Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 59
1.
EJVES Vasc Forum ; 61: 92-98, 2024.
Article En | MEDLINE | ID: mdl-38455254

Objective: Thoracic outlet syndrome (TOS) is a rare disorder mostly seen in younger individuals. Although patient wellbeing is relevantly impaired, it often takes a long time before the diagnosis is made. Digital subtraction angiography (DSA) is routinely used despite its radiation exposure, which is a major concern in this young patient population. Moreover, DSA offers limited opportunities for functional assessment. By contrast, ultrasonography is widely accessible without causing radiation exposure and allows for flexible functional assessment. The main goal of the study was to investigate whether ultrasound (US) was a viable alternative to DSA in diagnosing arterial TOS (aTOS). Methods: Patients, referred to a tertiary centre for evaluation of suspected TOS, were recruited into the study. DSA was routinely performed with the patient's arms both in the raised (abducted) and neutral (adducted) position. Two vascular surgeons and two radiologists assessed the resulting images for the presence of aTOS. Additionally, two examiners performed US according to a standardised protocol. The reference for presence of aTOS was the DSA based interdisciplinary vascular conference consensus. Inter-rater agreement and latent class analysis (LCA) were performed between assessors and diagnostic methods. Results: Fifty one consecutive patients (two thirds female) aged 39.3 ± 13.0 years were included within 11 months. US agreement was excellent at 0.94 (0.841-0.980), DSA agreement for vascular surgeons was good at 0.779 (0.479-1.000), whereas it was moderate at 0.546 (0.046-1.000) for radiologists. Results suggest that DSA is untenable as the gold standard for aTOS diagnosis. In LCA, US was shown to be a reliable diagnostic tool for the detection of aTOS. Conclusion: US examination is a valid test for the detection of haemodynamically relevant compression of arteries in the diagnostic work up of aTOS using a standardised protocol. The role of DSA as the gold standard should be reviewed and needs to be reconsidered.

2.
Open Heart ; 10(2)2023 Oct.
Article En | MEDLINE | ID: mdl-37793674

OBJECTIVE: To determine the diagnostic yield of a 'high' N-terminal pro-brain natriuretic peptide (NT-proBNP) in patients with suspected heart failure (HF) referred from primary to secondary care. METHODS: In this retrospective study, cardiac diagnoses were quantified in consecutive patients with an NT-proBNP>400 ng/L referred from primary care centres to a specialist HF service. RESULTS: Among 654 consecutive patients (age: 78.5±9.72 years; 45.9% men; left ventricular ejection fraction (LVEF): 55.4±12.5% (mean±SD)), the primary diagnoses were: valvular disease (39.4%), HF (29.2%; 13.3% with LVEF<40%) and atrial fibrillation (AF; 17.3%). In terms of primary or secondary diagnoses, 68% of patients had valve disease, 46.9% had AF and 29.2% had HF. A cardiac diagnosis was made in 85.9%. In multivariable analyses, NT-proBNP predicted HF with LVEF<40% (OR: 10.2, 95% CI: 5.63 to 18.3) and HF with any LVEF (OR: 6.13, 95% CI: 3.79 to 9.93). In canonical linear discriminant analyses, NT-proBNP correctly identified 54.5% of patients with HF. The remainder were misclassified as valvular disease, AF or no cardiac diagnosis. CONCLUSION: Among patients with an NT-proBNP>400 ng/L referred through a primary care HF pathway, most patients had valve disease or AF rather than HF. NT-proBNP cannot discriminate among HF, valve disease and AF. On this basis, NT-proBNP may be best employed in detecting cardiac disease in general rather than HF per se.


Heart Failure , Heart Valve Diseases , Male , Humans , Aged , Aged, 80 and over , Female , Stroke Volume , Retrospective Studies , Ventricular Function, Left , Referral and Consultation
3.
Europace ; 25(6)2023 06 02.
Article En | MEDLINE | ID: mdl-37265253

AIMS: The past decade has seen an increased delivery of cardiac resynchronization therapy (CRT) for patients with heart failure (HF). We explored whether clinical outcomes after CRT have changed from the perspective of an entire public healthcare system. METHODS AND RESULTS: A national database covering the population of England (56.3 million in 2019) was used to explore clinical outcomes after CRT from 2010 to 2019. A total of 64 698 consecutive patients (age 71.4 ± 11.7 years; 74.8% male) underwent CRT-defibrillation [n = 32 313 (49.7%)] or CRT-pacing [n = 32 655 (50.3%)] implantation. From 2010-2011 to 2018-2019, there was a 76% increase in CRT implantations. During the same period, the proportion of patients with hypertension (59.6-73.4%), diabetes (26.5-30.8%), and chronic kidney disease (8.62-22.5%) increased, as did the Charlson comorbidity index (CCI ≥ 3 from 20.0% to 25.1%) (all P < 0.001). Total mortality decreased at 30 days (1.43-1.09%) and 1 year (9.51-8.13%) after implantation (both P < 0.001). At 2 years, total mortality [hazard ratio (HR): 0.72; 95% confidence interval (CI) 0.69-0.76] and total mortality or HF hospitalization (HR: 0.59; 95% CI 0.57-0.62) decreased from 2010-2011 to 2018-2019, after correction for age, race, sex, device type (CRT-defibrillation or pacing), comorbidities (hypertension, diabetes, chronic kidney disease, and myocardial infarction), or the CCI (HR: 0.81; 95% CI 0.77-0.85). CONCLUSIONS: From the perspective of an entire public health system, survival has improved and HF hospitalizations have decreased after CRT implantation over the past decade. This prognostic improvement has occurred despite an increasing comorbidity burden.


Cardiac Resynchronization Therapy , Defibrillators, Implantable , Diabetes Mellitus , Heart Failure , Hypertension , Renal Insufficiency, Chronic , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Female , Cardiac Resynchronization Therapy/adverse effects , Treatment Outcome , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Prognosis , Hypertension/diagnosis , Hypertension/epidemiology , Hypertension/therapy , Renal Insufficiency, Chronic/therapy
4.
Europace ; 25(5)2023 05 19.
Article En | MEDLINE | ID: mdl-36944529

AIMS: The optimum timing of cardiac resynchronization therapy (CRT) implantation is unknown. We explored long-term outcomes after CRT in relation to the time interval from a first heart failure hospitalization (HFH) to device implantation. METHODS AND RESULTS: A database covering the population of England (56.3 million in 2019) was used to quantify clinical outcomes after CRT implantation in relation to first HFHs. From 2010 to 2019, 64 968 patients [age: 71.4 ± 11.7 years; 48 606 (74.8%) male] underwent CRT implantation, 57% in the absence of a previous HFH, 12.9% during the first HFH, and 30.1% after ≥1 HFH. Over 4.54 (2.80-6.71) years [median (interquartile range); 272 989 person-years], the time in years from the first HFH to CRT implantation was associated with a higher risk of total mortality [hazard ratio (HR); 95% confidence intervals (95% CI)] (1.15; 95% CI 1.14-1.16, HFH (HR: 1.26; 95% CI 1.24-1.28), and the combined endpoint of total mortality or HFH (HR: 1.19; 95% CI 1.27-1.20) than CRT in patients with no previous HFHs, after co-variate adjustment. Total mortality (HR: 1.67), HFH (HR: 2.63), and total mortality or HFH (HR: 1.92) (all P < 0.001) were highest in patients undergoing CRT ≥2 years after the first HFH. CONCLUSION: In this study of a healthcare system covering an entire nation, delays from a first HFH to CRT implantation were associated with progressively worse long-term clinical outcomes. The best clinical outcomes were observed in patients with no previous HFH and in those undergoing CRT implantation during the first HFH. CONDENSED ABSTRACT: The optimum timing of CRT implantation is unknown. In this study of 64 968 consecutive patients, delays from a first heart failure hospitalization (HFH) to CRT implantation were associated with progressively worse long-term clinical outcomes. Each year from a first HFH to CRT implantation was associated with a 21% higher risk of total mortality and a 34% higher risk of HFH. The best outcomes after CRT were observed in patients with no previous HFHs and in those undergoing implantation during their first HFH.


Cardiac Resynchronization Therapy , Heart Failure , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Female , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Treatment Outcome , Cardiac Resynchronization Therapy Devices , Heart Failure/diagnosis , Heart Failure/therapy , England
5.
Eur J Heart Fail ; 25(2): 274-283, 2023 02.
Article En | MEDLINE | ID: mdl-36404397

AIMS: Excessive prolongation of PR interval impairs coupling of atrio-ventricular (AV) contraction, which reduces left ventricular pre-load and stroke volume, and worsens symptoms. His bundle pacing allows AV delay shortening while maintaining normal ventricular activation. HOPE-HF evaluated whether AV optimized His pacing is preferable to no-pacing, in a double-blind cross-over fashion, in patients with heart failure, left ventricular ejection fraction (LVEF) ≤40%, PR interval ≥200 ms and either QRS ≤140 ms or right bundle branch block. METHODS AND RESULTS: Patients had atrial and His bundle leads implanted (and an implantable cardioverter-defibrillator lead if clinically indicated) and were randomized to 6 months of pacing and 6 months of no-pacing utilizing a cross-over design. The primary outcome was peak oxygen uptake during symptom-limited exercise. Quality of life, LVEF and patients' holistic symptomatic preference between arms were secondary outcomes. Overall, 167 patients were randomized: 90% men, 69 ± 10 years, QRS duration 124 ± 26 ms, PR interval 249 ± 59 ms, LVEF 33 ± 9%. Neither peak oxygen uptake (+0.25 ml/kg/min, 95% confidence interval [CI] -0.23 to +0.73, p = 0.3) nor LVEF (+0.5%, 95% CI -0.7 to 1.6, p = 0.4) changed with pacing but Minnesota Living with Heart Failure quality of life improved significantly (-3.7, 95% CI -7.1 to -0.3, p = 0.03). Seventy-six percent of patients preferred His bundle pacing-on and 24% pacing-off (p < 0.0001). CONCLUSION: His bundle pacing did not increase peak oxygen uptake but, under double-blind conditions, significantly improved quality of life and was symptomatically preferred by the clear majority of patients. Ventricular pacing delivered via the His bundle did not adversely impact ventricular function during the 6 months.


Cardiac Resynchronization Therapy , Heart Failure , Male , Humans , Female , Bundle of His , Cross-Over Studies , Stroke Volume , Quality of Life , Exercise Tolerance , Ventricular Function, Left , Oxygen , Treatment Outcome , Cardiac Pacing, Artificial/methods , Cardiac Resynchronization Therapy/methods , Electrocardiography/methods
6.
Pacing Clin Electrophysiol ; 46(2): 114-124, 2023 02.
Article En | MEDLINE | ID: mdl-36385259

BACKGROUND: Implantable cardioverter defibrillators (ICDs) offer effective therapy for the prevention of sudden cardiac death (SCD) due to ventricular arrhythmias. However, inappropriate shocks have detrimental effects on survival and quality of life. The addition of hemodynamic monitoring may be useful in discriminating clinically important ventricular arrhythmias. OBJECTIVE: In this study, we assess the ability of laser Doppler flowmetry to assess the hemodynamic effect of paced atrial and ventricular arrhythmias using mean arterial blood pressure as the reference. METHODS: In this acute human study in patients undergoing an elective electrophysiological study, laser Doppler flowmetry, arterial blood pressure, and surface ECG were acquired during high-rate atrial and ventricular pacing to simulate supraventricular and ventricular tachycardias. RESULTS: Arterial blood pressure and laser Doppler flow signals correlated well during atrial and ventricular pacing (rho = 0.694, p < .001). The hemodynamic impairment detected by both methods was greater during ventricular pacing than atrial pacing (-1.0% vs. 19.0%, p < .001). Laser Doppler flowmetry performed better than rate alone to identify hemodynamic impairments. CONCLUSION: In this acute study, laser Doppler flowmetry tissue perfusion served as a good surrogate measure for arterial pressure, which could be incorporated into future ICDs.


Atrial Fibrillation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Atrial Fibrillation/therapy , Quality of Life , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Death, Sudden, Cardiac/prevention & control , Lasers
7.
Pacing Clin Electrophysiol ; 45(9): 1075-1084, 2022 09.
Article En | MEDLINE | ID: mdl-35899803

BACKGROUND: Right ventricular (RV) dysfunction has been linked to a poor response to cardiac resynchronization therapy (CRT). We sought to determine whether cardiovascular magnetic resonance (CMR)-derived measures of RV function influence clinical outcomes after CRT. METHODS: In this retrospective study, we used CMR to assess pre-implant RV volumes and RV ejection fraction (RVEF) in relation to clinical outcomes after CRT implantation. RESULTS: Among 243 patients (age: 70.3 ± 10.8 years [mean ± SD]; 68.7% male; 121 [49.8%]) with ischemic cardiomyopathy and 122 (50.2%) with nonischemic cardiomyopathy, 141 (58%) after CRT-defibrillation (CRT-D) and 102 (42%) after CRT-pacing (CRT-P), 101 (41.6.0%) patients died, 61 (25.1%) from cardiac causes and 24 (9.88%) from noncardiac causes, over 5.87 years (median; interquartile range: 4.35-7.73). Two (0.82%) patients underwent cardiac transplantation and four (1.64%) had a left ventricular assist device (LVAD). A total of 41 (16.9%) met the composite endpoint of sudden cardiac death (SCD), ventricular tachycardia, or ventricular fibrillation. In univariate analyses, no measure of RV function was associated with total mortality or the arrhythmic endpoint. RVEF was associated with cardiac mortality on univariate analyses (HR per 10%: 0.82, 95% CI 0.70-0.96), but not on multivariate analyses that included left ventricular ejection fraction. CONCLUSIONS: There is no relationship between measures of RV function, such as RV volumes and RVEF, and the long-term clinical outcome of CRT. These findings indicate that such measures should not be considered in patient selection.


Cardiac Resynchronization Therapy , Cardiomyopathies , Heart Failure , Ventricular Dysfunction, Right , Aged , Aged, 80 and over , Cardiomyopathies/complications , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/therapy , Female , Humans , Magnetic Resonance Spectroscopy , Male , Middle Aged , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Dysfunction, Right/therapy , Ventricular Function, Left , Ventricular Function, Right
8.
Front Cardiovasc Med ; 9: 901267, 2022.
Article En | MEDLINE | ID: mdl-35647062

The aim of the SYNSEQ (Left Ventricular Synchronous vs. Sequential MultiSpot Pacing for CRT) study was to evaluate the acute hemodynamic response (AHR) of simultaneous (3P-MPP syn) or sequential (3P-MPP seq) multi-3-point-left-ventricular (LV) pacing vs. single point pacing (SPP) in a group of patients at risk of a suboptimal response to cardiac resynchronization therapy (CRT). Twenty five patients with myocardial scar or QRS ≤ 150 or the absence of LBBB (age: 66 ± 12 years, QRS: 159 ± 12 ms, NYHA class II/III, LVEF ≤ 35%) underwent acute hemodynamic assessment by LV + dP/dtmax with a variety of LV pacing configurations at an optimized AV delay. The change in LV + dP/dt max (%ΔLV + dP/dt max) with 3P-MPP syn (15.6%, 95% CI: 8.8%-22.5%) was neither statistically significantly different to 3P-MPP seq (11.8%, 95% CI: 7.6-16.0%) nor to SPP basal (11.5%, 95% CI:7.1-15.9%) or SPP mid (12.2%, 95% CI:7.9-16.5%), but higher than SPP apical (10.6%, 95% CI:5.3-15.9%, p = 0.03). AHR (defined as a %ΔLV + dP/dt max ≥ 10%) varied between pacing configurations: 36% (9/25) for SPP apical, 44% (11/25) for SPP basal, 54% (13/24) for SPP mid, 56% (14/25) for 3P-MPP syn and 48% (11/23) for 3P-MPP seq.Fifteen patients (15/25, 60%) had an AHR in at least one pacing configuration. AHR was observed in 10/13 (77%) patients with a LBBB but only in 5/12 (42%) patients with a non-LBBB (p = 0.11). To conclude, simultaneous or sequential multipoint pacing compared to single point pacing did not improve the acute hemodynamic effect in a suboptimal CRT response population. Clinical Trial Registration: ClinicalTrials.gov, identifier: NCT02914457.

9.
J Am Coll Cardiol ; 79(7): 665-678, 2022 02 22.
Article En | MEDLINE | ID: mdl-35177196

BACKGROUND: Increasing evidence supports a link between myocardial fibrosis (MF) and ventricular arrhythmias. OBJECTIVES: The purpose of this study was to determine whether presence of myocardial fibrosis on visual assessment (MFVA) and gray zone fibrosis (GZF) mass predicts sudden cardiac death (SCD) and ventricular fibrillation/sustained ventricular tachycardia after cardiac implantable electronic device (CIED) implantation. METHODS: In this prospective study, total fibrosis and GZF mass, quantified using cardiovascular magnetic resonance, was assessed in relation to the primary endpoint of SCD and the secondary, arrhythmic endpoint of SCD or ventricular arrhythmias after CIED implantation. RESULTS: Among 700 patients (age 68.0 ± 12.0 years), 27 (3.85%) experienced a SCD and 121 (17.3%) met the arrhythmic endpoint over median 6.93 years (IQR: 5.82-9.32 years). MFVA predicted SCD (HR: 26.3; 95% CI: 3.7-3,337; negative predictive value: 100%). In competing risk analyses, MFVA also predicted the arrhythmic endpoint (subdistribution HR: 19.9; 95% CI: 6.4-61.9; negative predictive value: 98.6%). Compared with no MFVA, a GZF mass measured with the 5SD method (GZF5SD) >17 g was associated with highest risk of SCD (HR: 44.6; 95% CI: 6.12-5,685) and the arrhythmic endpoint (subdistribution HR: 30.3; 95% CI: 9.6-95.8). Adding GZF5SD mass to MFVA led to reclassification of 39% for SCD and 50.2% for the arrhythmic endpoint. In contrast, LVEF did not predict either endpoint. CONCLUSIONS: In CIED recipients, MFVA excluded patients at risk of SCD and virtually excluded ventricular arrhythmias. Quantified GZF5SD mass added predictive value in relation to SCD and the arrhythmic endpoint.


Cardiac Resynchronization Therapy/mortality , Death, Sudden, Cardiac/pathology , Defibrillators, Implantable , Myocardium/pathology , Ventricular Fibrillation/mortality , Ventricular Fibrillation/therapy , Aged , Aged, 80 and over , Cardiac Resynchronization Therapy/trends , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/trends , Female , Fibrosis , Follow-Up Studies , Humans , Magnetic Resonance Imaging, Cine/mortality , Magnetic Resonance Imaging, Cine/trends , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Ventricular Fibrillation/diagnostic imaging
10.
Europace ; 24(1): 31-39, 2022 01 04.
Article En | MEDLINE | ID: mdl-34379762

AIMS: To determine whether myocardial fibrosis and greyzone fibrosis (GZF) on cardiovascular magnetic resonance (CMR) is associated with ventricular arrhythmias in patients with coronary artery disease (CAD) and a left ventricular ejection fraction (LVEF) >35%. METHODS AND RESULTS: In this retrospective study of CAD patients, GZF mass using the 3SD method (GZF3SD) and total fibrosis mass using the 2SD method (TF2SD) on CMR were assessed in relation to the primary, combined endpoint of sudden cardiac death, ventricular tachycardia, ventricular fibrillation, or resuscitated cardiac arrest. Among 701 patients [age: 65.8 ± 12.3 years (mean ± SD)], 28 (3.99%) patients met the primary endpoint over 5.91 years (median; interquartile range 4.42-7.64). In competing risks analysis, a GZF3SD mass ≥5.0 g was strongly associated with the primary endpoint [subdistribution hazard ratio (sHR): 17.4 (95% confidence interval, CI 6.64-45.5); area under receiver operator characteristic curve (AUC): 0.85, P < 0.001]. A weaker association was observed for TF2SD mass ≥23 g [sHR 10.4 (95% CI 4.22-25.8); AUC: 0.80, P < 0.001]. The range of sHRs for GZF3SD mass (1-527) was wider than for TF2SD mass (1-37.6). CONCLUSIONS: In CAD patients with an LVEF >35%, GZF3SD mass was strongly associated with the arrhythmic endpoint. These findings hold promise for its use in identifying patients with CAD and an LVEF >35% at risk of arrhythmic events.


Magnetic Resonance Imaging, Cine , Ventricular Function, Left , Aged , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/pathology , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/pathology , Fibrosis , Humans , Middle Aged , Myocardium/pathology , Retrospective Studies , Stroke Volume
11.
Indian Pacing Electrophysiol J ; 22(1): 54-57, 2022.
Article En | MEDLINE | ID: mdl-34775047

Anti-tachycardia pacing (ATP) is frequently used to terminate ventricular tachycardia (VT), however it is not always successful and may accelerate VT requiring defibrillation. REVRAMP is a novel concept of ATP that involves delivering pacing at a faster rate than VT, but instead of abruptly terminating pacing after eight beats, pacing is gradually slowed until VT continues or normal rhythm is restored. In a pilot study we show that REVRAMP can restore normal rhythm, and that if REVRAMP is unsuccessful, VT is not accelerated.

13.
Europace ; 23(6): 928-936, 2021 06 07.
Article En | MEDLINE | ID: mdl-33778881

AIMS: The COVID-19 pandemic has led to a decline in hospitalizations for non-COVID-19-related conditions. We explored the impact of the COVID-19 pandemic on cardiac operations and interventions undertaken in England. METHODS AND RESULTS: An administrative database covering hospital activity for England, the Health Episodes Statistics, was used to assess a total of 286 697 hospitalizations for cardiac operations and interventions, as well as 227 257 hospitalizations for myocardial infarction (MI) and 453 799 for heart failure (HF) from 7 January 2019 to 26 July 2020. Over the 3 months of 'lockdown', total numbers and mean reductions in weekly rates [n (-%)], compared with the same time period in 2019, were: coronary artery bypass grafting [-2507 (-64%)]; percutaneous coronary intervention [-5245 (-28%)]; surgical [-1324 (-41%)] and transcatheter [-284 (-21%)] aortic valve replacement; mitral valve replacement; implantation of pacemakers [-6450 (-44%)], cardiac resynchronization therapy with [-356 (-42%)] or without [-491 (-46%)] defibrillation devices, and implantable cardioverter-defibrillators [-501 (-45%)]; atrial fibrillation ablation [-1902 (-83%)], and other ablations [-1712 (-64%)] (all P < 0.001). Over this period, there were 21 038 fewer procedures than in the reference period in 2019 (P < 0.001). These changes paralleled reductions in hospitalizations for MI [-10 794 (-27%)] and HF [-63 058 (-28%)] (both P < 0.001). CONCLUSIONS: The COVID-19 pandemic has led to substantial reductions in the number of cardiac operations and interventions undertaken. An alternative strategy for healthcare delivery to patients with cardiac conditions during the COVID-19 pandemic is urgently needed.


COVID-19 , Pandemics , Communicable Disease Control , England , Humans , SARS-CoV-2
14.
J Am Coll Cardiol ; 77(1): 29-41, 2021 01 05.
Article En | MEDLINE | ID: mdl-33413938

BACKGROUND: The "gray zone" of myocardial fibrosis (GZF) on cardiovascular magnetic resonance may be a substrate for ventricular arrhythmias (VAs). OBJECTIVES: The purpose of this study was to determine whether GZF predicts sudden cardiac death (SCD) and VAs (ventricular fibrillation or sustained ventricular tachycardia) in patients with coronary artery disease (CAD) and a wide range of left ventricular ejection fractions (LVEFs). METHODS: In this retrospective study of CAD patients, the presence of myocardial fibrosis on visual assessment (MFVA) and GZF mass in patients with MFVA were assessed in relation to SCD and the composite, arrhythmic endpoint of SCD or VAs. RESULTS: Among 979 patients (mean age [± SD]: 65.8 ± 12.3 years), 29 (2.96%) experienced SCD and 80 (8.17%) met the arrhythmic endpoint over median 5.82 years (interquartile range: 4.1 to 7.3 years). In the whole cohort, MFVA was strongly associated with SCD (hazard ratio: 10.1; 95% confidence interval [CI]: 1.42 to 1,278.9) and the arrhythmic endpoint (hazard ratio: 28.0; 95% CI: 4.07 to 3,525.4). In competing risks analyses, associations between LVEF <35% and SCD (subdistribution hazard ratio [sHR]: 2.99; 95% CI: 1.42 to 6.31) and the arrhythmic endpoint (sHR: 4.71; 95% CI: 2.97 to 7.47) were weaker. In competing risk analyses of the MFVA subcohort (n = 832), GZF using the 3SD method (GZF3SD) >5.0 g was strongly associated with SCD (sHR: 10.8; 95% CI: 3.74 to 30.9) and the arrhythmic endpoint (sHR: 7.40; 95% CI: 4.29 to 12.8). Associations between LVEF <35% and SCD (sHR: 2.62; 95% CI: 1.24 to 5.52) and the arrhythmic endpoint (sHR: 4.14; 95% CI: 2.61 to 6.57) were weaker. CONCLUSIONS: In CAD patients, MFVA plus quantified GZF3SD mass was more strongly associated with SCD and VAs than LVEF. In selecting patients for implantable cardioverter-defibrillators, assessment of MFVA followed by quantification of GZF3SD mass may be preferable to LVEF.


Coronary Artery Disease/epidemiology , Death, Sudden, Cardiac/epidemiology , Fibrosis , Myocardium/pathology , Aged , Contrast Media , Female , Follow-Up Studies , Heart/diagnostic imaging , Heart Transplantation/statistics & numerical data , Heart-Assist Devices/statistics & numerical data , Humans , Magnetic Resonance Imaging, Cine , Male , Retrospective Studies , Risk Assessment , Stroke Volume , Tachycardia, Ventricular/epidemiology , United Kingdom/epidemiology , Ventricular Fibrillation/epidemiology
15.
Eur Heart J Digit Health ; 2(4): 643-648, 2021 Dec.
Article En | MEDLINE | ID: mdl-36713105

Aims: Handheld electrocardiogram (ECG) monitors are increasingly used by both healthcare workers and patients to diagnose cardiac arrhythmias. There is a lack of studies validating the use of handheld devices against the standard 12-lead ECG. The Kardia 6L is a novel handheld ECG monitor which can produce a 6-lead ECG. In this study, we compare the 6L ECG against the 12-lead ECG. Methods and results: A prospective study consisting of unselected cardiac inpatients and outpatients at Leeds Teaching Hospital NHS Trust. All participants had a 12- and 6-lead ECGs. All ECG parameters were analysed by using a standard method template for consistency between independent observers. Electrocardiograms from the recorders were compared by the following statistical methods: linear regression, Bland-Altman, receiver operator curve, and kappa analysis. There were 1015 patients recruited. The mean differences between recorders were small for PR, QRS, cardiac axis, with receiver operator analysis area under the curve (AUC) of >80%. Mean differences for QT and QTc (between recorders) were also small, with AUCs for QT leads of >75% and AUCs for QTc leads of >60%. Key findings from Bland-Altman analysis demonstrate overall an acceptable agreement with few outliers instances (<6%, Bland-Altman analysis). Conclusion: Several parameters recorded by the Kardia 6L (QT interval in all six leads, rhythm detection, PR interval, QRS duration, and cardiac axis) perform closely to the gold standard 12-lead ECG. However, that consistency weakens for left ventricular hypertrophy, QRS amplitudes (Lead I and AVL), and ischaemic changes.

16.
Biomed Opt Express ; 11(11): 6271-6280, 2020 Nov 01.
Article En | MEDLINE | ID: mdl-33282489

Wound healing and other surgical technologies traditionally solved by suturing and stapling have recently been enhanced by the application of laser tissue welding. The usage of high energy laser radiation to anastomose tissues eliminates a foreign body reaction, reduces scar formation, and allows for the creation of watertight closure. In the current work, we show that an ultrafast pulsed fibre laser beam with 183 µJ·cm-2 energy fluence at 1550 nm provides successful welding of dissected chicken heart walls with the tensile strength of 1.03±0.12 kg·cm-2 equal to that of native tissue. The welding process was monitored employing fluorescence spectroscopy that detects the biochemical composition of tissues. We believe that fluorescence spectroscopy guided laser tissue welding is a promising approach for decreasing wound healing times and the avoiding risks of postoperative complications.

17.
Front Physiol ; 11: 1005, 2020.
Article En | MEDLINE | ID: mdl-32973549

Background: Short-term variability (STV) of repolarization of the monophasic action potential duration (MAPD) or activation recovery interval (ARI) on the intracardiac electrogram (EGM) increases abruptly prior to the occurrence of ventricular arrhythmias in the chronic AV-block (CAVB) dog model. Therefore, this parameter might be suitable for continuous monitoring of imminent arrhythmias using the EGM stored on an implanted device. However, 24/7 monitoring would require automatic STVARI measurement by the device. Objective: To evaluate a newly developed automatic measurement of STVARI for prediction of dofetilide-induced torsade de pointes (TdP) arrhythmias in the CAVB-dog. Methods: Two retrospective analyses were done on data from recently performed dog experiments. (1) In seven anesthetized CAVB-dogs, the new automatic STVARI method was compared with the gold standard STVMAPD at baseline and after dofetilide administration (0.025 mg/kg in 5 min). (2) The predictive value of the automatic method was compared to currently used STVARI methods, i.e., slope method and fiducial segment averaging (FSA) method, in 11 inducible (≥3 TdP arrhythmias) and 10 non-inducible CAVB-dogs. Results: (1) The automatic measurement of STVARI had good correlation with STVMAPD (r 2 = 0.89; p < 0.001). Bland-Altman analysis showed a small bias of 0.06 ms with limits of agreement between -0.63 and 0.76 ms. (2) STVARI of all three methods was significantly different between inducible and non-inducible dogs after dofetilide. The automatic method showed the highest predictive performance with an area under the ROC-curve of 0.93, compared to 0.85 and 0.87 of the slope and FSA methods, respectively. With a threshold of STV set at 1.69 ms, STVARI measured with the automatic method had a sensitivity of 0.91 and specificity of 0.90 in differentiating inducible from non-inducible subjects. Conclusion: We developed a fully-automatic method for measurement of STVARI on the intracardiac EGM that can accurately predict the occurrence of ventricular arrhythmias in the CAVB-dog. Future integration of this method into implantable devices could provide the opportunity for 24/7 monitoring of arrhythmic risk.

18.
Heart Rhythm ; 17(12): 2046-2055, 2020 12.
Article En | MEDLINE | ID: mdl-32717314

BACKGROUND: Vectorcardiographic QRS area (QRSarea) predicts clinical outcomes after cardiac resynchronization therapy (CRT). Myocardial scar adversely affects clinical outcomes after CRT. OBJECTIVE: The purpose of this study in patients with an ideally deployed quadripolar left ventricular (LV) lead (QUAD) was to determine whether reducing QRSarea leads to an acute hemodynamic response (AHR) and whether scar affects this interaction. METHODS: Patients (n = 26; age 69.2 ± 9.12 years [mean ± SD]) underwent assessment of the maximum rate of change of LV pressure (ΔLV dP/dtmax) during CRT using various left ventricular pacing locations (LVPLs). Cardiac magnetic resonance (CMR) scan was used to localize LV myocardial scar. RESULTS: Interindividually, ΔQRSarea (area under the receiver operating characteristic curve [AUC] 0.81; P <.001) and change in QRS duration (ΔQRSd) (AUC 0.76; P <.001) predicted ΔLV dP/dtmax after CRT. Scar burden correlated with ΔQRSarea (r = 0.35; P = .003), ΔQRSarea (r = 0.35; P = .003), and ΔQRSd (r = 0.46; P <.001). A reduction in QRSarea was observed with LVPLs remote from scar (-3.28 ± 38.1 µVs) or in LVPLs in patients with no scar at all (-43.8 ± 36.8 µVs), whereas LVPLs over scar increased QRSarea (22.2 ± 58.4 µVs) (P <.001 for all comparisons). LVPLs within 1 scarred LV segment were associated with lower ΔLV dP/dtmax (-2.21% ± 11.5%) than LVPLs remote from scar (5.23% ± 10.3%; P <.001) or LVPLs in patients with no scar at all (10.2% ± 7.75%) (both P <.001). CONCLUSION: Reducing QRSarea improves the AHR to CRT. Myocardial scar adversely affects ΔQRSarea and the AHR. These findings may support the use of ΔQRSarea and CMR in optimizing CRT using QUAD.


Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/methods , Cicatrix/therapy , Heart Ventricles/physiopathology , Hemodynamics/physiology , Magnetic Resonance Imaging, Cine/methods , Vectorcardiography , Aged , Bundle-Branch Block/etiology , Bundle-Branch Block/physiopathology , Cicatrix/complications , Cicatrix/diagnosis , Female , Heart Ventricles/diagnostic imaging , Humans , Male , ROC Curve , Treatment Outcome
19.
Europace ; 22(6): 956-963, 2020 06 01.
Article En | MEDLINE | ID: mdl-32285097

AIMS: Incidental left bundle branch block (iLBBB) is a frequent cause for cardiology referrals. In such instances, there is uncertainty as to its prognosis. We sought to determine the utility of cardiovascular magnetic resonance (CMR) in the risk stratification of patients with iLBBB. METHODS AND RESULTS: Clinical events were collected in patients with iLBBB who had CMR. Controls had no cardiac symptoms or cardiac disease, a normal CMR scan and electrocardiogram. Amongst patients with iLBBB [n = 193, aged 62.7 ± 12.6 years (mean ± SD)], 110/193 (56.9%) had an abnormal phenotype (iLBBBCMR+) and 83/110 (43.0%) had a normal phenotype (iLBBBCMR-). Over 3.75 years (median; inter-quartile range: 2.7-5.5), iLBBBCMR+ had a higher total mortality [adjusted hazard ratio (aHR) 6.49, 95% confidence interval (CI) 1.91-22.0] and total mortality or major adverse cardiac events (MACEs; aHR 9.15, 95% CI 2.56-32.6) than controls (n = 107). In contrast, iLBBBCMR- had a similar risk of total mortality compared with controls, but total mortality or MACEs was higher (aHR 4.24, 95% CI 1.17-15.4; P = 0.028). Amongst iLBBB patients, both myocardial fibrosis (aHR 5.15, 95% CI 1.53-17.4) and left ventricular ejection fraction (LVEF) ≤ 50% (aHR 3.88, 95% CI 1.67-9.06) predicted total mortality. Myocardial fibrosis plus LVEF ≤50% was associated with the highest risk of total mortality (aHR: 9.87, 95% CI 2.99-32.6) and total mortality or MACEs (aHR 3.98, 95% CI 1.73-9.11). CONCLUSIONS: Outcomes in iLBBBCMR+ were poor whereas survival in iLBBBCMR- was comparable with controls. Myocardial fibrosis and LVEF <50% had an additive effect on the risk of clinical outcomes. A CMR scan is pivotal in risk-stratifying patients with iLBBB.


Bundle-Branch Block , Ventricular Function, Left , Bundle-Branch Block/diagnosis , Electrocardiography , Humans , Prognosis , Stroke Volume
20.
Eur J Heart Fail ; 22(7): 1263-1272, 2020 07.
Article En | MEDLINE | ID: mdl-31975494

AIMS: Treatment options for patients with non-obstructive hypertrophic cardiomyopathy (HCM) are limited. We sought to determine whether biventricular (BiV) pacing improves exercise capacity in HCM patients, and whether this is via augmented diastolic filling. METHODS AND RESULTS: Thirty-one patients with symptomatic non-obstructive HCM were enrolled. Following device implantation, patients underwent detailed assessment of exercise diastolic filling using radionuclide ventriculography in BiV and sham pacing modes. Patients then entered an 8-month crossover study of BiV and sham pacing in random order, to assess the effect on exercise capacity [peak oxygen consumption (VO2 )]. Patients were grouped on pre-specified analysis according to whether left ventricular end-diastolic volume increased (+LVEDV) or was unchanged/decreased (-LVEDV) with exercise at baseline. Twenty-nine patients (20 male, mean age 55 years) completed the study. There were 14 +LVEDV patients and 15 -LVEDV patients. Baseline peak VO2 was lower in -LVEDV patients vs. +LVEDV patients (16.2 ± 0.9 vs. 19.9 ± 1.1 mL/kg/min, P = 0.04). BiV pacing significantly increased exercise ΔLVEDV (P = 0.004) and Δstroke volume (P = 0.008) in -LVEDV patients, but not in +LVEDV patients. Left ventricular ejection fraction and end-systolic elastance did not increase with BiV pacing in either group. This translated into significantly greater improvements in exercise capacity (peak VO2 + 1.4 mL/kg/min, P = 0.03) and quality of life scores (P = 0.02) in -LVEDV patients during the crossover study. There was no effect on left ventricular mechanical dyssynchrony in either group. CONCLUSION: Symptomatic patients with non-obstructive HCM may benefit from BiV pacing via augmentation of diastolic filling on exercise rather than contractile improvement. This may be due to relief of diastolic ventricular interaction. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov NCT00504647.


Cardiomyopathy, Hypertrophic , Heart Failure , Pacemaker, Artificial , Cardiac Pacing, Artificial , Cardiac Resynchronization Therapy Devices , Cardiomyopathy, Hypertrophic/therapy , Cross-Over Studies , Diastole , Exercise Tolerance , Female , Heart Failure/therapy , Humans , Male , Middle Aged , Quality of Life , Stroke Volume , Ventricular Function, Left
...