Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Int J Artif Organs ; 46(10-11): 547-554, 2023.
Article En | MEDLINE | ID: mdl-37753863

The mechanisms underlying vascular stenosis formation in the arteriovenous fistula (AVF) for hemodialysis (HD) remain mostly unknown. Several computational fluid dynamics (CFD) studies have suggested a potential role for unsteady flow in inducing intimal hyperplasia and AVF stenosis, but the majority of these observations have been limited to a single time point after surgical creation. The aim of the present study was to investigate the relation between hemodynamic conditions and AVF vascular remodeling through a CFD longitudinal study. Non contrast-enhanced MR images and Doppler Ultrasound (US) examinations were acquired at 3 days, 40 days, 6 months, 1 year, and 1.5 years after surgery in a 72-year male referred for native radio-cephalic AVF. Three-dimensional AVF models were generated and high fidelity CFD simulations were performed using pimpleFoam, setting patient-specific boundary conditions derived from US. Morphological and hemodynamic changes over time were then analyzed. Analysis of vessel morphology and hemodynamics during follow-up showed that the AVF had a successful maturation process, characterized by a massive arterial and venous dilatation within the 6 months after surgery, a corresponding increase in blood flow volume and important flow instabilities. Between 6 months and 1 year, a stenosis developed in the juxta-anastomotic vein and caused AVF failure at 1.5 years. The development of stenosis was paralleled by the regularization of blood flow velocity pattern and consequent decrease in the near-wall disturbed flow metrics. These results suggest that development of intimal hyperplasia and vessel stenosis, triggered by unsteady flow, could be the result of vascular inward remodeling toward regularization of turbulent-like flow.


Arteriovenous Fistula , Arteriovenous Shunt, Surgical , Humans , Male , Arteriovenous Shunt, Surgical/adverse effects , Arteriovenous Shunt, Surgical/methods , Longitudinal Studies , Vascular Remodeling , Constriction, Pathologic , Hyperplasia , Hemodynamics/physiology , Renal Dialysis
2.
J Vasc Access ; : 11297298221087160, 2022 Apr 22.
Article En | MEDLINE | ID: mdl-35451351

BACKGROUND: Arteriovenous fistula (AVF) is the preferred vascular access (VA) for hemodialysis, but it is still affected by high non-maturation and early failure rates due to stenosis development. Increasing evidence suggests that the presence of turbulent-like flow may play a key role, therefore, to stabilize the flow in the venous segment, an external support device (VasQTM) has been designed. The aim of this study was to provide preliminary evidence of VasQTM impact on AVF hemodynamics as compared to AVFs created with conventional surgery. METHODS: In this pilot single-center prospective randomized study six patients were enrolled, three in the VasQ group and three in the control group. Contrast-free magnetic resonance imaging (MRI) scans were acquired at 3 days, 3 months and 1 year after AVF surgery and were used to generate 3D patient-specific models. Computational fluid dynamic (CFD) simulations were performed using pimpleFoam, imposing patient-specific flow waveforms derived from ultrasound (US) examinations at the inlet of the proximal and distal artery, and a traction-free condition at the venous outflow. Morphologic and hemodynamic changes occurring over time were compared between VasQ and control AVFs. RESULTS: Our MRI protocol provided high-quality images suitable for reliable segmentation and reconstruction of patient-specific 3D models of AVFs at all three timepoints in four out of six patients. The VasQTM device maintained the angle between the artery and the vein almost unchanged over time, with a more stable flow in the AVFs supported by the device. In contrast, one of the AVFs of the control group evolved to an extreme dilatation of the vein and highly disturbed flow, while the other developed a stenosis in the juxta-anastomotic region. CONCLUSIONS: This study demonstrated the feasibility of characterizing the morphological and hemodynamic changes occurring over time in AVFs created using the VasQTM device and provided preliminary evidence of the potential hemodynamic benefits of its use.

3.
Stud Health Technol Inform ; 279: 46-53, 2021 May 07.
Article En | MEDLINE | ID: mdl-33965918

BACKGROUND: Telerehabilitation represents a new cutting-edge method in the treatment of patients suffering from motor and cognitive disorders caused by stroke. Even if there exist dedicated devices able to track patients' movements to evaluate the performed rehabilitation exercises, they require specific settings necessary for a correct and simple use at the patient's home. If we consider the recent pandemic situation and the lockdown condition, which made difficult the access to these products, post stroke patients may be not able to perform home rehabilitation. OBJECTIVES: the goal of this work is the design of a specific method to develop a tele-rehabilitation platform for post-stroke patients using consumer technologies without involving ad-hoc devices. METHOD: Open-source tools have been investigated for speeding up the development starting with the medical knowledge. RESULTS: a group of four healthcare technologies engineering students with no specific skills about computer science has developed a platform in four months using the design method. CONCLUSION: the presented method allowed the development of a clinical knowledge-based web platform for post-stroke patients totally based on consumer technology.


Stroke Rehabilitation , Stroke , Telerehabilitation , Exercise Therapy , Humans , Technology
...