Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 6 de 6
1.
Sensors (Basel) ; 23(2)2023 Jan 06.
Article En | MEDLINE | ID: mdl-36679466

The accurate detection of fiducial points in the impedance cardiography signal (ICG) has a decisive impact on the proper estimation of diagnostic parameters such as stroke volume or cardiac output. It is, therefore, necessary to find an algorithm that is able to assess their positions with great precision. The solution to this problem is, however, quite challenging with regard to the high sensitivity of the ICG technique to the noise and varying morphology of the acquired signals. The aim of this study is to propose a novel method that allows us to overcome these limitations. The developed algorithm is based on Empirical Mode Decomposition (EMD)-an effective technique for processing and analyzing various types of non-stationary signals. We find high correlations between the results obtained from the algorithm and annotated by an expert. This, in turn, implies that the difference in estimation of the diagnostic-relevant parameters is small, which suggests that the method can automatically provide precise clinical information.


Cardiography, Impedance , Signal Processing, Computer-Assisted , Cardiography, Impedance/methods , Cardiac Output , Stroke Volume , Algorithms
2.
Sensors (Basel) ; 22(24)2022 Dec 15.
Article En | MEDLINE | ID: mdl-36560238

Accurate and reliable determination of the characteristic points of the impedance cardiogram (ICG) is an important research problem with a growing range of applications in the cardiological diagnostics of patients with heart failure (HF). The shapes of the characteristic waves of the ICG signal and the temporal location of the characteristic points B, C, and X provide significant diagnostic information. On this basis, essential diagnostic cardiological parameters can be determined, such as, e.g., cardiac output (CO) or stroke volume (SV). Although the importance of this problem is obvious, we face many challenges, including noisy signals and the big variability in the morphology, which altogether make the accurate identification of the characteristic points quite difficult. The paper presents an effective method of ICG points identification intended for conducting experimental research in the field of impedance cardiography. Its effectiveness is confirmed in clinical pilot studies.


Heart Failure , Humans , Pilot Projects , Electric Impedance , Cardiac Output , Stroke Volume , Heart Failure/diagnosis , Cardiography, Impedance/methods
3.
ACS Appl Nano Mater ; 5(10): 15762-15774, 2022 Oct 28.
Article En | MEDLINE | ID: mdl-36338322

A growing population suffering from or at high risk of developing cardiovascular diseases can benefit from rapid, precise, and readily available diagnostics. Textronics is an interdisciplinary approach for designing and manufacturing high-performance flexible electronics integrated with textiles for various applications, with electrocardiography (ECG) being the most convenient and most frequently used diagnostic technique for textronic solutions. The key challenges that still exist for textronics include expedient manufacturing, adaptation to human subjects, sustained operational stability for Holter-type data acquisition, reproducibility, and compatibility with existing solutions. The present study demonstrates conveniently paintable ECG electroconductive coatings on T-shirts woven from polyester or 70% polyamide and 30% polyester. The up to 600-µm-thick coatings encompass working electrodes of low resistivity 60 Ω sq-1 sheathed in the insulated pathways-conjugable with a wireless, multichannel ECG recorder. Long (800 µm) multiwalled carbon nanotubes, with scalable reproducibility and purity (18 g per round of synthesis), constituted the electroactive components and were embedded into a commercially available screen-printing acrylic base. The resulting paint had a viscosity of 0.75 Pa·s at 56 s-1 and 25 °C and was conveniently applied using a paintbrush, making this technique accessible to manufacturers. The amplified and nondigitally processed ECG signals were recorded under dry-skin conditions using a certified ECG recorder. The system enabled the collection of ECG signals from two channels, allowing the acquisition of cardiac electrical activity on six ECG leads with quality at par with medical diagnostics. Importantly, the Holter-type ECG allowed ambulatory recording for >24 h under various activities (sitting, sleeping, walking, and running) in three male participants. The ECG signal was stable for >5 cycles of washing, a level of stability not reported yet previously. The developed ECG-textronic application possesses acceptable and reproducible characteristics, making this technology a suitable candidate for further testing in clinical trials.

4.
JMIR Mhealth Uhealth ; 9(5): e25937, 2021 05 05.
Article En | MEDLINE | ID: mdl-33949964

Heart failure (HF) is a major clinical, social, and economic problem. In view of the important role of fluid overload in the pathogenesis of HF exacerbation, early detection of fluid retention is of key importance in preventing emergency admissions for this reason. However, tools for monitoring volume status that could be widely used in the home setting are still missing. The physical properties of human tissues allow for the use of impedance-based noninvasive methods, whose different modifications are studied in patients with HF for the assessment of body hydration. The aim of this paper is to present the current state of knowledge on the possible applications of these methods for remote (home-based) monitoring of patients with HF.


Cardiography, Impedance , Heart Failure , Heart Failure/diagnosis , Hemodynamics , Hospitalization , Humans
5.
Biomed Opt Express ; 11(2): 1043-1060, 2020 Feb 01.
Article En | MEDLINE | ID: mdl-32133236

A methodology for the assessment of the cerebral hemodynamic reaction to normotensive hypovolemia, reduction in cerebral perfusion and orthostatic stress leading to ischemic hypoxia and reduced muscular tension is presented. Most frequently, the pilots of highly maneuverable aircraft are exposed to these phenomena. Studies were carried out using the system consisting of a chamber that generates low pressure around the lower part of the body - LBNP (lower body negative pressure) placed on the tilt table. An in-house developed 6-channel NIRS system operating at 735 and 850 nm was used in order to assess the oxygenation of the cerebral cortex, based on measurements of diffusely reflected light in reflectance geometry. The measurements were carried out on a group of 12 active pilots and cadets of the Polish Air Force Academy and 12 healthy volunteers. The dynamics of changes in cerebral oxygenation was evaluated as a response to LBNP stimuli with a simultaneous rapid change of the tilt table angle. Parameters based on calculated changes of total hemoglobin concentration were proposed allowing to evaluate differences in reactions observed in control subjects and pilots/cadets. The results of orthogonal partial least squares-discriminant analysis based on these parameters show that the subjects can be classified into their groups with 100% accuracy.

6.
Sci Rep ; 8(1): 7793, 2018 05 17.
Article En | MEDLINE | ID: mdl-29773912

Lower body negative pressure (LBNP) is a method derived from space medicine, which in recent years has been increasingly used by clinicians to assess the efficiency of the cardiovascular regulatory mechanisms. LBNP with combined tilt testing is considered as an effective form of training to prevent orthostatic intolerance. We have developed a prototype system comprising a tilt table and LBNP chamber, and tested it in the context of the feasibility of the device for assessing the pilots' efficiency. The table allows for controlled tilting in the range from -45 to +80° at the maximum change rate of 45°/s. The LBNP value can smoothly be adjusted down to -100 mmHg at up to 20 mmHg/s. 17 subjects took part in the pilot study. A 24-minute scenario included -100 mmHg supine LBNP, head up tilt (HUT) and -60 mmHg LBNP associated with HUT, separated by resting phases. The most noticeable changes were observed in stroke volume (SV). During supine LBNP, HUT and the combined stimulus, a decrease of the SV value by 20%, 40% and below 50%, respectively, were detected. The proposed system can map any pre-programed tilt and LBNP profiles, and the pilot study confirmed the efficiency of performing experimental procedures.


Diagnostic Techniques, Cardiovascular , Lower Body Negative Pressure , Orthostatic Intolerance/diagnosis , Tilt-Table Test , Adult , Female , Humans , Male , Pilot Projects , Proof of Concept Study
...