1.
J AOAC Int ; 97(5): 1463-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25903001

RESUMEN

The method for the determination of 12 organophosphorus pesticides in solid waste was established. The organophosphorus pesticides were analyzed by Soxhlet extraction or accelerated solvent extraction (ASE)-SPE cartridge-flame photometric detector (FPD), and leaching solution by rotary oscillation-positive pressure filtration-liquid-liquid extraction-SPE cartridge-FPD. The differences of extraction efficiencies between Soxhlet and ASE were compared. Solvent of Soxhlet extraction, purification and recovery of organophosphorus pesticides in leaching conditions were also studied. The recoveries were 54.2-119.8%, and the average recovery was 87.7%. The RSD was 1.89-9.10% (n = 6), the average RSD was 6.88%, and the detection limit was 0.27-0.69 µg/kg.


Asunto(s)
Cromatografía de Gases/métodos , Compuestos Organofosforados/análisis , Residuos de Plaguicidas/análisis , Residuos Sólidos/análisis , Límite de Detección , Extracción Líquido-Líquido , Extracción en Fase Sólida