (NGTDM) metrics it is evident that the water phantom ROI show extreme values compared to the ROIs from the phantom. This result may further reinforce the difference between a structureless quantity such as water HU values and tissue HU values found in liver. CONCLUSION: The 3-D printed patterns of the constructed radiomics phantom cover a wide span of liver tissue textures seen in CT images. Using our results, texture metrics can be selectively harmonized to establish clinically relevant and reliable radiomics panels.


Asunto(s)
Radiómica , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Tomógrafos Computarizados por Rayos X , Fantasmas de Imagen , Hígado/diagnóstico por imagen , Agua , Procesamiento de Imagen Asistido por Computador/métodos
6.
J Appl Clin Med Phys ; 25(4): e14192, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37962032

RESUMEN

OBJECTIVE: This study assesses the robustness of first-order radiomic texture features namely interquartile range (IQR), coefficient of variation (CV) and standard deviation (SD) derived from computed tomography (CT) images by varying dose, reconstruction algorithms and slice thickness using scans of a uniform water phantom, a commercial anthropomorphic liver phantom, and a human liver in-vivo. MATERIALS AND METHODS: Scans were acquired on a 16 cm detector GE Revolution Apex Edition CT scanner with variations across three different nominal slice thicknesses: 0.625, 1.25, and 2.5 mm, three different dose levels: CTDIvol of 13.86 mGy for the standard dose, 40% reduced dose and 60% reduced dose and two different reconstruction algorithms: a deep learning image reconstruction (DLIR-high) algorithm and a hybrid iterative reconstruction (IR) algorithm ASiR-V50% (AV50) were explored, varying one at a time. To assess the effect of non-linear modifications of images by AV50 and DLIR-high, images of the water phantom were also reconstructed using filtered back projection (FBP). Quantitative measures of IQR, CV and SD were extracted from twelve pre-selected, circular (1 cm diameter) regions of interest (ROIs) capturing different texture patterns across all scans. RESULTS: Across all scans, imaging, and reconstruction settings, CV, IQR and SD were observed to increase with reduction in dose and slice thickness. An exception to this observation was found when using FBP reconstruction. Lower values of CV, IQR and SD were observed in DLIR-high reconstructions compared to AV50 and FBP. The Poisson statistics were more stringently noted in FBP than DLIR-high and AV50, due to the non-linear nature of the latter two algorithms. CONCLUSION: Variation in image noise due to dose reduction algorithms, tube current, and slice thickness show a consistent trend across phantom and patient scans. Prospective evaluation across multiple centers, scanners and imaging protocols is needed for establishing quality assurance standards of radiomics.


Asunto(s)
Algoritmos , Tomografía Computarizada por Rayos X , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Agua , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos
7.
Strahlenther Onkol ; 200(1): 19-27, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37429949

RESUMEN

PURPOSE: To analyze tumor characteristics derived from pelvic magnetic resonance imaging (MRI) of patients with squamous cell carcinoma of the anus (SCCA) before and during chemoradiotherapy (CRT), and to compare the changes in these characteristics between scans of responders vs. nonresponders to CRT. METHODS: We included 52 patients with a pelvic 3T MRI scan prior to CRT (baseline scan); 39 of these patients received an additional scan during week 2 of CRT (second scan). Volume, diameter, extramural tumor depth (EMTD), and external anal sphincter infiltration (EASI) of the tumor were assessed. Mean, kurtosis, skewness, standard deviation (SD), and entropy values were extracted from apparent diffusion coefficient (ADC) histograms. The main outcome was locoregional treatment failure. Correlations were evaluated with Wilcoxon's signed rank-sum test and Pearson's correlation coefficient, quantile regression, univariate logistic regression, and area under the ROC curve (AUC) analyses. RESULTS: In isolated analyses of the baseline and second MRI scans, none of the characteristics were associated with outcome. Comparison between the scans showed significant changes in several characteristics: volume, diameter, EMTD, and ADC skewness decreased in the second scan, although the mean ADC increased. Small decreases in volume and diameter were associated with treatment failure, and these variables had the highest AUC values (0.73 and 0.76, respectively) among the analyzed characteristics. CONCLUSION: Changes in tumor volume and diameter in an early scan during CRT could represent easily assessable imaging-based biomarkers to eliminate the need for analysis of more complex MRI characteristics.


Asunto(s)
Neoplasias del Ano , Neoplasias del Recto , Humanos , Neoplasias del Recto/patología , Imagen por Resonancia Magnética/métodos , Resultado del Tratamiento , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias del Ano/diagnóstico por imagen , Neoplasias del Ano/terapia , Quimioradioterapia/métodos , Estudios Retrospectivos
8.
Acta Orthop ; 94: 550-544, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37909103

RESUMEN

BACKGROUND AND PURPOSE: Radiostereometric analysis (RSA) is the gold standard for evaluation of migration of implants. CT-RSA has been shown to have precision at the level of RSA in hip, shoulder, and knee joint replacements. We aimed to assess the impact of dose reduction on precision of CT-RSA on tibial implants, comparing it with previously published data on precision of standard dose CT-RSA on tibial implants. MATERIAL AND METHODS: We performed a total knee arthroplasty on a porcine knee cadaver, and subsequent CT-RSA with low effective doses (0.02 mSv). We compared the results with previously published CT-RSA data with standard (0.08 mSv) dose. The primary outcome variable was the difference in precision of the maximum total translation (MTT). Secondary variables included ratios of variances and standard deviations, and precision of peripheral point translations, center-of-mass translations, and rotations. A difference of more than 0.1 mm in precision was defined as clinically relevant. Our hypothesis was that precisions of low and standard CT-RSA doses were equal. RESULTS: Low dose (mean 0.07, 95% confidence interval [CI] 0.06-0.08) and standard dose CT-RSA (0.08, CI 0.07-0.09) achieve similar precision, with difference in precision of MTT of 0.01, CI 0.00-0.02 mm. The F-statistic (0.99, CI 0.63-1.55) and sdtest (1.05, CI 0.43-2.58) also supported this. CONCLUSION: We conclude that the precision of low dose CT-RSA for tibial implants on a porcine cadaver is equal to standard dose CT-RSA. However, these findings should be confirmed in clinical trials.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Análisis Radioestereométrico , Porcinos , Animales , Análisis Radioestereométrico/métodos , Reducción Gradual de Medicamentos , Tomografía Computarizada por Rayos X/métodos , Cadáver
9.
Surg Endosc ; 37(12): 9283-9290, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37880446

RESUMEN

BACKGROUND AND AIMS: The functional luminal imaging probe (FLIP) can provide measurements of lower esophageal sphincter (LES) distensibility. Studies report that use of intraoperative FLIP examination during peroral endoscopic myotomy (POEM) for achalasia is associated with treatment success, but evidence is limited and inconsistent. The main aim of the present study was to assess associations between intraoperative FLIP values and 1-year outcomes. Additionally, associations between 1-year FLIP measurements and other 1-year outcome variables were studied. METHODS: We performed a single-center prospective study of consecutive achalasia patients treated with POEM with a standardized 1-year follow-up. The inclusion period was from June 2017 to January 2020. We compared 1-year outcomes (FLIP measurement values, Eckardt score (ES), reflux esophagitis, timed barium esophagogram (TBE), and lower esophageal sphincter resting pressure (LES-rp)) in patients with and without intraoperative FLIP examination. We also assessed associations between intraoperative FLIP values, 1-year FLIP values, and other 1-year outcomes. Results are given as median (IQR), and non-parametrical statistical analyses were applied. RESULTS: Sixty-two patients (27 females) with median age 45 years (35-54) were included. Baseline characteristics were similar in patients with (n = 32) and without (n = 30) intraoperative FLIP examination. In patients with intraoperative FLIP, ES was 2 (1-3) and LES distensibility index (DI) 3.7 (2.6-5.4) after 1 year, compared with ES 2 (1-3) and DI 4.0 (3.1-6.8)) in patients without intraoperative FLIP (ns). Intraoperative DI was not correlated with 1-year ES or DI. One-year DI correlated significantly with 1-year ES (rs - 0.42), TBE (rs - 0.34), and LES-rp (rs - 0.29). CONCLUSIONS: Use of intraoperative FLIP measurements in POEM for achalasia is not associated with improved 1-year outcome, and the clinical value of intraoperative FLIP in POEM for achalasia is questioned. Follow-up FLIP measurements are moderately associated with symptomatic outcome, and may serve as an additional diagnostic modality in post-treatment evaluation.


Asunto(s)
Acalasia del Esófago , Cirugía Endoscópica por Orificios Naturales , Femenino , Humanos , Persona de Mediana Edad , Acalasia del Esófago/diagnóstico , Estudios de Seguimiento , Estudios Prospectivos , Cirugía Endoscópica por Orificios Naturales/métodos , Esfínter Esofágico Inferior/cirugía , Resultado del Tratamiento , Esofagoscopía/métodos
10.
J Exp Orthop ; 10(1): 83, 2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37584812

RESUMEN

PURPOSE: Ligament balancing is a prerequisite for good function and survival in total knee arthroplasty (TKA). Various balancing techniques exist, but none have shown superior results. The pie-crusting technique by Bellemans of the medial collateral ligament is commonly utilized; however, it can be difficult to achieve repeatable ligament lengthening with this technique. Therefore, we invented a novel instrument to standardize the pie-crusting technique of the superficial and deep medial collateral ligament (hereafter MCL). The purpose was to examine if pie-crusting with the instrument could produce repeatable ligament lengthening. METHODS: The MCL was isolated in 16 human cadaveric knees, and subjected to axial tension. The instrument was composed of a specific grid of holes in rows, used to guide sequential pie-crusting puncturing of the MCL with a Ø1.6 mm end-cutting cannula. Ligament lengthening was measured after each row of punctures. Regression analysis was performed on the results. RESULTS: Mean lengthening ± SD in human cadaveric MCL for puncturing of row 1 in the instrument was 0.06 ± 0.09 mm, 0.06 ± 0.04 mm for row 2, 0.09 ± 0.08 mm for row 3, 0.06 ± 0.05 mm for row 4 and 0.06 ± 0.04 mm for row 5, giving a mean total lengthening of 0.33 ± 0.20 mm. Linear regression revealed that MCLs were repeatably lengthened by 0.07 mm per row when punctured using the instrument. CONCLUSIONS: MCLs showed linear lengthening in human cadavers for subsequent use of the instrument. Our instrument shows promising results for repeatable ligament lengthening.

11.
Acta Orthop ; 94: 207-214, 2023 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-37114404

RESUMEN

BACKGROUND AND PURPOSE: Radiostereometric analysis (RSA) is the gold standard for migration analysis, but computed tomography analysis methods (CTRSA) have shown comparable results in other joints. We attempted to validate precision for CT compared with RSA for a tibial implant. MATERIAL AND METHODS: RSA and CT were performed on a porcine knee with a tibial implant. Marker-based RSA, model-based RSA (MBRSA), and CT scans from 2 different manufacturers were compared. CT analysis was performed by 2 raters for reliability evaluation. RESULTS: 21 double examinations for precision measurements for RSA and CT-based Micromotion Analysis (CTMA) were analysed. Mean (95% confidence interval) precision data for maximum total point motion (MTPM) using marker-based RSA was 0.45 (0.19-0.70) and 0.58 (0.20-0.96) using MBRSA (F-statistic 0.44 [95% CI 0.18-1.1], p = 0.07). Precision data for total translation (TT) for CTMA was 0.08 (0.03-0.12) for the GE scanner and 0.11 (0.04-0.19) for the Siemens scanner (F-statistic 0.37 [0.15-0.91], p = 0.03). When comparing the aforementioned precision for both RSA methods with both CTMA analyses, CTMA was more precise (p < 0.001). The same pattern was seen for other translations and migrations. Mean effective radiation doses were 0.005 mSv (RSA) (0.0048-0.0050) and 0.08 mSv (CT) (0.078-0.080) (p < 0.001). Intra- and interrater reliability were 0.79 (0.75-0.82) and 0.77 (0.72-0.82), respectively. CONCLUSION: CTMA is more precise than RSA for migration analysis of a tibial implant, has overall good intra- and interrater reliability but higher effective radiation doses in a porcine cadaver.


Asunto(s)
Prótesis de Cadera , Análisis Radioestereométrico , Porcinos , Animales , Análisis Radioestereométrico/métodos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Cadáver
12.
Res Diagn Interv Imaging ; 5: 100022, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-39076164

RESUMEN

Purpose: To assess image quality of a deep learning reconstruction (DLR) algorithm across dose levels using a semi-anthropomorphic upper-abdominal phantom, and compare with filtered back projection (FBP) and hybrid iterative reconstruction (IR). Material and methods: CT scans obtained at five dose levels (CTDIvol 5, 10, 15, 20 and 25 mGy) were reconstructed with FBP, hybrid IR (IR50, IR70 and IR90) and DLR of low (DLL), medium (DLM) and high strength (DLH) in 0.625 mm and 2.5 mm slices. CT number, homogeneity, noise, contrast, contrast-to-noise ratio (CNR), noise texture deviation (NTD; a measure of IR-specific artifacts), noise power spectrum (NPS) and task-based transfer function (TTF) were compared between reconstruction algorithms. Results: CT numbers were highly consistent across reconstruction algorithms. Image noise was significantly reduced with higher levels of DLR. Noise texture (NPS and NTD) was with DLR maintained at comparable levels to FBP, contrary to increasing levels of hybrid IR. Images reconstructed with DLR of low and high strength in 0.625 mm slices showed similar noise characteristics to 2.5 mm slice FBP and IR50, respectively. Dose-reduction potential based on image noise with IR50 as reference was estimated to 35% for DLM and 74% for DLH. Conclusions: The novel DLR algorithm demonstrates robust noise reduction with maintained noise texture characteristics despite higher algorithm strength, and may have overcome important limitations of IR. There may be potential for dose reduction and additional benefit from thin-slice reconstruction.

13.
Eur J Radiol Open ; 9: 100418, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35391822

RESUMEN

Background: A novel deep learning image reconstruction (DLIR) algorithm for CT has recently been clinically approved. Purpose: To assess low-contrast detectability and dose reduction potential for CT images reconstructed with the DLIR algorithm and compare with filtered back projection (FBP) and hybrid iterative reconstruction (IR). Material and methods: A customized upper-abdomen phantom containing four cylindrical liver inserts with low-contrast lesions was scanned at CT dose indexes of 5, 10, 15, 20 and 25 mGy. Images were reconstructed with FBP, 50% hybrid IR (IR50), and DLIR of low strength (DLL), medium strength (DLM) and high strength (DLH). Detectability was assessed by 20 independent readers using a two-alternative forced choice approach. Dose reduction potential was estimated separately for each strength of DLIR using a fitted model, with the detectability performance of FBP and IR50 as reference. Results: For the investigated dose levels of 5 and 10 mGy, DLM improved detectability compared to FBP by 5.8 and 6.9 percentage points (p.p.), and DLH improved detectability by 9.6 and 12.3 p.p., respectively (all p < .007). With IR50 as reference, DLH improved detectability by 5.2 and 9.8 p.p. for the 5 and 10 mGy dose level, respectively (p < .03). With respect to this low-contrast detectability task, average dose reduction potential relative to FBP was estimated to 39% for DLM and 55% for DLH. Relative to IR50, average dose reduction potential was estimated to 21% for DLM and 42% for DLH. Conclusions: Low-contrast detectability performance is improved when applying a DLIR algorithm, with potential for radiation dose reduction.

14.
HPB (Oxford) ; 24(7): 1055-1062, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34924292

RESUMEN

BACKGROUND: Many patients undergoing resection for colorectal liver metastases (CRLM) recur with poor survival. Overall survival (OS) following liver transplantation (LT) for CRLM is reported to be about 80% at 5 years. In this study, survival following resection versus transplantation for CRLM in patients with moderate (6-70 cm3) metabolic tumor volume (MTV) from the preoperative positron emission tomography (PET) was compared. METHODS: Disease-free survival (DFS), OS and post recurrence survival (PRS) following resection (n = 18) and LT (n = 12) was compared by using the Kaplan Meier method and log rank test for patients with moderate MTV. RESULTS: Patients undergoing LT had unresectable metastases, significantly lower age, higher tumor burden score and number of liver metastases, longer time from diagnosis to surgery, and more patients received neoadjuvant chemotherapy. OS at 5 years was 39% in the resection group and 83% in the LT group (P = 0.012). PRS was significantly improved in patients treated with LT compared to resection with 71% alive at 5 years from recurrence compared to 17% in the resection group (P = 0.017). CONCLUSION: LT for selected patients seems to be superior to resection as treatment for CRLM for patients with moderate MTV.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Trasplante de Hígado , Neoplasias Colorrectales/patología , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Trasplante de Hígado/efectos adversos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Estudios Retrospectivos , Carga Tumoral
15.
Acta Radiol Open ; 10(10): 20584601211055389, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34840815

RESUMEN

BACKGROUND: Radiation-related cancer risk is an object of concern in CT of trauma patients, as these represent a young population. Different radiation reducing methods, including iterative reconstruction (IR), and spilt bolus techniques have been introduced in the recent years in different large scale trauma centers. PURPOSE: To compare image quality in human cadaver exposed to thoracoabdominal computed tomography using IR and standard filtered back-projection (FBP) at different dose levels. MATERIAL AND METHODS: Ten cadavers were scanned at full dose and a dose reduction in CTDIvol of 5 mGy (low dose 1) and 7.5 mGy (low dose 2) on a Siemens Definition Flash 128-slice computed tomography scanner. Low dose images were reconstructed with FBP and Sinogram affirmed iterative reconstruction (SAFIRE) level 2 and 4. Quantitative image quality was analyzed by comparison of contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). Qualitative image quality was evaluated by use of visual grading regression (VGR) by four radiologists. RESULTS: Readers preferred SAFIRE reconstructed images over FBP at a dose reduction of 40% (low dose 1) and 56% (low dose 2), with significant difference in overall impression of image quality. CNR and SNR showed significant improvement for images reconstructed with SAFIRE 2 and 4 compared to FBP at both low dose levels. CONCLUSIONS: Iterative image reconstruction, SAFIRE 2 and 4, resulted in equal or improved image quality at a dose reduction of up to 56% compared to full dose FBP and may be used a strong radiation reduction tool in the young trauma population.

16.
Ann Med ; 53(1): 2225-2233, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34806501

RESUMEN

BACKGROUND AND AIMS: Peroral endoscopic myotomy (POEM) is an established therapy for achalasia, but outcome evaluation has often been limited to Eckardt score (ES). The present study was aimed to improve knowledge about outcome evaluation and predictive outcome factors by performing a comprehensive objective evaluation of achalasia patients treated by POEM. METHODS: This single centre prospective study reports outcome data 12 months after POEM in treatment-naive achalasia patients. A predefined follow-up protocol included ES, high resolution manometry, 24-h pH measurement, upper endoscopy and timed barium esophagogram (TBE). Univariate and multivariate regression analyses were performed to analyze association between post-POEM variables and identify predictive factors for objective outcome. RESULTS: Fifty patients were included with a drop-out rate of <5%. ES, lower oesophageal sphincter pressures, TBE heights and maximal oesophageal diameter were all reduced after POEM (p < .001), and 28% (13/47) of the patients had a positive 24-h pH registration. An oesophageal diameter >3 cm after POEM was associated with treatment failure assessed by ES (p = .04) and TBE (p = .03). Advanced achalasia stage (p = .02) and long symptom duration (p = .04) were identified as independent predictive factors for poor outcome assessed by TBE. CONCLUSIONS: The present study confirms that POEM is an efficient therapy for achalasia. The comprehensive objective evaluation after POEM demonstrates that long symptom duration and major changes in oesophageal anatomy at diagnosis imply poor treatment outcome, and a post-POEM dilated oesophagus is associated with treatment failure.Key messagesPeroral endoscopic myotomy (POEM) is established as a safe and effective therapy for achalasia.Timed barium esophagogram offers objective variables that are valuable in treatment response evaluation. Advanced achalasia stage and long symptom duration are predictive factors for poor objective treatment response after POEM.


Asunto(s)
Acalasia del Esófago/cirugía , Esfínter Esofágico Inferior/cirugía , Esofagoscopía/métodos , Miotomía/métodos , Cirugía Endoscópica por Orificios Naturales/métodos , Adulto , Anciano , Bario , Acalasia del Esófago/diagnóstico por imagen , Esfínter Esofágico Inferior/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Cirugía Endoscópica por Orificios Naturales/efectos adversos , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
17.
Acta Radiol Open ; 10(4): 20584601211008391, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33889427

RESUMEN

BACKGROUND: A novel Deep Learning Image Reconstruction (DLIR) technique for computed tomography has recently received clinical approval. PURPOSE: To assess image quality in abdominal computed tomography reconstructed with DLIR, and compare with standardly applied iterative reconstruction. MATERIAL AND METHODS: Ten abdominal computed tomography scans were reconstructed with iterative reconstruction and DLIR of medium and high strength, with 0.625 mm and 2.5 mm slice thickness. Image quality was assessed using eight visual grading criteria in a side-by-side comparative setting. All series were presented twice to evaluate intraobserver agreement. Reader scores were compared using univariate logistic regression. Image noise and contrast-to-noise ratio were calculated for quantitative analyses. RESULTS: For 2.5 mm slice thickness, DLIR images were more frequently perceived as equal or better than iterative reconstruction across all visual grading criteria (for both DLIR of medium and high strength, p < 0.001). Correspondingly, DLIR images were more frequently perceived as better (as opposed to equal or in favor of iterative reconstruction) for visual reproduction of liver parenchyma, intrahepatic vascular structures as well as overall impression of image noise and texture (p < 0.001). This improved image quality was also observed for 0.625 mm slice images reconstructed with DLIR of high strength when directly comparing to traditional iterative reconstruction in 2.5 mm slices. Image noise was significantly lower and contrast-to-noise ratio measurements significantly higher for images reconstructed with DLIR compared to iterative reconstruction (p < 0.01). CONCLUSIONS: Abdominal computed tomography images reconstructed using a DLIR technique shows improved image quality when compared to standardly applied iterative reconstruction across a variety of clinical image quality criteria.

18.
Eur J Radiol Open ; 8: 100341, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33898653

RESUMEN

BACKGROUND: Following an episode of acute diverticulitis, surgical guidelines commonly advise routine colonic follow-up to rule out underlying malignancy. However, as a CT of the abdomen is frequently performed during clinical work-up, the routine need for colonic follow-up has become debated. PURPOSE: To evaluate the need for routine CT colonography after an episode of CT-verified uncomplicated sigmoid diverticulitis to rule out underlying colorectal malignancy. MATERIAL AND METHODS: This study retrospectively evaluated 312 patients routinely referred to colonic evaluation by CT colonography following an episode of acute diverticulitis. Patients were excluded if lacking diagnostic CT of the abdomen at time of diagnosis, if presenting with atypical colonic involvement, or if CT findings were suggestive of complicated disease (e.g., abscess or perforation). CT colonography exams were routinely reviewed by experienced abdominal radiology consultants on the day of the procedure. If significant polyps were detected, or if colorectal malignancy could not be excluded, patients were referred to same-day optical colonoscopy. For these patients, medical records were reviewed for optical colonoscopy results and histology reports if applicable. RESULTS: Among 223 patients with CT-verified uncomplicated sigmoid diverticulitis, no patients were found to have underlying colorectal malignancy. 27 patients were referred to optical colonoscopy based on CT colonography findings. 18 patients consequently underwent polypectomy, all with either hyperplastic or adenomatous histology. CONCLUSIONS: This study indicates that routine colonic evaluation by CT colonography following an episode of CT-verified uncomplicated sigmoid diverticulitis may be unwarranted, and should arguably be reserved for patients with protracted or atypical clinical course.

19.
Emerg Radiol ; 28(1): 37-46, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32686046

RESUMEN

PURPOSE: To evaluate whether an arterial phase scan improves the diagnostic performance of computed tomography to identify pelvic trauma patients who received angiographic intervention on demand of the trauma surgeon. METHODS: This retrospective single-center study was performed at an academic Scandinavian trauma center with approximately 2000 trauma admissions annually. Pelvic trauma patients with arterial and portal venous phase CT from 2009 to 2015 were included. The patients were identified from the institutional trauma registry. Images were interpreted by two radiologists with more than 10 years of trauma radiology experience. Positive findings for extravasation on portal venous phase alone or on both arterial and portal venous phase were compared, with angiographic intervention as clinical outcome. RESULTS: One hundred fifty-seven patients (54 females, 103 males) with a median age of 45 years were enrolled. Sixteen patients received angiographic intervention. Positive CT findings on portal venous phase only had a sensitivity and specificity of 62% and 86%, vs. 56% and 93% for simultaneous findings on arterial and portal venous phase. Specificity was significantly higher for positive findings in both phases compared with portal venous phase only. Applying a threshold > 0.9 cm of extravasation diameter to portal venous phase only resulted in sensitivity and specificity identical to those of both phases. CONCLUSION: Arterial phase scan in addition to portal venous phase scan did not improve patient selection for angiography. Portal venous phase extravasation size alone may be used as an imaging-based biomarker of the need for angiographic intervention.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Huesos Pélvicos/lesiones , Heridas no Penetrantes/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Puntaje de Gravedad del Traumatismo , Yopamidol/análogos & derivados , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Sensibilidad y Especificidad , Centros Traumatológicos
20.
Nucl Med Commun ; 41(9): 916-923, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32796480

RESUMEN

OBJECTIVE: The liver is the most frequent metastatic site from colorectal cancer and about 20% of these patients are treated by surgical resection. However, the 5-year disease-free survival (DFS) following resection is only about 25% and 5-year overall survival (OS) about 38%. The aim of the study was to evaluate the ability of metabolic and volumetric measurements from fluorine-18-fluorodeoxyglucose (F-FDG) PET/computed tomography (CT) prior to resection for colorectal liver metastases (CLM) to predict survival. PATIENTS AND METHODS: Preoperative F-FDG PET/CT examinations were assessed. Metabolic tumor volume (MTV), total lesion glycolysis (TLG), maximum, mean and peak standardized uptake values and tumor to background ratio, were obtained for all CLM. Cutoff values were determined for each of these parameters by using receiver operating characteristic analysis dividing the patients into two groups. DFS, liver recurrence-free survival (LRFS), OS and cancer-specific survival (CSS) for patients over and under the cutoff value were compared by using the Kaplan-Meier method and log-rank test. RESULTS: Twenty-seven patients who underwent F-FDG PET/CT prior to resection for CLM were included. Low values of total MTV and TLG were significantly correlated to improved 5-year LRFS (P = 0.016 and 0.006) and CSS (P = 0.034 and 0.008). Patients who developed liver recurrence had significantly higher total MTV and TLG compared to patients without liver recurrence (P = 0.042 and 0.047). CONCLUSION: Low values of total MTV and TLG were significantly correlated to improved LRFS and CSS and may improve the risk stratification of patients considered for resection for CLM.


Asunto(s)
Neoplasias Colorrectales/patología , Fluorodesoxiglucosa F18 , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Tomografía Computarizada por Tomografía de Emisión de Positrones , Periodo Preoperatorio , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Estimación de Kaplan-Meier , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos