1.
Artículo en Inglés | MEDLINE | ID: mdl-38082704

RESUMEN

The present study aims to design and fabricate a system capable of generating heterogeneities on the epicardial surface of an isolated rabbit heart perfused in a Langendorff system. The system consists of thermoelectric modules that can be independently controlled by the developed hardware, thereby allowing for the generation of temperature gradients on the epicardial surface, resulting in conduction slowing akin to heterogeneities of pathological origin. A comprehensive analysis of the system's viability was performed through modeling and thermal simulation, and its practicality was validated through preliminary tests conducted at the experimental cardiac electrophysiology laboratory of the University of Valencia. The design process involved the use of Fusion 360 for 3D designs, MATLAB/Simulink for algorithms and block diagrams, LTSpice and Altium Designer for schematic captures and PCB design, and the integration of specialized equipment for animal experimentation. The objective of the study was to efficiently capture epicardial recordings under varying conditions.Clinical relevance- The proposed system aims to induce local epicardial heterogeneities to generate labeled correct signals that can serve as a golden standard for improving algorithms that identify and characterize fibrotic substrates. This improvement will enhance the efficacy of ablation processes and potentially reduce the ablated surface area.


Asunto(s)
Corazón , Animales , Conejos , Corazón/fisiología , Frecuencia Cardíaca/fisiología , Temperatura
2.
Comput Biol Med ; 154: 106604, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36709520

RESUMEN

OBJECTIVE: The aim of this study is to propose a method to reduce the sensitivity of the estimated omnipolar electrogram (oEGM) with respect to the angle of the propagation wavefront. METHODS: A novel configuration of cliques taking into account all four electrodes of a squared cell is proposed. To test this approach, simulations of HD grids of cardiac activations at different propagation angles, conduction velocities, interelectrode distance and electrogram waveforms are considered. RESULTS: The proposed approach successfully provided narrower loops (essentially a straight line) of the electrical field described by the bipole pair with respect to the conventional approach. Estimation of the direction of propagation was improved. Additionally, estimated oEGMs presented larger amplitude, and estimations of the local activation times were more accurate. CONCLUSIONS: A novel method to improve the estimation of oEGMs in HD grid of electrodes is proposed. This approach is superior to the existing methods and avoids pitfalls not yet resolved. RELEVANCE: Robust tools for quantifying the cardiac substrate are crucial to determine with accuracy target ablation sites during an electrophysiological procedure.


Asunto(s)
Electrocardiografía , Corazón , Electrocardiografía/métodos , Corazón/fisiología , Electrodos , Factores de Tiempo