Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Analyst ; 137(19): 4524-30, 2012 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-22890238

RESUMEN

Atmospheric pressure Solids Analysis Probe (ASAP) mass spectrometry has facilitated the ionisation of oligomers from low molecular weight synthetic polymers, poly(ethylene glycol) (PEG: M(n) = 1430) and poly(styrene) (PS: M(n) = 1770), directly from solids, providing a fast and efficient method of identification. Ion source conditions were evaluated and it was found that the key instrument parameter was the ion source desolvation temperature which, when set to 600 °C was sufficient to vapourise the heavier oligomers for ionisation. PS, a non-polar polymer that is very challenging to analyse by MALDI or ESI without the aid of metal salts to promote cationisation, was ionised promptly by ASAP resulting in the production of radical cations. A small degree of in-source dissociation could be eliminated by control of the instrument ion source voltages. The fragmentation observed through in-source dissociation could be duplicated in a controlled manner through Collision-Induced Dissociation (CID) of the radical cations. PEG, which preferentially ionises through adduction with alkali metal cations in MALDI and ESI, was observed as a protonated molecular ion by ASAP. In-source dissociation could not be eliminated entirely and the fragmentation observed resulted from cleavage of the C-C and C-O backbone bonds, as opposed to only C-O bond cleavage observed from tandem mass spectrometry.

2.
J Am Soc Mass Spectrom ; 23(5): 850-7, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22290485

RESUMEN

LC ESI FTICR MS of a sample of cediranib identified this pharmaceutical target molecule plus an additional 10 compounds of interest, all of which were less than 10% total ion current (TIC) peak intensity relative to cediranib. LC FTICR tandem mass spectrometry using electron induced dissociation (EID) has been achieved and has proven to be the best way to generate useful product ion information for all of these singly protonated molecules. Cediranib [M + H](+) fragmented by EID to give 29 product ions whereas QTOF-CID generated only one very intense product ion, and linear ion trap-CID, which generated 10 product ions, but all with poor S/N. Twenty-six of the EID product ions were unique to this fragmentation technique alone. By considering the complementary LC-EID and LC-CID data together, all 10 unknown compounds were structurally characterized and proven to be analogous to cediranib. Of particular importance, EID produced unique product ion information for one of the low level cediranib analogues that enabled full characterization of the molecule such that the presence of an extra propylpyrrolidine group was discovered and proven to be located on the pyrrolidine ring of cediranib, solving an analytical problem that could not be solved by collision induced dissociation (CID). Thus, it has been demonstrated that EID is in harmony with the chromatography duty-cycle and the dynamic concentration range of synthetic compounds containing trace impurities, providing crucial analytical information that cannot be obtained by more traditional methodologies.


Asunto(s)
Cromatografía Liquida/métodos , Modelos Químicos , Preparaciones Farmacéuticas/química , Espectrometría de Masas en Tándem/métodos , Química Orgánica/métodos , Relación Señal-Ruido
3.
Anal Chem ; 83(11): 4068-75, 2011 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-21473579

RESUMEN

Collision-induced dissociation (CID) and electron-induced dissociation (EID) have been investigated for a selection of small, singly charged organic molecules of pharmaceutical interest. Comparison of these techniques has shown that EID carried out on an FTICR MS and CID performed on a linear ion trap MS produce complementary data. In a study of 33 molecule-cations, EID generated over 300 product ions compared to 190 product ions by CID with an average of only 3 product ions per precursor ion common to both tandem MS techniques. Even multiple stages of CID failed to generate many of the product ions observed following EID. The charge carrying species is also shown to have a very significant effect on the degree of fragmentation and types of product ion resulting from EID. Protonated species behave much like the ammonium adduct with suggestion of a hydrogen atom from the charge carrying species strongly affecting the fragmentation mechanism. Sodium and potassium are retained by nearly every product ion formed from [M + Na](+) or [M + K](+) and provide information to complement the EID of [M + H](+) or [M + NH(4)](+). In summary, EID is proven to be a fitting partner to CID in the structural elucidation of small singly charged ions and by studying EID of a molecule-ion holding different charge carrying species, an even greater depth of detail can be obtained for functional groups commonly used in synthetic chemistry.


Asunto(s)
Cationes/química , Electrones , Espectrometría de Masas/métodos , Preparaciones Farmacéuticas/química , Difenhidramina/química , Análisis de Fourier
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...