Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 17 de 17
1.
J Inflamm Res ; 17: 581-589, 2024.
Article En | MEDLINE | ID: mdl-38318245

Purpose: Infection is the most common complication after left ventricular assist device (LVAD) implantation. The immune status of LVAD patients is relevant for the incidence and severity of infection, but it is unknown if there is a predisposing immune status prior to LVAD implantation that contributes to an increased risk for infection in the post-implant period. We analyzed the pre-LVAD immune status in patients with infection within 3 months after LVAD implantation in comparison to infection-free patients. Patients and Methods: Fifty-four consecutive LVAD patients were included in this study. According to their infectious history in the first 3 months after LVAD implantation, these patients were grouped into an infection (n=23) and an infection-free group (n=31). Pre-LVAD blood samples were obtained for flow cytometric analysis of immunological parameters including B cells, subsets of T, dendritic and natural killer cells. Patient-specific, clinical and laboratory data were recorded. Results: Blood count analysis prior to LVAD implantation showed comparable counts of erythrocytes (p=0.19), platelets (p=0.33) and leukocytes (p=0.50) between patients with infection and infection-free patients in the post-implant period. Patients with infection in the first 3 months after LVAD implantation had lower concentrations of lymphocytes (p=0.02). Forty percent of the patients with infection showed more often pre-LVAD neutrophil-to-lymphocyte ratios (NLR) >7 than patients without infection in the first 3 months after LVAD implantation (14%, p=0.05). Patients with infection already had lower percentages of CD3+ T cells (p=0.03), CD19+ B cells (p<0.01), BDCA2+ pDCs (p=0.03) and BDCA4+ plasmacytoid DCs (pDCs) (p=0.05) prior to LVAD implantation than infection-free patients. Conclusion: Our results demonstrated that patients with infection in the early post-implant period showed lower concentrations of lymphocytes, especially of CD3+ T cells and CD19+ B cells, decreased percentages of BDCA2+ and BDCA4+ pDCs, and had more often NLRs >7 indicating moderate-to-severe inflammation. Thus, we identified specific immunological changes pre-LVAD that could help to identify patients at risk for infection in the early post-implant period.

2.
Int J Cardiovasc Imaging ; 40(2): 213-224, 2024 Feb.
Article En | MEDLINE | ID: mdl-37891450

PURPOSE: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies. METHODS: MVP patients with indication for surgery due to severe mitral regurgitation (n = 19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE). CMR T1 mapping was performed on 21 healthy volunteers as controls. LV inferobasal myocardial biopsies were obtained in MVP patients and compared to CMR findings. RESULTS: MVP patients (54 ± 10 years old, 14 male) had a dark-appearance of the PM with higher native T1 and extracellular volume (ECV) values compared with healthy volunteers (1096 ± 78ms vs. 994 ± 54ms and 33.9 ± 5.6% vs. 25.9 ± 3.1%, respectively, p < 0.001). Seventeen MVP patients (89.5%) had fibrosis by biopsy. BB-LGE + in LV and PM was identified in 5 (26.3%) patients, while DB-LGE + was observed in LV in 9 (47.4%) and in PM in 15 (78.9%) patients. DB-LGE + in PM was the only technique that showed no difference with detection of LV fibrosis by biopsy. Posteromedial PM was more frequently affected than the anterolateral (73.7% vs. 36.8%, p = 0.039) and correlated with biopsy-proven LV fibrosis (Rho 0.529, p = 0.029). CONCLUSIONS: CMR imaging in MVP patients referred for surgery shows a dark-appearance of the PM with higher T1 and ECV values compared with healthy volunteers. The presence of a positive DB-LGE at the posteromedial PM by CMR may serve as a better predictor of biopsy-proven LV inferobasal fibrosis than conventional CMR techniques.


Mitral Valve Prolapse , Humans , Male , Adult , Middle Aged , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/surgery , Papillary Muscles/pathology , Heart Ventricles , Contrast Media , Predictive Value of Tests , Gadolinium , Fibrosis , Magnetic Resonance Imaging, Cine
3.
Front Immunol ; 14: 1256725, 2023.
Article En | MEDLINE | ID: mdl-37885885

Purpose: Infection is a common complication following left ventricular assist device (LVAD) implantation. Patients with obesity are particularly at risk due to their high percentage of adipose tissue and the resulting chronic inflammatory state and resulting immunological changes. This study investigated changes of immunological parameters in relation to body mass index (BMI) during the first year after LVAD implantation. Methods: Blood samples were obtained prior to LVAD implantation and at 3 (1st FU), 6 (2nd FU) and 12 mo (3rd FU) after LVAD implantation. Patients were divided into three groups (normal weight: BMI of 18.5-24.9 kg/m2; n=12; pre-obesity: 25.0-29.9 kg/m2; n=15; obesity: ≥ 30.0 kg/m2; n=17) based on their BMI at the time of LVAD implantation. Flow cytometric analyses for CD4+ and CD8+ T cells, regulatory T cells (Tregs), B cells as well as dendritic cells (DCs) were performed. Results: After LVAD implantation, obese patients (0.51 ± 0.20%) showed a higher proportion of overall DCs than normal-weight (0.28 ± 0.10%) and pre-obese patients (0.32 ± 0.11%, p<0.01) at 3rd FU. The proportion of BDCA3+ myeloid DCs was lower in obese patients (64.3 ± 26.5%) compared to normal-weight patients (82.7 ± 10.0%, pnormal-weight vs. obesity=0.05) at 2nd FU after LVAD implantation. The analysis of BDCA4+ plasmacytoid DCs revealed a reduced proportion in pre-obese (21.1 ± 9.8%, pnormal-weight vs. pre-obesity=0.01) and obese patients (23.7 ± 10.6%, pnormal-weight vs. obesity=0.05) compared to normal-weight patients (33.1 ± 8.2%) in the 1st FU. T cell analysis showed that CD4+ T cells of obese patients (62.4 ± 9.0%) significantly increased in comparison to pre-obese patients (52.7 ± 10.0%, ppre-obesity vs. obesity=0.05) and CD8+ T cells were lower in obese patients (31.8 ± 8.5%) than in normal-weight patients (42.4 ± 14.2%; pnormal-weight vs. obesity=0.04) at the 3rd FU. Furthermore, we observed significantly reduced proportions of Tregs in pre-obese patients compared to normal-weight and obese patients at 2nd FU (p=0.02) and 3rd FU (p=0.01) after LVAD implantation. Conclusion: This study reported changes of the innate and adaptive immune system of pre-obese and obese compared to normal-weight patients one year after LVAD implantation. DCs and their subsets, CD8+ T cells and Tregs were affected immune cell populations that indicate immunological changes which might increase the incidence of postoperative infection.


Heart-Assist Devices , Humans , Body Mass Index , Heart-Assist Devices/adverse effects , CD8-Positive T-Lymphocytes , Retrospective Studies , Obesity/complications
4.
Res Sq ; 2023 May 17.
Article En | MEDLINE | ID: mdl-37292932

Purpose: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies. Methods: MVP patients with indication for surgery due to severe mitral regurgitation (n=19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE). CMR T1 mapping was performed on 21 healthy volunteers as controls. LV inferobasal myocardial biopsies were obtained in MVP patients and compared to CMR findings. Results: MVP patients (54±10 years old, 14 male) had a dark-appearance of the PM with higher native T1 and extracellular volume (ECV) values compared with healthy volunteers (1096±78ms vs 994±54ms and 33.9±5.6% vs 25.9±3.1%, respectively, p<0.001). Seventeen MVP patients (89.5%) had fibrosis by biopsy. BB-LGE+ in LV and PM was identified in 5 (26.3%) patients, while DB-LGE+ was observed in LV in 9 (47.4%) and in PM in 15 (78.9%) patients. DB-LGE+ in PM was the only technique that showed no difference with detection of LV fibrosis by biopsy. Posteromedial PM was more frequently affected than the anterolateral (73.7% vs 36.8%, p=0.039) and correlated with biopsy-proven LV fibrosis (Rho 0.529, p=0.029). Conclusions: CMR imaging in MVP patients referred for surgery shows a dark-appearance of the PM with higher T1 and ECV values compared with healthy volunteers. The presence of a positive DB-LGE at the posteromedial PM by CMR may serve as a better predictor of biopsy-proven LV inferobasal fibrosis than conventional CMR techniques.

5.
Obes Facts ; 16(4): 364-373, 2023.
Article En | MEDLINE | ID: mdl-37232004

INTRODUCTION: Infections are a major problem after left ventricular assist device (LVAD) implantation that affects morbidity, mortality, and the quality of life. Obesity often increases the risk for infection. In the cohort of LVAD patients, it is unknown if obesity affects the immunological parameters involved in viral defense. Therefore, this study investigated whether overweight or obesity affects immunological parameters such as CD8+ T cells and natural killer (NK) cells. METHODS: Immune cell subsets of CD8+ T cells and NK cells were compared between normal-weight (BMI 18.5-24.9 kg/m2, n = 17), pre-obese (BMI 25.0-29.9 kg/m2, n = 24), and obese (BMI ≥30 kg/m2, n = 27) patients. Cell subsets and cytokine serum levels were quantified prior to LVAD implantation and at 3, 6, and 12 months after LVAD implantation. RESULTS: At the end of the first postoperative year, obese patients (31.8% ± 2.1%) had a lower proportion of CD8+ T cells than normal-weight patients (42.4% ± 4.1%; p = 0.04), and the percentage of CD8+ T cells was negatively correlated with BMI (p = 0.03; r = -0.329). The proportion of circulating NK cells increased after LVAD implantation patients in normal-weight (p = 0.01) and obese patients (p < 0.01). Patients with pre-obesity showed a delayed increase (p < 0.01) 12 months after LVAD implantation. Further, obese patients showed an increase in the percentage of CD57+ NK cells after 6 and 12 months (p = 0.01) of treatment, higher proportions of CD56bright NK cells (p = 0.01), and lower proportions of CD56dim/neg NK cells (p = 0.03) 3 months after LVAD implantation than normal-weight patients. The proportion of CD56bright NK cells positively correlated with BMI (p < 0.01, r = 0.403) 1 year after LVAD implantation. CONCLUSIONS: This study documented that obesity affects CD8+ T cells and subsets of NK cells in patients with LVAD in the first year after LVAD implantation. Lower proportions of CD8+ T cells and CD56dim/neg NK cells and higher proportion of CD56bright NK cells were detected in obese but not in pre-obese and normal-weight LVAD patients during the first year after LVAD implantation. The induced immunological imbalance and phenotypic changes of T and NK cells may influence viral and bacterial immunoreactivity.


Heart Failure , Quality of Life , Humans , Obesity/complications , Obesity/therapy , Body Mass Index , Retrospective Studies
6.
Int J Mol Sci ; 24(6)2023 Mar 15.
Article En | MEDLINE | ID: mdl-36982712

Non-surgical bleeding (NSB) remains the most critical complication in patients under left ventricular assist device (LVAD) support. It is well known that blood exposed to high shear stress results in platelet dysfunction. Compared to patients without NSB, decreased surface expression of platelet receptor GPIbα was observed in LVAD patients with NSB. In this study, we aimed to compare the expression level of glycoprotein (GP)Ib-IX-V platelet receptor complex in HeartMate 3 (HM 3) patients with and without bleeding complications to investigate the alterations of the platelet transcriptomic profile on platelet damage and increased bleeding risk. Blood samples were obtained from HM 3 patients with NSB (bleeder group, n = 27) and without NSB (non-bleeder group, n = 55). The bleeder group was further divided into patients with early NSB (bleeder ≤ 3 mo, n = 19) and patients with late NSB (bleeder > 3 mo, n = 8). The mRNA and protein expression of GPIbα, GPIX and GPV were quantified for each patient. Non-bleeder, bleeder ≤ 3 mo and bleeder > 3 mo were comparable regarding the mRNA expression of GPIbα, GPIX and GPV (p > 0.05). The protein analysis revealed a significantly reduced expression level of the main receptor subunit GPIbα in bleeders ≤ 3 mo (p = 0.04). We suggest that the observed reduction of platelet receptor GPIbα protein expression in patients who experienced their first bleeding event within 3 months after LVAD implantation may influence platelet physiology. The alterations of functional GPIbα potentially reduce the platelet adhesion capacities, which may lead to an impaired hemostatic process and the elevated propensity of bleeding in HM 3 patients.


Blood Platelets , Platelet Glycoprotein GPIb-IX Complex , Humans , Blood Platelets/metabolism , Cell Membrane/metabolism , Platelet Glycoprotein GPIb-IX Complex/genetics , Platelet Glycoprotein GPIb-IX Complex/metabolism , Hemorrhage/genetics , Platelet Adhesiveness , RNA, Messenger/metabolism
7.
Int J Mol Sci ; 23(18)2022 Sep 06.
Article En | MEDLINE | ID: mdl-36142161

Non-surgical bleeding (NSB) is one of the major clinical complications in patients under continuous-flow left ventricular assist device (LVAD) support. The increased shear stress leads to an altered platelet receptor composition. Whether these changes increase the risk for NSB is unclear. Thus, we compared the platelet receptor composition of patients with (bleeder group, n = 18) and without NSB (non-bleeder group, n = 18) prior to LVAD implantation. Blood samples were obtained prior to LVAD implantation and after bleeding complications in the post-implant period. Platelet receptor expression of GPIbα, GPIIb/IIIa, P-selectin and CD63 as well as intra-platelet oxidative stress levels were quantified by flow cytometry. Bleeders and non-bleeders were comparable regarding clinical characteristics, von Willebrand factor diagnostics and the aggregation capacity before and after LVAD implantation (p > 0.05). LVAD patients in the bleeder group suffered from gastrointestinal bleeding (33%; n = 6), epistaxis (22%; n = 4), hematuria or hematoma (17%; n = 3, respectively) and cerebral bleeding (11%; n = 2). Prior to LVAD implantation, a restricted surface expression of the platelet receptors P-selectin and GPIIb/IIIa was observed in the bleeder group (P-selectin: 7.2 ± 2.6%; GPIIb/IIIa: 26,900 ± 13,608 U) compared to non-bleeders (P-selectin: 12.4 ± 8.1%, p = 0.02; GPIIb/IIIa: 36,259 ± 9914 U; p = 0.02). We hypothesized that the reduced platelet receptor expression of P-selectin and GPIIb/IIIa prior to LVAD implantation may be linked to LVAD-related NSB.


Heart Failure , Heart-Assist Devices , Blood Platelets/metabolism , Heart Failure/metabolism , Heart-Assist Devices/adverse effects , Hemorrhage , Humans , P-Selectin/metabolism , Platelet Glycoprotein GPIIb-IIIa Complex/metabolism , von Willebrand Factor/metabolism
8.
J Pers Med ; 12(5)2022 May 23.
Article En | MEDLINE | ID: mdl-35629271

BACKGROUND: Gender-specific differences in the outcome of COVID-19 patients requiring intensive care treatment have been reported. However, a potential association with ICU therapy remains elusive. METHODS: A total of 224 consecutive patients (63 women) treated for severe COVID-19 disease requiring mechanical ventilation were screened for the study. After propensity score matching for gender, 40 men and 40 women were included in the study. Comparative analysis was conducted for laboratory parameters, ICU therapy and complications (pulmonary embolism, thrombosis, stroke, and ventricular arrhythmias), and outcome (mortality). RESULTS: Male patients had significantly higher levels of CRP (p = 0.012), interleukin-6 (p = 0.020) and creatinine (p = 0.027), while pH levels (p = 0.014) were significantly lower compared to females. Male patients had longer intubation times (p = 0.017), longer ICU stays (p = 0.022) and higher rates of catecholamine dependence (p = 0.037). Outcome, complications and ICU therapy did not differ significantly between both groups. CONCLUSION: The present study represents the first matched comparison of male and female COVID-19 patients requiring intensive care treatment. After propensity matching, male patients still displayed a higher disease severity. This was reflected in higher rates of vasopressors, duration of ICU stay and duration of intubation. In contrast, no significant differences were observed in mortality rates, organ replacement therapy and complications during ICU stay.

9.
Thorac Cardiovasc Surg ; 70(2): 100-105, 2022 Mar.
Article En | MEDLINE | ID: mdl-33601467

BACKGROUND: Mitral valve (MV) repair with annuloplasty is the standard of care in patients with primary degenerative mitral regurgitation (DMR). Newer generations of annuloplasty rings have been developed with the goals of closer reproduction of native annular geometry and easier implantation. This study investigates the short-term and 5-year clinical outcomes of MV repair with the Carpentier-Edwards (CE) Physio II annuloplasty ring. METHODS: This is an observational study including a total of 486 patients who underwent MV repair for DMR using the CE Physio II annuloplasty ring between 2011 and 2016. RESULTS: Mean age was 54.8 ± 12.1 years, 364 patients (74.9%) were males, and 84 patients (17.3%) presented with atrial fibrillation. Mean left ventricular ejection fraction was 62.3 ± 7.3%. Mean logistic EuroSCORE was 2.7 ± 2.4%. New York Heart Association functional class III-IV symptoms were present in 134 (27.6%) patients preoperatively. Isolated MV repair was performed via a right-sided mini-thoracotomy in 479 patients (98.6%). Concomitant procedures included ablation for atrial fibrillation in 83 patients (17.1%) and closure of atrial septum defect in 88 patients (18.1%). Median size of implanted annuloplasty rings was 34 mm (interquartile range: 34-38 mm). Mean cardiopulmonary bypass time was 116 ± 34 minutes and mean cross-clamp time was 74 ± 25 minutes. Thirty-day mortality was 0.4%. The Kaplan-Meier 4-year survival was 98.5%. Freedom from MV reoperation was 96.2 and 94.0% at 1 and 4 years. CONCLUSION: MV repair with the CE Physio II annuloplasty ring is associated with excellent midterm clinical outcome.


Heart Valve Prosthesis Implantation , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Adult , Aged , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Stroke Volume , Treatment Outcome , Ventricular Function, Left
10.
Artif Organs ; 46(1): 106-116, 2022 Jan.
Article En | MEDLINE | ID: mdl-34398476

The resolution of functional mitral valve regurgitation (MR) in patients awaiting left ventricular assist device (LVAD) implantation is discussed controversially. The present study analyzed MR and echocardiographic parameters of the third-generation LVAD HeartMate 3 (HM3) over 3 years. Of 135 LVAD patients (with severe MR, n = 33; with none, mild, or moderate MR, n = 102), data of transthoracic echocardiography were included preoperatively to LVAD implantation, up to 1 month postoperatively, and at 1, 2, and 3 years after LVAD implantation. Demographic data and clinical characteristics were collected. Severe MR was reduced immediately after LVAD implantation in all patients. The echocardiographic parameters left ventricular end-diastolic diameter (P < .001), right ventricular end-diastolic diameter (P < .001), tricuspid annular plane systolic excursion (P < .001), and estimated pulmonary artery pressure (P < .001) decreased after HM3 implantation independently from the grade of MR prior to implantation and remained low during the 2 years follow-up period. Following LVAD implantation, right heart failure, ventricular arrhythmias, ischemic stroke as well as pump thrombosis and bleeding events were comparable between the groups. The incidences of death and cardiac death did not differ between the patient groups. Furthermore, the Kaplan-Meier analysis showed that survival was comparable between the groups (P = .073). HM3 implantation decreases preoperative severe MR immediately after LVAD implantation. This effect is long-lasting in most patients and reinforces the LVAD implantation without MR surgery. The complication rates and survival were comparable between patients with and without severe MR.


Heart Failure/therapy , Heart-Assist Devices , Mitral Valve Insufficiency/physiopathology , Adult , Echocardiography , Female , Heart Failure/mortality , Heart Failure/pathology , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Mitral Valve Insufficiency/diagnostic imaging , Prosthesis Implantation , Treatment Outcome , Ventricular Dysfunction, Left/therapy
11.
J Am Heart Assoc ; 10(24): e022332, 2021 12 21.
Article En | MEDLINE | ID: mdl-34873924

Background Mitral valve prolapse (MVP) is one of the most common forms of cardiac valve disease and affects 2% to 3% of the population. Previous imaging reports have indicated that myocardial fibrosis is common in MVP and described its association with sudden cardiac death. These data combined with evidence for postrepair ventricular dysfunction in surgical patients with MVP support a link between fibrosis and MVP. Methods and Results We performed histopathologic analysis of left ventricular (LV) biopsies from peripapillary regions, inferobasal LV wall and apex on surgical patients with MVP, as well as in a mouse model of human MVP (Dzip1S14R/+). Tension-dependent molecular pathways were subsequently assessed using both computational modeling and cyclical stretch of primary human cardiac fibroblasts in vitro. Histopathology of LV biopsies revealed regionalized fibrosis in the peripapillary myocardium that correlated with increased macrophages and myofibroblasts. The MVP mouse model exhibited similar regional increases in collagen deposition that progress over time. As observed in the patient biopsies, increased macrophages and myofibroblasts were observed in fibrotic areas within the murine heart. Computational modeling revealed tension-dependent profibrotic cellular and molecular responses consistent with fibrosis locations related to valve-induced stress. These simulations also identified mechanosensing primary cilia as involved in profibrotic pathways, which was validated in vitro and in human biopsies. Finally, in vitro stretching of primary human cardiac fibroblasts showed that stretch directly activates profibrotic pathways and increases extracellular matrix protein production. Conclusions The presence of prominent regional LV fibrosis in patients and mice with MVP supports a relationship between MVP and progressive damaging effects on LV structure before overt alterations in cardiac function. The regionalized molecular and cellular changes suggest a reactive response of the papillary and inferobasal myocardium to increased chordal tension from a prolapsing valve. These studies raise the question whether surgical intervention on patients with MVP should occur earlier than indicated by current guidelines to prevent advanced LV fibrosis and potentially reduce residual risk of LV dysfunction and sudden cardiac death.


Cardiomyopathies , Mitral Valve Prolapse , Animals , Cardiomyopathies/etiology , Cardiomyopathies/pathology , Fibrosis , Humans , Mice , Mitral Valve Prolapse/complications
12.
J Cardiovasc Magn Reson ; 23(1): 87, 2021 07 08.
Article En | MEDLINE | ID: mdl-34233708

BACKGROUND: Four-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE). METHODS: Six healthy subjects and 54 patients (55 ± 16 years; 47 men) with MVP were studied. TTE severity grading used a multiparametric approach resulting in mild/mild-moderate (n = 12), moderate-severe (n = 12), and severe MR (n = 30). Regurgitant volume (RVol) and regurgitant fraction (RF) were also derived using standard volumetric CMR and 4D flow CMR datasets with direct measurement of regurgitant flow (4DFdirect) and indirect calculation using the formula: mitral valve forward flow - left ventricular outflow tract stroke volume (4DFindirect). RESULTS: There was moderate to strong correlation between methods (r = 0.59-0.84, p < 0.001), but TTE proximal isovelocity surface area (PISA) method showed higher RVol as compared with CMR techniques (PISA vs. CMR, mean difference of 15.8 ml [95% CI 9.9-21.6]; PISA vs. 4DFindirect, 17.2 ml [8.4-25.9]; PISA vs. 4DFdirect, 27.9 ml [19.1-36.8]; p < 0.001). Only indirect CMR methods (CMR vs. 4DFindirect) showed moderate to substantial agreement (Lin's coefficient 0.92-0.97) without significant bias (mean bias 1.05 ± 26 ml [- 50 to 52], p = 0.757). Intra- and inter-observer reliability were good to excellent for all methods (ICC 0.87-0.99), but with numerically lower coefficient of variation for indirect CMR methods (2.5 to 12%). CONCLUSIONS: In the assessment of patients with MR and MVP, cine-guided valve segmentation 4D flow CMR is feasible and comparable to standard CMR, but with lower RVol when TTE is used as reference. 4DFindirect quantification has higher intra- and inter-technique agreement than 4DFdirect quantification and might be used as an adjunctive technique for cross-checking MR quantification in MVP.


Mitral Valve Insufficiency , Mitral Valve Prolapse , Humans , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Male , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Prolapse/diagnostic imaging , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Severity of Illness Index
13.
Int J Cardiovasc Imaging ; 37(6): 1947-1959, 2021 Jun.
Article En | MEDLINE | ID: mdl-33616785

Three-dimensional transthoracic echocardiography (3D-TTE) provides a semi-automated proximal isovelocity surface area method (3D-PISA) to obtain quantitative parameters. Data assessing regurgitation severity in mitral valve prolapse (MVP) are scarce, so we assessed the 3D-PISA method compared with 2D-PISA and cardiovascular magnetic resonance (CMR) and the role of an eccentricity index. We evaluated the 3D-PISA method for assessing MR in 54 patients with MVP (57 ± 14 years; 42 men; 12 mild/mild-moderate; 12 moderate-severe; and 30 severe MR). Role of an asymmetric (i.e. eccentricity index ≥ 1.25) flow convergence region (FCR) and inter-modality consistency were then assessed. 3D-PISA derived regurgitant volume (RVol) showed a good correlation with 2D-PISA and CMR derived parameters (r = 0.86 and r = 0.81, respectively). The small mean differences with 2D-PISA derived RVol did not reach statistical significance in overall population (5.7 ± 23 ml, 95% CI - 0.6 to 12; p = 0.08) but differed in those with asymmetric 3D-FCR (n = 21; 2D-PISA: 72 ± 36 ml vs. 3D-PISA: 93 ± 47 ml; p = 0.001). RVol mean values were higher using PISA methods (CMR 57 ± 33 ml; 2D-PISA 73 ± 39 ml; and 3D-PISA 79 ± 45 ml) and an overestimation was observed when CMR was used as reference (2D-PISA vs. CMR: mean difference: 15.8 ml [95% CI 10-22, p < 0.001]; and 3D-PISA vs. CMR: 21.5 ml [95% CI 14-29, p < 0.001]). Intra- and inter-observer reliability was excellent (ICC 0.91-0.99), but with numerically lower coefficient of variation for 3D-PISA (8%-10% vs. 2D-PISA: 12%-16%). 3D-PISA method for assessing regurgitation in MVP may enable analogous evaluation compared to standard 2D-PISA, but with overestimation in case of asymmetric FCR or when CMR is used as reference method.


Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Mitral Valve Prolapse , Echocardiography, Doppler, Color , Humans , Male , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Prolapse/diagnostic imaging , Predictive Value of Tests , Reproducibility of Results , Severity of Illness Index
14.
J Thromb Haemost ; 19(5): 1331-1341, 2021 05.
Article En | MEDLINE | ID: mdl-33636040

BACKGROUND: Non-surgical bleeding (NSB) is a major complication after left ventricular assist device (LVAD) implantation. It has been reported that non-physiological shear stress caused by LVADs could alter platelet receptor expression, which leads to bleeding disorders caused by coagulation dysfunctions. OBJECTIVES: Because bleeding diathesis could be multifactorial, we focused on the combined characterization of platelet receptor expression patterns and oxidative stress to compare patients with NSB and patients without coagulation disorder in a monocentric, prospective study. METHODS: Blood samples were obtained from LVAD patients with NSB (bleeder group, n = 19) and without NSB (non-bleeder group, n = 20). The platelet receptors platelet endothelial cell adhesion molecule-1 (PECAM-1), glycoprotein (GP)Ibα, P-selectin, CD63, and GPIIb/IIIa, as well as the production of intraplatelet reactive oxygen species (ROS) were quantified by flow cytometry. Aggregation capacity was evaluated by aggregometry. RESULTS: The surface expression level of P-selectin and GPIbα on platelets was decreased in bleeders (P-selectin: 465 ± 72 U; GPIbα: 435 ± 41 U) compared to non-bleeders (P-selectin: 859 ± 115 U, P < .01; GPIbα: 570 ± 49 U, p = .04). Additionally, the mean fluorescence intensity of ADP-stimulated P-selectin and PECAM-1 expressing platelets were reduced in bleeders (P-selectin: 944 ± 84 U; PECAM-1: 6722 ± 419 U) compared to non-bleeders (P-selectin: 1269 ± 130 U, P = .04; PECAM-1: 8542 ± 665 U, P = .03). Bleeders showed a higher amount of ROS formation in platelets (88.0 ± 2.6%) than non-bleeders (81.5 ± 2.1%, P = .05). CONCLUSIONS: These findings suggested that changes of three platelet receptors (GPIbα, P-selectin, and PECAM-1) and elevated oxidative stress may play a role in patients with bleeding complications following LVAD implantation. These results might help to explain the high incidence of spontaneous hemorrhage during LVAD support through an altered platelet function.


Blood Platelets/pathology , Heart-Assist Devices , Heart-Assist Devices/adverse effects , Hemorrhage , Humans , P-Selectin , Platelet Endothelial Cell Adhesion Molecule-1 , Platelet Function Tests , Platelet Glycoprotein GPIb-IX Complex , Prospective Studies
15.
J Cardiol ; 76(2): 154-162, 2020 08.
Article En | MEDLINE | ID: mdl-32273155

OBJECTIVES: The prognostic value of biomarkers in aortic stenosis (AS) remains understudied. We investigated whether a combination of biomarkers related to cardiovascular stress, inflammation, and damage is associated with mortality in patients with severe AS undergoing surgical aortic valve replacement (SAVR). METHODS: From a prospective registry of patients with severe AS referred for SAVR, 499 participants (mean age, 68 ± 8.5 years; 292 male) with available preoperative echocardiograms and biomarker data were included. Preoperative concentrations of NT-pro-B-type natriuretic peptide, high-sensitivity cardiac troponin T, and C-reactive protein were dichotomized as high or low, according to calculated cut-off values. RESULTS: The mean follow-up time was 775 ± 410 days; 25 patients died. Only patients with elevated levels of all three biomarkers (n = 55) showed increased mortality [hazard ratio (HR), 7.26; 95% confidence interval (CI), 2.52-20.93; p < 0.001; reference group, no elevated biomarkers, n = 159]. Patients with elevated levels of the three biomarkers had higher 3-year all-cause mortality (24% vs. 4.5%); this remained true after multivariable adjustment (HR, 4.08; 95% CI, 1.87-8.87; p < 0.001). Patients with EuroSCOREs (logES) >3.0% tended to exhibit a higher risk of all-cause mortality (HR, 2.19; 95% CI, 0.98-4.87; p = 0.055); the mortality rate was 12-fold higher when logES >3 was combined with the three elevated biomarkers. This combination also showed a net reclassification improvement of 33% and significant likelihood-ratio test results. CONCLUSIONS: A multiple biomarker approach might be useful for predicting postoperative mid-term mortality in patients with severe AS undergoing SAVR. Further large-scale prospective validation should be performed.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/blood , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Biomarkers/blood , C-Reactive Protein/analysis , Female , Humans , Male , Middle Aged , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Registries , Risk Factors , Severity of Illness Index , Treatment Outcome , Troponin T/blood
16.
Eur J Cardiothorac Surg ; 57(2): 300-307, 2020 02 01.
Article En | MEDLINE | ID: mdl-31369069

OBJECTIVES: Mitral valve (MV) annuloplasty ring dehiscence with subsequent recurrent mitral regurgitation represents an unusual but challenging clinical problem. Incidence, localization and outcomes for this complication have not been well defined. METHODS: From 1996 to 2016, a total of 3478 patients underwent isolated MV repair with ring annuloplasty at the Leipzig Heart Centre. Of these patients, 57 (1.6%) underwent reoperation due to annuloplasty ring dehiscence. Echocardiographic data, operative and early postoperative characteristics as well as short- and long-term survival rates after MV reoperation were analysed. RESULTS: Occurrences of ring dehiscence were acute (<30 days), early (≤1 year) and late (>1 year) in 44%, 33% and 23% of patients, respectively. Localization of annuloplasty ring dehiscence was found most frequently in the P3 segment (68%), followed by the P2 (51%) and the P1 segments (47%). The 30-day mortality rate and 1- and 5-year survival rates after MV reoperation were 2%, 89% and 74%, respectively. During reoperation, MV replacement was performed in 38 (67%) and MV re-repair in 19 (33%) patients. CONCLUSIONS: Annuloplasty ring dehiscence is clinically less common, localized more frequently on the posterior annulus and occurs mostly acutely or early after MV repair. MV reoperation can be performed safely in such patients.


Heart Valve Prosthesis Implantation , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Heart Valve Prosthesis Implantation/adverse effects , Humans , Incidence , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Reoperation , Treatment Outcome
17.
Eur J Cardiothorac Surg ; 56(5): 983-992, 2019 Nov 01.
Article En | MEDLINE | ID: mdl-30932164

OBJECTIVES: The goal of this study was to quantify the mitral valve (MV) annulus, the MV shape and the anatomical MV orifice area throughout the cardiac cycle using 4-dimensional MV analysis software in patients with primary mitral regurgitation (PMR) and secondary mitral regurgitation (SMR) in comparison to a healthy control group. METHODS: Three-dimensional transoesophageal echocardiograms of the MV were acquired for 29 patients with PMR, for 28 patients with SMR and for 18 healthy control subjects. The MV was quantified with regards to anterior-posterior and lateromedial diameter, annular area and circumference, intertrigonal (IT) distance, annular sphericity index, annular height to commissural width ration, and anatomical MV orifice area throughout the cardiac cycle using 3-dimensional transoesophageal echocardiography-based 4-dimensional MV advanced analysis software. RESULTS: Normal annulus dynamics display a systolic enlargement followed by an early-diastolic plateau phase and a late-diastolic contraction. The IT distance showed a linear association with the anterior-posterior diameter (= 1.11 × IT distance) and lateromedial diameter (= 1.44 × IT distance) in the control subjects. Mitral regurgitation is associated with a less dynamic, planar and dilated annulus with small variations between PMR and SMR. The IT distance was less affected by mitral regurgitation compared to the control subjects. CONCLUSIONS: The novel 4-dimensional MV analysis allows new insights into the dynamic MV geometry in patients with PMR and SMR compared to the control subjects. The IT distance may be used to predict annuloplasty ring sizing.


Echocardiography, Three-Dimensional/methods , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency , Mitral Valve , Adult , Aged , Aged, 80 and over , Diastole/physiology , Echocardiography, Transesophageal , Female , Heart Valve Prosthesis , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/pathology , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/pathology , Mitral Valve Insufficiency/surgery , Prospective Studies , Software , Systole/physiology
...