Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38864730

RESUMEN

AIMS: Patients with structural heart disease (SHD) undergoing catheter ablation (CA) for ventricular tachycardia (VT) are at considerable risk of periprocedural complications, including acute haemodynamic decompensation (AHD). The PAINESD score was proposed to predict the risk of AHD. The goal of this study was to validate the PAINESD score using the retrospective analysis of data from a large-volume heart centre. METHODS AND RESULTS: Patients who had their first radiofrequency CA for SHD-related VT between August 2006 and December 2020 were included in the study. Procedures were mainly performed under conscious sedation. Substrate mapping/ablation was performed primarily during spontaneous rhythm or right ventricular pacing. A purposely established institutional registry for complications of invasive procedures was used to collect all periprocedural complications that were subsequently adjudicated using the source medical records. Acute haemodynamic decompensation triggered by CA procedure was defined as intraprocedural or early post-procedural (<12 h) development of acute pulmonary oedema or refractory hypotension requiring urgent intervention. The study cohort consisted of 1124 patients (age, 63 ± 13 years; males, 87%; ischaemic cardiomyopathy, 67%; electrical storm, 25%; New York Heart Association Class, 2.0 ± 1.0; left ventricular ejection fraction, 34 ± 12%; diabetes mellitus, 31%; chronic obstructive pulmonary disease, 12%). Their PAINESD score was 11.4 ± 6.6 (median, 12; interquartile range, 6-17). Acute haemodynamic decompensation complicated the CA procedure in 13/1124 = 1.2% patients and was not predicted by PAINESD score with AHD rates of 0.3, 1.8, and 1.1% in subgroups by previously published PAINESD terciles (<9, 9-14, and >14). However, the PAINESD score strongly predicted mortality during the follow-up. CONCLUSION: Primarily substrate-based CA of SHD-related VT performed under conscious sedation is associated with a substantially lower rate of AHD than previously reported. The PAINESD score did not predict these events. The application of the PAINESD score to the selection of patients for pre-emptive mechanical circulatory support should be reconsidered.


Asunto(s)
Ablación por Catéter , Hemodinámica , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Estudios Retrospectivos , Cicatriz/fisiopatología , Anciano , Hipotensión/etiología , Hipotensión/fisiopatología , Hipotensión/diagnóstico , Edema Pulmonar/etiología , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/diagnóstico , Factores de Riesgo
3.
Am J Cardiol ; 208: 156-163, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37839172

RESUMEN

Plasma natriuretic peptides (NPs) are increased in patients with atrial fibrillation (AF) compared with the patients with sinus rhythm. This study investigated whether this phenomenon is intrinsic to heart rhythm irregularity and independent of the heart rate and left atrial pressure (LAP) overload. We investigated 46 patients (age: 59 ± 10 years, male gender: 77%) with non-valvular paroxysmal AF who were scheduled for catheter ablation and had documented stable sinus rhythm for at least 18 hours before the procedure. All patients underwent direct measurement of right atrial pressure and LAP, simultaneously with assessment of plasma B-type NP, N-terminal pro-brain NP, and mid-regional pro-atrial NP. The baseline measurement was followed by induction of AF by rapid atrial pacing in the first 24 patients and by regular pacing from the coronary sinus at 100/min (corresponding to the mean heart rate during induced AF) in the latter 22 patients. Hemodynamic assessment and blood sampling were repeated after 20 min of the ongoing AF or fast regular paging. The baseline characteristics and hemodynamic measurements were comparable between study groups; however, patients in the regular atrial pacing group had a higher body mass index and a larger left atrial diameter compared with the induced AF group. Plasma levels of all 3 NPs increased significantly during induced AF but not during fast regular pacing, and the increase of NPs was independent of right atrial pressure and LAP. Baseline concentrations of NPs and heart rhythm irregularity were the only independent predictors of increased NPs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Masculino , Persona de Mediana Edad , Anciano , Frecuencia Cardíaca , Presión Atrial/fisiología , Péptidos Natriuréticos , Atrios Cardíacos , Ablación por Catéter/métodos
5.
J Cardiovasc Electrophysiol ; 33(12): 2569-2577, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36069129

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) is the most common sustained arrhythmia in humans. The onset of the arrhythmia can significantly impair cardiac function. This hemodynamic deterioration has been explained by several mechanisms such as the loss of atrial contraction, shortening of ventricular filling, or heart rhythm irregularity. This study sought to evaluate the relative hemodynamic contribution of each of these components during in vivo simulated human AF. METHODS: Twelve patients undergoing catheter ablation for paroxysmal AF were paced simultaneously from the proximal coronary sinus and the His bundle region according to prescribed sequences of irregular R-R intervals with the average rate of 90 and 130 bpm, which were extracted from the database of digital ECG recordings of AF from other patients. The simulated AF was compared to regular atrial pacing with spontaneous atrioventricular conduction and regular simultaneous atrioventricular pacing at the same heart rate. Beat-by-beat left atrial and left ventricular pressures, including LV dP/dT and Tau index were assessed by direct invasive measurement; beat-by-beat stroke volume and cardiac output (index) were assessed by simultaneous pulse-wave doppler intracardiac echocardiography. RESULTS: Simulated AF led to significant impairment of left ventricular systolic and diastolic function. Both loss of atrial contraction and heart rate irregularity significantly contributed to hemodynamic impairment. This effect was pronounced with increasing heart rate. CONCLUSION: Our findings strengthen the rationale for therapeutic strategies aiming at rhythm control and heart rate regularization in patients with AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Función Ventricular Izquierda , Ablación por Catéter/efectos adversos , Hemodinámica , Frecuencia Cardíaca , Estimulación Cardíaca Artificial
6.
JACC Clin Electrophysiol ; 8(7): 895-904, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35863816

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) by radiofrequency (RF) energy is associated with a collateral ganglionated plexi ablation. Pulsed electric field (PEF) is a nonthermal energy source that preferentially affects the myocardial cells and spares neural tissue. OBJECTIVES: This study investigated whether PVI by a PEF compared with RF energy will result in less prominent alteration of the cardiac autonomic nervous system. METHODS: A total of 31 patients with atrial fibrillation underwent PVI using a novel lattice-tip catheter and PEF energy (n = 18) or a conventional irrigated-tip catheter and RF energy (n = 13). The response of the sinoatrial node and atrioventricular node to extracardiac high-frequency, high-output, right vagal nerve stimulation was evaluated at baseline and during and at the end of the ablation procedure. Substantial reduction in responsiveness was arbitrarily defined as stimulation-inducible pause <1.5 seconds. RESULTS: Reduced response of the sinoatrial node was documented in 13 of 13 (100%) and 6 of 18 (33%) patients (P = 0.0001) in RF and PEF groups, respectively. Reduced response of the atrioventricular node was found in 10 of 11 (93%) and 6 of 18 (33%) patients (P = 0.002) in RF and PEF groups, respectively. The major effects were observed predominantly during ablation around the right pulmonary veins. Early recovery of ganglionated plexi function was noticed only in the PEF ablation group. RF ablation resulted in higher acceleration of the sinus rhythm compared with PEF ablation (20 ± 13 beats/min vs 12 ± 10 beats/min; P = 0.04). CONCLUSIONS: PEF compared with RF energy used for PVI induces significantly weaker and less durable suppression of cardiac autonomic regulations.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Sistema Nervioso Autónomo , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Venas Pulmonares/cirugía , Nodo Sinoatrial
7.
Europace ; 24(4): 598-605, 2022 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-34791165

RESUMEN

AIM: To describe clinical characteristics, procedural details, specific challenges, and outcomes in patients with HeartMate3™ (HM3), a left ventricular assist device system with a magnetically levitated pump, undergoing ventricular tachycardia ablation (VTA). METHODS AND RESULTS: Data were collected from patients with an HM3 system who underwent VTA in seven tertiary centres. Data included baseline patient characteristics, procedural data, mortality, and arrhythmia-free survival. The study cohort included 19 patients with cardiomyopathy presenting with ventricular tachycardia (VT) (53% with VT storm). Ventricular tachycardias were induced in 89% of patients and a total of 41 VTs were observed. Severe electromagnetic interference was present on the surface electrocardiogram. Hence, VT localization required analysis of intra-cardiac signals or the use of filter in the 40-20 Hz range. The large house pump HM3 design obscured the cannula inflow and therefore multi imaging modalities were necessary to avoid catheter entrapment in the cannula. A total of 32 VTs were mapped and were successfully ablated (31% to the anterior wall, 38% to the septum and only 9% to the inflow cannula region). Non-inducibility of any VT was reached in 11 patients (58%). Over a follow-up of 429 (interquartile range 101-692) days, 5 (26%) patients underwent a redo VT ablation due to recurrent VTA and 2 (11%) patients died. CONCLUSIONS: Ventricular tachycardia ablation in patients with HM3 is feasible and safe when done in the appropriate setup. Long-term arrhythmia-free survival is acceptable but not well predicted by non-inducibility at the end of the procedure.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Corazón Auxiliar , Taquicardia Ventricular , Cardiomiopatías/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Recurrencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 32(3): 647-656, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33428307

RESUMEN

AIMS: Catheter ablation (CA) for atrial fibrillation (AF) has a considerable risk of procedural complications. Major vascular complications (MVCs) appear to be the most frequent. This study investigated gender differences in MVCs in patients undergoing CA for AF in a high-volume tertiary center. METHODS: A total of 4734 CAs for AF (65% paroxysmal, 26% repeated procedures) were performed at our center between January 2006 and August 2018. Patients (71% males) aged 60 ± 10 years and had a body mass index of 29 ± 4 kg/m2 at the time of the procedure. Radiofrequency point-by-point ablation was employed in 96.3% of procedures with the use of three-dimensional navigation systems and facilitated by intracardiac echocardiography. Pulmonary vein isolation was mandatory; cavotricuspid isthmus and left atrial substrate ablation were performed in 22% and 38% procedures, respectively. MVCs were defined as those that resulted in permanent injury, required intervention, or prolonged hospitalization. Their rates and risk factors were compared between genders. RESULTS: A total of 112 (2.4%) MVCs were detected: 54/1512 (3.5%) in females and 58/3222 (1.8%) in males (p < .0001). On multivariate analysis, lower body height was the only risk factor for MVCs in females (p = .0005). On the contrary, advanced age was associated with MVCs in males (p = .006). CONCLUSION: Females have a higher risk of MVCs following CA for AF compared to males. This difference is driven by lower body size in females. Low body height in females and advanced age in males are independent predictors of MVCs. Ultrasound-guided venipuncture lowered the MVC rate in males.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Factores Sexuales , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...