Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
J Nucl Med Technol ; 52(2): 152-157, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839118

RESUMEN

The National Cyclotron and PET Centre at Chulabhorn Hospital offers nuclear medicine diagnostic services using state-of-the-art digital PET/CT and PET/MRI machines as well as other related devices. Additionally, the center plays a vital role by having a cyclotron to produce radiopharmaceuticals, which are used both in-house and in other hospitals throughout the country. Despite the center's strict adherence to international standards regarding the use of radioactive substances in patients, there remains a potential risk of radiation exposure for operators, workers, and the public due to radioactive contamination and emissions from unsealed sources. Hence, it is imperative to assess and continuously monitor radiation levels in the work area to ensure the utmost level of safety for personnel. Methods: This study used optically stimulated luminescence dosimeters to measure radiation levels in 17 areas, consisting of 9 controlled and 8 supervised areas. Over a 3-mo period, the average monthly radiation dose was recorded for each location. Results: The PET/CT room registered the highest radiation dose within the controlled area, with a monthly average of 1.81 ± 0.29 mSv, equivalent to an annual dose of 21.72 mSv. This higher dose can be attributed to the significant number of patients served in this room. In supervised areas, the nursing counter located between the examination room and the patient waiting area exhibited the highest radiation exposure. The average monthly dose measured at this location was 0.085 ± 0.019 mSv, resulting in an annual dose of 1.015 mSv. Conclusion: The evaluation of radiation dose in controlled and supervised areas indicated that the overall radiation level remains within the prescribed limits. However, the slight excess that was observed at the nursing counter indicates the need for improvement to ensure compliance with the as-low-as-reasonably-achievable principle. Continuous monitoring of radiation levels should be conducted annually to maintain safety standards and minimize the risk that workers and the general public will be exposed to radioactivity.


Asunto(s)
Ciclotrones , Hospitales , Tomografía de Emisión de Positrones , Dosis de Radiación , Tailandia , Humanos , Exposición Profesional/análisis , Exposición Profesional/prevención & control
2.
J Imaging ; 9(12)2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38132682

RESUMEN

Computed tomography examinations have caused high radiation doses for patients, especially for CT scans of the brain. This study aimed to optimize the radiation dose and image quality in adult brain CT protocols. Images were acquired using a Catphan 700 phantom. Radiation doses were recorded as CTDIvol and dose length product (DLP). CT brain protocols were optimized by varying parameters such as kVp, mAs, signal-to-noise ratio (SNR) level, and Clearview iterative reconstruction (IR). The image quality was also evaluated using AutoQA Plus v.1.8.7.0 software. CT number accuracy and linearity had a robust positive correlation with the linear attenuation coefficient (µ) and showed more inaccurate CT numbers when using 80 kVp. The modulation transfer function (MTF) showed a higher value in 100 and 120 kVp protocols (p < 0.001), while high-contrast spatial resolution showed a higher value in 80 and 100 kVp protocols (p < 0.001). Low-contrast detectability and the contrast-to-noise ratio (CNR) tended to increase when using high mAs, SNR, and the Clearview IR protocol. Noise decreased when using a high radiation dose and a high percentage of Clearview IR. CTDIvol and DLP were increased with increasing kVp, mAs, and SNR levels, while the increasing percentage of Clearview did not affect the radiation dose. Optimized protocols, including radiation dose and image quality, should be evaluated to preserve diagnostic capability. The recommended parameter settings include kVp set between 100 and 120 kVp, mAs ranging from 200 to 300 mAs, SNR level within the range of 0.7-1.0, and an iterative reconstruction value of 30% Clearview to 60% or higher.

3.
J Food Biochem ; 46(4): e13909, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34423456

RESUMEN

This study aims to investigate the effect of Polygonum odoratum leaf extract (POE) on oxidative stress markers and cell death induced by low dose ionizing radiation (LDIR) in Raw 264.7 cells. The biological activities, chromatographic fingerprint, and cytotoxicity of POE were investigated. To determine the radioprotective effect of POE, Raw 264.7 cells were incubated with POE for 1 hr prior to 100 mGy x-irradiation. The cell viability, oxidative stress damage marker (malondialdehyde level; MDA), and endogenous antioxidant markers (superoxide dismutase: SOD, catalase: CAT, and glutathione peroxidase: GSH-Px) were also determined. The results showed that POE contained 8 essential substances and exhibited a potent antioxidant without any cytotoxicity. It was found that POE significantly decreased the MDA level and activated cell viability, SOD, CAT, and GSH-Px activities. The results from this study indicate that POE is a potent antioxidant, which can be developed as a radioprotector for diagnostic procedures. PRACTICAL APPLICATIONS: Polygonum odoratum leaf extract (POE) is a potent antioxidant that attenuates oxidative stress and cell death induced by low dose ionizing radiation (LDIR). POE might protect against cell damage from LDIR, particularly in diagnostic radiology procedures. Therefore, the development of functional food containing POE might be beneficial for patients who plan to undergo the diagnostic radiology procedure. The functional food containing POE might prevent stochastic and deterministic effects for these patients.


Asunto(s)
Antioxidantes , Estrés Oxidativo , Extractos Vegetales , Polygonum , Animales , Antioxidantes/metabolismo , Antioxidantes/farmacología , Muerte Celular , Ratones , Extractos Vegetales/química , Extractos Vegetales/farmacología , Polygonum/química , Células RAW 264.7 , Radiación Ionizante , Superóxido Dismutasa/metabolismo
4.
J Radiol Prot ; 40(4)2020 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-33226005

RESUMEN

In 2018, the International Radiation Protection Association (IRPA) established its third task group (TG) on the implementation of the eye lens dose limit. To contribute to sharing experience and raising awareness within the radiation protection community about protection of workers in exposure of the lens of the eye, the TG conducted a questionnaire survey and analysed the responses. This paper provides an overview of the results of the questionnaire.


Asunto(s)
Cristalino , Exposición Profesional , Protección Radiológica , Humanos , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Dosis de Radiación , Investigación
5.
Phys Med ; 44: 232-235, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29054516

RESUMEN

PURPOSE: To determine the eye lens dose of the Interventional Cardiology (IC) personnel using optically stimulated luminescent dosimeter (OSLD) and the prevalence and risk of radiation - associated lens opacities in Thailand. METHODS AND RESULTS: 48 IC staff, with age- and sex- matches 37 unexposed controls obtained eye examines. Posterior lens change was graded using a modified Merriam-Focht technique by two independent ophthalmologists. Occupational exposure (mSv) was measured in 42 IC staff, using 2 OSLD badges place at inside lead apron and at collar. Annual eye lens doses (mSv) were also measured using 4 nanoDots OSL placed outside and inside lead glass eyewear. The prevalence of radiation-associated posterior lens opacities was 28.6% (2/7) for IC, 19.5% (8/41) for nurses, and 2.7% (1/37) for controls. The average and range of annual whole body effective dose, Hp(10), equivalent dose at skin of the neck, Hp(0.07) and equivalent dose at eye lens, Hp(3) were 0.80 (0.05-6.79), 5.88 (0.14-35.28), and 5.73 (0.14-33.20) mSv respectively. The annual average and range of eye lens dose using nano Dots OSL showed the outside lead glass eyewear on left and right sides as 8.06 (0.17-32.45), 3.55(0.06-8.04) mSv and inside left and right sides as 3.91(0.05-14.26) and 2.44(0.06-6.24) mSv respectively. CONCLUSION: Eye lens doses measured by OSLD badges and nano Dot dosimeter as Hp(10), Hp(0.07) and Hp(3). The eyes of the IC personnel were examined annually by two ophthalmologists for the prevalence of cataract induced by radiation.


Asunto(s)
Cardiología , Catarata/etiología , Personal de Salud , Cristalino/efectos de la radiación , Exposición Profesional/efectos adversos , Exposición Profesional/análisis , Traumatismos por Radiación/etiología , Humanos , Protección Radiológica , Radiometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA