Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Pediatr Pulmonol ; 58(1): 122-129, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36169007

RESUMEN

INTRODUCTION: Whether lung ultrasound (LUS) can be used for pathogenic diagnosis remains controversial. This study was conducted to clarify whether ultrasound has diagnostic value for etiology. METHODS: A total of 135 neonatal pneumonia patients with an identified pathogen were enrolled from the newborn intensive care units of 10 tertiary hospitals in China. The study ran from November 2020 to December 2021. The infants were divided into various groups according to pathogens, time of infection, gestational age, and disease severity. The distribution of pleural line abnormalities, B-line signs, and pulmonary consolidation, as well as the incidence of air bronchogram and pleural effusion based on LUS, were compared between these groups. RESULTS: There were significant differences in pulmonary consolidation. The sensitivity and specificity of the diagnosis of severe pneumonia based on the extent of pulmonary consolidation were 83.3% and 85.2%, respectively. The area under the receiver operating characteristic curve for the identification of mild or severe pneumonia based on the distribution of pulmonary consolidation was 0.776. CONCLUSION: LUS has good performance in diagnosing and differentiating the severity of neonatal pneumonia but cannot be used for pathogenic identification in the early stages of pneumonia.


Asunto(s)
Neumonía , Lactante , Humanos , Recién Nacido , Estudios Prospectivos , Neumonía/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Ultrasonografía , Sensibilidad y Especificidad
2.
J Matern Fetal Neonatal Med ; 35(5): 1003-1016, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34182870

RESUMEN

Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases. Nevertheless, in the published literatures, the LUS images may display a significant variation in technical execution, while scanning parameters may influence diagnostic accuracy. The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS. As expected, the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US). Consequently, having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs. The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS. Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1) select a high-end equipment with high-frequency linear array transducer (12-14 MHz). (2) Choose preset suitable for lung examination or small organs. (3) Keep the probe perpendicular to the ribs or parallel to the intercostal space. (4) Set the scanning depth at 4-5 cm. (5) Set 1-2 focal zones and adjust them close to the pleural line. (6) Use fundamental frequency with speckle reduction 2-3 or similar techniques. (7) Turn off spatial compounding imaging. (8) Adjust the time-gain compensation to get uniform image from the near-to far-field.


Asunto(s)
Enfermedades del Recién Nacido , Neumonía , Humanos , Recién Nacido , Pulmón/diagnóstico por imagen , Reproducibilidad de los Resultados , Ultrasonografía
3.
Nan Fang Yi Ke Da Xue Xue Bao ; 36(7): 887-91, 2016 Jun 20.
Artículo en Chino | MEDLINE | ID: mdl-27435763

RESUMEN

OBJECTIVE: To investigate the effect of premature rupture of the membrane (PROM) on neonatal complications in premature infants. METHODS: The registration information of 7684 preterm infants with gestational age <37 weeks were collected from the cooperative units in the task group between January 1, 2014 to December 31, 2014. Specially trained personnel from each cooperative units filled in the unified form in a standardized format to record the gender, gestational age, birth weight, PROM, placental abruption, antenatal corticosteroid, Apgar score, amniotic fluid pollution, and complications of the infants. The data were analyzed comparatively between the cases with PROM and those without (control). RESULTS: The preterm mortality rate was significantly lower but the incidences of ICH, NEC, ROP and BPD were significantly higher in PROM group than in the control group (P<0.05). The 95% confidence interval of the OR value was <1 for mortality, and was >1 for ICH, NEC, ROP and BPD. After adjustment for gestational age, birth weight, gender, mode of delivery, placental abruption, placenta previa, prenatal hormones, gestational diabetes mellitus (GDM), gestational period hypertension and 5-min Apgar score <7, the incidences of NEC, ROP and BPD were significantly different between the two groups (P<0.05) with 95% confidence interval of OR value >1, but the mortality rate and incidence of ICH were not significantly different between the two groups (P>0.05). CONCLUSION: PROM is a risk factor for NEC, ROP and BPD in preterm infants, and adequate intervention of PROM can reduce the incidences of such complications as NEC, ROP and BPD in the infants.


Asunto(s)
Rotura Prematura de Membranas Fetales/patología , Edad Gestacional , Enfermedades del Recién Nacido/etiología , Recien Nacido Prematuro , Puntaje de Apgar , Peso al Nacer , Femenino , Humanos , Incidencia , Recién Nacido , Embarazo , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA