Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
IEEE Trans Biomed Eng ; 71(2): 484-493, 2024 Feb.
Article En | MEDLINE | ID: mdl-37610892

OBJECTIVE: Non-invasive human machine interfaces (HMIs) have high potential in medical, entertainment, and industrial applications. Traditionally, surface electromyography (sEMG) has been used to track muscular activity and infer motor intention. Ultrasound (US) has received increasing attention as an alternative to sEMG-based HMIs. Here, we developed a portable US armband system with 24 channels and a multiple receiver approach, and compared it with existing sEMG- and US-based HMIs on movement intention decoding. METHODS: US and motion capture data was recorded while participants performed wrist and hand movements of four degrees of freedom (DoFs) and their combinations. A linear regression model was used to offline predict hand kinematics from the US (or sEMG, for comparison) features. The method was further validated in real-time for a 3-DoF target reaching task. RESULTS: In the offline analysis, the wearable US system achieved an average [Formula: see text] of 0.94 in the prediction of four DoFs of the wrist and hand while sEMG reached a performance of [Formula: see text]= 0.60. In online control, the participants achieved an average 93% completion rate of the targets. CONCLUSION: When tailored for HMIs, the proposed US A-mode system and processing pipeline can successfully regress hand kinematics both in offline and online settings with performances comparable or superior to previously published interfaces. SIGNIFICANCE: Wearable US technology may provide a new generation of HMIs that use muscular deformation to estimate limb movements. The wearable US system allowed for robust proportional and simultaneous control over multiple DoFs in both offline and online settings.


Wearable Electronic Devices , Wrist , Humans , Wrist/diagnostic imaging , Biomechanical Phenomena , Hand/diagnostic imaging , Wrist Joint , Movement , Electromyography/methods
2.
IEEE Trans Biomed Eng ; PP2023 Dec 06.
Article En | MEDLINE | ID: mdl-38055363

OBJECTIVE: Non-invasive identification of motoneuron (MN) activity commonly uses electromyography (EMG). However, surface EMG (sEMG) detects only superficial sources, at less than approximately 10-mm depth. Intramuscular EMG can detect deep sources, but it is limited to sources within a few mm of the detection site. Conversely, ultrasound (US) images have high spatial resolution across the whole muscle cross-section. The activity of MNs can be extracted from US images due to the movements that MN activation generates in the innervated muscle fibers. Current US-based decomposition methods can accurately identify the location and average twitch induced by MN activity. However, they cannot accurately detect MN discharge times. METHODS: Here, we present a method based on the convolutive blind source separation of US images to estimate MN discharge times with high accuracy. The method was validated across 10 participants using concomitant sEMG decomposition as the ground truth. RESULTS: 140 unique MN spike trains were identified from US images, with a rate of agreement (RoA) with sEMG decomposition of 87.4 ± 10.3%. Over 50% of these MN spike trains had a RoA greater than 90%. Furthermore, with US, we identified additional MUs well beyond the sEMG detection volume, at up to >30 mm below the skin. CONCLUSION: The proposed method can identify discharges of MNs innervating muscle fibers in a large range of depths within the muscle from US images. SIGNIFICANCE: The proposed methodology can non-invasively interface with the outer layers of the central nervous system innervating muscles across the full cross-section.

3.
Article En | MEDLINE | ID: mdl-37703141

Ultrasound (US) muscle image series can be used for peripheral human-machine interfacing based on global features, or even on the decomposition of US images into the contributions of individual motor units (MUs). With respect to state-of-the-art surface electromyography (sEMG), US provides higher spatial resolution and deeper penetration depth. However, the accuracy of current methods for direct US decomposition, even at low forces, is relatively poor. These methods are based on linear mathematical models of the contributions of MUs to US images. Here, we test the hypothesis of linearity by comparing the average velocity twitch profiles of MUs when varying the number of other concomitantly active units. We observe that the velocity twitch profile has a decreasing peak-to-peak amplitude when tracking the same target motor unit at progressively increasing contraction force levels, thus with an increasing number of concomitantly active units. This observation indicates non-linear factors in the generation model. Furthermore, we directly studied the impact of one MU on a neighboring MU, finding that the effect of one source on the other is not symmetrical and may be related to unit size. We conclude that a linear approximation is partly limiting the decomposition methods to decompose full velocity twitch trains from velocity images, highlighting the need for more advanced models and methods for US decomposition than those currently employed.


Ultrasonography , Humans , Electromyography , Linear Models
...