Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
4.
J Soc Cardiovasc Angiogr Interv ; 3(3Part B): 101293, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-39131219

RESUMEN

Background: Coronary artery disease (CAD) in patients with severe aortic stenosis (AS) is common and may be associated with worse outcomes. Computed tomography coronary angiography (CTCA) and fractional flow reserve derived from computed tomography (FFRCT) are tools for comprehensive coronary assessment. The utility and safety of CTCA and FFRCT in the work-up for transcatheter aortic valve replacement (TAVR) is not established, especially in an evolving landscape that involves younger TAVR patients. The FUTURE-AS Registry will assess the utility and safety of cardiac-optimized CTCA and FFRCT to evaluate CAD and guide referral for downstream invasive coronary angiography (ICA) in patients with severe AS being considered for TAVR. Methods: FUTURE-AS is an international, prospective, multicenter registry of patients with severe AS referred for TAVR being assessed for CAD with CTCA and FFRCT. The primary end point is the per-patient sensitivity and negative predictive value of CTCA and FFRCT for identifying anatomical and physiologically significant CAD compared to ICA and invasive FFR. The safety end point is the incidence of symptomatic hypotension or bradycardia requiring intervention following the administration of nitroglycerin or ß-blocker medications. Feasibility end points include the incidence of noninterpretable CTCA scans and CTCA scans not adequate for FFR analysis. Other utility end points include specificity, positive predictive value, and accuracy of CTCA and FFRCT. Lastly, the potential of a CTCA and FFRCT guided strategy to defer pre-TAVR ICA will be assessed. Conclusions: FUTURE-AS will characterize the utility, safety, and feasibility of CTCA and FFRCT for coronary assessment pre-TAVR.

5.
JACC Cardiovasc Interv ; 17(11): 1340-1351, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866457

RESUMEN

BACKGROUND: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms. OBJECTIVES: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology. METHODS: TAV explants were obtained from the EXPLANT THV registry and clinical institutions. Hydrodynamic assessment was performed using a heart valve pulse duplicator system under physiological conditions. Micro-computed tomography, high-resolution photography, high speed video, and hematoxylin and eosin staining were used to evaluate the morphological appearance, leaflet kinematics, and calcium burden of TAVs. RESULTS: A total of 14 explants were evaluated: 10 self-expanding CoreValve/Evolut TAVs (Medtronic), 3 balloon-expandable SAPIEN 3 TAVs (Edwards Lifesciences), and 1 mechanically expandable Lotus TAV (Boston Scientific). The median patient age at explantation was 73.0 years (Q1-Q3: 64.5-80.0 years), with a time to explantation of 4 years 1 month (1 year 5 months to 4 years 11 months). Six TAV explants were found to have leaflet calcification (162.4 mm3; 58.8-603.0 mm3), and 8 had no calcification detectable by micro-computed tomography and histology. All samples had impaired leaflet kinematics. There was no significant difference in the hydrodynamic mean gradient between calcified (47.2 mm Hg; 26.6-74.1 mm Hg) and noncalcified (27.6 mm Hg; 15.2-36.7 mm Hg; P = 0.28) TAVs. Leaflet calcification had a weak but nonsignificant association with the hydrodynamic mean gradient (r = 0.42; P = 0.14). CONCLUSIONS: TAV function can be severely impacted by noncalcific and calcific mechanisms of tissue degeneration. Importantly, functional stenosis can occur in TAVs in the absence of obvious and significant calcification.


Asunto(s)
Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Hidrodinámica , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Microtomografía por Rayos X , Humanos , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Calcinosis/cirugía , Femenino , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Persona de Mediana Edad , Factores de Tiempo , Remoción de Dispositivos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Fenómenos Biomecánicos , Ensayo de Materiales , Grabación en Video
6.
Front Cardiovasc Med ; 11: 1373840, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38863894

RESUMEN

Introduction: Transcatheter mitral valve replacement (TMVR) is a valuable treatment option in patients with severe mitral regurgitation. Prior transapical transcatheter aortic valve replacement (TA-TAVR) may complicate the procedure and is therefore considered a relative contraindication. In this case report, the authors describe the successful TMVR as a tertiary cardiac surgery and transapical redo procedure. Case Summary: An 83-year-old male patient, suffering from dyspnoea and angina, was diagnosed with severe mitral valve regurgitation (MR). He had already undergone cardiac surgery in the form of coronary artery bypass grafting at the age of 64 and TA-TAVR at 79 years. After a failed attempt at mitral valve transcatheter edge-to-edge repair, he opted for TMVR. Pre-TMVR computed tomography simulation was used to analyse possible interactions between the prostheses and to predict the neo-left ventricular outflow tract (neo-LVOT). The operation was carried out without complications. There was no bleeding and the LV function remained unchanged. On MRI, the valves were perfectly aligned without any signs of paravalvular leakage or LVOT obstruction. The patient was discharged seven days postoperatively. At the one-year follow up, there was no need for rehospitalisation and the patient had clinically improved (from NYHA IV to II). Echocardiography demonstrated a mean transvalvular gradient of under 5 mmHg and no residual MR. Conclusion: A redo transapical access for TMVR as a tertiary cardiac operation can be easily performed. Pre-operative CT suggested good alignment of the aortic and mitral valved stent which was confirmed postoperatively.

7.
Int J Mol Sci ; 25(7)2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38612836

RESUMEN

One of the most important medical interventions for individuals with heart valvular disease is heart valve replacement, which is not without substantial challenges, particularly for pediatric patients. Due to their biological properties and biocompatibility, natural tissue-originated scaffolds derived from human or animal sources are one type of scaffold that is widely used in tissue engineering. However, they are known for their high potential for immunogenicity. Being free of cells and genetic material, decellularized xenografts, consequently, have low immunogenicity and, thus, are expected to be tolerated by the recipient's immune system. The scaffold ultrastructure and ECM composition can be affected by cell removal agents. Therefore, applying an appropriate method that preserves intact the structure of the ECM plays a critical role in the final result. So far, there has not been an effective decellularization technique that preserves the integrity of the heart valve's ultrastructure while securing the least amount of genetic material left. This study demonstrates a new protocol with untraceable cells and residual DNA, thereby maximally reducing any chance of immunogenicity. The mechanical and biochemical properties of the ECM resemble those of native heart valves. Results from this study strongly indicate that different critical factors, such as ionic detergent omission, the substitution of Triton X-100 with Tergitol, and using a lower concentration of trypsin and a higher concentration of DNase and RNase, play a significant role in maintaining intact the ultrastructure and function of the ECM.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Animales , Porcinos , Humanos , Niño , Xenoinjertos , Trasplante Heterólogo , Ingeniería de Tejidos
8.
J Clin Med ; 13(5)2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38592316

RESUMEN

Background. The significance of concomitant tricuspid regurgitation (TR) in the context of transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to analyze the severity of TR before and after TAVR with regard to short- and long-term survival and to analyze the influencing factors. Methods. In our retrospective analysis, TR before and after TAVR was examined and patients were classified into groups accordingly. Special attention was paid to patients with post-interventional changes in TR. Mortality after TAVR was considered the primary endpoint of the analysis and major complications according to the Valve Academic Research Consortium 3 (VARC3) were compared. Moreover, biomarkers and risk factors for worsening or improvement of TR through TAVR were analyzed. Results. Among 775 patients who underwent TAVR in our center between January 2009 and December 2019, 686 patients (89%) featured low- and 89 patients (11%) high-grade TR. High-grade pre-TAVR TR was associated with worse short- (30-day), mid- (2-year) and long-term survival up to 8 years. Even though in nearly half of the patients with high-grade TR the regurgitation improved within seven days after TAVR (n = 42/89), this did not result in a survival benefit for this subgroup. On the other hand, a worsening of low-grade TR was seen in more than 10% of the patients (n = 73/686), which was also associated with a worse prognosis. Predictors of worsening of TR after TAVR were adipositas, impaired right ventricular function and the presence of mild TR. Age, atrial fibrillation, COPD, impaired renal function and elevated cardiac biomarkers were risk factors for mortality after TAVR independent from the grade of TR. Conclusions. Not only pre-interventional, but also post-TAVR high-grade TR is associated with a worse prognosis after TAVR. TAVR can change concomitant tricuspid regurgitation, but improvement does not have any impact on short- and long-term survival. Worsening of TR after TAVR is possible and impairs the prognosis.

9.
Radiol Cardiothorac Imaging ; 6(2): e220197, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38483246

RESUMEN

Purpose To examine the relationship between smoking status and coronary volume-to-myocardial mass ratio (V/M) among individuals with coronary artery disease (CAD) undergoing CT fractional flow reserve (CT-FFR) analysis. Materials and Methods In this secondary analysis, participants from the ADVANCE registry evaluated for suspected CAD from July 15, 2015, to October 20, 2017, who were found to have coronary stenosis of 30% or greater at coronary CT angiography (CCTA) were included if they had known smoking status and underwent CT-FFR and V/M analysis. CCTA images were segmented to calculate coronary volume and myocardial mass. V/M was compared between smoking groups, and predictors of low V/M were determined. Results The sample for analysis included 503 current smokers, 1060 former smokers, and 1311 never-smokers (2874 participants; 1906 male participants). After adjustment for demographic and clinical factors, former smokers had greater coronary volume than never-smokers (former smokers, 3021.7 mm3 ± 934.0 [SD]; never-smokers, 2967.6 mm3 ± 978.0; P = .002), while current smokers had increased myocardial mass compared with never-smokers (current smokers, 127.8 g ± 32.9; never-smokers, 118.0 g ± 32.5; P = .02). However, both current and former smokers had lower V/M than never-smokers (current smokers, 24.1 mm3/g ± 7.9; former smokers, 24.9 mm3/g ± 7.1; never-smokers, 25.8 mm3/g ± 7.4; P < .001 [unadjusted] and P = .002 [unadjusted], respectively). Current smoking status (odds ratio [OR], 0.74 [95% CI: 0.59, 0.93]; P = .009), former smoking status (OR, 0.81 [95% CI: 0.68, 0.97]; P = .02), stenosis of 50% or greater (OR, 0.62 [95% CI: 0.52, 0.74]; P < .001), and diabetes (OR, 0.67 [95% CI: 0.56, 0.82]; P < .001) were independent predictors of low V/M. Conclusion Both current and former smoking status were independently associated with low V/M. Keywords: CT Angiography, Cardiac, Heart, Ischemia/Infarction Clinical trial registration no. NCT02499679 Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Femenino , Humanos , Masculino , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Corazón , Miocardio , Fumar/efectos adversos
10.
EuroIntervention ; 20(6): e376-e388, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506739

RESUMEN

BACKGROUND: There are limited data regarding treatment for failed balloon-expandable transcatheter heart valves (THVs) in redo-transcatheter aortic valve implantation (TAVI). AIMS: We aimed to assess THV performance, neoskirt height and expansion when performing redo-TAVI with the ACURATE platform inside a SAPIEN 3 (S3) compared to redo-TAVI with an S3 in an S3. METHODS: Redo-TAVI was performed on the bench using each available size of the S3, the ACURATE neo2 (ACn2) and the next-generation ACURATE Prime XL (AC XL) implanted at 2 different depths within 20 mm/23 mm/26 mm/29 mm S3s serving as the "failed" index THV. Hydrodynamic testing was performed to assess THV function. Multimodality assessment was performed using photography, X-ray, microcomputed tomography (micro-CT), and high-speed videos. RESULTS: The ACURATE in S3 combinations had favourable hydrodynamic performance compared to the S3 in S3 for all size combinations. In the 20 mm S3, redo-TAVI with the ACn2 had lower gradients compared to the S3 (mean gradient 16.3 mmHg for the ACn2 vs 24.7 mmHg for the 20 mm S3 in 20 mm S3). Pinwheeling was less marked for the ACURATE THVs than for the S3s. On micro-CT, the S3s used for redo-TAVI were underexpanded across all sizes. This was also observed for the ACURATE platform, but to a lesser extent. CONCLUSIONS: Redo-TAVI with an ACn2/AC XL within an S3 has favourable hydrodynamic performance and less pinwheeling compared to an S3 in S3. This comes at the price of a taller neoskirt.


Asunto(s)
Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Microtomografía por Rayos X , Catéteres , Válvulas Cardíacas
12.
Nat Rev Cardiol ; 21(4): 264-273, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37880496

RESUMEN

Aortic blood flow patterns are closely linked to the morphology and function of the left ventricle, aortic valve and aorta. These flow patterns demonstrate the exceptional adaptability of the cardiovascular system to maintain blood circulation under a broad range of haemodynamic workloads and can be altered in various pathophysiological states. For instance, normal ascending aortic systolic flow is predominantly laminar, whereas abnormal aortic systolic flow is associated with increased eccentricity, vorticity and flow reversal. These flow abnormalities result in reduced aortic conduit function and increased energy loss in the cardiovascular system. Emerging evidence details the association of these flow patterns with loss of aortic compliance, which leads to adverse left ventricular remodelling, poor tissue perfusion, and an increased risk of morbidity and death. In this Perspective article, we review the evidence for the link between aortic flow-related abnormalities and cardiovascular disease and how these changes in aortic flow patterns are emerging as a therapeutic target for aortic valve intervention in first-in-human studies.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Humanos , Válvula Aórtica/cirugía , Aorta , Hemodinámica , Velocidad del Flujo Sanguíneo/fisiología
13.
JACC Cardiovasc Imaging ; 17(2): 165-175, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37410009

RESUMEN

BACKGROUND: With growing adoption of coronary computed tomographic angiography (CTA), there is increasing evidence for and interest in the prognostic importance of atherosclerotic plaque volume. Manual tools for plaque segmentation are cumbersome, and their routine implementation in clinical practice is limited. OBJECTIVES: The aim of this study was to develop nomographic quantitative plaque values from a large consecutive multicenter cohort using coronary CTA. METHODS: Quantitative assessment of total atherosclerotic plaque and plaque subtype volumes was performed in patients undergoing clinically indicated coronary CTA, using an Artificial Intelligence-Enabled Quantitative Coronary Plaque Analysis tool. RESULTS: A total of 11,808 patients were included in the analysis; their mean age was 62.7 ± 12.2 years, and 5,423 (45.9%) were women. The median total plaque volume was 223 mm3 (IQR: 29-614 mm3) and was significantly higher in male participants (360 mm3; IQR: 78-805 mm3) compared with female participants (108 mm3; IQR: 10-388 mm3) (P < 0.0001). Total plaque increased with age in both male and female patients. Younger patients exhibited a higher prevalence of noncalcified plaque. The distribution of total plaque volume and its components was reported in every decile by age group and sex. CONCLUSIONS: The authors developed pragmatic age- and sex-stratified percentile nomograms for atherosclerotic plaque measures using findings from coronary CTA. The impact of age and sex on total plaque and its components should be considered in the risk-benefit analysis when treating patients. Artificial Intelligence-Enabled Quantitative Coronary Plaque Analysis work flows could provide context to better interpret coronary computed tomographic angiographic measures and could be integrated into clinical decision making.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Angiografía Coronaria/métodos , Inteligencia Artificial , Valor Predictivo de las Pruebas , Angiografía por Tomografía Computarizada/métodos , Tomografía Computarizada por Rayos X
14.
Int J Mol Sci ; 24(24)2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38139185

RESUMEN

Transcatheter pulmonary valve replacement is a minimally-invasive alternative treatment for right ventricular outflow tract dysfunction and has been rapidly evolving over the past years. Heart valve prostheses currently available still have major limitations. Therefore, one of the significant challenges for the future is the roll out of transcatheter tissue engineered pulmonary valve replacement to more patients. In the present study, biodegradable poly-ε-caprolactone (PCL) nanofiber scaffolds in the form of a 3D leaflet matrix were successfully seeded with human endothelial colony-forming cells (ECFCs), human induced pluripotent stem cell-derived MSCs (hMSCs), and porcine MSCs (pMSCs) for three weeks for the generation of 3D tissue-engineered tri-leaflet valved stent grafts. The cell adhesion, proliferation, and distribution of these 3D heart leaflets was analyzed using fluorescence microscopy and scanning electron microscopy (SEM). All cell lineages were able to increase the overgrown leaflet area within the three-week timeframe. While hMSCs showed a consistent growth rate over the course of three weeks, ECFSs showed almost no increase between days 7 and 14 until a growth spurt appeared between days 14 and 21. More than 90% of heart valve leaflets were covered with cells after the full three-week culturing cycle in nearly all leaflet areas, regardless of which cell type was used. This study shows that seeded biodegradable PCL nanofiber scaffolds incorporated in nitinol or biodegradable stents will offer a new therapeutic option in the future.


Asunto(s)
Células Madre Pluripotentes Inducidas , Poliésteres , Humanos , Animales , Porcinos , Poliésteres/farmacología , Ingeniería de Tejidos , Andamios del Tejido , Stents
15.
Radiol Cardiothorac Imaging ; 5(5): e220276, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37908552

RESUMEN

Purpose: To compare the clinical use of coronary CT angiography (CCTA)-derived fractional flow reserve (FFR) in individuals with and without diabetes mellitus (DM). Materials and Methods: This secondary analysis included participants (enrolled July 2015 to October 2017) from the prospective, multicenter, international The Assessing Diagnostic Value of Noninvasive CT-FFR in Coronary Care (ADVANCE) registry (ClinicalTrials.gov identifier, NCT02499679) who were evaluated for suspected coronary artery disease (CAD), with one or more coronary stenosis ≥30% on CCTA images, using CT-FFR. CCTA and CT-FFR findings, treatment strategies at 90 days, and clinical outcomes at 1-year follow-up were compared in participants with and without DM. Results: The study included 4290 participants (mean age, 66 years ± 10 [SD]; 66% male participants; 22% participants with DM). Participants with DM had more obstructive CAD (one or more coronary stenosis ≥50%; 78.8% vs 70.6%, P < .001), multivessel CAD (three-vessel obstructive CAD; 18.9% vs 11.2%, P < .001), and proportionally more vessels with CT-FFR ≤ 0.8 (74.3% vs 64.6%, P < .001). Treatment reclassification by CT-FFR occurred in two-thirds of participants which was consistent regardless of the presence of DM. There was a similar graded increase in coronary revascularization with declining CT-FFR in both groups. At 1 year, presence of DM was associated with higher rates of major adverse cardiovascular events (hazard ratio, 2.2; 95% CI: 1.2, 4.1; P = .01). However, no between group differences were observed when stratified by stenosis severity (<50% or ≥50%) or CT-FFR positivity. Conclusion: Both anatomic CCTA findings and CT-FFR demonstrated a more complex pattern of CAD in participants with versus without DM. Rates of treatment reclassification were similar regardless of the presence of DM, and DM was not an adverse prognostic indicator when adjusted for diameter stenosis and CT-FFR.Clinical trial registration no. NCT 02499679Keywords: Fractional Flow Reserve, CT Angiography, Diabetes Mellitus, Coronary Artery Disease Supplemental material is available for this article. See also the commentary by Ghoshhajra in this issue.© RSNA, 2023.

16.
Front Cardiovasc Med ; 10: 1288278, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38028444

RESUMEN

Late balloon valvuloplasty can be used to treat under-expansion-related transcatheter heart valve (THV) dysfunction. Whether this can be performed following redo-THV implantation is unknown. Herein, we report a case of a 72-year-old male presenting with symptomatic gradient elevation following redo mitral valve-in-valve implantation. The patient was successfully treated with late balloon valvuloplasty with gradient improvement. In conclusion, late valvuloplasty is effective even with several layers of valves. However, larger studies are required to clarify the role of this approach further.

18.
Curr Cardiol Rep ; 25(11): 1425-1431, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37815660

RESUMEN

PURPOSE OF REVIEW: As TAVR is increasingly performed on younger patients with a longer life expectancy, the number of redo-TAVR procedures is likely to increase in the coming years. Limited data is currently available on this sometimes challenging procedure. We provide a summary of currently published literature on management of patients with a failed transcatheter aortic valve. RECENT FINDINGS: Recent registry data have increased the clinical knowledge on redo-TAVR. Additionally, numerous bench studies have provided valuable insights into the technical aspects of redo-TAVR with various combinations of valve types. Redo-TAVR can be performed safely in selected cases with a high procedural success and good short-term outcomes. However, at present, the procedure remains relatively infrequent and many patients are not eligible. Bench testing can be useful to understand important concepts such as valve expansion, neoskirt, leaflet overhang, and leaflet deflection as well as their potential clinical implications.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA