Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Intervalo de año de publicación
1.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1527808

RESUMEN

ABSTRACT Purpose: To determine normal corneal tomographic parameters in children and adolescents without corneal disease or atopy diagnosis. Methods: This descriptive cross-sectional study evaluated patients aged 8-16 years who underwent a complete slit-lamp biomicroscopic examination and tomographic corneal evaluation by a dual Scheimpflug analyzer, excluding those with ocular disease (including allergic conjunctivitis) or a positive prick test for systemic atopies. Results: A total of 170 patients were evaluated, and 34 patients (68 eyes) were analyzed once the exclusion criteria were applied. The sample's mean age was 10.76 ± 2.31 years; with 19 (55.9%) men and 15 (44.1%) women. The mean keratometry in the flat meridian (Kflat), steep meridian (Ksteep), and maximum (Kmax) were 42.37 ± 1.63D, 43.53 ± 1.65D, and 43.90 ± 1.73D, respectively. The mean values for corneal asphericity (ε2) and thinnest point were 0.28 ± 0.11 and 550.20 ± 37.90 μm, respectively. The inferior-superior asymmetry ratio (I-S) and coma were 0.74 ±0.59D and 0.28 ± 0.12D, respectively. Conclusion: The knowledge of normal corneal tomographic parameters and their variation in children and adolescents without corneal disease or atopy may be useful for diagnosing keratoconus and initiating early disease treatment.


RESUMO Objetivo: Identificar parâmetros tomográficos de normalidade em córneas de crianças e adolescentes sem a presença de atopias sistêmicas e alergias oculares. Métodos: Este estudo descritivo transversal avaliou pacientes com idade entre 8 e 16 anos que foram submetidos a exame biomicroscópico completo por lâmpada de fenda e avaliação tomográfica da córnea por tomógrafo dual Scheimpflug, excluindo pacientes com doença ocular (incluindo conjuntivite alérgica) ou prick test positivo para atopias sistêmicas. Resultados: Cento e setenta pacientes foram avaliados e após cumpridos os critérios de exclusão, 34 (68 olhos) foram analisados. A média etária da amostra foi 10,76 ± 2,31 anos; 19 (55,9%) eram meninos e 15 (44,1%) meninas. A média da ceratometria em dioptrias (D) no meridiano mais plano (Kflat), mais curvo (Ksteep) e máxima (Kmax) foram 42,37 ± 1,63D, 43,53 ± 1,65D e 43,90 ± 1,73D, respectivamente. Os valores médios da asfericidade corneana (ε2) e do ponto mais fino da córnea foram 0,28 ± 0,11 e 550,20 ± 37,90 micras (μm). A assimetria corneana inferior-superior (I-S) e coma foi em média 0,74 ± 0,59D e 0,28 ± 0,12D, respectivamente. Conclusão: O conhecimento dos valores médios e sua variação de parâmetros tomográficos da córnea em crianças e adolescentes sem atopias sistêmicas ou alergias oculares pode ser útil para o diagnóstico precoce do ceratocone e o seu tratamento em estágio inicial.

2.
Arq Bras Oftalmol ; 87(1): 0048, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35857975

RESUMEN

PURPOSE: To determine normal corneal tomographic parameters in children and adolescents without corneal disease or atopy diagnosis. METHODS: This descriptive cross-sectional study evaluated patients aged 8-16 years who underwent a complete slit-lamp biomicroscopic examination and tomographic corneal evaluation by a dual Scheimpflug analyzer, excluding those with ocular disease (including allergic conjunctivitis) or a positive prick test for systemic atopies. RESULTS: A total of 170 patients were evaluated, and 34 patients (68 eyes) were analyzed once the exclusion criteria were applied. The sample's mean age was 10.76 ± 2.31 years; with 19 (55.9%) men and 15 (44.1%) women. The mean keratometry in the flat meridian (Kflat), steep meridian (Ksteep), and maximum (Kmax) were 42.37 ± 1.63D, 43.53 ± 1.65D, and 43.90 ± 1.73D, respectively. The mean values for corneal asphericity (ε2) and thinnest point were 0.28 ± 0.11 and 550.20 ± 37.90 µm, respectively. The inferior-superior asymmetry ratio (I-S) and coma were 0.74 ±0.59D and 0.28 ± 0.12D, respectively. CONCLUSION: The knowledge of normal corneal tomographic parameters and their variation in children and adolescents without corneal disease or atopy may be useful for diagnosing keratoconus and initiating early disease treatment.

3.
Am J Med Genet A ; 182(11): 2641-2645, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32945116

RESUMEN

Down syndrome is the most common chromosomal disorder, affecting 1/700 live births. Among the clinical findings, one constant concern is the high prevalence of visual disorders that, if left untreated, can negatively affect child development. The aim of this study was to determine the prevalence of ophthalmological findings among patients who attended an outpatient clinic for patients with Down syndrome in southern Brazil between 2005 and 2016. A cross-sectional study including 1,207 patients medical records were done, which 492 (40.8%) had some ophthalmological disorder. These data were subjected to descriptive analysis using Statistica software. Among the 492 patients with any ophthalmological disease, the need for glasses was found in 434 (36%) patients, keratoconus in 254 (42.1%), congenital cataract in 27 (15.1%), nasolacrimal duct obstruction in 25 (2.0%), strabismus in 22 (1.9%), nystagmus in four (0.3%), and juvenile cataract in two (0.2%). Two young adults with keratoconus underwent corneal transplantation. Although the prevalence of an ophthalmological disease among the present sample (40.8%) was lower than described in the current literature, it still reinforced the importance of routine and early evaluations in infants. These should begin at 6 months of age and be repeated half-year until 2 years old, annually until 7 years old, biennial in adolescents, and triennial in adults and elderly. Our findings of a high frequency of keratoconus support a detailed corneal study in such patients for early detection and treatment.


Asunto(s)
Síndrome de Down/diagnóstico , Oftalmopatías/diagnóstico , Obstrucción del Conducto Lagrimal/diagnóstico , Adolescente , Adulto , Brasil/epidemiología , Catarata/complicaciones , Niño , Preescolar , Estudios Transversales , Síndrome de Down/complicaciones , Anomalías del Ojo/complicaciones , Oftalmopatías/complicaciones , Femenino , Humanos , Lactante , Recién Nacido , Queratocono/complicaciones , Obstrucción del Conducto Lagrimal/complicaciones , Masculino , Nistagmo Congénito/complicaciones , Estudios Retrospectivos , Programas Informáticos , Estrabismo/complicaciones , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...