Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Heart Lung Transplant ; 41(6): 810-817, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35422347

RESUMEN

BACKGROUND: The majority (89%) of left ventricular assist device (LVAD) patients have an implantable cardioverter-defibrillator (ICD) in place. Due to the advances of modern-day LVAD therapy, more patients are on support for longer. This inevitably leads to more LVAD patients facing ICD generator battery depletion. Until now, there are insufficient data regarding periprocedural risks of generator replacements in a high-risk group like the LVAD cohort. METHODS: A retrospective, single-center analysis of pocket-related outcomes of all ICD generator replacements in LVAD and Non-LVAD patients between January 2014 and December 2018. The primary outcome was the combined endpoint of clinically significant pocket hematoma and/or cardiac implantable electronic device (CIED) infection in the first 6 months after ICD generator exchange. The clinically significant hematoma was defined as hematoma requiring reoperation, prolongation of hospitalization, or interruption of anticoagulation. The cumulative incidence function was calculated for the primary endpoint. RESULTS: Two hundred seventy-seven patients underwent ICD generator exchange in our clinic in this time. Of these, 251 patients had a complete 6-month follow-up regarding clinically significant pocket hematomas and pocket infections. One hundred ninety patients had no LVAD, and 61 patients were on LVAD support. The rate of the primary combined endpoint clinically significant pocket hematoma and/or CIED infection was 3.5 times higher in LVAD patients compared to the non-LVAD cohort (event rate 39.14 vs 11.07 per 100 patient-years, p = 0.048). Clinically significant pocket hematomas necessitating revision occurred nearly 4 times more often in the LVAD group (p = 0.042). Pocket device infection rates were around 16 times higher in LVAD patients compared to non-LVAD patients (p = 0.002). CONCLUSIONS: Compared to Non-LVAD patients, LVAD patients exhibit a relevant higher rate of clinically significant pocket hematoma and CIED infection after ICD generator exchange. This information should additionally be considered in the decision-making process regarding the indication for ICD generator exchange.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Desfibriladores Implantables/efectos adversos , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Hematoma/epidemiología , Hematoma/etiología , Humanos , Estudios Retrospectivos
2.
Metabolism ; 102: 153974, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31682799

RESUMEN

Mannose is a glucose-associated serum metabolite mainly released by the liver. Recent studies have shown several unexpected pleiotropic effects of mannose including increased regulatory T cells (Tregs), prevention of auto-immune disease and ability to reduce growth of human cancer cells. We have previously shown in large cohorts that elevated serum mannose levels are associated with future development of type 2 diabetes (T2D) and cardiovascular disease. However, potential direct effects of mannose on insulin sensitivity in vivo or in vitro are unknown. We here show that administration of mannose (0.1 g/kg BW twice daily) for one week in man did not elicit negative effects on meal-modified glucose tolerance, markers of inflammation or insulin levels. Tregs number and insulin signaling in human liver cells were unchanged. These data suggest that mannose is a marker, and not a mediator, of insulin resistance. To verify this, we examined serum mannose levels during long-term euglycemic hyperinsulinemic clamps in non-diabetic and T2D individuals. Mannose was reduced by insulin infusion in proportion to whole-body insulin sensitivity. Thus, mannose is a biomarker of insulin resistance which may be useful for the early identification of diabetic individuals with insulin resistance and increased risk of its complications.


Asunto(s)
Biomarcadores/sangre , Resistencia a la Insulina/fisiología , Insulina/metabolismo , Manosa/sangre , Anciano , Biomarcadores/metabolismo , Estudios de Casos y Controles , Femenino , Técnica de Clampeo de la Glucosa , Prueba de Tolerancia a la Glucosa , Humanos , Insulina/sangre , Masculino , Manosa/metabolismo , Persona de Mediana Edad , Transducción de Señal/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA