Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 136
1.
J Cardiovasc Dev Dis ; 11(5)2024 Apr 29.
Article En | MEDLINE | ID: mdl-38786960

BACKGROUND: Infective endocarditis (IE) is marked by a heightened risk of embolic events (EEs), uncontrolled infection, or heart failure (HF). METHODS: Patients with IE and surgical indication were enrolled from October 2015 to December 2018. The primary endpoint consisted of a composite of major adverse events (MAEs) including all-cause death, hospitalizations, and IE relapses. The secondary endpoint was all-cause death. RESULTS: A total of 102 patients (66 ± 14 years) were enrolled: 50% with IE on prosthesis, 33% with IE-associated heart failure (IE-aHF), and 38.2% with EEs. IE-aHF and EEs were independently associated with MAEs (HR 1.9, 95% CI 1.1-3.4, p = 0.03 and HR 2.1, 95% CI 1.2-3.6, p = 0.01, respectively) and Kaplan-Meier survival curves confirmed a strong difference in MAE-free survival of patients with EEs and IE-aHF (p < 0.01 for both). IE-aHF (HR 4.3, 95% CI 1.4-13, p < 0.01), CRP at admission (HR 5.6, 95% CI 1.4-22.2, p = 0.01), LVEF (HR 0.9, 95% CI 0.9-1, p < 0.05), abscess (HR 3.5, 95% CI 1.2-10.6, p < 0.05), and prosthetic detachment (HR 4.6, 95% CI 1.5-14.1, p < 0.01) were independently associated with the all-cause death endpoint. CONCLUSIONS: IE-aHF and EEs were independently associated with MAEs. IE-aHF was also independently associated with the secondary endpoint.

4.
J Clin Med ; 12(19)2023 Sep 28.
Article En | MEDLINE | ID: mdl-37834910

BACKGROUND: Sutureless aortic bioprostheses are increasingly being used to provide shorter cross-clamp time and facilitate minimally invasive aortic valve replacement. As the use of sutureless valves has increased over the past decade, we begin to encounter their degeneration. We describe clinical outcomes and technical aspects in patients with degenerated sutureless Perceval (CorCym, Italy) aortic bioprosthesis treated with valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). METHODS: Between March 2011 and March 2023, 1310 patients underwent aortic valve replacement (AVR) with Perceval bioprosthesis implantation. Severe bioprosthesis degeneration treated with VIV-TAVR occurred in 32 patients with a mean of 6.4 ± 1.9 years (range: 2-10 years) after first implantation. Mean EuroSCORE II was 9.5 ± 6.4% (range: 1.9-35.1%). RESULTS: Thirty of thirty-two (94%) VIV-TAVR were performed via transfemoral and two (6%) via transapical approach. Vascular complications occurred in two patients (6%), and mean hospital stay was 4.6 ± 2.4 days. At mean follow-up of 16.7 ± 15.2 months (range: 1-50 months), survival was 100%, and mean transvalvular pressure gradient was 18.7 ± 5.3 mmHg. CONCLUSION: VIV-TAVR is a useful option for degenerated Perceval and appears safe and effective. This procedure is associated with good clinical results and excellent hemodynamic performance in our largest single-center experience.

5.
Surgery ; 174(5): 1153-1160, 2023 11.
Article En | MEDLINE | ID: mdl-37714757

BACKGROUND: Recent randomized controlled trials showed comparable short-term outcomes of transcatheter aortic valve implantation versus surgical aortic valve replacement in intermediate and low-risk patients. However, independent studies comparing transcatheter aortic valve implantation results versus surgical aortic valve replacement at 5 years showed worsening outcomes in patients treated with transcatheter aortic valve implantation. The aim of this study was to analyze mid- to long-term outcomes of patients with isolated aortic stenosis and an intermediate-risk profile who underwent aortic valve replacement using a sutureless valve versus transcatheter aortic valve implantation. METHODS: This retrospective multi-institutional European study investigated 2,123 consecutive patients with isolated aortic stenosis at intermediate risk profile treated with sutureless aortic valve replacement (824 patients) or transcatheter aortic valve implantation (1,299 patients) from 2013 to 2020. After 1:1 propensity score matching, 2 balanced groups of 517 patients were obtained. Primary endpoints were as follows: 30 days, late all-cause, and cardiac-related mortality. Secondary endpoints included major adverse cardiocerebrovascular events (all-cause death, stroke/transient ischemic attack, endocarditis, reoperation, permanent pacemaker implantation, and paravalvular leak grade ≥2). RESULTS: Median follow-up was 4.3 years (interquartile range 1.1-7.4 years). Primary endpoints were as follows-30-day mortality sutureless aortic valve replacement: 2.13% versus transcatheter aortic valve implantation: 4.64% (P = .026), all-cause mortality sutureless aortic valve replacement: 36.7% ± 7.8% vs transcatheter aortic valve implantation: 41.8% ± 8.2% (P = .023), and cardiac-related mortality sutureless aortic valve replacement: 10.2% ± 2.8% vs transcatheter aortic valve implantation: 19.2% ± 3.5%;(P = .00043) at follow-up. Secondary endpoints were as follows-major adverse cardiocerebrovascular events in the sutureless aortic valve replacement group: 47.2% ± 9.0% versus transcatheter aortic valve implantation: 57.3% ± 7.5% (P < .001). In particular, the incidence of permanent pacemaker implantation (sutureless aortic valve replacement: 6.38% versus transcatheter aortic valve implantation: 11.8% [P = .002]) and paravalvular leak ≥2 (sutureless aortic valve replacement: 0.97% versus transcatheter aortic valve implantation: 4.84% [P = .001]) was significantly higher in transcatheter aortic valve implantation group. At Multivariable Cox regression analysis, paravalvular leak ≥2 (hazard ratio: 1.63%; 95% confidence interval: 1.06-2.53, P = .042) and permanent pacemaker implantation (hazard ratio: 1.49%; 95% confidence interval: 1.02-2.20, P = .039) were identified as predictors of mortality. CONCLUSION: Sutureless aortic valve replacement showed a significantly lower incidence of all-cause mortality, cardiac-related death, permanent pacemaker implantation, and paravalvular leak than transcatheter aortic valve implantation. Moreover, permanent pacemaker implantation and paravalvular leak negatively affected survival in patients treated for isolated aortic stenosis.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Retrospective Studies , Risk Factors , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
6.
Article En | MEDLINE | ID: mdl-37307090

OBJECTIVES: Perceval sutureless valve has been in clinical use for >15 years. The aim of this study is to report the real-word clinical and haemodynamic performance from the SURE-aortic valve replacement international prospective registry in patients who underwent aortic valve replacement with Perceval valve. METHODS: From 2011 to 2021, patients from 55 institutions received a Perceval valve. Postoperative, follow-up, and echocardiographic outcomes were analysed. RESULTS: A total of 1652 patients were included; mean age was 75.3 ± 7.0 years (53.9% female); mean EuroSCORE II was 4.1 ± 6.3. Minimally invasive approach was performed in 45.3% of patients; concomitant procedures were done in 35.9% of cases. Within 30 days, 0.3 and 0.7% valve-related reinterventions were reported. Transient ischaemic attack, disabling and non-disabling strokes were limited (0.4%, 0.4% and 0.7%, respectively). Pacemaker implant was required in 5.7% of patients. Intra-prosthetic regurgitation ≥2 was present in 0.2% of cases, while paravalvular leak ≥2 in only 0.1%. At a maximum follow-up of 8 years, 1.9% of cardiovascular deaths and 0.8% of valve-related reintervention occurred. Among the 10 cases of structural valve deterioration (mean 5.6 ± 1.4 years after implant; range: 2.6-7.3 years), 9 were treated with a transcatheter vale-in-valve implantation and 1 with explant. Mean pressure gradient decreased from 45.8 ± 16.5 mmHg preoperatively to 13.3 ± 5.2 mmHg at discharge and remained stable during follow-up. CONCLUSIONS: This experience represents the largest prospective real-world cohort of patients treated with Perceval showing that Perceval is a safe and effective alternative to conventional surgical aortic valve replacement, providing favourable clinical and haemodynamic results also at mid-term follow-up.

7.
J Cardiovasc Dev Dis ; 10(5)2023 May 13.
Article En | MEDLINE | ID: mdl-37233180

Background: Frailty is highly common in older patients (pts) undergoing transcatheter aortic valve replacement (TAVR), and it is associated with poor outcomes. The selection of patients who can benefit from this procedure is necessary and challenging. The aim of the present study is to evaluate outcomes in older severe aortic valve stenosis (AS) pts, selected by a multidisciplinary approach for surgical, clinical, and geriatric risk and referred to treatment, according to frailty levels. Methods: A total of 109 pts (83 ± 5 years; females, 68%) with AS were classified by Fried's score in pre-frail, early frail, and frail and underwent surgical aortic valve replacement SAVR/TAVR, balloon aortic valvuloplasty, or medical therapy. We evaluated geriatric, clinical, and surgical features and detected periprocedural complications. The outcome was all-cause mortality. Results: Increasing frailty was associated with the worst clinical, surgical, geriatric conditions. By using Kaplan-Meier analysis, the survival rate was higher in pre-frail and TAVR groups (p < 0.001) (median follow-up = 20 months). By using the Cox regression model, frailty (p = 0.004), heart failure (p = 0.007), EF% (p = 0.043), albumin (p = 0.018) were associated with all-cause mortality. Conclusions: According to tailored frailty management, elderly AS pts with early frailty levels seem to be the most suitable candidates for TAVR/SAVR for positive outcomes because advanced frailty would make each treatment futile or palliative.

8.
J Cardiovasc Med (Hagerstown) ; 24(8): 506-513, 2023 08 01.
Article En | MEDLINE | ID: mdl-37115966

AIMS: We describe long-term clinical and echocardiographic outcomes in the largest single-centre cohort of patients who underwent aortic valve replacement (AVR) with sutureless Perceval (CorCym, Italy) bioprosthesis. METHODS: Between March 2011 and March 2021, 1157 patients underwent AVR with Perceval bioprosthesis implantation. Mean age was 77 ±â€Š6 years (range: 46-89 years) and mean EuroSCORE II was 6.7 ±â€Š3.2% (range: 1.7-14.2%). Concomitant procedures were performed in 266 patients (23%). RESULTS: Thirty-day mortality was 1.38% (16/1157). Eight hundred and twenty of 891 (92%) isolated AVRs underwent minimally invasive surgery with a ministernotomy ( n  = 196) or right minithoracotomy ( n  = 624) approach. Cardiopulmonary bypass and aortic cross-clamp times were 81.1 ±â€Š24.3 and 50.6 ±â€Š11.7 min for isolated AVR and 144.5 ±â€Š34.7 and 96.4 ±â€Š21.6 min for combined procedures. At mean follow-up of 53.08 ±â€Š6.7 months (range: 1-120.5 months), survival was 96.5% and mean transvalvular pressure gradient was 13.7 ±â€Š5.8 mmHg. Left ventricular mass decreased from 152.8 to 116.1 g/m 2 ( P  < 0.001) and moderate paravalvular leakage occurred in three patients without haemolysis not requiring any treatment. Freedom from reoperation was 97.6%. Eight patients required surgical reintervention and 19 patients transcatheter valve-in-valve procedure for structural prosthesis degeneration at a mean of 5.6 years after first operation (range: 2-9 years). CONCLUSION: AVR with a Perceval bioprosthesis is associated with good clinical results and excellent haemodynamic performance in our 10-year experience. Structural degeneration rate of Perceval is comparable with other bioprosthetic aortic valves. Sutureless technology may reduce operative time especially in combined procedures and enable minimally invasive AVR.


Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Aged , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Prosthesis Design , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
9.
Eur Heart J Case Rep ; 7(3): ytad077, 2023 Mar.
Article En | MEDLINE | ID: mdl-36895301

Aim: Hamartoma of mature cardiomyocytes is a rare tumor and the present case shows a complex diagnostic pathway to understand its nature and treatment options in a young patient. The myocardial bridge was also part of the clinical evaluation discovered during the diagnostic workout. Methods and results: A 27-year-old woman with atypical chest pain and a normal electrocardiogram received the diagnosis of neoformation of the interventricular septum with 18F-fluorodeoxyglucose (18F-FDG) uptake, and evidence of myocardial bridging on coronary angiography. On suspicion of malignancy, coronary unroofing and surgical biopsy was performed. The final diagnosis was hamartoma of mature cardiomyocytes. Conclusion: This case offers great insight into medical reasoning and decision-making process. Given the history of chest pain, the patient was evaluated for possible ischemic, embolic, or vascular causes. Given a left ventricular wall thickness ≥15 mm, hypertrophic cardiomyopathy (HCM) should always be suspected; nuclear magnetic resonance imaging is essential to distinguish between HCM. The magnetic resonance imaging is also critical in distinguishing HCM itself from tumoral phenocopies. To rule out a neoplastic process, 18F-FDG positron emission tomography (PET) was used. A surgical biopsy was performed, and the final diagnosis was completed after the immune-histochemistry study. A myocardial bridge was found during preoperative coronagraphy and was treated accordingly.

10.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Article En | MEDLINE | ID: mdl-36257545

OBJECTIVES: The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR). METHODS: We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date: an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019). RESULTS: The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time. CONCLUSION: Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pacemaker, Artificial , Sutureless Surgical Procedures , Humans , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Research Report , Treatment Outcome , Prosthesis Design , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Sutureless Surgical Procedures/adverse effects
11.
Int J Cardiol ; 371: 116-120, 2023 Jan 15.
Article En | MEDLINE | ID: mdl-36108764

OBJECTIVES: The role of the underlying etiology in isolated tricuspid valve surgery has not been investigated extensively in current literature. Aim of this study was to analyse outcomes of patients undergoing surgery due to endocarditis compared to other pathologies. METHODS: The SURTRI study is a multicenter study enrolling adult patients who underwent isolated tricuspid valve surgery (n = 406, 55 ± 16 y.o.; 56% female) at 13 international sites. Propensity weighted analysis was performed to compare groups (IE group n = 107 vs Not-IE group n = 299). RESULTS: No difference was found regarding the 30-day mortality (Group IE: 2.8% vs Group Not-IE = 6.8%; OR = 0.45) and major adverse events. Weighted cumulative incidence of cardiac death was significantly higher for patients with endocarditis (p = 0.01). The composite endpoint of cardiac death and reoperation at 6 years was reduced in the Group IE (63.2 ± 6.8% vs 78.9 ± 3.1%; p = 0.022). Repair strategy resulted in an increased late survival even in IE cases. CONCLUSIONS: Data from SURTRI study report acceptable 30-day results but significantly reduced late survival in the setting of endocarditis of the tricuspid valve. Multi-disciplinary approach, repair strategy and earlier treatment may improve outcomes.


Endocarditis , Heart Valve Prosthesis Implantation , Adult , Humans , Female , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Prognosis , Treatment Outcome , Endocarditis/diagnosis , Endocarditis/surgery , Endocarditis/etiology , Reoperation , Death , Heart Valve Prosthesis Implantation/methods , Retrospective Studies
12.
Life (Basel) ; 12(12)2022 Dec 16.
Article En | MEDLINE | ID: mdl-36556489

Patients with previously diagnosed HF are at greater risk for subsequent morbidity and mortality when hospitalized for an Acute Myocardial Infarction (AMI). The purpose of our study was to describe the time trend of the incidence of emergent CABG in patients with and without HF, the clinical characteristics, outcomes, and the risk factors for mortality of surgical revascularization in the short and medium term. This was a single-center retrospective observational study of patients who underwent isolated emergency CABG from January 2009 to January 2020. A propensity-score matching analysis yielded two comparable groups (n = 430) of patients without (n = 215) and with (n = 215) heart failure. In-hospital mortality did not differ in the two groups (2.8%; p > 0.9); the patients with heart failure presented more frequently with cardiogenic shock, and there was an association with mortality and mechanical circulatory support (OR 16.7−95% CI 3.31−140; p = 0.002) and postoperative acute renal failure (OR 15.9−95% CI 0.66−203; p = 0.036). In the early- and mid-term, heart failure and NSTEMI were associated with mortality (HR 3.47−95% CI 1.15−10.5; p = 0.028), along with age (HR 1.28−95% CI 1.21−1.36; p < 0.001). Surgical revascularization offers an excellent solution for patients with acute coronary syndrome, leading to a good immediate prognosis even in those with chronic heart failure.

13.
Cardiovasc Ultrasound ; 20(1): 28, 2022 Nov 28.
Article En | MEDLINE | ID: mdl-36443797

BACKGROUND: Venous thromboembolism represents the third most frequent acute cardiovascular syndrome worldwide. Its clinical manifestations are deep vein thrombosis and/or pulmonary embolism. Despite a considerable mortality, diagnosis is often missed.  CASE PRESENTATION: We report the management of a female patient with high-risk pulmonary thromboembolism treated initially with thromboaspiration, complicated by embolus jailing in a patent foramen ovale. In this situation, left cardiac chambers and systemic circulation were jeopardized by this floating embolus. CONCLUSIONS: High-risk pulmonary embolism requires reperfusion strategy but sometimes mechanical thromboaspiration may be not fully successful; transesophageal echocardiography led to a prompt diagnosis of this unexpected finding; in this very particular case, open surgery represented a bail-out procedure to avoid cerebral and systemic embolism.


Foramen Ovale, Patent , Pulmonary Embolism , Thromboembolism , Female , Humans , Foramen Ovale, Patent/diagnosis , Foramen Ovale, Patent/diagnostic imaging , Heart , Echocardiography, Transesophageal , Pulmonary Embolism/complications , Pulmonary Embolism/diagnosis
14.
Front Cardiovasc Med ; 9: 943068, 2022.
Article En | MEDLINE | ID: mdl-35966562

Introduction: Primary mitral valve regurgitation (MR) results from degeneration of mitral valve apparatus. Mechanisms leading to incomplete postoperative left ventricular (LV) reverse remodeling (Rev-Rem) despite timely and successful surgical mitral valve repair (MVR) remain unknown. Plasma exosomes (pEXOs) are smallest nanovesicles exerting early postoperative cardioprotection. We hypothesized that late plasma exosomal microRNAs (miRs) contribute to Rev-Rem during the late postoperative period. Methods: Primary MR patients (n = 19; age, 45-71 years) underwent cardiac magnetic resonance imaging and blood sampling before (T0) and 6 months after (T1) MVR. The postoperative LV Rev-Rem was assessed in terms of a decrease in LV end-diastolic volume and patients were stratified into high (HiR-REM) and low (LoR-REM) LV Rev-Rem subgroups. Isolated pEXOs were quantified by nanoparticle tracking analysis. Exosomal microRNA (miR)-1, -21-5p, -133a, and -208a levels were measured by RT-qPCR. Anti-hypertrophic effects of pEXOs were tested in HL-1 cardiomyocytes cultured with angiotensin II (AngII, 1 µM for 48 h). Results: Surgery zeroed out volume regurgitation in all patients. Although preoperative pEXOs were similar in both groups, pEXO levels increased after MVR in HiR-REM patients (+0.75-fold, p = 0.016), who showed lower cardiac mass index (-11%, p = 0.032). Postoperative exosomal miR-21-5p values of HiR-REM patients were higher than other groups (p < 0.05). In vitro, T1-pEXOs isolated from LoR-REM patients boosted the AngII-induced cardiomyocyte hypertrophy, but not postoperative exosomes of HiR-REM. This adaptive effect was counteracted by miR-21-5p inhibition. Summary/Conclusion: High levels of miR-21-5p-enriched pEXOs during the late postoperative period depict higher LV Rev-Rem after MVR. miR-21-5p-enriched pEXOs may be helpful to predict and to treat incomplete LV Rev-Rem after successful early surgical MVR.

16.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Article En | MEDLINE | ID: mdl-35775935

OBJECTIVES: To compare procedural and in-hospital outcomes of patients undergoing sutureless (Perceval, Livanova PLC, London, UK) and rapid deployment (Intuity Elite, Edwards Lifesciences, Irvine, CA, USA) aortic valve replacement (group 1) versus sutured aortic valve replacement (group 2). METHODS: Patients receiving isolated aortic valve replacement between 2014 and 2020 were analysed using data from the Sutureless and Rapid Deployment International Registry. Patients in group 1 and group 2 were propensity-score matched in a 1:1 ratio. RESULTS: A total of 7708 patients were included in the study. After matching, 2 groups of 2643 each were created. Patients in group 1 were more likely to undergo minimally invasive approaches and were associated with shorter operative times when compared with group 2. Overall in-hospital mortality was similar between groups. While an increased risk of stroke was observed in group 1 in the first study period (2014-2016; relative risk 3.76, P < 0.001), no difference was found in more recent year period (relative risk 1.66, P = 0.08; P for heterogeneity 0.003). Group 1 was associated with reduced rates of postoperative low cardiac output syndrome, atrial fibrillation and mild aortic regurgitation. New pacemaker implant was three-fold higher in group 1. CONCLUSIONS: Our findings showed significant differences in procedural and clinical outcomes between the study groups. These results suggest that sutureless and rapid deployment aortic valve replacement should be considered as part of a comprehensive valve programme. The knowledge of the respective post-aortic valve replacement benefits for different valve technologies may result in patient-tailored valve selection with improved clinical outcomes.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Sutureless Surgical Procedures , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Humans , Prosthesis Design , Registries , Treatment Outcome
17.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Article En | MEDLINE | ID: mdl-35448903

OBJECTIVES: The interest in isolated tricuspid valve disease has rapidly increased recently. However, clinical trials and registry data are rare in the surgical literature. This study aimed to describe the early and long-term outcomes of a real-world experience in isolated tricuspid procedures comparing repair and replacement strategies. METHODS: The Surgical-Tricuspid study is a multicentre retrospective study that enrolled adult patients who had undergone isolated tricuspid valve surgery at 13 international sites. Propensity score-matched analysis was used to compare repair versus replacement. RESULTS: A cohort of 426 patients was enrolled [mean age: 55 (16) years; 56% female]. After matching, 175 comparable pairs were analysed. Preoperative left ventricular ejection fraction was 55(9) vs 56(9) (P = 0.8) while moderate-severe tricuspid regurgitation was present in 95% of cases. The 30-day mortality rate was 4.0% vs 8.0% in the repair and replacement groups, respectively (P = 0.115). The rates of re-exploration for bleeding (6.9% vs 13.1% P = 0.050), permanent pacemaker implantation (5.1% vs 12.0%; P = 0.022) and blood transfusion (46% vs 62%; P = 0.002) were higher in the replacement group. Cumulative survival rates at 3, 5 and 7 years in the repair group were 84 (3)%, 75 (4)% and 56 (9)% vs 71 (4)%, 66 (5)% and 58 (5)% in the replacement group (P = 0.001) while cumulative incidence for reoperation at 10 years did not differ between groups [repair 10 (1)% vs replacement 9 (1)%; P = 0.469]. CONCLUSIONS: The data from the Surgical-Tricuspid study reported a high risk for patients undergoing tricuspid surgery. Isolated valve repair offered reduced early and late mortality with no difference regarding reoperation rate when compared with replacement.


Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Adult , Female , Heart Valve Prosthesis Implantation/methods , Humans , Male , Middle Aged , Retrospective Studies , Stroke Volume , Treatment Outcome , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/etiology , Ventricular Function, Left
18.
J Card Surg ; 37(7): 1959-1966, 2022 Jul.
Article En | MEDLINE | ID: mdl-35385588

BACKGROUND: Aim of this study is to analyse the performances of Clinical Risk Score (CRS) and European System for Cardiac Operative Risk Evaluation (EuroSCORE)-II in isolated tricuspid surgery. METHODS: Three hundred and eighty-three patients (54 ± 16 year; 54% female) were enrolled. Receiver operating characteristic analysis was performed to evaluate the relationship between the true positive fraction of test results and the false-positive fraction for a procedure. RESULTS: Considering the 30-day mortality the area under the curve was 0.6 (95% confidence interval [CI] 0.50-0.72) for EuroSCORE II and 0.7 (95% CI 0.56-0.84) for CRS-score. The ratio of expected/observed mortality showed underestimation when considering EuroSCORE-II (min. 0.46-max. 0.6). At multivariate analysis, the CRS score (p = .005) was predictor of late cardiac death. CONCLUSION: We suggest using both scores to obtain a range of expected mortality. CRS to speculate on late survival.


Cardiac Surgical Procedures , Tricuspid Valve , Female , Hospital Mortality , Humans , Male , ROC Curve , Retrospective Studies , Risk Assessment , Risk Factors , Tricuspid Valve/surgery
19.
J Thorac Cardiovasc Surg ; 163(3): 925-935.e5, 2022 Mar.
Article En | MEDLINE | ID: mdl-32727681

OBJECTIVE: This multi-institutional study compares the long-term outcome of elderly patients with severe aortic stenosis and an intermediate risk profile undergoing sutureless versus transcatheter aortic valve implantation. METHODS: From 2008 to 2015, 967 elderly patients (>75 years) with intermediate risk (Society of Thoracic Surgeons score 4%-8%) and isolated aortic stenosis were included in the study (sutureless valve = 481; transcatheter aortic valve implantation = 486). After propensity score matching, 2 matched groups of 291 patients were obtained. Transcatheter valves implanted in patients were the CoreValve (Medtronic, Minneapolis, Minn), Edwards SAPIEN-XT (Edwards Lifesciences, Irvine, Calif), and Acurate-TA (Symetis, Lausanne, Switzerland). Primary end points included all-cause death at 30 days and 5 years. Secondary end points included early and 5-year incidence of composite adverse events (major adverse cardiovascular events: all-cause death, stroke, pacemaker implant, myocardial infarction, paravalvular leak ≥II, and reoperation). RESULTS: After matching, there were no substantial differences between groups. The 30-day mortality was significantly lower in the sutureless valve group (sutureless valve = 1.7% vs transcatheter aortic valve implantation = 5.5%; P = .024) and the rate of permanent pacemaker implantation (sutureless valve = 5.5% vs transcatheter aortic valve implantation = 10.7%, P = .032). Stroke/transient ischemic attack cumulative incidence at 5 years was 1.4% in the sutureless valve group and 5.3% in the transcatheter aortic valve implantation group (P = .010). The incidence of perivalvular leak grade II or greater was 1.3% in the sutureless valve group and 9.8% in the transcatheter aortic valve implantation group (P < .001). At 60 months follow-up, the all-cause death rate was lower in the sutureless valve group than in the transcatheter aortic valve implantation group (sutureless valve = 16.1% ± 4.1% vs transcatheter aortic valve implantation = 28.9% ± 5.3%, P = .006), and the major adverse cardiovascular event rate was lower in the sutureless valve group (sutureless valve = 23.5% ± 4.1% vs transcatheter aortic valve implantation = 39.0% ± 5.6%, P = .002). Multivariable Cox regression identified transcatheter aortic valve implantation as an independent predictor for 5-year mortality and major adverse cardiovascular events (hazard ratio, 1.86; confidence interval, 1.09-3.18; P = .022) (hazard ratio, 1.73; confidence interval, 1.13-2.73; P = .010). CONCLUSIONS: Sutureless valves improved the outcomes of aortic stenosis in elderly patients with an intermediate risk profile when compared with transcatheter aortic valve implantation. The use of transcatheter aortic valve implantation in this subset population should be evaluated in further controlled randomized trials with sutureless valve use in a comparative cohort.


Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Sutureless Surgical Procedures/instrumentation , Transcatheter Aortic Valve Replacement/instrumentation , Age Factors , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Europe , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Postoperative Complications/mortality , Postoperative Complications/surgery , Prosthesis Design , Reoperation , Retrospective Studies , Risk Assessment , Risk Factors , Sutureless Surgical Procedures/adverse effects , Sutureless Surgical Procedures/mortality , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
20.
Ann Thorac Surg ; 114(3): 758-765, 2022 09.
Article En | MEDLINE | ID: mdl-34563505

BACKGROUND: This study compared clinical and hemodynamic in-hospital outcomes of patients undergoing sutureless vs rapid deployment aortic valve replacement (SURD-AVR) in the large population of the Sutureless and Rapid Deployment International Registry (SURD-IR). METHODS: We examined 4695 patients who underwent isolated or combined SURD-AVR. The "sutureless" Perceval valve (LivaNova PLC, London, United Kingdom) was used in 3133 patients and the "rapid deployment" Intuity (Edwards Lifesciences, Irvine, CA) in 1562. Potential confounding factors were addressed by the use of propensity score matching. After matching, 2 well-balanced cohorts of 823 pairs (isolated SURD-AVR) and 467 pairs (combined SURD-AVR) were created. RESULTS: Patients who received Perceval and Intuity valves showed similar in-hospital mortality and rate of major postoperative complications. Perceval was associated shorter cross-clamp and cardiopulmonary bypass times. In the isolated SURD-AVR group, patients receiving Perceval were more likely to undergo anterior right thoracotomy incision. Postoperative transvalvular gradients were significantly lower for the Intuity valve compared with those of the Perceval valve, either in isolated and combined SURD-AVR. The Intuity valve was associated with a lower rate of postoperative mild aortic regurgitation. CONCLUSIONS: Our results confirm the safety and efficacy of SURD-AVR regardless of the valve type. The Perceval valve was associated with reduced operative times and increased anterior right thoracotomy incision. The Intuity valve showed superior hemodynamic outcomes and a lower incidence of postoperative mild aortic regurgitation.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/methods , Humans , Prosthesis Design , Registries , Retrospective Studies , Treatment Outcome
...