1.
Microbiol Spectr ; 11(6): e0136923, 2023 Dec 12.
Article En | MEDLINE | ID: mdl-37909752

IMPORTANCE: Quantitative SARS-CoV-2 tests for viral load are necessary to guide patient treatment, as well as to determine infection control measures and policies. Although the real-time RT-PCR assays can report the Ct value to estimate the viral load, there are several serious concerns regarding the use of Ct values. Importantly, Ct values can vary significantly among between- and within-run methods. The diagnostic performance of the cobas SARS-CoV-2 Duo is appropriate. It is a precise, accurate, and sensitive method for the detection of SARS-CoV-2 RNA and is comparable to two qualitative assays (the cobas SARS-CoV-2 and the Liat cobas SARS-CoV-2 and Inf A/B). In contrast, using the Ct value to estimate viral load is not reliable, and utilization of a quantitative detection test, such as the cobas SARS-CoV-2 Duo, to accurately measure the viral load is needed.


COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , RNA, Viral/genetics , COVID-19 Testing/methods , Reagent Kits, Diagnostic
3.
Biomedicine (Taipei) ; 12(2): 40-46, 2022.
Article En | MEDLINE | ID: mdl-35836977

Objectives: This study examined analytical sensitivity, specificity, and the clinical performance in detecting SARS-CoV-2 of the Cobas SARS-CoV-2 Test based on the high-throughput Cobas 6800 system and the Cobas SARS-CoV-2 & Flu A/B Test based on the point-of-care cobas Liat system. Methods: The commercial reagents containing SARS-CoV-2 RNA subgenomes were diluted for assessing the sensitivity of the RT-qPCR assay. 385 nasopharyngeal swab specimens taken from contacts of COVID-19 cases were tested for the SARS-CoV-2 detection with both Cobas SARS-CoV-2 Tests. Results: In analytical sensitivity assays, the Cobas SARS-CoV-2 & Flu A/B Test on the Liat system had a lower limit of detection (12.5-25 copies/mL) than the cobas SARS-CoV-2 Test on the cobas 6800 system (25-50 copies/mL). In clinical performance assays, the cobas SARS-CoV-2 Test demonstrated 89.36% (42 out of 47) PPA (positive percent agreement) and 98.82% (334 out of 338) NPA (negative percent agreement) compared to the results of the Cobas SARS-CoV-2 & Flu A/B test. Among five discordant specimens, four had the positive result of the cobas SARS-CoV-2 test, but the negative result of the cobas SARS-CoV-2 & Flu A/B Test. Moreover, these discordant specimens had the Ct values of greater than 33 for the cobas SARS-CoV-2 Test, implying a very small number of virions in the samples. Remarkably, four specimens with a presumptive positive result of the cobas SARS-CoV-2 test had been confirmed by the Cobas SARS-CoV-2 & Flu A/B Test. Next, the scatter plots of the Ct values showed a highly positive correlation between cobas SARS-CoV-2 & Flu A/B Test and the cobas SARS-CoV-2 Test (R-squared value = 0.954-0.962). Conclusions: Both SARS-CoV2 tests of the cobas 6800 and Liat systems produce reliable high throughput and point-of-care assays respectively for the early virus detection and the personal care decision-making during COVID-19 pandemic.

...