Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
World J Hepatol ; 6(1): 1-8, 2014 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-24653789

RESUMEN

Ischemia-reperfusion plays a major role in the injury experienced by the liver during transplantation. Much work has been done recently investigating the role of redox species in hepatic ischemia-reperfusion. As animal models are better characterized and developed, and more insights are gained into the pathophysiology of hepatic ischemia reperfusion injury in humans the questions into exactly how oxidants participate in this injury are becoming more refined. These questions include effects of cellular location, timing of injury, and ability of therapeutics to access this site are increasing our appreciation of the complexity of ischemia reperfusion and improving attempts to ameliorate its effects. In this review, we aim to discuss the various methods to alter redox chemistry during ischemia reperfusion injury and future prospects for preventing organ injury during hepatic ischemia reperfusion.

2.
PLoS One ; 9(2): e86053, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24533048

RESUMEN

Decreases in endothelial nitric oxide synthase derived nitric oxide (NO) production during liver transplantation promotes injury. We hypothesized that preemptive inhaled NO (iNO) would improve allograft function (primary) and reduce complications post-transplantation (secondary). Patients at two university centers (Center A and B) were randomized to receive placebo (n = 20/center) or iNO (80 ppm, n = 20/center) during the operative phase of liver transplantation. Data were analyzed at set intervals for up to 9-months post-transplantation and compared between groups. Patient characteristics and outcomes were examined with the Mann-Whitney U test, Student t-test, logistic regression, repeated measures ANOVA, and Cox proportional hazards models. Combined and site stratified analyses were performed. MELD scores were significantly higher at Center B (22.5 vs. 19.5, p<0.0001), surgical times were greater at Center B (7.7 vs. 4.5 hrs, p<0.001) and warm ischemia times were greater at Center B (95.4 vs. 69.7 min, p<0.0001). No adverse metabolic or hematologic effects from iNO occurred. iNO enhanced allograft function indexed by liver function tests (Center B, p<0.05; and p<0.03 for ALT with center data combined) and reduced complications at 9-months (Center A and B, p = 0.0062, OR = 0.15, 95% CI (0.04, 0.59)). ICU (p = 0.47) and hospital length of stay (p = 0.49) were not decreased. iNO increased concentrations of nitrate (p<0.001), nitrite (p<0.001) and nitrosylhemoglobin (p<0.001), with nitrite being postulated as a protective mechanism. Mean costs of iNO were $1,020 per transplant. iNO was safe and improved allograft function at one center and trended toward improving allograft function at the other. ClinicalTrials.gov with registry number 00582010 and the following URL:http://clinicaltrials.gov/show/NCT00582010.


Asunto(s)
Antiinflamatorios/administración & dosificación , Fallo Hepático/cirugía , Trasplante de Hígado/métodos , Óxido Nítrico/administración & dosificación , Adulto , Anciano , Aloinjertos , Análisis de Varianza , Estudios de Cohortes , Transfusión de Eritrocitos , Femenino , Costos de la Atención en Salud , Humanos , Inflamación/tratamiento farmacológico , Unidades de Cuidados Intensivos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Óxido Nítrico/economía , Transfusión de Plaquetas , Modelos de Riesgos Proporcionales , Resultado del Tratamiento
3.
J Clin Invest ; 117(9): 2583-91, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17717604

RESUMEN

Ischemia/reperfusion (IR) injury in transplanted livers contributes to organ dysfunction and failure and is characterized in part by loss of NO bioavailability. Inhalation of NO is nontoxic and at high concentrations (80 ppm) inhibits IR injury in extrapulmonary tissues. In this prospective, blinded, placebo-controlled study, we evaluated the hypothesis that administration of inhaled NO (iNO; 80 ppm) to patients undergoing orthotopic liver transplantation inhibits hepatic IR injury, resulting in improved liver function. Patients were randomized to receive either placebo or iNO (n = 10 per group) during the operative period only. When results were adjusted for cold ischemia time and sex, iNO significantly decreased hospital length of stay, and evaluation of serum transaminases (alanine transaminase, aspartate aminotransferase) and coagulation times (prothrombin time, partial thromboplastin time) indicated that iNO improved the rate at which liver function was restored after transplantation. iNO did not significantly affect changes in inflammatory markers in liver tissue 1 hour after reperfusion but significantly lowered hepatocyte apoptosis. Evaluation of circulating NO metabolites indicated that the most likely candidate transducer of extrapulmonary effects of iNO was nitrite. In summary, this study supports the clinical use of iNO as an extrapulmonary therapeutic to improve organ function following transplantation.


Asunto(s)
Trasplante de Hígado , Hígado/efectos de los fármacos , Hígado/fisiología , Óxido Nítrico/administración & dosificación , Óxido Nítrico/farmacología , Daño por Reperfusión/tratamiento farmacológico , Daño por Reperfusión/fisiopatología , Administración por Inhalación , Adulto , Anciano , Muerte Celular , Femenino , Humanos , Tiempo de Internación , Hígado/citología , Masculino , Persona de Mediana Edad , Óxido Nítrico/uso terapéutico , Especies Reactivas de Oxígeno/metabolismo , Daño por Reperfusión/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...