Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 14 de 14
1.
Circ J ; 86(12): 1990-1997, 2022 11 25.
Article En | MEDLINE | ID: mdl-36047087

BACKGROUND: Balloon atrial septostomy (BAS) is an essential catheterization procedure for congenital heart lesions. Recently, a balloon catheter for static BAS was approved for the first time in Japan as an alternative to the conventional pull-through BAS. Despite the expected increase in the use of static BAS, reports on its safety are scarce worldwide.Methods and Results: Data on static and pull-through BAS registered in a national registry between 2016 and 2018 were collected. During the study period, 247 sessions of static BAS and 588 sessions of pull-through BAS were performed on a total of 674 patients. Patients who underwent static BAS were older (P<0.001). The incidence of serious adverse events (4.3% vs. 0.9%, P=0.03) and the overall incidence of adverse events (8.1% vs. 3.2%, P=0.03) were higher in static BAS than in pull-through BAS. Among patients who underwent static BAS, the risk factor for adverse events was a body weight <3 kg at the time of the procedure (odds ratio: 4.3 [confidence interval: 1.7-11], P=0.003). CONCLUSIONS: This nationwide study revealed differences in patient background between static and pull-through BAS, as well as a higher incidence of adverse events related to static BAS. Patients weighing <3 kg are at high risk for adverse events after static BAS and may require surgical and circulatory support backup.


Cardiac Surgical Procedures , Transposition of Great Vessels , Humans , Cardiac Surgical Procedures/methods , Catheterization/adverse effects , Risk Factors , Odds Ratio , Registries , Transposition of Great Vessels/epidemiology , Transposition of Great Vessels/etiology , Transposition of Great Vessels/surgery
2.
Cardiovasc Revasc Med ; 37: 118-119, 2022 04.
Article En | MEDLINE | ID: mdl-34483075

Regulatory approval processes for medical devices in Japan and the United States of America (US) often require similar clinical trials to establish safety and effectiveness. The Harmonization by Doing (HBD) program provides a collaborative environment for communication between regulators, academics and industry, facilitating the design and conduct of US/Japanese clinical trials supporting approval in both countries.


Atherectomy, Coronary , Coronary Artery Disease , Percutaneous Coronary Intervention , Vascular Calcification , Atherectomy , Atherectomy, Coronary/adverse effects , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Humans , Japan , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome , United States , Vascular Calcification/diagnostic imaging , Vascular Calcification/therapy
3.
Intern Med ; 60(2): 161-166, 2021 Jan 15.
Article En | MEDLINE | ID: mdl-32188811

Although a domestic trial in Japan revealed that Absorb bioresorbable vascular scaffold (BVS) has no inferiority to everolimus-eluting stent (EES) cohort in the primary endpoint of the target lesion failure at 12 months, the scaffold/stent thrombosis (ST) rates with the BVS at 24 months were higher than those with the EES (Absorb BVS 3.1% vs. EES 1.5%), the ST rate of 3.1% with Absorb BVS is not an acceptable level in Japan. A cause-of-ST analysis revealed that cases in which diagnostic imaging and ensuing post-dilatation had been performed appropriately had lower ST rates than those without such management (within 1 year: 1.37% vs. 7.69%, from 1 to 2 years: 0.00% vs. 8.33%). Therefore, a further evaluation was needed to confirm that the ST rate with the Absorb BVS would be reduced by a proper implementation procedure. Regulatory approval was given conditionally to initiate rigorous post-marketing data collection in order to ensure the proper use of this device in limited facilities. The One-year Use-Result Survey in Japan for the Absorb BVS revealed no instances of ST. This approach to reducing the premarket regulatory burden of clinical trials and enhancing the post-marketing commitments of medical device regulation is useful for expediting patient access to innovative medical devices.


Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Absorbable Implants , Everolimus , Humans , Japan , Prosthesis Design , Treatment Outcome
4.
J Artif Organs ; 24(1): 90-101, 2021 Mar.
Article En | MEDLINE | ID: mdl-33079285

Further development of medical devices for children is required in Japan, but the development of such devices is delayed compared to that of medical devices for adults. Herein, we investigated policies for advancing the development of pediatric medical devices in Japan and the United States. Considering the achievements of each policy, we proposed a strategy to promote further development of pediatric medical devices in Japan. We investigated policies for supporting the development of pediatric medical devices and approved cases in Japan and the United States by searching contents of websites of regulatory bodies and other related administrations, and scientific papers. We found the main six policies in Japan and nine main policies in the United States for the development of pediatric medical devices. In the United States, various measures have initiated mainly in the 2000s, while in Japan, the main measures have been in place since 2013. Similarities were found in both countries, such as subsidies for application fees and research and development expenses, exemption of requirements for regulatory approval, and priority review and consultation by the regulatory body. Our study revealed that there are similarities in initiatives by both countries. To promote further development of pediatric medical devices in the future, improvements to expediting the review process to approval by the regulatory body, global development, and implementation of alternative measures to ensure the efficacy and safety of the device instead of large-scale clinical trials should be anticipated through cooperation among industry, government, and academia.


Device Approval/legislation & jurisprudence , Pediatrics/instrumentation , Child , Humans , Japan , United States
5.
Heart Vessels ; 36(2): 155-162, 2021 Feb.
Article En | MEDLINE | ID: mdl-32776235

In 2013, a drug-coated balloon catheter (DCB) (SeQuent Please) for the treatment of coronary in-stent restenosis (ISR) was approved in Japan. The pre-marketing Japan domestic NP001 study demonstrated better outcomes of the DCB (n = 138) compared to plain balloon angioplasty (n = 72). After the introduction to marketing, a post-marketing surveillance (PMS) (n = 396) was conducted to evaluate the safety and efficacy of the DCB in Japanese routine clinical practice. The aim of this paper was to assess differences between the pre-marketing NP001 study and the PMS. Compared to the NP001 study, more complex lesions were treated in the PMS (type B2/C: 69.0% vs 20.4%, total occlusion: 11.2% vs 0%, p < 0.001, respectively) and target lesion was more frequently ISR related to drug-eluting stent (DES) (79.5% vs 39.4%, p < 0.001). Regarding clinical outcomes, the rate of target lesion revascularization (TLR) was higher in the PMS than in the NP001 study (TLR: 12.9% at 7 months and 17.6% at 12 months vs 2.8% at 6 months, p = 0.001, p < 0.001, respectively). Multivariable logistic regression analysis revealed that DES-ISR was a risk factor of TLR after DCB treatment for ISR (odds ratio: 5.77, 95% CI 1.75-18.95, p = 0.004). Among representative published trials using DCB for ISR, clinical outcomes are often worse in DES-ISR trials than those in bare metal stent-ISR trials. The rates of TLR in previous DES-ISR trials are similar to that in the current PMS (TLR at 12 months: 22.1% for ISAR-DESIRE 3, 15.3% for PEPCAD-DES, and 13.0% for RIBS IV). The effectiveness and safety of DCB for coronary ISR have been confirmed in the Japanese real-world survey. PMS would be useful to evaluate the safety and effectiveness of medical products throughout their total life cycles.


Angioplasty, Balloon, Coronary/methods , Coated Materials, Biocompatible , Coronary Restenosis/surgery , Drug-Eluting Stents , Aged , Coronary Angiography , Coronary Restenosis/diagnosis , Female , Humans , Japan , Male , Paclitaxel , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
6.
Circ J ; 84(9): 1568-1574, 2020 08 25.
Article En | MEDLINE | ID: mdl-32684539

BACKGROUND: Stent thrombosis (ST) is a serious complication after drug-eluting stents (DES) implantation. To identify the risk factors of mortality following ST, we evaluated adverse event reports used for safety measures after approval.Methods and Results:Between July 2004 and August 2019, 2,887 ST case reports were submitted to the Pharmaceutical and Medical Device Agency. Reports of probable or possible ST (n=604), with insufficient data regarding in-hospital outcome or duration between procedure and ST occurrence (n=37) or duplicate reports (n=191) were excluded. Accordingly, 2,045 reports with definite ST were analyzed. Among the subjects, there were 286 in-hospital deaths (14.0%). Multivariate logistic regression analysis revealed that left main trunk (LMT) (odds ratio [OR]: 4.76, 95% confidence interval [CI]: 3.26-6.96), chronic heart failure (CHF) (OR: 2.88, 95% CI: 1.61-5.14), hemodialysis (OR: 2.69, 95% CI: 1.66-4.36), prior stroke (OR: 2.28, 95% CI: 1.15-4.51), over 70 years old (OR: 1.62, 95% CI: 1.22-2.16), and right coronary artery (OR: 0.41, 95% CI: 0.27-0.63) were independent factors for in-hospital death after DES-ST. CONCLUSIONS: LMT, CHF, hemodialysis, prior stroke, and older age were independently associated with higher risk of in-hospital death following DES-ST. If target patients have these factors, maximum preventive strategies against ST occurrence, including adequate dual-antiplatelet therapy duration and optimal DES deployment procedures, are required.


Coronary Thrombosis/etiology , Coronary Thrombosis/mortality , Drug-Eluting Stents/adverse effects , Hospital Mortality , Percutaneous Coronary Intervention/adverse effects , Age Factors , Aged , Aged, 80 and over , Coronary Artery Disease/complications , Coronary Artery Disease/epidemiology , Coronary Thrombosis/epidemiology , Coronary Thrombosis/prevention & control , Female , Heart Failure/complications , Heart Failure/epidemiology , Humans , Japan/epidemiology , Male , Middle Aged , Platelet Aggregation Inhibitors/therapeutic use , Renal Dialysis/adverse effects , Risk Factors , Stroke/complications , Stroke/epidemiology , Treatment Outcome
7.
J Cardiol ; 74(1): 13-18, 2019 Jul.
Article En | MEDLINE | ID: mdl-31005388

The indication for MitraClip (Abbott Vascular, Santa Clara, CA, USA) in the USA is degenerative mitral regurgitation (DMR), but the Japanese indication includes both DMR and functional mitral regurgitation (FMR), in patients without severe left ventricular dysfunction. One of the reasons for this difference is that the Japanese Circulation Society submitted a formal request to the Japanese government for early approval of MitraClip for both DMR and FMR on the basis of unmet medical need for MR patients resistant to medical therapy, but at prohibitive risk for mitral valve surgery. Here, we describe the regulatory approval review process of MitraClip in Japan. Clinical data from outside Japan indicated that MitraClip provides significant improvements from baseline in New York Heart Association Class and hospitalizations for heart failure due to the reduction of MR grade without adversely affecting long-term prognosis in FMR patients as well as DMR patients. Also, a Japanese domestic trial showed a favorable acute procedural success rate without serious adverse events with MitraClip in both DMR and FMR patients. Further, it is considered in Japan that improvement of MR mechanically is clinically important in both DMR and FMR, in patients without severe left ventricular dysfunction. On the basis of these considerations, the MitraClip was approved in Japan for indications of both DMR and FMR with preserved cardiac function in patients at prohibitive risk for mitral valve surgery.


Device Approval/legislation & jurisprudence , Heart Valve Prosthesis Implantation/instrumentation , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Risk Assessment/legislation & jurisprudence , Aged , Female , Heart Valve Prosthesis Implantation/legislation & jurisprudence , Heart Valve Prosthesis Implantation/methods , Humans , Japan , Male , Mitral Valve/physiopathology , Mitral Valve Insufficiency/physiopathology , Patient Selection , Risk Assessment/methods , Treatment Outcome , United States
8.
Circ J ; 82(7): 1951-1958, 2018 06 25.
Article En | MEDLINE | ID: mdl-29794375

BACKGROUND: The introduction of transcatheter aortic valve implantation (TAVI) into Japan was strictly controlled to optimize patient outcomes. The goal of this study was to assess if increasing experience during the introduction of this procedure was associated with outcomes.Methods and Results:The initial 1,752 patients registered in the Japanese national TAVI registry were included in the study. The association between operator procedure number and incidence of the early safety endpoint at 30 days (ESE30) as defined in the Valve Academic Research Consortium-2 consensus document was evaluated. Patients were divided into 4 groups by quartiles of procedure count (Groups I-IV in order of increasing number of procedures). Median patient age was 85 years, and 30.5% were male. The 30-day mortality rate was 1.4% (n=24), and 78 patients (7.9%) experienced 95 ESE30. Among the variables included in the model, ESE30 was associated with non-transfemoral approach (P=0.004), renal dysfunction (Cr >2.0 mg/dL) (P=0.01) and NYHA class III/IV (P=0.04). ESE30 incidence was not significantly different between Groups I-III and Group IV. Spline plots demonstrated that experience of 15-20 cases in total was needed to achieve a consistent low risk of ESE30. CONCLUSIONS: Increasing experience was associated with better outcomes, but to a lesser degree than in previous reports. Our findings suggested that the risks associated with the learning curve process were appropriately mitigated.


Learning Curve , Transcatheter Aortic Valve Replacement/methods , Aged, 80 and over , Female , Humans , Incidence , Japan , Male , Models, Theoretical , Postoperative Complications/mortality , Registries/standards , Risk Factors , Survival Analysis , Transcatheter Aortic Valve Replacement/mortality
9.
Circ J ; 82(6): 1487-1490, 2018 05 25.
Article En | MEDLINE | ID: mdl-29563353

A prospective randomized clinical trial showed that the BioFreedom stent (Biosensors International), which is a polymer-free and carrier-free drug-coated stent, was significantly superior to a bare-metal stent (BMS) in patients at high bleeding risk who were receiving a 1-month course of dual antiplatelet therapy (DAPT). However, the stent thrombosis rate (2.01% for BioFreedom vs. 2.20% for BMS) was 4-6-fold higher than that of approved drug-eluting stents based on real-world data in Japan. Furthermore, the frequency of stent thrombosis at more than 1 month with the BioFreedom stent was slightly higher than that at less than 1 month. This result suggested that it would not be acceptable to stop DAPT universally at 1 month. Thus, the target patients for the BioFreedom stent are unspecified patients at high bleeding risk needing to continue DAPT for as long as necessary in Japan. Therefore, based on the pre- and post-marketing balance of medical devices regulations, regulatory approval was given for unspecified patients conditionally upon real-world data collection of 2,000 patients with a Use-Results Survey, instead of conducting additional pre-marketing clinical trial(s). The Use-Results Survey System is part of a strategy to expedite patients' access to innovative medical devices and to accelerate the development of medical devices.


Drug-Eluting Stents/standards , Device Approval , Drug-Eluting Stents/adverse effects , Hemorrhage/etiology , Humans , Japan , Surveys and Questionnaires , Treatment Outcome
10.
Development ; 138(9): 1771-82, 2011 May.
Article En | MEDLINE | ID: mdl-21447557

In general, cell proliferation and differentiation show an inverse relationship, and are regulated in a coordinated manner during development. Embryonic cardiomyocytes must support embryonic life by functional differentiation such as beating, and proliferate actively to increase the size of the heart. Therefore, progression of both proliferation and differentiation is indispensable. It remains unknown whether proliferation and differentiation are related in these embryonic cardiomyocytes. We focused on abnormal phenotypes, such as hyperproliferation, inhibition of differentiation and enhanced expression of cyclin D1 in cardiomyocytes of mice with mutant jumonji (Jmj, Jarid2), which encodes the repressor of cyclin D1. Analysis of Jmj/cyclin D1 double mutant mice showed that Jmj was required for normal differentiation and normal expression of GATA4 protein through cyclin D1. Analysis of transgenic mice revealed that enhanced expression of cyclin D1 decreased GATA4 protein expression and inhibited the differentiation of cardiomyocytes in a CDK4/6-dependent manner, and that exogenous expression of GATA4 rescued the abnormal differentiation. Finally, CDK4 phosphorylated GATA4 directly, which promoted the degradation of GATA4 in cultured cells. These results suggest that CDK4 activated by cyclin D1 inhibits differentiation of cardiomyocytes by degradation of GATA4, and that initiation of Jmj expression unleashes the inhibition by repression of cyclin D1 expression and allows progression of differentiation, as well as repression of proliferation. Thus, a Jmj-cyclin D1 pathway coordinately regulates proliferation and differentiation of cardiomyocytes.


Cell Differentiation/genetics , Cell Proliferation , Cyclin D1/physiology , Heart/embryology , Myocytes, Cardiac/physiology , Nerve Tissue Proteins/physiology , Animals , Cyclin D1/genetics , Embryo, Mammalian , GATA4 Transcription Factor/genetics , GATA4 Transcription Factor/metabolism , Gene Expression Regulation, Developmental , HeLa Cells , Heart/physiology , Humans , Mice , Mice, Inbred C3H , Mice, Knockout , Myocytes, Cardiac/metabolism , Nerve Tissue Proteins/genetics , Polycomb Repressive Complex 2 , Signal Transduction , Time Factors
11.
J Biol Chem ; 284(2): 733-9, 2009 Jan 09.
Article En | MEDLINE | ID: mdl-19010785

Covalent modifications of histone tails have critical roles in regulating gene expression. Previously, we identified the jumonji (jmj, Jarid2) gene, the jmjC domain, and a Jmj family. Recently, many Jmj family proteins have been shown to be histone demethylases, and jmjC is the catalytic domain. However, Jmj does not have histone demethylase activity because the jmjC domain lacks conserved residues for binding to cofactors. Independently of these studies, we previously showed that Jmj binds to the cyclin D1 promoter and represses the transcription of cyclin D1. Here, we show the mechanisms by which Jmj represses the transcription of cyclin D1. We found that a protein complex of Jmj had histone methyltransferase activity toward histone H3 lysine 9 (H3-K9). We also found that Jmj bound to the H3-K9 methyltransferases G9a and GLP. Expression of Jmj recruited G9a and GLP to the cyclin D1 promoter and increased H3-K9 methylation. Inactivation of both G9a and GLP, but not of only G9a, inhibited the methylation of H3-K9 in the cyclin D1 promoter and repression of cyclin D1 expression by Jmj. These results suggest that Jmj methylates H3-K9 and represses cyclin D1 expression through G9a and GLP, and that Jmj family proteins can regulate gene expression by not only histone demethylation but also other histone modification.


Cyclin D1/metabolism , Histones/metabolism , Nerve Tissue Proteins/metabolism , Amino Acid Sequence , Animals , Cell Line , Cyclin D1/genetics , Gene Expression Regulation , Histone Methyltransferases , Histone-Lysine N-Methyltransferase , Histones/chemistry , Histones/genetics , Humans , Methylation , Mice , Molecular Sequence Data , Nerve Tissue Proteins/genetics , Promoter Regions, Genetic/genetics , Protein Binding , Protein Methyltransferases/genetics , Protein Methyltransferases/metabolism
12.
Mech Dev ; 120(7): 791-800, 2003 Jul.
Article En | MEDLINE | ID: mdl-12915229

Homozygous jumonji (jmj(-)/jmj(-)) mice were previously shown to exhibit hepatic hypoplasia and defective hematopoiesis in the liver and die at around embryonic day 15.5 (E15.5), suggesting that jmj is essential for liver development. In order to gain insight into the mechanism of liver development, we analyzed the expression and function of jmj in fetal hepatocytes. The number of hepatocytes in jmj(-)/jmj(-) mice was markedly reduced in comparison with control mice and the expression of jmj in hepatocytes increased along with development. As jmj(-)/jmj(-) embryos die by E15.5, we employed an in vitro culture system in which fetal hepatocytes differentiate in response to oncostatin M. The proliferation potential of jmj(-)/jmj(-) hepatocytes was comparable to that of wild type cells in vitro, however maturation of hepatocytes as evidenced by the expression of liver enzymes such as tyrosine amino transferase was severely impaired by the jmj gene inactivation. These results suggested that jmj plays a pivotal role in the development of mid-fetal hepatocytes to the neonatal stage.


Cell Differentiation/physiology , Fetus/physiology , Hepatocytes/physiology , Nerve Tissue Proteins/genetics , Animals , Mice , Nerve Tissue Proteins/physiology , Polycomb Repressive Complex 2
13.
J Biol Chem ; 278(46): 45611-9, 2003 Nov 14.
Article En | MEDLINE | ID: mdl-12925532

It is thought that the nuclear nonchromatin structures, such as the nuclear matrix and lamina, play regulatory roles in gene expression. In this study, we identified an insoluble protein that was associated with the chromatin-depleted nuclear structure of proliferating human leukemia HL-60 cells. Preparation of the chromatin-depleted nuclear structure, referred to as the nuclear matrix-intermediate filament scaffold (Fey, E., Krochmalnic, G., and Penman, S. (1986) J. Cell. Biol. 102, 1654-1665), involved cell extraction using a series of buffers containing Triton X-100, DNase I, and 2 M NaCl. A yeast two-hybrid assay revealed that this protein bound to the catalytic subunit of protein phosphatase-1 (PP1). Furthermore, it inhibited PP1 activity in vitro. We therefore named it scapinin (scaffold-associated PP1 inhibiting protein). cDNA cloning revealed that scapinin had two splicing variants of 448 amino acids (scapinin-S) and 518 amino acids (scapinin-L). Scapinin was down-regulated by differentiation in HL-60 cells. These results suggest that scapinin is a putative regulatory subunit of PP1 and is involved in transformed or immature phenotypes of HL-60 cells. We also describe the presence of scapinin family proteins from worm to human.


Cell Nucleus/metabolism , Nuclear Proteins/chemistry , Nuclear Proteins/physiology , Phosphoprotein Phosphatases/chemistry , Amino Acid Sequence , Animals , Antibodies, Monoclonal , Blotting, Northern , Buffers , Caenorhabditis elegans , Cell Differentiation , Cell Line , Chromatin/metabolism , Cloning, Molecular , DNA, Complementary/metabolism , Detergents/pharmacology , Dose-Response Relationship, Drug , Down-Regulation , Drosophila melanogaster , Expressed Sequence Tags , Green Fluorescent Proteins , HL-60 Cells , Histones , Humans , Luminescent Proteins/metabolism , Microscopy, Fluorescence , Molecular Sequence Data , Phosphoprotein Phosphatases/metabolism , Precipitin Tests , Protein Binding , Protein Phosphatase 1 , Protein Structure, Tertiary , Ribonuclease, Pancreatic/metabolism , Sequence Homology, Amino Acid , Tissue Distribution , Two-Hybrid System Techniques
14.
Dev Cell ; 5(1): 85-97, 2003 Jul.
Article En | MEDLINE | ID: mdl-12852854

Spatiotemporal regulation of cell proliferation is necessary for normal tissue development. The molecular mechanisms, especially the signaling pathways controlling the cell cycle machinery, remain largely unknown. Here, we demonstrate a negative relationship between the spatiotemporal patterns of jumonji (jmj) expression and cardiac myocyte proliferation. cyclin D1 expression and cell proliferation are enhanced in the cardiac myocytes of jmj-deficient mutant embryos. In contrast, jmj overexpression represses cyclin D1 expression in cardiac cells, and Jmj protein binds to cyclin D1 promoter in vivo and represses its transcriptional activity. cyclin D1 overexpression causes hyperproliferation in the cardiac myocytes, but the absence of cyclin D1 in jmj mutant embryos rescues the hyperproliferation. Therefore, Jmj might control cardiac myocyte proliferation and consequently cardiac morphogenesis by repressing cyclin D1 expression.


Cell Division/genetics , Cyclin D1/metabolism , Nerve Tissue Proteins/metabolism , Animals , Cell Division/drug effects , Crosses, Genetic , Cyclin D1/genetics , Gene Expression Regulation , Heart/embryology , Mice , Mice, Inbred C3H , Mice, Transgenic , Models, Biological , Mutation , Myocardium/cytology , Nerve Tissue Proteins/genetics , Nerve Tissue Proteins/pharmacology , Polycomb Repressive Complex 2 , Promoter Regions, Genetic , Transcription, Genetic
...