1.
Heart Rhythm ; 2024 Mar 13.
Article En | MEDLINE | ID: mdl-38490597

BACKGROUND: Many patients with mildly to moderately reduced left ventricular ejection fraction (LVEF) who require permanent pacemaker (PPM) implantation do not have a concurrent indication for implantable cardioverter-defibrillator (ICD) therapy. However, the risk of ventricular tachycardia/ventricular fibrillation (VT/VF) in this population is unknown. OBJECTIVE: The aim of this study was to describe the risk of VT/VF after PPM implantation in patients with mildly to moderately reduced LVEF. METHODS: Retrospective analysis was performed of 243 patients with LVEF between 35% and 49% who underwent PPM placement and did not meet indications for an ICD. The primary end point was occurrence of sustained VT/VF. Competing risks regression was performed to calculate subhazard ratios for the primary end point. RESULTS: Median follow-up was 27 months; 73% of patients were male, average age was 79 ± 10 years, average LVEF was 42% ± 4%, and 70% were New York Heart Association class II or above. Most PPMs were implanted for sick sinus syndrome (34%) or atrioventricular block (50%). Of 243 total patients, 11 (4.5%) met the primary end point of VT/VF. Multivessel coronary artery disease (CAD) was associated with significantly higher rates of VT/VF, with a subhazard ratio of 5.4 (95% CI, 1.5-20.1; P = .01). Of patients with multivessel CAD, 8 of 82 (9.8%) patients met the primary end point for an annualized risk of 4.3% per year. CONCLUSION: Patients with mildly to moderately reduced LVEF and multivessel CAD undergoing PPM implantation are at increased risk for the development of malignant ventricular arrhythmias. Patients in this population may benefit from additional risk stratification for VT/VF and consideration for upfront ICD implantation.

2.
Heart Rhythm ; 20(6): 808-814, 2023 06.
Article En | MEDLINE | ID: mdl-36863636

BACKGROUND: Established electroanatomic mapping techniques for substrate mapping for ventricular tachycardia (VT) ablation includes voltage mapping, isochronal late activation mapping (ILAM), and fractionation mapping. Omnipolar mapping (Abbott Medical, Inc.) is a novel optimized bipolar electrogram creation technique with integrated local conduction velocity annotation. The relative utilities of these mapping techniques are unknown. OBJECTIVE: The purpose of this study was to evaluate the relative utility of various substrate mapping techniques for the identification of critical sites for VT ablation. METHODS: Electroanatomic substrate maps were created and retrospectively analyzed in 27 patients in whom 33 VT critical sites were identified. RESULTS: Both abnormal bipolar voltage and omnipolar voltage encompassed all critical sites and were observed over a median of 66 cm2 (interquartile range [IQR] 41.3-86 cm2) and 52 cm2 (IQR 37.7-65.5 cm2), respectively. ILAM deceleration zones were observed over a median of 9 cm2 (IQR 5.0-11.1 cm2) and encompassed 22 critical sites (67%), while abnormal omnipolar conduction velocity (CV <1 mm/ms) was observed over 10 cm2 (IQR 5.3-16.6 cm2) and identified 22 critical sites (67%), and fractionation mapping was observed over a median of 4 cm2 (IQR 1.5-7.6 cm2) and encompassed 20 critical sites (61%). The mapping yield was the highest for fractionation + CV (2.1 critical sites/cm2) and least for bipolar voltage mapping (0.5 critical sites/cm2). CV identified 100% of critical sites in areas with a local point density of >50 points/cm2. CONCLUSION: ILAM, fractionation, and CV mapping each identified distinct critical sites and provided a smaller area of interest than did voltage mapping alone. The sensitivity of novel mapping modalities improved with greater local point density.


Catheter Ablation , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Retrospective Studies , Electrophysiologic Techniques, Cardiac/methods , Catheter Ablation/methods
3.
J Cardiovasc Electrophysiol ; 34(4): 800-807, 2023 04.
Article En | MEDLINE | ID: mdl-36738147

INTRODUCTION: Radiofrequency ablation technology for treating atrial fibrillation (AF) has evolved rapidly over the past decade. We investigated the impact of technological and procedural advances on procedure times and ablation outcomes at a major academic medical center over a 10-year period. METHODS: Clinical data was collected from patients who presented to NYU Langone Health between 2011 and 2021 for a first-time AF ablation. Time to redo AF ablation or direct current cardioversion (DCCV) for recurrent AF during a 3-year follow-up period was determined and correlated with ablation technology and practices, antiarrhythmic medications, and patient comorbid conditions. RESULTS: From 2011 to 2021, the cardiac electrophysiology lab adopted irrigated-contact force ablation catheters, high-power short duration ablation lesions, steady-pacing, jet ventilation, and eliminated stepwise linear ablation for AF ablation. During this time the number of first time AF ablations increased from 403 to 1074, the percentage of patients requiring repeat AF-related intervention within 3-years of the index procedure dropped from 22% to 14%, mean procedure time decreased from 271 ± 65 to 135 ± 36 min, and mean annual major adverse event rate remained constant at 1.1 ± 0.5%. Patient comorbid conditions increased during this time period and antiarrhythmic use was unchanged. CONCLUSION: Rates of redo-AF ablation or DCCV following an initial AF ablation at a single center decreased 36% over a 10-year period. Procedural and technological changes likely contributed to this improvement, despite increased AF related comorbidities.


Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Time Factors , Catheter Ablation/methods
4.
J Cardiovasc Electrophysiol ; 34(3): 575-582, 2023 03.
Article En | MEDLINE | ID: mdl-36511474

INTRODUCTION: Patients with HIV infection have increased risk of atrial fibrillation, but the pathophysiologic mechanisms and the utility of catheter ablation in this population are not well-studied. We aimed to characterize outcomes of atrial fibrillation ablation and left atrial substrate in patients with HIV. METHODS: The study was a retrospective propensity score-matched analysis of patients with and without HIV undergoing atrial fibrillation ablation. A search was performed in the electronic medical record for all patients with HIV who received initial atrial fibrillation ablation from 2011 to 2020. After calculating propensity scores for HIV, matching was performed with patients without HIV by using nearest-neighbor matching without replacement in a 1:2 ratio. The primary outcome was freedom from atrial arrhythmia and secondary outcomes were freedom from atrial fibrillation, freedom from atrial tachycardia, and freedom from repeat ablation, compared by log-rank analysis. The procedures of patients with HIV who underwent repeat ablation at our institution were further analyzed for etiology of recurrence. To further characterize the left atrial substrate, a subsequent case-control analysis was then performed for a set of randomly chosen 10 patients with HIV matched with 10 without HIV to compare minimum and maximum voltage at nine pre-specified regions of the left atrium. RESULTS: Twenty-seven patients with HIV were identified. All were prescribed antiretroviral therapy at time of ablation. These patients were matched with 54 patients without HIV by propensity score. 86.4% of patients with HIV and 76.9% of controls were free of atrial fibrillation or atrial tachycardia at 1 year (p = .509). Log-rank analysis showed no difference in freedom from atrial arrhythmia (p value .971), atrial fibrillation (p-value .346), atrial tachycardia (p value .306), or repeat ablation (p value .401) after initial atrial fibrillation ablation in patients with HIV compared to patients without HIV. In patients with HIV with recurrent atrial fibrillation, the majority had pulmonary vein reconnection (67%). There were no significant differences in minimum or maximum voltage at any of the nine left atrial regions between the matched patients with and without HIV. CONCLUSIONS: Ablation to treat atrial fibrillation in patients with HIV, but without overt AIDS is frequently successful therapy. The majority of patients with recurrence of atrial fibrillation had pulmonary vein reconnection, suggesting infrequent nonpulmonary vein substrate. In this population, the left atrial voltage in patients with HIV is similar to that of patients without HIV. These findings suggest that the pulmonary veins remain a critical component to the initiation and maintenance of atrial fibrillation in patients with HIV.


Atrial Fibrillation , Catheter Ablation , HIV Infections , Pulmonary Veins , Tachycardia, Supraventricular , Humans , Atrial Fibrillation/surgery , Retrospective Studies , HIV Infections/complications , HIV Infections/surgery , Treatment Outcome , Heart Atria , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Recurrence
5.
Heart Rhythm ; 19(5): 759-767, 2022 05.
Article En | MEDLINE | ID: mdl-35038570

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is the most prevalent inherited cardiomyopathy. The implantable cardioverter-defibrillator (ICD) is important for prevention of sudden cardiac death (SCD) in patients at high risk. In recent years, the subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as a viable alternative to the transvenous implantable cardioverter-defibrillator (TV-ICD). The S-ICD does not require intravascular access; however, it cannot provide antitachycardia pacing (ATP) therapy. OBJECTIVE: The purpose of this study was to assess the real-world incidence of ICD therapy in patients with HCM implanted with TV-ICD vs S-ICD. METHODS: We compared the incidence of ATP and shock therapies among all HCM patients with S-ICD and TV-ICD enrolled in the Boston Scientific ALTITUDE database. Cumulative Kaplan-Meier incidence was used to compare therapy-free survival, and Cox proportional hazard ratios were calculated. We performed unmatched as well as propensity match analyses. RESULTS: We included 2047 patients with TV-ICD and 626 patients with S-ICD, followed for an average of 1650.5 ± 1038.5 days and 933.4 ± 550.6 days, respectively. Patients with HCM and TV-ICD had a significantly higher rate of device therapy compared to those with S-ICD (32.7 vs 14.5 therapies per 100 patient-years, respectively; P <.001), driven by a high incidence of ATP therapy in the TV-ICD group, which accounted for >67% of therapies delivered. Shock incidence was similar between groups, both in the general and the matched cohorts. CONCLUSION: Patients with HCM and S-ICD had a significantly lower therapy rate than patients with TV-ICD without difference in shock therapy, suggesting potentially unnecessary ATP therapy. Empirical ATP programming in patients with HCM may be unbeneficial.


Cardiomyopathy, Hypertrophic , Defibrillators, Implantable , Adenosine Triphosphate , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Humans , Treatment Outcome
6.
J Interv Card Electrophysiol ; 63(1): 97-101, 2022 Jan.
Article En | MEDLINE | ID: mdl-33543350

PURPOSE: Catheter ablation procedures for atrial fibrillation (AF) were significantly curtailed during the peak of coronavirus disease 2019 (COVID-19) pandemic to conserve healthcare resources and limit exposure. There is little data regarding peri-procedural outcomes of medical procedures during the COVID-19 pandemic. We enacted protocols to safely reboot AF ablation while limiting healthcare resource utilization. We aimed to evaluate acute and subacute outcomes of protocols instituted for reboot of AF ablation during the COVID-19 pandemic. METHODS: Perioperative healthcare utilization and acute procedural outcomes were analyzed for consecutive patients undergoing AF ablation under COVID-19 protocols (2020 cohort; n=111) and compared to those of patients who underwent AF ablation during the same time period in 2019 (2019 cohort; n=200). Newly implemented practices included preoperative COVID-19 testing, selective transesophageal echocardiography (TEE), utilization of venous closure, and same-day discharge when clinically appropriate. RESULTS: Pre-ablation COVID-19 testing was positive in 1 of 111 patients. There were 0 cases ablation-related COVID-19 transmission and 0 major complications in either cohort. Pre-procedure TEE was performed in significantly fewer 2020 cohort patients compared to the 2019 cohort patients (68.4% vs. 97.5%, p <0.001, respectively) despite greater prevalence of persistent arrhythmia in the 2020 cohort. Same-day discharge was achieved in 68% of patients in the 2020 cohort, compared to 0% of patients in the 2019 cohort. CONCLUSIONS: Our findings demonstrate the feasibility of safe resumption of complex electrophysiology procedures during the COVID-19 pandemic, reducing healthcare utilization and maintaining quality of care. Protocols instituted may be generalizable to other types of procedures and settings.


Atrial Fibrillation , COVID-19 , Catheter Ablation , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , COVID-19 Testing , Humans , Pandemics , SARS-CoV-2 , Treatment Outcome
7.
J Cardiovasc Electrophysiol ; 33(2): 209-217, 2022 02.
Article En | MEDLINE | ID: mdl-34911157

INTRODUCTION: Prior studies have shown that addition of posterior wall isolation (PWI) may reduce atrial fibrillation recurrence in patients with persistent atrial fibrillation. No data on PWI in paroxysmal AF (pAF) patients with normal left atrial voltage is available, to date. OBJECTIVE: This study sought to evaluate the efficacy of PWI in addition to pulmonary vein isolation (PVI) in patients presenting with pAF and normal left atrial voltage. METHODS: Consecutive patient registry analysis was performed on all patients with pAF and normal left atrial voltage undergoing initial radiofrequency ablation from November 1, 2018 to November 15, 2019. Primary endpoint was recurrence of atrial arrhythmia including AF, atrial tachycardia (AT), or atrial flutter (AFL). RESULTS: A total of 321 patients were studied, 214 in the PVI group and 107 in the PWI + PVI group. Recurrence of any atrial arrhythmia occurred in 18.2% of patients in the PVI group and 16.8% in the PVI + PWI cohort (p = 0.58). At 1 year, recurrence was 14.0% in the PVI group and 15.0% in the PWI + PVI group (p = 0.96). There was a lower AT/AFL recurrence in the PVI + PWI group, not reaching significance (3.7% in the PWI + PVI group vs. 7.9% in PVI group, p = 0.31). Need for carina lesions predicted recurrence in the PVI-only group. CONCLUSIONS: Addition of PWI to PVI in pAF patients undergoing their first ablation did not reduce the frequency of atrial arrhythmia recurrence. This warrants further study in a prospective trial.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
8.
Int J Cardiol Heart Vasc ; 37: 100908, 2021 Dec.
Article En | MEDLINE | ID: mdl-34765721

BACKGROUND: There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes. METHODS: Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method. Incidence was compared by device indication, diagnosis type and device type. Cox-regression analysis was used to identify predictors of appropriate shock and device complication. RESULTS: 123 patients with a mean follow up of 6.4 ± 4.8 years were included. The incidence of first appropriate shock was 56.52% vs 24.44%, p < 0.05 for cardiomyopathy and channelopathy patients, despite similar ejection fraction (61% vs 60%, p = 0.6). The incidence of first inappropriate shock was 13.46% vs 56.25%, p < 0.01 for single vs. multi-lead devices. The incidence of first lead complication was higher for multi-lead vs. single lead devices, 43.75% vs. 17.31%, p = 0.04. Patients with an ICD for secondary prevention were more likely to receive an appropriate shock than those with primary prevention indication (HR 2.21, CI 1.07-4.56, p = 0.03). Multi-lead devices were associated with higher risk of inappropriate shock (HR 3.99, CI 1.27-12.52, p = 0.02), with similar appropriate shock risk compared to single lead devices. In 26.5% of patients with dual chamber devices, atrial sensing or pacing was not utilized. CONCLUSION: The rate of appropriate therapies and ICD complications in patients with inherited arrhythmia is high, particularly in cardiomyopathies with multi-lead devices. Risk-benefit ratio should be carefully considered when assessing the indication and type of device in this population.

9.
Heart Rhythm ; 18(12): 2110-2114, 2021 12.
Article En | MEDLINE | ID: mdl-34517119

BACKGROUND: More than 3 million cardiovascular implantable electronic devices (CIEDs) are implanted annually. There are minimal data regarding the timing of diagnosis of acute complications after implantation. It remains unclear whether patients can be safely discharged less than 24 hours postimplantation. OBJECTIVE: The purpose of this study was to determine the precise timing of acute complication diagnosis after CIED implantation and optimal timing for same-day discharge. METHODS: A retrospective cohort analysis of adults 18 years or older who underwent CIED implantation at a large urban quaternary care medical center between June 1, 2015, and March 30, 2020, was performed. Standard of care included overnight observation and chest radiography 6 and 24 hours postprocedure. Medical records were reviewed for the timing of diagnosis of acute complications. Acute complications included pneumothorax, hemothorax, pericardial effusion, lead dislodgment, and implant site hematoma requiring surgical intervention. RESULTS: A total of 2421 patients underwent implantation. Pericardial effusion or cardiac tamponade was diagnosed in 13 patients (0.53%), pneumothorax or hemothorax in 19 patients (0.78%), lead dislodgment in 11 patients (0.45%), and hematomas requiring surgical intervention in 5 patients (0.2%). Of the 48 acute complications, 43 (90%) occurred either within 6 hours or more than 24 hours after the procedure. Only 3 acute complications identified between 6 and 24 hours required intervention during the index hospitalization (0.12% of all cases). CONCLUSION: Most acute complications are diagnosed either within the first 6 hours or more than 24 hours after implantation. With rare exception, patients can be considered for discharge after 6 hours of appropriate monitoring.


Cardiac Tamponade , Defibrillators, Implantable/adverse effects , Early Medical Intervention , Hematoma , Hemothorax , Pacemaker, Artificial/adverse effects , Postoperative Complications , Prosthesis Implantation , Aged , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Cardiac Tamponade/epidemiology , Cardiac Tamponade/therapy , Clinical Observation Units/statistics & numerical data , Early Diagnosis , Early Medical Intervention/methods , Early Medical Intervention/standards , Early Medical Intervention/statistics & numerical data , Female , Hematoma/epidemiology , Hematoma/therapy , Hemothorax/epidemiology , Hemothorax/therapy , Humans , Male , Postoperative Complications/classification , Postoperative Complications/diagnosis , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Prosthesis Implantation/methods , Radiography, Thoracic/methods , Retrospective Studies , Standard of Care , Time-to-Treatment/organization & administration
10.
Expert Rev Med Devices ; 18(6): 505-512, 2021 Jun.
Article En | MEDLINE | ID: mdl-34323128

Introduction: Heart failure (HF) is a major cause of morbidity and mortality throughout the world. Despite the significant progress in the prevention and treatment of HF, mortality rates still remain high. Device therapy for HF includes cardiac resynchronization therapy (CRT) and the use of an implantable cardioverter-defibrillator (ICD). Recently, a new device therapy for the treatment of HF became available, called cardiac contractility modulation (CCM). CCM is a new device therapy for patients with HF who do not qualify for CRT. It is implanted in a minimally invasive manner to improve the patient's morbidity. Optimizer Smart System is a new device that delivers CCM therapy.Areas covered: We review the function of the Optimizer Smart System, the data from the recent clinical trials, and discuss its efficacy and future projections in the treatment for HF.Expert opinion: CCM therapy provided with the Optimizer® Smart System is safe, feasible, and applicable to a wide range of patients with HF. To demonstrate the effectiveness of the Optimizer Smart System's use merits further large multicenter randomized controlled trials.


Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Chronic Disease , Heart Failure/therapy , Humans , Multicenter Studies as Topic , Myocardial Contraction , Treatment Outcome
11.
Resuscitation ; 162: 171-179, 2021 05.
Article En | MEDLINE | ID: mdl-33652119

BACKGROUND: The prolongation in QT interval typically observed following cardiac arrest is considered to be multifactorial and induced by external triggers such as hypothermia therapy and exposure to antiarrhythmic medications. OBJECTIVE: To evaluate the corrected QT interval (QTc) dynamics in the first 10 days following cardiac arrest with respect to the etiology of arrest, hypothermia and QT prolonging medications. METHODS: We enrolled 104 adult survivors of cardiac arrest, where daily ECG was available for at least 3 days. We followed their QT and QRS intervals for the first 10 days of hospitalization. We used both Bazett and Fridericia formulas to correct for heart rate. For patients with QRS < 120 we analyzed the QTc interval (n = 90) and for patients with QRS > 120 ms we analyzed the JTc (n = 104) vs. including only the narrow QRS samples (n = 89). We stratified patients by 3 groups: (1) presence of ischemic heart disease (IHD) (2) treatment with hypothermia protocol, and (3) treatment with QTc prolonging medications. Additionally, genetic information obtained during hospitalization was analyzed. RESULTS: QTc and JTc intervals were significantly prolonged in the first 6 days. Maximal QTc/JTc prolongation was observed in day 2 (QTcB = 497 ± 55). There were no differences in daily QTc/JTc and QRS intervals in the first 2 days post arrest between patients with or without hypothermia induction but such difference was found with QT prolonging medications. All subgroups demonstrated significantly prolonged QTc/JTc interval regardless of the presence of IHD, hypothermia protocol or QTc prolonging medication exposure. Our results were consistent for both Bazetts' and Frediricia correction and for any QRS duration. Prolongation of the JTcB beyond 382 ms after day 3 predicted sustained QTc/JTc prolongation beyond day 6 with an ROC of 0.78. CONCLUSIONS: QTc/JTc interval is significantly and independently prolonged post SCA, regardless of known QT prolonging triggers. Normalization of the QTc post cardiac arrest should be expected only after day 6 of hospitalization. Assessment of the QTc for adjudication of the etiology of arrest or for monitoring the effect of QT prolonging medications may be unreliable.


Heart Arrest , Long QT Syndrome , Adult , Anti-Arrhythmia Agents , Electrocardiography , Heart Arrest/complications , Heart Arrest/therapy , Heart Rate , Humans , Long QT Syndrome/etiology
13.
Front Cardiovasc Med ; 8: 636073, 2021.
Article En | MEDLINE | ID: mdl-33604358

Background: The COVID-19 pandemic has resulted in worldwide morbidity at unprecedented scale. Troponin elevation is a frequent laboratory finding in hospitalized patients with the disease, and may reflect direct vascular injury or non-specific supply-demand imbalance. In this work, we assessed the correlation between different ranges of Troponin elevation, Electrocardiographic (ECG) abnormalities, and mortality. Methods: We retrospectively studied 204 consecutive patients hospitalized at NYU Langone Health with COVID-19. Serial ECG tracings were evaluated in conjunction with laboratory data including Troponin. Mortality was analyzed in respect to the degree of Troponin elevation and the presence of ECG changes including ST elevation, ST depression or T wave inversion. Results: Mortality increased in parallel with increase in Troponin elevation groups and reached 60% when Troponin was >1 ng/ml. In patients with mild Troponin rise (0.05-1.00 ng/ml) the presence of ECG abnormality and particularly T wave inversions resulted in significantly greater mortality. Conclusion: ECG repolarization abnormalities may represent a marker of clinical severity in patients with mild elevation in Troponin values. This finding can be used to enhance risk stratification in patients hospitalized with COVID-19.

14.
Am J Cardiol ; 129: 25-29, 2020 08 15.
Article En | MEDLINE | ID: mdl-32600783

Occult atrial fibrillation (AF) can be the underlying cause for cryptogenic stroke (CS). Implantable loop recorders (ILRs) have become an important tool for long-term arrhythmia monitoring in CS patients. Office-based ILR implantation by nonelectrophysiologist physicians is increasingly common. To report the real world diagnostic yield and accuracy of remote ILR monitoring in high risk CS patients, we retrospectively analyzed 145 consecutive patients with CS who underwent ILR implantation between October 2014 and October 2018 at New York University Langone Health. A certified device technician and an electrophysiologist adjudicated all transmissions. The yield and accuracy of Reveal LINQ Intra Cardiac Monitor (ICM), a fourth generation device, was compared to that of TruRhythm Detection algorithm (fifth generation device). AF was diagnosed in 17 patients (12%) over a mean follow-up of 28 ± 12 months. The median time to diagnosis was 7.4 ± 21.3 months. A total of 1,637 remote transmissions (scheduled- and auto-triggered alerts: 756; patient-triggered: 881) were adjudicated. The positive predictive value for AF episodes in the scheduled interrogations increased from 4% in the Reveal LINQ ICM to 16% in the TruRhythm LINQ. Of 881 patient-triggered transmissions, none were found to be true positive. In the Reveal LINQ ICM, for scheduled transmissions, primary causes of false positive (FP) were atrial ventricular premature complexes (80%). In the TruRhythm LINQ, for scheduled transmissions, primary cause of FP were T-wave over-sensing (87%). In conclusion, the real world diagnostic yield of ILR for patients with CS remains suboptimal, with at least 84% of AF alerts being FP. Patient-riggered events did not correlate with arrhythmia and the necessity of patient triggering in this population should be questioned. Expert interpretation of recordings is critical to assure accurate diagnosis.


Algorithms , Atrial Fibrillation/diagnosis , Electrocardiography, Ambulatory/methods , Prostheses and Implants , Stroke/etiology , Aged , Aged, 80 and over , Atrial Fibrillation/complications , Electrocardiography, Ambulatory/instrumentation , Female , Humans , Male , Middle Aged , Retrospective Studies
16.
Heart Rhythm ; 17(9): 1425-1433, 2020 09.
Article En | MEDLINE | ID: mdl-32407884

Background: There is no known effective therapy for patients with coronavirus disease 2019 (COVID-19). Initial reports suggesting the potential benefit of hydroxychloroquine/azithromycin (HY/AZ) have resulted in massive adoption of this combination worldwide. However, while the true efficacy of this regimen is unknown, initial reports have raised concerns about the potential risk of QT interval prolongation and induction of torsade de pointes (TdP). Objective: The purpose of this study was to assess the change in corrected QT (QTc) interval and arrhythmic events in patients with COVID-19 treated with HY/AZ. Methods: This is a retrospective study of 251 patients from 2 centers who were diagnosed with COVID-19 and treated with HY/AZ. We reviewed electrocardiographic tracings from baseline and until 3 days after the completion of therapy to determine the progression of QTc interval and the incidence of arrhythmia and mortality. Results: The QTc interval prolonged in parallel with increasing drug exposure and incompletely shortened after its completion. Extreme new QTc interval prolongation to >500 ms, a known marker of high risk of TdP, had developed in 23% of patients. One patient developed polymorphic ventricular tachycardia suspected as TdP, requiring emergent cardioversion. Seven patients required premature termination of therapy. The baseline QTc interval of patients exhibiting extreme QTc interval prolongation was normal. Conclusion: The combination of HY/AZ significantly prolongs the QTc interval in patients with COVID-19. This prolongation may be responsible for life-threatening arrhythmia in the form of TdP. This risk mandates careful consideration of HY/AZ therapy in light of its unproven efficacy. Strict QTc interval monitoring should be performed if the regimen is given.


Azithromycin/therapeutic use , Betacoronavirus , Coronavirus Infections/drug therapy , Hydroxychloroquine/therapeutic use , Long QT Syndrome/epidemiology , Pneumonia, Viral/drug therapy , Torsades de Pointes/epidemiology , Aged , Anti-Bacterial Agents/therapeutic use , Antimalarials/therapeutic use , COVID-19 , Coronavirus Infections/complications , Female , Humans , Incidence , Male , Middle Aged , Pandemics , Retrospective Studies , SARS-CoV-2 , COVID-19 Drug Treatment
17.
Heart Rhythm ; 17(5 Pt A): 721-727, 2020 05.
Article En | MEDLINE | ID: mdl-31978595

BACKGROUND: Increased peak luminal esophageal temperature (LET) is associated with increased risk of esophageal injury after left atrial posterior wall (LAPW) ablation. The magnitude, distribution, and risk factors of LET increase with high-power short-duration (HPSD) LAPW ablation are not well understood. OBJECTIVE: The purpose of this study was to describe the spatial and temporal characteristics of LET changes associated with HPSD LAPW radiofrequency (RF) ablation. METHODS: LET was sampled at 20 Hz using a 12-point esophageal temperature monitor (CIRCA S-CATH; Circa Scientific, Inc) in 16 patients undergoing LAPW ablation. Esophageal temperature sensor position and lesion locations were recorded using an electroanatomic mapping system with fluoroscopic integration (CARTO 3, CARTOUNIVU; Biosense Webster, Inc). Point-by-point LAPW ablation was performed at 50 W for 6 seconds. The first 20 LAPW lesions were individually analyzed in each patient. RESULTS: LET increase ≥4°C (8 lesions: max LET 5.8°C), 2°-4°C (34 lesions), and 1°-2°C (58 lesions) occurred at 9 ± 2 mm, 8 ± 2 mm, and 13 ± 2 mm from sensors, respectively. Lesions placed >20 mm from a temperature sensor did not result in an LET increase ≥2°C. Temperature resolution to within 1°C of baseline occurred ∼60 seconds after cessation of RF application. Consecutive lesions resulting in additive heating of at least 1°C occurred in 17 lesion pairs with an interlesion distance of 9 ± 4 mm and interlesion time of 21 ± 4 seconds. CONCLUSION: HPSD LAPW ablation can result in severe esophageal temperature increases. Significant LET increase will be undetected when lesions are >20 mm away from a temperature sensor. Additive LET increase was observed with consecutive lesions placed <20 mm apart within 60 seconds.


Atrial Fibrillation/surgery , Body Temperature/physiology , Esophagus/physiopathology , Monitoring, Intraoperative/methods , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/physiopathology , Catheter Ablation/methods , Female , Follow-Up Studies , Humans , Male , Retrospective Studies , Risk Factors , Time Factors
18.
J Atr Fibrillation ; 13(3): 2373, 2020.
Article En | MEDLINE | ID: mdl-34950311

BACKGROUND: Improved catheter stability is associated with decreased arrhythmia recurrence after atrial fibrillation (AF) ablation. Recently, atrial voltage mapping in AF was demonstrated to correlate better with scar as compared to mapping in sinus rhythm (SR). However, it is unknown whether ablation of persistent AF in sinus rhythm with atrial pacing or in atrial fibrillation with ventricular pacing results in differences in catheter stability or arrhythmia recurrence. METHODS: We analyzed 53 consecutive patients undergoing first-time persistent AF ablation with pulmonary vein and posterior wall isolation: 27 were cardioverted, mapped, and ablated in sinus rhythm with atrial pacing, and 26 were mapped and ablated in AF with ventricular pacing. Ablation data was extracted from the mapping system and analyzed using custom MATLAB software to determine high-frequency (60Hz) catheter excursion as a novel metric for catheter spatial stability. RESULTS: There was no difference in catheter stability as assessed by maximal catheter excursion, mean catheter excursion, or contact force variability between the atrial-paced and ventricular-paced patients. Ventricular-paced patients had significantly greater mean contact force as compared to atrial-paced patients. Contact-force variability demonstrated poor correlation with catheter excursion. One year arrhythmia-free survival was similar between the atrial paced and ventricular paced patients. CONCLUSIONS: For patients with persistent AF, ablation in AF with ventricular pacing results in similar catheter stability and arrhythmia recurrence as compared to cardioversion and ablation in sinus rhythm with atrial pacing. Given the improved fidelity of mapping in AF, mapping and ablating during AF with ventricular pacing may be preferred.

19.
Org Lett ; 15(5): 1136-9, 2013 Mar 01.
Article En | MEDLINE | ID: mdl-23427861

Hydrophosphination of secondary propargylic alcohols generates phosphine-containing allylic alcohols that undergo facile [2,3]-sigmatropic rearrangements with chlorophosphines, furnishing highly enantioenriched, crystalline diphosphine monoxides. The configuration at the newly formed stereocenter is opposite to that expected based on prior studies, and an ab initio computational evaluation of the possible transition states was performed to help explain the stereochemical course of the reaction.


Organophosphorus Compounds/chemical synthesis , Propanols/chemistry , Catalysis , Combinatorial Chemistry Techniques , Molecular Structure , Organophosphorus Compounds/chemistry , Stereoisomerism
20.
Org Lett ; 15(5): 1132-5, 2013 Mar 01.
Article En | MEDLINE | ID: mdl-23427869

The first uncatalyzed hydrophosphinations of propargylic amines and alcohols with phosphine- borane complexes are described. The reactions proceed at ambient temperature or below without the use of protecting groups or the need to handle pyrophoric secondary phosphines, furnishing air-stable phosphineborane-amines and alcohols in good yields. Utilization of chiral propargylic substrates and unsymmetrical secondary phosphineboranes leads to diastereomeric P-chiral products that can be separated by fractional crystallization or chromatography. Initial applications of these new P-X species to asymmetric catalysis are detailed.


Alkynes/chemistry , Amines/chemistry , Boranes/chemistry , Phosphines/chemistry , Propanols/chemistry , Catalysis , Molecular Structure , Stereoisomerism
...