Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 24
1.
Sci Rep ; 14(1): 7758, 2024 04 02.
Article En | MEDLINE | ID: mdl-38565890

Knowledge about anatomical details seems to facilitate the procedure and planning of prostatic artery embolization (PAE) in patients with symptomatic benign prostatic hyperplasia (BPS). The aim of our study was the pre-interventional visualization of the prostatic artery (PA) with MRA and the correlation of iliac elongation and bifurcation angles with technical success of PAE and technical parameters. MRA data of patients with PAE were analysed retrospectively regarding PA visibility, PA type, vessel elongation, and defined angles were correlated with intervention time, fluoroscopy time, dose area product (DAP), cumulative air kerma (CAK), contrast media (CM) dose and technical success of embolization. T-test, ANOVA, Pearson correlation, and Kruskal-Wallis test was applied for statistical analysis. Between April 2018 and March 2021, a total of 78 patients were included. MRA identified the PA origin in 126 of 147 cases (accuracy 86%). Vessel elongation affected time for catheterization of right PA (p = 0.02), fluoroscopy time (p = 0.05), and CM dose (p = 0.02) significantly. Moderate correlation was observed for iliac bifurcation angles with DAP (r = 0.30 left; r = 0.34 right; p = 0.01) and CAK (r = 0.32 left; r = 0.36 right; p = 0.01) on both sides. Comparing the first half and second half of patients, median intervention time (125 vs. 105 min.) and number of iliac CBCT could be reduced (p < 0.001). We conclude that MRA could depict exact pelvic artery configuration, identify PA origin, and might obviate iliac CBCT. Vessel elongation of pelvic arteries increased intervention time and contrast media dose while the PA origin had no significant influence on intervention time and/or technical success.


Embolization, Therapeutic , Prostatic Hyperplasia , Male , Humans , Prostate/diagnostic imaging , Prostate/blood supply , Prostatic Hyperplasia/diagnostic imaging , Prostatic Hyperplasia/therapy , Contrast Media , Embolization, Therapeutic/methods , Magnetic Resonance Angiography , Retrospective Studies , Arteries/diagnostic imaging , Treatment Outcome
2.
Bioengineering (Basel) ; 11(3)2024 Feb 22.
Article En | MEDLINE | ID: mdl-38534481

CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contrast protocols were evaluated. For this purpose, CT protocol parameters, IQ ratings, radiation exposure (CTDIvol), and central patient diameters were sampled. Eventually, the data from 14 sites and 534 CT acquisitions were analyzed. IQ was rated good for 81% of the evaluated examinations. Motion, beam-hardening artefacts, or image noise were reasons for a suboptimal IQ. The tube potential ranged between 80 and 140 kVp, with the majority between 100 and 120 kVp. CTDIvol was 3.7 ± 3.4 mGy. Most healthcare facilities included did not have a specific non-contrast CT protocol. Furthermore, CT protocols for chest imaging varied in their settings and radiation exposure. In future, it will be necessary to make recommendations regarding the required IQ and protocol parameters for the majority of CT scanners to enable comparable IQ as well as radiation exposure for different sites but identical diagnostic questions.

3.
Diagnostics (Basel) ; 14(3)2024 Jan 27.
Article En | MEDLINE | ID: mdl-38337796

PURPOSE: To assess the diagnostic accuracy of BMI-adapted, low-radiation and low-iodine dose, dual-source aortic CT for endoleak detection in non-obese and obese patients following endovascular aortic repair. METHODS: In this prospective single-center study, patients referred for follow-up CT after endovascular repair with a history of at least one standard triphasic (native, arterial and delayed phase) routine CT protocol were enrolled. Patients were divided into two groups and allocated to a BMI-adapted (group A, BMI < 30 kg/m2; group B, BMI ≥ 30 kg/m2) double low-dose CT (DLCT) protocol comprising single-energy arterial and dual-energy delayed phase series with virtual non-contrast (VNC) reconstructions. An in-patient comparison of the DLCT and routine CT protocol as reference standard was performed regarding differences in diagnostic accuracy, radiation dose, and image quality. RESULTS: Seventy-five patients were included in the study (mean age 73 ± 8 years, 63 (84%) male). Endoleaks were diagnosed in 20 (26.7%) patients, 11 of 53 (20.8%) in group A and 9 of 22 (40.9%) in group B. Two radiologists achieved an overall diagnostic accuracy of 98.7% and 97.3% for endoleak detection, with 100% in group A and 95.5% and 90.9% in group B. All examinations were diagnostic. The DLCT protocol reduced the effective dose from 10.0 ± 3.6 mSv to 6.1 ± 1.5 mSv (p < 0.001) and the total iodine dose from 31.5 g to 14.5 g in group A and to 17.4 g in group B. CONCLUSION: Optimized double low-dose dual-source aortic CT with VNC, arterial and delayed phase images demonstrated high diagnostic accuracy for endoleak detection and significant radiation and iodine dose reductions in both obese and non-obese patients compared to the reference standard of triple phase, standard radiation and iodine dose aortic CT.

4.
Curr Med Imaging ; 2024 Feb 26.
Article En | MEDLINE | ID: mdl-38415484

Background: Despite the availability of vaccines, there is an increasing number of SARS-CoV-2-breakthrough-infections. OBJECTIVE: The aim of this study was to determine whether there is a radiological difference in lung parenchymal involvement between infected vaccinated and unvaccinated patients. Additionally, we aimed to investigate whether vaccination has an impact on the course of illness and the need for intensive care. METHODS: This study includes all patients undergoing chest computed tomography (CT) or x-ray imaging in case of a proven SARS-CoV-2 infection between September and November 2021. Anonymized CT and x-ray images were reviewed retrospectively and in consensus by two radiologists, applying an internal severity score scheme for CT and x-ray as well as CARE and BRIXIA scores for x-ray. Radiological findings were compared to vaccination status, comorbidities, inpatient course of the patient's illness and the subjective onset of symptoms. RESULTS: In total, 38 patients with acute SARS-CoV-2 infection underwent a CT scan, and 168 patients underwent an x-ray examination during the study period. Of these, 32% were vaccinated in the CT group, and 45% in the x-ray group. For the latter, vaccinated patients exhibited significantly more comorbidities (cardiovascular (p=0.002), haemato-oncological diseases (p=0.016), immunosuppression (p=0.004)), and a higher age (p<0.001). Vaccinated groups showed significantly lower extent of lung involvement (severity scores in CT cohort and x-ray cohort both p≤0.020; ARDS 42% in unvaccinated CT cohort vs. 8% in vaccinated CT cohort). Furthermore, vaccinated patients in the CT cohort had significantly less need for intensive care treatment (p=0.040). CONCLUSION: Our data suggest that vaccination, in the case of breakthrough infection, favours a milder course of illness concerning lung parenchymal involvement and the need for intensive care, despite negative predictors, such as immunosuppression or other pre-existing conditions.

.

5.
Article En | MEDLINE | ID: mdl-38265442

PURPOSE: The growing incidence of implant-associated infections (IAIs) caused by biofilm-forming Staphylococcus aureus in combination with an increasing resistance to antibiotics requires new therapeutic strategies. Lysostaphin has been shown to eliminate this biofilm. Own studies confirm the effectiveness in a murine model. The current study characterizes the effects of lysostaphin-coated plates in an IAI minipig model. METHODS: The femur of 30 minipigs was stabilized with a five-hole plate, a bone defect was created, and in 20 cases methicillin-resistant Staphylococcus aureus was applied. Ten animals served as control group. After 14 days, local debridement, lavage, and plate exchange (seven-hole plate) were performed. Ten of the infected minipigs received an uncoated plate and 10 a lysostaphin-coated plate. On day 84, the minipigs were again lavaged, followed by euthanasia. Bacterial load was quantified by colony-forming units (CFU). Immunological response was determined by neutrophils, as well as interleukins. Fracture healing was assessed radiologically. RESULTS: CFU showed significant difference between infected minipigs with an uncoated plate and minipigs with a lysostaphin-coated plate (p = 0.0411). The infection-related excessive callus formation and calcification was significantly greater in the infected animals with an uncoated plate than in animals with a lysostaphin-coated plate (p = 0.0164/p = 0.0033). The analysis of polymorphonuclear neutrophils and interleukins did not reveal any pioneering findings. CONCLUSION: This study confirms the minipig model for examining IAI. Furthermore, coating of plates using lysostaphin could be a promising tool in the therapeutic strategies of IAI. Future studies should focus on coating technology of implants and on translation into a clinical model.

6.
CVIR Endovasc ; 6(1): 50, 2023 Oct 23.
Article En | MEDLINE | ID: mdl-37870638

BACKGROUND: True uterine artery aneurysms, especially during pregnancy, are a rare entity and not well understood. Clinical symptoms are unspecific pelvic pain and pressure. Diagnosis can be confirmed by transvaginal color-coded-sonography and/or magnetic resonance imaging. Because of potential risk of rupture, immediate interdisciplinary discussion and treatment planning in the best interests of both mother and child is crucial. CASE PRESENTATION: We present a 31-year-old pregnant woman with increasing pelvic pain and pressure. Diagnosis of an unruptured uterine artery aneurysm was confirmed by color-coded-sonography and magnetic resonance angiography. After interdisciplinary consultation, successful endovascular super-selective coil-embolization was performed by using X-ray fluoroscopy. Thus, fetal radiation dose during treatment with 4.33 mGy (VirtualDoseTM) was as low as possible with no immediate harm to the fetus. CONCLUSIONS: Unruptured true uterine artery aneurysms can be successfully treated by endovascular super-selective coil-embolization during early pregnancy with no immediate harm to the fetus.

7.
J Radiol Prot ; 43(3)2023 09 11.
Article En | MEDLINE | ID: mdl-37619552

Although iso-centric patient positioning is enormously important in computed tomography (CT), it is complicated in thoracoabdominal imaging by the varying dimensions of the body. Patient positioning can affect the appearance of the patient on the localiser. Positioned too close to the x-ray tube, a patient appears considerably more voluminous. The goal of this study is to assess the difference in radiation exposure of combined chest and abdomen CT scans between scans with prior 0°- and 180°-localisers in conjunction with patient positioning. In this IRB-approved retrospective study, patients who had two routine thoracoabdominal CT scans on the same CT scanner, one with a prior 0°- and one with a prior 180°-localiser, were included. To evaluate the radiation exposure of the thoracoabdominal CT examination regarding the tube position during the localiser, volumetric computed tomography dose index (CTDIvol), size-specific dose estimate (SSDE), patient diameter and positioning within the iso-centre for three positions (heart, abdomen, femur level) were compared with regard to the tube position during the prior localiser. CT examinations of 114 patients were included. Despite similar patient weight and diameter between the two examinations, SSDE and CTDIvolwas significantly larger (up to 73%) with 180°-localisers. Patient offset from the iso-centre ranged between -9 mm at the centre slice (abdomen level) to -43 mm at the most caudal slice at the pelvis (femur level), causing a significant magnification (p < 0.001) on 180°-localisers with a subsequent increase of the apparent attenuation. The results of this study emphasise the use of 0°-localisers in thoracoabdominal CTs, since 180°-localisers caused patient magnification with subsequent increase in radiation exposure. The advantage of 180°-localisers, namely reducing the dose in thyroid and breast, is eliminated if the dose of the CT scan increases significantly in the abdomen and pelvis.


Radiation Exposure , Tomography, X-Ray Computed , Humans , Retrospective Studies , Tomography Scanners, X-Ray Computed , Patient Positioning
8.
Clin Imaging ; 99: 25-30, 2023 Jul.
Article En | MEDLINE | ID: mdl-37043870

BACKGROUND: To analyze contrast free adrenal vein sampling (AVS) for differentiating unilateral from bilateral disease in patients diagnosed with hypertension due to primary aldosteronism (PA). METHODS: Consecutive patients with PA and subsequent contrast medium free AVS between April 2015 and March 2020 were retrospectively included. Cross-sectional imaging (CSI), AVS and clinical data were analyzed regarding diagnostic performance. In addition, patients with lateralisation receiving adrenalectomy were compared to a control group treated with mineralocorticoid antagonists. RESULTS: In total 186 patients with AVS were included. The success rate for bilateral catheterization was 88% (median effective dose 2.8 mSv). CSI had an accuracy of 60% (CI: 0.52-0.67) in the detection of lateralization compared to AVS. Patients with bilateral adrenal hyperplasia and those with aldosterone-producing adenoma did not differ in systolic blood pressure (sBP) (p = 0.63) or number of antihypertensive drugs (NAD) (p = 0.11). After adrenalectomy, 28 patients were cured (51%; sBP ≤130 mmHg, NAD = 0), 18 were improved (33%; decrease of sBP ≥20 mmHg and NAD), and 8 were unchanged (15%). Serum renin increased significantly after treatment (p < 0.01). CONCLUSION: Contrast medium free AVS is a reliable procedure in the diagnostic management of patients with PA with high technical success rate. The accordance between CSI and results from AVS was only moderate indicating the central role of AVS in the diagnostic work-up of patients with PA. Patients with predominant disease diagnosed with AVS had a high cure rate and/or significant improvement after adrenalectomy.


Adrenal Glands , Hyperaldosteronism , Humans , Adrenal Glands/diagnostic imaging , Hyperaldosteronism/diagnosis , Hyperaldosteronism/drug therapy , Retrospective Studies , NAD , Adrenalectomy
9.
Diagnostics (Basel) ; 12(7)2022 Jul 05.
Article En | MEDLINE | ID: mdl-35885532

Deep-learning (DL) noise reduction techniques in computed tomography (CT) are expected to reduce the image noise while maintaining the clinically relevant information in reduced dose acquisitions. This study aimed to assess the size, attenuation, and objective image quality of reno-ureteric stones denoised using DL-software in comparison to traditionally reconstructed low-dose abdominal CT-images and evaluated its clinical impact. In this institutional review-board-approved retrospective study, 45 patients with renal and/or ureteral stones were included. All patients had undergone abdominal CT between August 2019 and October 2019. CT-images were reconstructed using the following three methods: filtered back-projection, iterative reconstruction, and PixelShine (DL-software) with both sharp and soft kernels. Stone size, CT attenuation, and objective image quality (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)) were evaluated and compared using Bonferroni-corrected Friedman tests. Objective image quality was measured in six regions-of-interest. Stone size ranged between 4.4 × 3.1−4.4 × 3.2 mm (sharp kernel) and 5.1 × 3.8−5.6 × 4.2 mm (soft kernel). Mean attenuation ranged between 704−717 Hounsfield Units (HU) (soft kernel) and 915−1047 HU (sharp kernel). Differences in measured stone sizes were ≤1.3 mm. DL-processed images resulted in significantly higher CNR and SNR values (p < 0.001) by decreasing image noise significantly (p < 0.001). DL-software significantly improved objective image quality while maintaining both correct stone size and CT-attenuation values. Therefore, the clinical impact of stone assessment in denoised image data sets remains unchanged. Through the relevant noise suppression, the software additionally offers the potential to further reduce radiation exposure.

10.
Rofo ; 194(10): 1110-1118, 2022 10.
Article En | MEDLINE | ID: mdl-35545100

PURPOSE: To assess whether it is possible to reliably detect patients with strong suspicion of COVID-19 despite initially negative quantitative polymerase-chain-reaction (qPCR) tests by means of computed tomography (CT). MATERIALS AND METHODS: 437 patients with suspected COVID-19 but initially negative qPCR and subsequent chest CT between March 13 and November 30, 2020 were included in this retrospective study. CT findings were compared to results of successive qPCR tests (minimum of 3 qPCR tests if CT suggested infection) to determine the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT for diagnosing COVID-19. RESULTS: COVID-19 was diagnosed correctly with a sensitivity of 100 % [95 % confidence interval (CI): 65-100] and a specificity of 88 % [95 % CI: 84-90]. A PPV of 12 % [95 % CI: 6-22] and an NPV of 100 % [95 % CI: 99-100] were determined. CONCLUSION: CT is able to detect COVID-19 before qPCR in initially negative patients in this special study setting. Similar CT findings in COVID-19 and other atypical pneumonias can lead to high numbers of false-positive patients, reducing the specificity of CT. KEY POINTS: · Low-dose chest CT is able to diagnose COVID-19 in symptomatic patients even in cases of an initially negative quantitative PCR result and therefore is a fast support method to detect COVID-19, especially in early disease.. · Low-dose chest CT can reliably exclude COVID-19 in a pandemic setting.. · CT does not always ensure a reliable differentiation from other viral diseases.. CITATION FORMAT: · Valentin B, Steuwe A, Wienemann T, et al. CT Findings in Patients with COVID-19-Compatible Symptoms but Initially Negative qPCR Test. Fortschr Röntgenstr 2022; 194: 1110 - 1118.


COVID-19 , COVID-19/diagnostic imaging , Humans , Retrospective Studies , SARS-CoV-2 , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
11.
Diagnostics (Basel) ; 12(3)2022 Mar 10.
Article En | MEDLINE | ID: mdl-35328228

The purpose of this study was to prospectively analyse image quality and radiation dose of body mass index (BMI)-adapted low-radiation and low-iodine dose CTA of the thoracoabdominal aorta in obese and non-obese patients. This prospective, single-centre study included patients scheduled for aortic CTA between November 2017 and August 2020 without symptoms of high-grade heart failure. A BMI-adapted protocol was used: Group A/Group B, BMI < 30/≥ 30 kg/m2, tube potential 80/100 kVp, total iodine dose 14.5/17.4 g. Intraindividual comparison with the institutional clinical routine aortic CTA protocol was performed. The final study cohort comprised 161 patients (mean 71.1 ± 9.4 years, 32 women), thereof 126 patients in Group A (mean BMI 25.4 ± 2.8 kg/m2) and 35 patients in Group B (34.0 ± 3.4 kg/m2). Mean attenuation over five aortoiliac measurement positions for Group A/B was 354.9 ± 78.2/262.1 ± 73.0 HU. Mean effective dose for Group A/B was 3.05 ± 0.46/6.02 ± 1.14 mSv. Intraindividual comparison in 50 patients demonstrated effective dose savings for Group A/B of 34.4 ± 14.5/25.4 ± 14.1% (both p < 0.001), and iodine dose savings for Group A/B of 54/44.8%. Regression analysis showed that female sex and increasing age were independently associated with higher vascular attenuation. In conclusion, BMI-adapted, low-radiation and low-iodine dose CTA of the thoracoabdominal aorta delivers diagnostic image quality in non-obese and obese patients without symptoms of high-grade heart failure, with superior image quality in females and the elderly.

12.
Rofo ; 194(8): 862-872, 2022 08.
Article En | MEDLINE | ID: mdl-35211925

PURPOSE: Classifications were created to facilitate radiological evaluation of the novel coronavirus disease 2019 (COVID-19) on computed tomography (CT) images. The categorical CT assessment scheme (CO-RADS) categorizes lung parenchymal changes according to their likelihood of being caused by SARS-CoV-2 infection. This study investigates the diagnostic accuracy of diagnosing COVID-19 with CO-RADS compared to the Thoracic Imaging Section of the German Radiological Society (DRG) classification and Radiological Society of North America (RSNA) classification in an anonymized patient cohort. To mimic advanced disease stages, follow-up examinations were included as well. METHOD: This study includes all patients undergoing chest CT in the case of a suspected SARS-CoV-2 infection or an already confirmed infection between March 13 and November 30, 2020. During the study period, two regional lockdowns occurred due to high incidence values, increasing the pre-test probability of COVID-19. Anonymized CT images were reviewed retrospectively and in consensus by two radiologists applying CO-RADS, DRG, and RSNA classification. Afterwards, CT findings were compared to results of sequential real-time reverse transcriptase polymerase chain reaction (qPCR) test performed during hospitalization to determine statistical analysis for diagnosing COVID-19. RESULTS: 536 CT examinations were included. CO-RADS, DRG and RSNA achieved an NPV of 96 %/94 %/95 % (CO-RADS/DRG/RSNA), PPV of 83 %/80 %/88 %, sensitivity of 86 %/76 %/80 %, and specificity of 96 %/95 %/97 %. The disease prevalence was 20 %. CONCLUSION: All applied classifications can reliably exclude a SARS-CoV-2 infection even in an anonymous setting. Nevertheless, pre-test probability was high in our study setting and has a great influence on the classifications. Therefore, the applicability of the individual classifications will become apparent in the future with lower prevalence and incidence of COVID-19. KEY POINTS: · CO-RADS, DRG, and RSNA classifications help to reliably detect infected patients in an anonymized setting. · Pre-test probability has a great influence on the individual classifications. · Difficulties in an anonymized study setting are severe pulmonary changes and residuals.. CITATION FORMAT: · Valentin B, Steuwe A, Wienemann T et al. Applicability of CO-RADS in an Anonymized Cohort Including Early and Advanced Stages of COVID-19 in Comparison to the Recommendations of the German Radiological Society and Radiological Society of North America. Fortschr Röntgenstr 2022; 194: 862 - 872.


COVID-19 , COVID-19/diagnostic imaging , Communicable Disease Control , Humans , North America/epidemiology , Retrospective Studies , SARS-CoV-2
13.
J Radiol Prot ; 42(2)2022 Mar 09.
Article En | MEDLINE | ID: mdl-35130526

To implement typical doses (TD) and typical values (TV) for fluoroscopic diagnostic and interventional procedures. A total of 3811 fluoroscopic procedures performed within 34 months on three devices were included in this retrospective study. Dose-, patient- and procedure-related information were extracted using the institutional dose management system (DMS). TD/TV were defined as median dose and calculated for the five most frequent procedures per device for dose area product (DAP), cumulative air kerma (CAK) and fluoroscopy time (FT). National diagnostic reference levels and other single facility studies were compared to our results. Additionally, the five procedures with the highest doses of each device were analysed. To evaluate the data coverage of the DMS compared to the picture archiving and communication system (PACS), procedure lists were extracted from the PACS and compared to the procedure information extracted from the DMS. TD/TV for 15 procedures were implemented. Among all devices, TD for DAP ranged between 0.6 Gycm2for port catheter control (n= 64) and 145.9 Gycm2for transarterial chemoembolisation (n= 84). TD for CAK ranged between 5 mGy for port catheter control and 1397 mGy for aneurysm treatment (n= 129) and TV for FT ranged between 0.3 min for upper cavography (n= 67) and 51.4 min for aneurysm treatment. TD for DAP and CAK were lower or within the range of other single facility studies. The five procedures with the highest median DAP per device were identified, 6 of 15 procedures were also found to be among the most frequent procedures. Data coverage of the DMS compared to the PACS ranged between 71% (device 2, stroke treatment) and 78% (device 1, lower limb angiography) for the most common procedure per device. Thus, in 22%-29% of cases dose data of the performed procedure was not transferred into the DMS. We implemented TD/TV for fluoroscopic diagnostic and interventional procedures which enable a comprehensive dose analysis and comparison with previously published values.


Radiography, Interventional , Fluoroscopy , Humans , Radiation Dosage , Retrospective Studies
14.
J Clin Med ; 10(19)2021 Oct 01.
Article En | MEDLINE | ID: mdl-34640591

Contrast-induced nephropathy (CIN) resembles an important complication of radiographic contrast medium (XCM) displayed by a rise in creatinine levels 48-72 h after XCM administration. The purpose of the current study was to evaluate microstructural renal changes due to CIN in high-risk patients by diffusion weighted (DWI) and diffusion tensor imaging (DTI). Fifteen patients (five CIN and ten non-CIN) scheduled for cardiological intervention were included in the study. All patients were investigated pre- and post-intervention on a clinical 3T scanner. After anatomical imaging, renal DWI was performed by a paracoronal echo-planar-imaging sequence. Renal clinical routine serum parameters and advanced urinary injury markers were determined to monitor renal function. We observed a drop in cortical and medullar apparent diffusion coefficient (ADC) and fractional anisotropy (FA) before and after XCM administration in the CIN group. In contrast, the non-CIN group differed only in medullary ADC. The decrease of ADC and FA was apparent even before serum parameters of the kidney changed. In conclusion, DWI/DTI may be a useful tool for monitoring high-risk CIN patients as part of multi-modality based clinical protocol. Further studies, including advanced analysis of the diffusion signal, may improve the identification of patients at risk for CIN.

15.
Br J Radiol ; 94(1127): 20210084, 2021 Nov 01.
Article En | MEDLINE | ID: mdl-33989046

OBJECTIVE: To assess accuracy of dual-energy computed tomography (DECT) to differentiate uric acid from calcium urinary stones in dual-energy split filter vs sequential-spiral vs dual-source acquisition. METHODS: Thirty-four urinary stones (volume 89.0 ± 77.4 mm³; 17 calcium stones, 17 uric acid stones) were scanned in a water-filled phantom using a split-filter equipped CT scanner (SOMATOM Definition Edge, Siemens Healthineers, Forchheim, Germany) in split-filter mode at 120 kVp and sequential-spiral mode at 80 and 140 kVp. Additional DE scans were acquired at 80 and 140 kVp (tin filter) with a dual-source CT scanner (SOMATOM Definition FLASH, Siemens Healthineers). Scans were performed with a CTDIvol of 7.3 mGy in all protocols. Urinary stone categorization was based on dual energy ratio (DER) using an automated 3D segmentation. As reference standard, infrared spectroscopy was used to determine urinary stone composition. RESULTS: All three DECT techniques significantly differentiated between uric acid and calcium stones by attenuation values and DERs (p < 0.001 for all). Split-filter DECT provided higher DERs for uric acid stones, when compared with dual-source and sequential-spiral DECT, and lower DERs for calcified stones when compared with dual-source DECT (p < 0.001 for both), leading to a decreased accuracy for material differentiation. CONCLUSION: Split-filter DECT, sequential-spiral DECT and dual-source DECT all allow for the acquisition of DER to classify urinary stones. ADVANCES IN KNOWLEDGE: Split-filter DECT enables the differentiation between uric acid and calcium stones despite decreased spectral separation when compared with dual-source and dual-spiral DECT.


Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Urinary Calculi/diagnostic imaging , Humans , Phantoms, Imaging , Reproducibility of Results
16.
Int J Legal Med ; 135(5): 1869-1878, 2021 Sep.
Article En | MEDLINE | ID: mdl-33629138

INTRODUCTION: Postmortem multi-detector computed tomography (PMCT) has become an important part in forensic imaging. Modern reconstruction techniques such as iterative reconstruction (IR) are frequently used in postmortem CT angiography (PMCTA). The image quality of PMCTA depends on the strength of IR. For this purpose, we aimed to investigate the impact of different advanced IR levels on the objective and subjective PMCTA image quality. MATERIAL AND METHODS: We retrospectively analyzed the coronary arteries of 27 human cadavers undergoing whole-body postmortem CT angiography between July 2017 and March 2018 in a single center. Iterative reconstructions of the coronary arteries were processed in five different level settings (0%; 30%; 50%; 70%; 100%) by using an adaptive statistical IR method. We evaluated the objective (contrast-to-noise ratio (CNR)) and subjective image quality in several anatomical locations. RESULTS: Our results demonstrate that the increasing levels of an IR technique have relevant impact on the image quality in PMCTA scans in forensic postmortem examinations. Higher levels of IR have led to a significant reduction of image noise and therefore to a significant improvement of objective image quality (+ 70%). However, subjective image quality is inferior at higher levels of IR due to plasticized image appearance. CONCLUSION: Objective image quality in PMCTA progressively improves with increasing level of IR with the best CNR at the highest IR level. However, subjective image quality is best at low to medium levels of IR. To obtain a "classic" image appearance with optimal image quality, PMCTAs should be reconstructed at medium levels of IR.


Computed Tomography Angiography , Coronary Vessels/diagnostic imaging , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Autopsy , Cadaver , Contrast Media , Female , Humans , Male , Middle Aged , Retrospective Studies , Signal-To-Noise Ratio
17.
Rofo ; 193(6): 658-666, 2021 Jun.
Article En, De | MEDLINE | ID: mdl-33327032

BACKGROUND: Primary aldosteronism (PA) is the most common detectable cause of secondary hypertension. The majority of patients have either an adrenal aldosterone-producing adenoma (APA) or bilateral adrenal hyperplasia (BAH) demanding different therapeutic approaches. Screening tests and imaging cannot reliably distinguish between a unilateral or bilateral PA. METHODS: This review article gives an overview concerning etiology, diagnostics, and therapeutic options of PA, and reviews the indication, the technique, and relevance of selective adrenal venous sampling (AVS) in the context of the current literature and the authors' experience. RESULTS: AVS can verify or exclude a unilaterally dominated secretion with a high success rate. Patients with PA and a unilateral APA can be treated curatively by adrenalectomy. CONCLUSIONS: AVS is an established diagnostic examination for differentiation of unilateral from bilateral adrenal disease in patients with PA. KEY POINTS: · Selective adrenal venous sampling (AVS) is a safe, reliable, and minimally invasive method to detect a unilateral or bilateral adrenal adrenal gland disease.. · Verification of lateralization by AVS has direct therapeutic relevance for patients with primary aldosteronism (PA).. · AVS can be performed with low radiation exposure, without contrast medium, and with a high success rate when performed by an experienced interventional radiologist.. CITATION FORMAT: · Loberg C, Antoch G, Stegbauer J et al. Update: Selective adrenal venous sampling (AVS) - Indication, technique, and significance. Fortschr Röntgenstr 2021; 193: 658 - 666.


Adrenal Glands , Aldosterone , Hyperaldosteronism , Veins , Adrenal Glands/diagnostic imaging , Adrenal Glands/surgery , Adrenalectomy , Aldosterone/blood , Humans , Hyperaldosteronism/blood , Hyperaldosteronism/diagnostic imaging , Hyperaldosteronism/surgery , Retrospective Studies , Veins/diagnostic imaging
18.
Br J Radiol ; 94(1117): 20200677, 2021 Jan 01.
Article En | MEDLINE | ID: mdl-33095654

OBJECTIVES: Modern reconstruction and post-processing software aims at reducing image noise in CT images, potentially allowing for a reduction of the employed radiation exposure. This study aimed at assessing the influence of a novel deep-learning based software on the subjective and objective image quality compared to two traditional methods [filtered back-projection (FBP), iterative reconstruction (IR)]. METHODS: In this institutional review board-approved retrospective study, abdominal low-dose CT images of 27 patients (mean age 38 ± 12 years, volumetric CT dose index 2.9 ± 1.8 mGy) were reconstructed with IR, FBP and, furthermore, post-processed using a novel software. For the three reconstructions, qualitative and quantitative image quality was evaluated by means of CT numbers, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in six different ROIs. Additionally, the reconstructions were compared using SNR, peak SNR, root mean square error and mean absolute error to assess structural differences. RESULTS: On average, CT numbers varied within 1 Hounsfield unit (HU) for the three assessed methods in the assessed ROIs. In soft tissue, image noise was up to 42% lower compared to FBP and up to 27% lower to IR when applying the novel software. Consequently, SNR and CNR were highest with the novel software. For both IR and the novel software, subjective image quality was equal but higher than the image quality of FBP-images. CONCLUSION: The assessed software reduces image noise while maintaining image information, even in comparison to IR, allowing for a potential dose reduction of approximately 20% in abdominal CT imaging. ADVANCES IN KNOWLEDGE: The assessed software reduces image noise by up to 27% compared to IR and 48% compared to FBP while maintaining the image information.The reduced image noise allows for a potential dose reduction of approximately 20% in abdominal imaging.


Image Interpretation, Computer-Assisted/methods , Radiation Dosage , Radiography, Abdominal/methods , Tomography, X-Ray Computed/methods , Abdomen/diagnostic imaging , Adult , Deep Learning , Female , Humans , Male , Middle Aged , Retrospective Studies , Signal-To-Noise Ratio , Young Adult
19.
J Child Orthop ; 14(6): 554-561, 2020 Dec 01.
Article En | MEDLINE | ID: mdl-33343751

PURPOSE: Reports on heterogenous groups of patients have indicated that pedicle screw insertion guided by navigation (PIN) leads to, for the patient, higher doses of radiation compared with pedicle screw insertion guided by fluoroscopy (PIF). This would be a major concern, especially in paediatric deformity correction. METHODS: After a power analysis (aiming at > 0.8) 293 pedicle screws which were inserted in patients with adolescent idiopathic scoliosis were analyzed by comparing effective dose and fluoroscopy time per screw for three different techniques. Groups 2 and 3 were matched to Group 1 by Lenke type of scoliosis. Group 1 were prospectively enrolled consecutive patients that have been operated on by PIN with image acquisition by preoperative CT scan (CTS). Group 2 were consecutive retrospectively matched patients who have been operated on by PIN with image acquisition by an intraoperative 3D scan (3DS). Group 3 were consecutive retrospectively matched patients who have been operated on by PIF. RESULTS: Mean dose of radiation per screw was 1.0 mSv (sd 0.8) per screw in CTS patients, 0.025 mSv (sd 0.001) per screw in 3DS patients and 0.781 mSv (sd 0.12) per screw in PIF patients. The difference was significant (p < 0.0001). CONCLUSION: When we compared different techniques of navigation, navigation by image acquisition with CTS showed a significantly higher (by 97.5%) dose of radiation per screw for the patient than navigation by image acquisition by a 3DS. Navigation by 3DS showed significantly lower effective dose per screw for the adolescent patients than the fluoroscopic technique. LEVEL OF EVIDENCE: II.

20.
J Radiol Prot ; 40(3): 877-891, 2020 09.
Article En | MEDLINE | ID: mdl-32604085

OBJECTIVES: The detection of Coronavirus Disease 2019 (COVID-19) by reverse transcription polymerase chain reaction (RT-PCR) has varying sensitivity. Computed tomography (CT) of the chest can verify infection in patients with clinical symptoms and a negative test result, accelerating treatment and actions to prevent further contagion. However, CT employs ionising radiation. The purpose of this study was to evaluate protocol settings, associated radiation exposure, image quality and diagnostic performance of a low-dose CT protocol in a university hospital setting. MATERIALS AND METHODS: Chest CT examinations were performed on a single scanner (Somatom Definition Edge, Siemens Healthineers, Germany) in 105 symptomatic patients (60 male, 45 female). Images were evaluated with regard to protocol parameters, image quality, radiation exposure and diagnostic accuracy. Serial RT-PCR served as the standard of reference. Based on this reference standard sensitivity, specificity, positive and negative predictive values of CT with 95% confidence interval were calculated. RESULTS: The mean effective dose was 1.3 ± 0.4 mSv (0.7-2.9 mSv) for the patient cohort (mean age 66.6 ± 16.7 years (19-94 years), mean body mass index (BMI) 26.6 ± 5.3 kg m-2 (16-46 kg/m2)). A sensitivity of 100 [95% CI: 82-100]%, a specificity of 78 [95% CI: 68-86]%, a positive predictive value of 50 [95% CI: 33-67]% and a negative predictive value of 100 [95% CI: 95-100]% were obtained. No COVID-19 diagnoses were missed by CT. Image noise did not strongly correlate with BMI or patient diameter and was rated as average. CONCLUSIONS: We presented a robust imaging procedure with a chest CT protocol for confident diagnosis of COVID-19. Even for an overweight patient cohort, an associated radiation exposure of only 1.3 ± 0.4 mSv was achieved with sufficient diagnostic quality to exclude COVID-19.


Coronavirus Infections/diagnostic imaging , Pneumonia, Viral/diagnostic imaging , Radiation Dosage , Radiography, Thoracic/standards , Tomography, X-Ray Computed/standards , Adult , Aged , Aged, 80 and over , Betacoronavirus , COVID-19 , Female , Hospitals, University , Humans , Male , Middle Aged , Pandemics , Predictive Value of Tests , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Sensitivity and Specificity
...