1.
Phys Med ; 76: 72-76, 2020 Aug.
Article En | MEDLINE | ID: mdl-32599377

The transparent polymer polyallyl-diglycol-carbonate (PADC), also known as CR-39, is widely used as detector for heavy charged particles at low fluence. It allows for detection of single protons and ions via formation of microscopic tracks after etching in NaOH or KOH solutions. PADC combines a high sensitivity and high specificity with inertness towards electromagnetic noise. Present fields of application include laser-ion acceleration, inertial confinement fusion, radiobiological studies with cell cultures, and dosimetry of nuclear fragments in particle therapy. These require precise knowledge of the energy-dependent response of PADC to different ion species. We present calibration data for a new type of detector material, Radosys RS39, to protons (0.2-3 MeV) and carbon ions (0.6-12 MeV). RS39 is less sensitive to protons than other types of PADC. Its response to carbon ions, however, is similar to other materials. Our data indicate that RS39 allows for measuring carbon ion energies up to 10 MeV only from the track diameters. In addition, it can be used for discrimination between protons and carbon ions in a single etching process.


Polymers , Radiometry , Acceleration , Ions , Lasers , Spectrum Analysis
2.
Rev Sci Instrum ; 89(2): 023302, 2018 Feb.
Article En | MEDLINE | ID: mdl-29495831

CR-39 nuclear track material is frequently used for the detection of protons accelerated in laser-plasma interactions. The measurement of track densities allows for determination of particle angular distributions, and information on the kinetic energy can be obtained by the use of passive absorbers. We present a precise method of measuring spectral distributions of laser-accelerated protons in a single etching and analysis process. We make use of a one-to-one relation between proton energy and track size and present a precise calibration based on monoenergetic particle beams. While this relation is limited to proton energies below 1 MeV, we show that the range of spectral measurements can be significantly extended by simultaneous use of absorbers of suitable thicknesses. Examples from laser-plasma interactions are presented, and quantitative results on proton energies and particle numbers are compared to those obtained from a time-of-flight detector. The spectrum end points of continuous energy distributions have been determined with both detector types and coincide within 50-100 keV.

3.
Am J Physiol Lung Cell Mol Physiol ; 309(2): L119-28, 2015 Jul 15.
Article En | MEDLINE | ID: mdl-26001775

It has become more evident that long-term cigarette smoking (LTCS) has an important extrapulmonary toxicity. The aim of the study was to investigate the time-dependent effects of cigarette smoke exposure on exercise capacity, markers of systemic inflammation, and skeletal muscle structure. c57bl/6j-mice were either exposed to mainstream cigarette smoke for 6 h/day, 5 days/wk [smoke-exposed (SE) group] or assigned to the control, unexposed group (Con group). SE group mice were exposed for 8, 16, 24, and 32 wk to smoke and unexposed Con mice were used as age-matched controls. Exercise capacity was investigated by spiroergometry. Systemic inflammatory status was analyzed by flow cytometry and multiplexed fluorescent immunoassay. For analysis of muscle tissue, histological techniques and microarray analysis were used. Mice of the SE group exhibited a lower increase of body mass and a decrease of V̇o2 max (P < 0.05). An increase of lymphocyte CD62, ICAM, and VCAM expression was found in SE mice (P < 0.05). A biphasic trend of protein up- and downregulation was observed in markers of systemic inflammation, tissue deterioration, and allergic reactions such as C-reactive protein (CRP), eotaxin, haptoglobin, macrophage colony-stimulating factor-1 (M-CSF-1), and macrophage inflammatory protein-1γ (MIP-1γ). Thereby, the expression of several chemotactic proteins in plasma correlated with their expression in muscle. A time-dependent decrease of muscle mass, oxidative type-I fibers, and muscle cross-sectional area was found (P < 0.05). Microarray analysis revealed a SE-induced upregulation of several pathways of metabolic processes and tissue degradation. Taken together it was found that the loss of exercise capacity and systemic inflammation are early events of SE, which might induce muscular atrophy and loss of oxidative muscle capacity.


Biomarkers/metabolism , Inflammation/pathology , Muscle, Skeletal/pathology , Muscular Atrophy/chemically induced , Smoking/adverse effects , Animals , Body Mass Index , Cytokines/genetics , Cytokines/metabolism , Disease Models, Animal , Gene Expression Profiling , Inflammation/chemically induced , Inflammation/metabolism , Male , Mice , Mice, Inbred C57BL , Muscle, Skeletal/drug effects , Muscle, Skeletal/metabolism , Muscular Atrophy/metabolism , Muscular Atrophy/pathology , Oligonucleotide Array Sequence Analysis , Oxygen Consumption , Physical Conditioning, Animal , RNA, Messenger/genetics , Real-Time Polymerase Chain Reaction , Reverse Transcriptase Polymerase Chain Reaction , Time Factors
4.
Med Phys ; 39(9): 5393-404, 2012 Sep.
Article En | MEDLINE | ID: mdl-22957607

PURPOSE: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. METHODS: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. RESULTS: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV-750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. CONCLUSIONS: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.


Breast/diagnostic imaging , Positron-Emission Tomography/instrumentation , Equipment Design , Humans , Image Processing, Computer-Assisted
5.
Phys Rev Lett ; 103(15): 152501, 2009 Oct 09.
Article En | MEDLINE | ID: mdl-19905628

Cross sections for the 3He(e,e' pn)1H reaction were measured for the first time at energy transfers of 220 and 270 MeV for several momentum transfers ranging from 300 to 450 MeV/c. Cross sections are presented as a function of the momentum of the recoil proton and the momentum transfer. Continuum Faddeev calculations using the Argonne V18 and Bonn-B nucleon-nucleon potentials overestimate the measured cross sections by a factor 5 at low recoil proton momentum with the discrepancy becoming smaller at higher recoil proton momentum.

6.
Phys Rev Lett ; 88(14): 142001, 2002 Apr 08.
Article En | MEDLINE | ID: mdl-11955140

In a p((-->)e,e'p)pi(0) out-of-plane coincidence experiment at the three-spectrometer setup of the Mainz Microtron MAMI, the beam-helicity asymmetry has been precisely measured around the energy of the Delta(1232) resonance and Q(2) = 0.2(GeV/c)(2). The results are in disagreement with three up-to-date model calculations. This is interpreted as a lack of understanding of the nonresonant background, which in dynamical models is related to the pion cloud.

7.
Phys Rev Lett ; 88(1): 012301, 2002 Jan 07.
Article En | MEDLINE | ID: mdl-11800938

New data are presented on the p(e,e'p)pi(0) reaction at threshold at a four-momentum transfer of Q(2) = 0.05 GeV(2)/c(2). The data were taken with the three-spectrometer setup of the A1 Collaboration at the Mainz Microtron MAMI. The complete center of mass solid angle was covered up to a center of mass energy of 4 MeV above threshold. Combined with measurements at three different values of the virtual photon polarization epsilon, the structure functions sigma(T), sigma(L), sigma(TT), and sigma(TL) are determined. The results are compared with calculations in heavy baryon chiral perturbation theory and with a phenomenological model. The measured cross section is significantly smaller than both predictions.

8.
Phys Rev Lett ; 86(14): 2959-62, 2001 Apr 02.
Article En | MEDLINE | ID: mdl-11290082

The recoil proton polarization has been measured in the p(e-->,e'p-->)pi(0) reaction in parallel kinematics around W = 1232 MeV, Q2 = 0.121 (GeV/c)2, and epsilon = 0.718 using the polarized cw electron beam of the Mainz Microtron. All three proton polarization components, Px/P(e) = (-11.4+/-1.3+/-1.4)%, P(y) = (-43.1+/-1.3+/-2.2)%, and P(z)/P(e) = (56.2+/-1.5+/-2.6)%, could be measured simultaneously. The Coulomb quadrupole to magnetic dipole ratio, CMR = (-6.4+/-0.7(stat)+/-0.8(syst))%, was determined from Px in the framework of the Mainz Unitary Isobar Model. The consistency among the reduced polarizations and the extraction of the ratio of longitudinal-to-transverse response is discussed.

...