Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Plast Reconstr Surg Glob Open ; 12(9): e6119, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39247578

RESUMEN

Background: With neck, aging the cervicomental angle becomes obtuse and may be influenced by hyoid bone aging. An understanding of hyoid position changes with aging will further our understanding of its role in neck contour changes. Methods: A 3D volumetric reconstruction of 282 neck computed tomography scans was performed. The cohort was categorized into three groups based on age: 20 years or older and younger than 40 years, 40 years or older and younger than 60 years, and 60 years or older and younger than 80 years. The vertical and horizontal hyoid distances in relation to the mandible were calculated for each patient. Results: A total of 282 patients (153 women, 129 men) were included in the cohort. The age groups were evenly distributed in men and women. Mean hyoid vertical and horizontal distances differed between women and men in all age groups. There was a significant difference in the hyoid vertical distance between 20-39 years old to 40-59 years old in men (P < 0.01), and 20-39 years old to 60-79 years old in both genders (women P = 0.005, men P < 0.01). Hyoid horizontal distance was not affected by age and sex (age and sex: P > 0.05), but rather by body mass index (BMI). Every 5 BMI points corresponded to a forward movement of 2 mm. Conclusions: As individuals age, the hyoid bone descends in both sexes, and an increase in BMI is associated with forward movement. Additional studies are needed to assess the correlation of the hyoid position between upright and supine positions.

2.
Aesthetic Plast Surg ; 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39187587

RESUMEN

BACKGROUND: In gender-affirming surgery, facial skeletal dimorphism is an important topic for every craniofacial surgeon. Few cephalometric studies have assessed this topic; however, they fall short to provide skeletal contour insights that direct surgical planning. Herein, we propose statistical shape modeling (SSM) as a novel tool for investigating mandibular dimorphism for young white individuals. METHODS: A single-center, retrospective study was performed using computed tomography (CT) scans of white individuals, aged 20 to 39 years old. AI-assisted, three-dimensional (3D) mandibles were reconstructed in Materialise Mimics v25.0. We used SSM to generate average 3D models for both genders. Relevant manual anthropometric measurements were taken for the SSMs and individual mandibles. Contour disparities were then represented using 3D overlays and heatmaps. Statistical analyses were performed using unpaired student t testing or Wilcoxon signed rank testing with 95% confidence interval as deemed appropriate by population-level normality assessment. RESULTS: Ninety-eight patients (53 females, 45 males) were included. Male mandibles showed greater bigonial width, intercondylar width, ramus height, and body length [p<0.005]. There was no statistically significant difference in the gonial angle measurements [p=0.62]. All relevant manual individual measurements demonstrated excellent concordance to their SSM counterparts. The 3D overlays of SSMs revealed squarer male chins with more lateral but less anterior projection than their female counterparts. Also, the female mandibles showed smoother transition at the gonial angle. CONCLUSIONS: SSM provides a novel tool to objectively evaluate volumetric and contour dimorphisms between genders. Moreover, this method can be automated, allowing for expedited comparisons between populations of interest compared to manual assessment. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors   www.springer.com/00266 . Bullet points about the importance of this work: Advancing Anthropometric Assessment: Statistical shape modeling (SSM) offers a cutting-edge approach to visualizing gender-specific skeletal anatomic differences for aesthetic and gender-affirming facial surgery. Expediting Comparative Analysis: The workflow established in this paper streamlines the evaluative process, enabling rapid morphologic comparisons between populations. Patient-Centered Care: This study establishes a foundation for the development of SSMs in individualized operative planning.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38981580

RESUMEN

BACKGROUND: Virtual surgical planning (VSP) for composite microvascular free flaps has become standard of care for oncologic head and neck reconstruction. Controversy remains as to the use of three-dimensional (3D)-printed patient-specific titanium implants (PSIs) versus hand-bent stock reconstruction plates. Proponents of PSIs cite improved surgical accuracy, reduced operative times, and improved clinical outcomes. Detractors purport increased cost associated with PSIs and presumed equivalent accuracy with less expensive stock plates. PURPOSE: The study purpose was to measure and compare the 3D-volumetric accuracy of PSI versus stock reconstruction plates among subjects undergoing VSP-guided mandibular fibular free flap reconstruction. STUDY DESIGN, SETTING, SAMPLE: A retrospective cohort study of subjects undergoing VSP-guided fibular free flap reconstructions at Mayo Clinic between 2016 and 2023 was performed. Subjects were excluded for non-VSP guidance, midfacial reconstruction, nonfibular free flaps, and lack of requisite study variables. PREDICTOR VARIABLE: The primary predictor was the type of reconstruction plate utilized (PSI vs stock plate). MAIN OUTCOME VARIABLE: The main outcome was volumetric surgical accuracy of the final reconstruction compared to the preoperative surgical plan by root mean square error (RMSE) calculation. Lower RMSE values indicated a higher surgical accuracy. COVARIATES: Covariates included age, sex, race, smoking status, American Society of Anesthesiologists (ASA) Physical Status Classification System, Charlson Comorbidity Index, preoperative diagnosis, and number of fibular segments. ANALYSES: Differences in surgical accuracy were assessed between preoperative and postoperative segmented scans using volumetric overlays from which RMSE values were calculated. Univariate and multivariate modeling of plate type to RMSE calculation was performed. Statistical significance set to P < .05. RESULTS: Total of 130 subjects were identified, 105 PSI and 25 stock plates. Calculated mean RMSE in millimeters (mm) for stock plates was 1.46 (standard deviation: 0.33) and 1.15 (standard deviation: 0.36) for PSIs. Univariate modeling demonstrated a statistically significant difference in RMSE of 0.31 (95% confidence interval: 0.16-0.47) (P < .001) equating to a 21.2% (P < .001) improved volumetric surgical accuracy for PSIs. The association of improved volumetric accuracy with PSIs has been maintained in all multivariate models controlling for confounding. CONCLUSION AND RELEVANCE: In modern era VSP-guided head and neck fibular free flap reconstruction, patient-specific 3D-printed titanium implants confer a statistically significant improvement in volumetric surgical accuracy over stock reconstruction plates.

4.
J Med Imaging (Bellingham) ; 10(2): 026501, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37020530

RESUMEN

Purpose: Three-dimensional (3D) printing has had a significant impact on patient care. However, there is a lack of standardization in quality assurance (QA) to ensure printing accuracy and precision given multiple printing technologies, variability across vendors, and inter-printer reliability issues. We investigated printing accuracy on a diverse selection of 3D printers commonly used in the medical field. Approach: A specially designed 3D printing QA phantom was periodically printed on 16 printers used in our practice, covering five distinct printing technologies and eight different vendors. Longitudinal data were acquired over six months by printing the QA phantom monthly on each printer. Qualitative assessment and quantitative measurements were obtained for each printed phantom. Accuracy and precision were assessed by comparing quantitative measurements with reference values of the phantom. Data were then compared among printer models, vendors, and printing technologies; longitudinal trends were also analyzed. Results: Differences in 3D printing accuracy across printers were observed. Material jetting and vat photopolymerization printers were found to be the most accurate. Printers using the same 3D printing technology but from different vendors also showed differences in accuracy, most notably between vat photopolymerization printers from two different vendors. Furthermore, differences in accuracy were found between printers from the same vendor using the same printing technology, but different models/generations. Conclusions: These results show how factors such as printing technology, vendor, and printer model can impact 3D printing accuracy, which should be appropriately considered in practice to avoid potential medical or surgical errors.

5.
Cardiovasc Intervent Radiol ; 46(3): 385-391, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36482095

RESUMEN

PURPOSE: This study aims to define the process of designing and manufacturing 3D printed and glass models of the pulmonary artery (PA) and utilizing them in a test bed for evaluation of devices for mechanical thrombectomy of pulmonary embolism (PE). MATERIALS AND METHODS: Patient derived computed tomography angiography (CTA) images of the PA were digitally converted into a hollowed-out structure and translated into clear 3D printed and glass models. A test bed was created using a peristaltic pump and silicone tubing connected to the models. Human clot analogs were then prepared and injected within the models. Thrombectomy testing was done using clinically used predicates and baseline characteristics of the models were evaluated by independent interventionalists. RESULTS: The mean sizes of the main pulmonary artery (MPA) for the 3D printed model and glass model were 30.4 mm and 29.2 mm, mimicking those of the patient's PA obtained on CTA. Heterogeneous human clot analogs were created with fibrin composition ranging from 60 to 30%. Mechanical thrombectomy was successfully attempted by independent interventionalists. Both the 3D printed, and glass model were appraised as very good for multiple attributes. CONCLUSION: A complete test bed using 3D printed and glass models of the PA with human clot analogs was created for testing of mechanical thrombectomy devices for PE.


Asunto(s)
Embolia Pulmonar , Trombosis , Humanos , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/cirugía , Trombectomía/métodos , Arteria Pulmonar , Angiografía , Angiografía por Tomografía Computarizada
6.
Semin Plast Surg ; 36(3): 133-148, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36506280

RESUMEN

Virtual surgical planning (VSP) and three-dimensional (3D) printing have become a standard of care at our institution, transforming the surgical care of complex patients. Patient-specific, anatomic models and surgical guides are clinically used to improve multidisciplinary communication, presurgical planning, intraoperative guidance, and the patient informed consent. Recent innovations have allowed both VSP and 3D printing to become more accessible to various sized hospital systems. Insourcing such work has several advantages including quicker turnaround times and increased innovation through collaborative multidisciplinary teams. Centralizing 3D printing programs at the point-of-care provides a greater cost-efficient investment for institutions. The following article will detail capital equipment needs, institutional structure, operational personnel, and other considerations necessary in the establishment of a POC manufacturing program.

7.
Mater Today Commun ; 272021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33937466

RESUMEN

Disruption of the reparative process, often found in diabetic patients, results in chronic, non-healing wounds that significantly impact a patient's quality of life. This highlights the need of new therapeutic options to improve the healing of diabetic wounds. In this study, we focused on developing a cell-free hydrogel dressing loaded with mesenchymal stem cell (MSC)-conditioned media (CM) to potentially improve the healing of hard-to-heal wounds. We simulated a hyperglycemic environment by incubating human dermal fibroblasts in a high glucose environment (30 mM) and validated that MSC-CM rescued the impaired functions (proliferation and migration) of hyperglycemic fibroblasts. Further, we investigated the effect of loading MSC-CM in gelatin methacrylate (GelMA)-poly (ethylene glycol) diacrylate (PEGDA) hybrid hydrogels in improving the proliferative activity of glucose-treated fibroblasts. The controlled release of bioactive factors from MSC-CM loaded GelMA-PEGDA hydrogels promoted the metabolic activity of hyperglycemic fibroblasts. In addition, the growth rate of hyperglycemic fibroblasts was found to be similar to that of normal fibroblasts. Our observations, thus, suggest the potential application of cell-free, MSC-secretome-loaded hydrogel in the healing of diabetic or chronic wounds.

8.
Biotechnol Bioeng ; 117(4): 1159-1171, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31956977

RESUMEN

The low engraftment and retention rate of mesenchymal stem cells (MSCs) at the target site indicates that the potential benefits of MSC-based therapies can be attributed to their paracrine signaling. In this study, the extracellular matrices (ECMs) deposited by bone marrow-derived human MSCs in the presence and absence of ascorbic acid was characterized. MSCs were seeded on top of decellularized ECM (dECM) and the concentrations of proangiogenic and antiangiogenic molecules released in culture (conditioned) media was compared. Effects of ECM derived from MSCs with different passage numbers on MSC secretome was also investigated. Our study revealed that the expression of proangiogenesis-related factors were upregulated when MSCs were harvested on dECMs, irrespective of media supplementation, as compared with those cultured on tissue culture plates. In addition, dECM generated in the presence of ascorbic acid promoted the expression of proangiogenic molecules as compared with dECM-derived in absence of media supplementation. Further, it was observed that the effectiveness of dECM to stimulate proangiogenic signaling of MSCs was reduced as cell passage number was increased from P3 to P5. The proliferation as well as capillary morphogenesis of human umbilical vein endothelial cells (HUVECs) in the presence of conditioned media were enhanced compared with the normal HUVECs culture media. These data indicate that the secretory signatures of MSCs and consequently, the therapeutic efficacy of MSCs can be regulated by presentation of dECM composition and variation of its composition.


Asunto(s)
Matriz Extracelular/metabolismo , Células Madre Mesenquimatosas/metabolismo , Neovascularización Fisiológica/fisiología , Proteínas Angiogénicas/metabolismo , Proliferación Celular , Células Cultivadas , Medios de Cultivo Condicionados , Humanos , Células Madre Mesenquimatosas/citología , Comunicación Paracrina , Transducción de Señal/fisiología
9.
Biometals ; 29(1): 131-46, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26715107

RESUMEN

Cadmium (Cd) is a nephrotoxic environmental pollutant that causes insidious injury to the proximal tubule that results in severe polyuria and proteinuria. Cystatin C is a low molecular weight protein that is being evaluated as a serum and urinary biomarker for various types of ischemic and nephrotoxic renal injury. The objective of the present study was to determine if cystatin C might be a useful early biomarker of Cd nephrotoxicity. Male Sprague-Dawley rats were given daily injections of Cd for up to 12 weeks. At 3, 6, 9 and 12 weeks, urine samples were analyzed for cystatin C, protein, creatinine, ß2 microglobulin and kidney injury molecule-1. The results showed that Cd caused a significant increase in the urinary excretion of cystatin C that occurred 3-4 weeks before the onset of polyuria and proteinuria. Serum levels of cystatin C were not altered by Cd. Immunolabeling studies showed that Cd caused the relocalization of cystatin C from the cytoplasm to the apical surface of the epithelial cells of the proximal tubule. The Cd-induced changes in cystatin C labelling paralleled those of the brush border transport protein, megalin, which has been implicated as a mediator of cystatin C uptake in the proximal tubule. These results indicate that Cd increases the urinary excretion of cystatin C, and they suggest that this effect may involve disruption of megalin-mediated uptake of cystatin C by epithelial cells of the proximal tubule.


Asunto(s)
Biomarcadores/orina , Cadmio/toxicidad , Cistatina C/orina , Túbulos Renales Proximales/metabolismo , Animales , Biomarcadores/sangre , Cadmio/administración & dosificación , Moléculas de Adhesión Celular/sangre , Creatinina/sangre , Cistatina C/sangre , Contaminantes Ambientales , Humanos , Túbulos Renales Proximales/lesiones , Túbulos Renales Proximales/patología , Masculino , Ratas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA