Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
2.
J Am Coll Cardiol ; 81(21): 2115-2127, 2023 05 30.
Article En | MEDLINE | ID: mdl-37225366

Mechanical prosthetic heart valves, though more durable than bioprostheses, are more thrombogenic and require lifelong anticoagulation. Mechanical valve dysfunction can be caused by 4 main phenomena: 1) thrombosis; 2) fibrotic pannus ingrowth; 3) degeneration; and 4) endocarditis. Mechanical valve thrombosis (MVT) is a known complication with clinical presentation ranging from incidental imaging finding to cardiogenic shock. Thus, a high index of suspicion and expedited evaluation are essential. Multimodality imaging, including echocardiography, cine-fluoroscopy, and computed tomography, is commonly used to diagnose MVT and follow treatment response. Although surgery is oftentimes required for obstructive MVT, other guideline-recommended therapies include parenteral anticoagulation and thrombolysis. Transcatheter manipulation of stuck mechanical valve leaflet is another treatment option for those with contraindications to thrombolytic therapy or prohibitive surgical risk or as a bridge to surgery. The optimal strategy depends on degree of valve obstruction and the patient's comorbidities and hemodynamic status on presentation.


Bioprosthesis , Heart Valve Prosthesis , Thrombosis , Humans , Thrombosis/diagnosis , Thrombosis/etiology , Thrombosis/therapy , Heart Valve Prosthesis/adverse effects , Anticoagulants/therapeutic use , Heart Valves
3.
EuroIntervention ; 18(5): e407-e416, 2022 Aug 05.
Article En | MEDLINE | ID: mdl-35321859

BACKGROUND: Given enough time, transcatheter heart valves (THVs) will degenerate and may require reintervention. Redo transcatheter aortic valve implantation (TAVI) is an attractive strategy but carries a risk of coronary obstruction. AIMS: We sought to predict how many TAVIs patients could undergo in their lifetime using computed tomography (CT) simulation. METHODS: We analysed paired CT scans (baseline and 30 days post-TAVI) from patients in the LRT trial and EPROMPT registry. We implanted virtual THVs on baseline CTs, comparing predicted valve-to-coronary (VTC) distances to 30-day CT VTC distances to evaluate the accuracy of CT simulation. We then simulated implantation of a second virtual THV within the first to estimate the risk of coronary obstruction due to sinus sequestration and the need for leaflet modification. RESULTS: We included 213 patients with evaluable paired CTs. There was good agreement between virtual (baseline) and actual (30 days) CT measurements. CT simulation of TAVI followed by redo TAVI predicted low coronary obstruction risk in 25.4% of patients and high risk, likely necessitating leaflet modification, in 27.7%, regardless of THV type. The remaining 46.9% could undergo redo TAVI so long as the first THV was balloon-expandable but would likely require leaflet modification if the first THV was self-expanding. CONCLUSIONS: Using cardiac CT simulation, it is possible to predict whether a patient can undergo multiple TAVI procedures in their lifetime. Those who cannot may prefer to undergo surgery first. CT simulation could provide a personalised lifetime management strategy for younger patients with symptomatic severe aortic stenosis and inform decision-making. CLINICALTRIALS: gov: NCT02628899; ClinicalTrials.gov: NCT03557242; ClinicalTrials.gov: NCT03423459.


Aortic Valve Stenosis , Coronary Occlusion , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Coronary Occlusion/surgery , Humans , Prosthesis Design , Tomography , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
...