Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
J Clin Anesth ; 98: 111582, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39167880

RESUMEN

ChatGPT4 is a leading large language model (LLM) chatbot released by OpenAI in 2023. ChatGPT4 can respond to free-text queries, answer questions and make suggestions regarding virtually any topic. ChatGPT4 has successfully answered anesthesia and even obstetric anesthesia knowledge-based questions with reasonable accuracy. However, ChatGPT4 has yet to be challenged in obstetric anesthesia clinical decision-making. STUDY OBJECTIVE: In this study, we evaluated the performance of ChatGPT4 in the management of clinical labor analgesia scenarios compared to expert obstetric anesthesiologists. INTERVENTION: Eight clinical questions with progressively increasing medical complexity were posed to ChatGPT4. MEASUREMENTS: The ChatGPT4 responses were rated by seven expert obstetric anesthesiologists based on safety, accuracy and completeness of each response using a five-point Likert rating scale. MAIN RESULTS: ChatGPT4 was deemed safe in 73% of responses to the presented obstetric anesthesia clinical scenarios (27% of responses were deemed unsafe). None of the ChatGPT4 responses were unanimously deemed to be safe by all seven expert obstetric anesthesiologists. Moreover, ChatGPT4 responses were overall partly accurate (score 4 out of 5) and somewhat incomplete (score 3.5 out of 5). CONCLUSIONS: In summary, approximately one quarter of all responses by ChatGPT4 were deemed unsafe by expert obstetric anesthesiologists. These findings may suggest the need for more fine-tuning and training of LLMs such as ChatGPT4 specifically for clinical decision making in obstetric anesthesia or other specialized medical fields. These LLMs may come to play an important future role in assisting obstetric anesthesiologists in clinical decision making and enhancing overall patient care.


Asunto(s)
Analgesia Obstétrica , Dolor de Parto , Aprendizaje Automático , Manejo del Dolor , Femenino , Analgesia Obstétrica/métodos , Dolor de Parto/terapia , Manejo del Dolor/métodos , Humanos
2.
BJA Open ; 10: 100296, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38975242

RESUMEN

Background: The expansion of artificial intelligence (AI) within large language models (LLMs) has the potential to streamline healthcare delivery. Despite the increased use of LLMs, disparities in their performance particularly in different languages, remain underexplored. This study examines the quality of ChatGPT responses in English and Japanese, specifically to questions related to anaesthesiology. Methods: Anaesthesiologists proficient in both languages were recruited as experts in this study. Ten frequently asked questions in anaesthesia were selected and translated for evaluation. Three non-sequential responses from ChatGPT were assessed for content quality (accuracy, comprehensiveness, and safety) and communication quality (understanding, empathy/tone, and ethics) by expert evaluators. Results: Eight anaesthesiologists evaluated English and Japanese LLM responses. The overall quality for all questions combined was higher in English compared with Japanese responses. Content and communication quality were significantly higher in English compared with Japanese LLMs responses (both P<0.001) in all three responses. Comprehensiveness, safety, and understanding were higher scores in English LLM responses. In all three responses, more than half of the evaluators marked overall English responses as better than Japanese responses. Conclusions: English LLM responses to anaesthesia-related frequently asked questions were superior in quality to Japanese responses when assessed by bilingual anaesthesia experts in this report. This study highlights the potential for language-related disparities in healthcare information and the need to improve the quality of AI responses in underrepresented languages. Future studies are needed to explore these disparities in other commonly spoken languages and to compare the performance of different LLMs.

3.
Anesth Analg ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38917035

RESUMEN

The Gerard W. Ostheimer lecture is given annually to members of the Society for Obstetric Anesthesia and Perinatology. This lecture summarizes new and emerging literature that informs the clinical practice of obstetric anesthesiology. This is a narrative review of 2022 literature pertinent to maternal morbidity and mortality in all income settings globally. Themes associated with worse maternal mortality rate (MMR), challenges health care workers face, public health priority areas, and initiatives to help countries achieve the United Nations Sustainable Development Goal targets for MMR are discussed. MMRs are higher in low- and middle-income countries (LMICs) compared to high-income countries (HICs). Cesarean delivery rates are rising most rapidly in LMICs, warranting urgent maternal health care workforce planning efforts in these settings. Globally racial, ethnic, and geographical disparities in maternal mortality continue to be evident in global health care settings. In the United States, the MMR is rising. The evolving changes in abortion legislation in the United States may further negatively impact maternal morbidity and mortality. The need to implement American Society of Anesthesiologists-recommended obstetric anesthesia quality metrics to facilitate benchmarking and to improve patient experience and outcomes is discussed as well as the need for professional society guidance on minimum staffing levels in American labor and delivery units.

4.
BJA Open ; 10: 100280, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38764485

RESUMEN

Background: Patients are increasingly using artificial intelligence (AI) chatbots to seek answers to medical queries. Methods: Ten frequently asked questions in anaesthesia were posed to three AI chatbots: ChatGPT4 (OpenAI), Bard (Google), and Bing Chat (Microsoft). Each chatbot's answers were evaluated in a randomised, blinded order by five residency programme directors from 15 medical institutions in the USA. Three medical content quality categories (accuracy, comprehensiveness, safety) and three communication quality categories (understandability, empathy/respect, and ethics) were scored between 1 and 5 (1 representing worst, 5 representing best). Results: ChatGPT4 and Bard outperformed Bing Chat (median [inter-quartile range] scores: 4 [3-4], 4 [3-4], and 3 [2-4], respectively; P<0.001 with all metrics combined). All AI chatbots performed poorly in accuracy (score of ≥4 by 58%, 48%, and 36% of experts for ChatGPT4, Bard, and Bing Chat, respectively), comprehensiveness (score ≥4 by 42%, 30%, and 12% of experts for ChatGPT4, Bard, and Bing Chat, respectively), and safety (score ≥4 by 50%, 40%, and 28% of experts for ChatGPT4, Bard, and Bing Chat, respectively). Notably, answers from ChatGPT4, Bard, and Bing Chat differed statistically in comprehensiveness (ChatGPT4, 3 [2-4] vs Bing Chat, 2 [2-3], P<0.001; and Bard 3 [2-4] vs Bing Chat, 2 [2-3], P=0.002). All large language model chatbots performed well with no statistical difference for understandability (P=0.24), empathy (P=0.032), and ethics (P=0.465). Conclusions: In answering anaesthesia patient frequently asked questions, the chatbots perform well on communication metrics but are suboptimal for medical content metrics. Overall, ChatGPT4 and Bard were comparable to each other, both outperforming Bing Chat.

5.
BMC Pregnancy Childbirth ; 24(1): 366, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750438

RESUMEN

BACKGROUND: The potential effect modification of sleep on the relationship between anxiety and elevated blood pressure (BP) in pregnancy is understudied. We evaluated the relationship between anxiety, insomnia, and short sleep duration, as well as any interaction effects between these variables, on BP during pregnancy. METHODS: This was a prospective pilot cohort of pregnant people between 23 to 36 weeks' gestation at a single institution between 2021 and 2022. Standardized questionnaires were used to measure clinical insomnia and anxiety. Objective sleep duration was measured using a wrist-worn actigraphy device. Primary outcomes were systolic (SBP), diastolic (DBP), and mean (MAP) non-invasive BP measurements. Separate sequential multivariable linear regression models fit with generalized estimating equations (GEE) were used to separately assess associations between anxiety (independent variable) and each BP parameter (dependent variables), after adjusting for potential confounders (Model 1). Additional analyses were conducted adding insomnia and the interaction between anxiety and insomnia as independent variables (Model 2), and adding short sleep duration and the interaction between anxiety and short sleep duration as independent variables (Model 3), to evaluate any moderating effects on BP parameters. RESULTS: Among the 60 participants who completed the study, 15 (25%) screened positive for anxiety, 11 (18%) had subjective insomnia, and 34 (59%) had objective short sleep duration. In Model 1, increased anxiety was not associated with increases in any BP parameters. When subjective insomnia was included in Model 2, increased DBP and MAP was significantly associated with anxiety (DBP: ß 6.1, p = 0.01, MAP: ß 6.2 p < 0.01). When short sleep was included in Model 3, all BP parameters were significantly associated with anxiety (SBP: ß 9.6, p = 0.01, DBP: ß 8.1, p < 0.001, and MAP: ß 8.8, p < 0.001). No moderating effects were detected between insomnia and anxiety (p interactions: SBP 0.80, DBP 0.60, MAP 0.32) or between short sleep duration and anxiety (p interactions: SBP 0.12, DBP 0.24, MAP 0.13) on BP. CONCLUSIONS: When including either subjective insomnia or objective short sleep duration, pregnant people with anxiety had 5.1-9.6 mmHg higher SBP, 6.1-8.1 mmHg higher DBP, and 6.2-8.8 mmHg higher MAP than people without anxiety.


Asunto(s)
Ansiedad , Presión Sanguínea , Trastornos del Inicio y del Mantenimiento del Sueño , Humanos , Femenino , Embarazo , Proyectos Piloto , Estudios Prospectivos , Adulto , Presión Sanguínea/fisiología , Trastornos del Inicio y del Mantenimiento del Sueño/psicología , Trastornos del Inicio y del Mantenimiento del Sueño/epidemiología , Sueño/fisiología , Complicaciones del Embarazo/psicología , Encuestas y Cuestionarios , Actigrafía
6.
Anesth Analg ; 138(6): e37-e38, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38771606

Asunto(s)
Humanos
7.
Obstet Gynecol ; 143(6): 803-810, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38663016

RESUMEN

OBJECTIVE: To evaluate whether antepartum hospitalization was associated with differences in sleep duration or disrupted sleep patterns. METHODS: This was a prospective cohort study with enrollment of pregnant people aged 18-55 years with singleton gestations at 16 weeks of gestation or more between 2021 and 2022. Each enrolled antepartum patient was matched by gestational age to outpatients recruited from obstetric clinics at the same institution. Participants responded to the ISI (Insomnia Severity Index) and wore actigraph accelerometer watches for up to 7 days. The primary outcome was total sleep duration per 24 hours. Secondary outcomes included sleep efficiency (time asleep/time in bed), ISI score, clinical insomnia (ISI score higher than 15), short sleep duration (less than 300 minutes/24 hours), wakefulness after sleep onset, number of awakenings, and sleep fragmentation index. Outcomes were evaluated with multivariable generalized estimating equations adjusted for body mass index (BMI), sleep aid use, and insurance type, accounting for gestational age correlations. An interaction term assessed the joint effects of time and inpatient status. RESULTS: Overall 58 participants were included: 18 inpatients and 40 outpatients. Inpatients had significantly lower total sleep duration than outpatients (mean 4.4 hours [SD 1.6 hours] inpatient vs 5.2 hours [SD 1.5 hours] outpatient, adjusted ß=-1.1, 95% CI, -1.8 to -0.3, P =.01). Awakenings (10.1 inpatient vs 13.8, P =.01) and wakefulness after sleep onset (28.3 inpatient vs 35.5 outpatient, P =.03) were lower among inpatients. There were no differences in the other sleep outcomes, and no interaction was detected for time in the study and inpatient status. Inpatients were more likely to use sleep aids (39.9% vs 12.5%, P =.03). CONCLUSION: Hospitalized pregnant patients slept about 1 hour/day less than outpatients. Fewer awakenings and reduced wakefulness after sleep onset among inpatients may reflect increased use of sleep aids in hospitalized patients.


Asunto(s)
Pacientes Internos , Pacientes Ambulatorios , Humanos , Femenino , Embarazo , Adulto , Estudios Prospectivos , Pacientes Ambulatorios/estadística & datos numéricos , Adulto Joven , Pacientes Internos/estadística & datos numéricos , Complicaciones del Embarazo , Adolescente , Trastornos del Inicio y del Mantenimiento del Sueño , Persona de Mediana Edad , Sueño/fisiología , Hospitalización/estadística & datos numéricos , Actigrafía
8.
BJA Open ; 10: 100269, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38560622

RESUMEN

Background: Spanish is the second most spoken language globally with around 475 million native speakers. We aimed to validate a Spanish version of the Obstetric Quality of Recovery-10 item (ObsQoR-10) patient-reported outcome measure. Methods: ObsQoR-10-Spanish was developed using EuroQoL methodology. ObsQoR-10-Spanish was assessed in 100 Spanish-speaking patients undergoing elective Caesarean or vaginal delivery. Patients <38 weeks, undergoing an intrapartum Caesarean delivery, intrauterine death, or maternal admission to the intensive care unit (ICU) were excluded. Validity was assessed by evaluating (i) convergent validity-correlation with 24-h EuroQoL and global health visual analogue scale (GHVAS) scores (0-100); (ii) discriminant validity-difference in ObsQoR-10-Spanish score for patients with GHVAS scores >70 vs <70; (iii) hypothesis testing-correlation of ObsQoR score with maternal and neonatal factors; and (iv) cross-cultural validity assessed using differential item functioning analysis. Reliability was assessed by evaluating: (i) internal consistency; (ii) split-half reliability and (iii) test-retest reliability; and (iv) floor and ceiling effects. Results: One hundred patients were approached, recruited, and completed surveys. Validity: (i) convergent validity: the ObsQoR 24-h score correlated moderately with the 24-h EuroQoL (r=-0.632) and GHVAS scores (r=0.590); (ii) discriminant validity: the ObsQoR-10-Spanish 24-h scores were higher in women who delivered vaginally compared to via Caesarean delivery, (mean [standard deviation] scores were 89 [9] vs 81 [12]; P<0.001). The 24-h ObsQoR-Spanish scores were lower in patients experiencing a poor vs a good recovery (mean [standard deviation] scores were 76 [12.3] vs 87.1 [10.6]; P=0.001); (iii) hypothesis testing: the ObsQoR-10 score correlated negatively with age (r=-0.207) and positively with 5-min (r=0.204) and 10-min (r=0.243) Apgar scores. Remaining correlations were not significant; and (iv) differential item functioning analysis suggested no potential bias among the 10 items. Reliability: (i) internal consistency was good (Cronbach alpha=0.763); (ii) split-half reliability was good (Spearman-Brown prophesy reliability estimate of 0.866); (iii) test-retest reliability was excellent with an intra-class correlation coefficient of 0.90; and (iv) floor and ceiling effects: six patients scored a maximum total ObsQoR-10 score. Conclusions: The ObsQoR-10-Spanish patient-reported outcome measure is valid, reliable, and clinically feasible, and should be considered for use in Spanish-speaking women to assess quality of inpatient postpartum recovery.

9.
Eur J Obstet Gynecol Reprod Biol ; 297: 8-14, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38554481

RESUMEN

OBJECTIVE: Physical activity is linked to lower anxiety, but little is known about the association during pregnancy. This is especially important for antepartum inpatients, who are known to have increased anxiety yet may not be able to achieve target levels of physical activity during hospitalization. We compared physical activity metrics between pregnant inpatients and outpatients and explored correlations with anxiety. MATERIALS AND METHODS: This was a prospective cohort between 2021 and 2022 of pregnant people aged 18-55 years carrying singleton gestations ≥ 16 weeks. Three exposure groups were matched for gestational age: 1) outpatients from general obstetric clinics; 2) outpatients from high-risk Maternal-Fetal Medicine obstetric clinics; and 3) antepartum inpatients. Participants wore Actigraph GT9X Link accelerometer watches for up to 7 days to measure physical activity. The primary outcome was mean daily step count. Secondary outcomes were metabolic equivalent tasks (METs), hourly kilocalories (kcals), moderate to vigorous physical activity (MVPA) bursts, and anxiety (State-Trait Anxiety Inventory [STAI]). Step counts were compared using multivariable generalized estimating equations adjusting for maternal age, body-mass index, and insurance type as a socioeconomic construct, accounting for within-group clustering by gestational age. Spearman correlations were used to correlate anxiety scores with step counts. RESULTS: 58 participants were analyzed. Compared to outpatients, inpatients had significantly lower mean daily steps (primary outcome, adjusted beta -2185, 95 % confidence interval [CI] -3146, -1224, p < 0.01), METs (adjusted beta -0.18, 95 % CI -0.23, -0.13, p < 0.01), MVPAs (adjusted beta -38.2, 95 % CI -52.3, -24.1, p < 0.01), and kcals (adjusted beta -222.9, 95 % CI -438.0, -7.8, p = 0.04). Over the course of the week, steps progressively decreased for inpatients (p-interaction 0.01) but not for either of the outpatient groups. Among the entire cohort, lower step counts correlated with higher anxiety scores (r = 0.30, p = 0.02). CONCLUSION: We present antenatal population norms and variance for step counts, metabolic equivalent tasks, moderate to vigorous physical activity bursts, and kcals, as well as correlations with anxiety. Antepartum inpatients had significantly lower physical activity than outpatients, and lower step counts correlated with higher anxiety levels. These results highlight the need for physical activity interventions, particularly for hospitalized pregnant people.


Asunto(s)
Ansiedad , Ejercicio Físico , Humanos , Femenino , Embarazo , Adulto , Estudios Prospectivos , Ejercicio Físico/psicología , Adulto Joven , Pacientes Internos/psicología , Pacientes Internos/estadística & datos numéricos , Pacientes Ambulatorios/estadística & datos numéricos , Adolescente , Persona de Mediana Edad , Complicaciones del Embarazo/psicología
10.
BJA Educ ; 24(3): 81-83, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38375491
12.
BJA Open ; 9: 100242, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38179106

RESUMEN

Background: The role of continuous wound infusion catheters as part of a multimodal analgesia strategy after Caesarean delivery is unclear. We introduced continuous wound infusion catheters to our multimodal analgesia regimen to evaluate the impact on analgesic outcomes after Caesarean delivery. Methods: After institutional review board (IRB) approval, a 4-month practice change was instituted as a quality improvement initiative. In addition to multimodal analgesia, continuous wound infusion catheters for up to 3 days were offered on alternate weeks for all women undergoing Caesarean deliveries. The primary outcome was postoperative in-hospital opioid consumption. Secondary outcomes were static and dynamic pain scores at 24 and 72 h, time until first analgesic request, opioid-related side-effects, length of stay, satisfaction (0-100%), and continuous wound infusion catheter-related complications. Results: All women scheduled for Caesarean delivery (n=139) in the 4-month period were included in the analysis, with 70 women receiving continuous wound infusion catheters, and 69 in the control group. Opioid consumption (continuous wound infusion catheter group 11.3 [7.5-61.9] mg morphine equivalents vs control group 30.0 [11.3-48.8] mg morphine equivalents), pain scores (except 24 h resting pain scores which were higher in the control group 2 [1-3] vs 1.5 [0-3] in the continous wound infusion catheters group; P=0.05), side-effects, length of stay, and complications were similar between groups. Satisfaction scores at 24 h were higher with continuous wound infusion catheters (100% [91-100%] vs 90% [86-100%]; P=0.003) with no differences at 72 h. One patient demonstrated symptoms of systemic local anaesthetic toxicity which resolved without significant harm. Conclusions: The addition of continuous wound infusion catheters to a multimodal analgesia regimen for post-Caesarean delivery pain management demonstrated minimal clinically significant analgesic benefits. Future studies are needed to explore the use of continuous wound infusion catheters in populations that may benefit most from this intervention.

13.
J Clin Anesth ; 91: 111263, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37717463

RESUMEN

STUDY OBJECTIVE: To explore the relationship between Obstetric Quality of Recovery survey (ObsQoR-10-Heb) and Edinburgh postnatal depression scale (EPDS) measured 6 weeks after delivery, adjusted for potential confounding factors. DESIGN: Prospective, longitudinal cohort study. SETTING: Large postpartum department, 13,000 annual deliveries, quaternary medical center in Israel. PATIENTS: Women ≥18 years old, gestational age ≥ 37 weeks after term delivery (spontaneous vaginal, operative vaginal, planned, and unplanned cesarean delivery), with non-anomalous neonates not requiring special support after delivery or at the time of recruitment. Written informed consent was provided. Women unable to read or understand Hebrew were excluded. INTERVENTIONS: No interventions were done. MEASUREMENTS: We investigated the relationship between inpatient postpartum recovery and positive postpartum depression (PPD) screening at 6 weeks postpartum. Enrolled women completed the validated Hebrew version of ObsQoR-10 survey (ObsQoR-10-Heb; scored between 0 and 100 with 0 and 100 representing worst and best possible recovery) from 24 to 48 h after delivery, and the Edinburgh Postnatal Depression Scale (EPDS) at 6- and 12 weeks postpartum. We assessed the univariate association between ObsQoR-10-Heb; patient factors; obstetric factors; and positive PPD screening at 6 weeks postpartum. Potential confounders were adjusted in a multiple logistic regression model. MAIN RESULTS: Inpatient ObsQoR-10-Heb has been completed by 325 postpartum women; 270 (83.1%) and 253 (77.9%) completed the 6- and 12 weeks EPDS respectively. Lower ObsQoR-10-Heb (aOR 0.95 (95% CI 0.92, 0.98); p = 0.001); depression or anxiety before delivery (aOR 4.53 (95% CI 1.88, 10.90); p = 0.001); and hospital readmission (aOR 9.08 (95% CI 1.23, 67.14); p = 0.031) were associated with positive screening for postpartum depression at 6 weeks. CONCLUSIONS: Our study demonstrates that worse inpatient postpartum recovery is an independent risk factor for positive PPD screening at 6 weeks postpartum. Other risk factors found in our study were maternal hospital readmission and a previous history of anxiety or depression.


Asunto(s)
Depresión Posparto , Adolescente , Femenino , Humanos , Lactante , Recién Nacido , Embarazo , Factores de Transcripción con Motivo Hélice-Asa-Hélice Básico , Depresión Posparto/diagnóstico , Pacientes Internos , Estudios Longitudinales , Periodo Posparto , Estudios Prospectivos , Factores de Riesgo , Adulto Joven , Adulto
14.
JAMA Netw Open ; 6(8): e2326710, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37526934

RESUMEN

Importance: Dural-puncture epidural (DPE) and standard epidural are common modes of neuraxial labor analgesia. Little is known about conversion of DPE-initiated labor analgesia to surgical anesthesia for cesarean delivery. Objective: To determine whether DPE provides a faster onset and better-quality block compared with the standard epidural technique for cesarean delivery. Design, Setting, and Participants: This double-blind, randomized clinical trial was conducted between April 2019 and October 2022 at a tertiary care university hospital (University of Arkansas for Medical Sciences). Participants included women aged 18 years and older undergoing scheduled cesarean delivery with a singleton pregnancy. Interventions: Participants were randomized to receive DPE or standard epidural in the labor and delivery room. A T10 sensory block was achieved and maintained using a low concentration of bupivacaine with fentanyl through the epidural catheter until the time of surgery. Epidural extension anesthesia was initiated in the operating room. Main Outcomes and Measures: The primary outcome was the time taken from chloroprocaine administration to surgical anesthesia (T6 sensory block). The secondary outcome was the quality of epidural anesthesia, as defined by a composite of the following factors: (1) failure to achieve a T10 bilateral block preoperatively in the delivery room, (2) failure to achieve a surgical block at T6 within 15 minutes of chloroprocaine administration, (3) requirement for intraoperative analgesia, (4) repeat neuraxial procedure, and (5) conversion to general anesthesia. Results: Among 140 women (mean [SD] age, 30.1 [5.2] years), 70 were randomized to the DPE group, and 70 were randomized to the standard epidural group. The DPE group had a faster onset time to surgical anesthesia compared with the standard epidural group (median [IQR], 422 [290-546] seconds vs 655 [437-926] seconds; median [IQR] difference, 233 [104-369] seconds). The composite rates of lower quality anesthesia were 15.7% (11 of 70 women) in the DPE group and 36.3% (24 of 66 women) in the standard epidural group (odds ratio, 0.33; 95% CI, 0.14-0.74; P = .007). Conclusions and Relevance: Anesthesia initiated following a DPE technique resulted in faster onset and improved block quality during epidural extension compared with initiation with a standard epidural technique. Further studies are needed to confirm these findings in the setting of intrapartum cesarean delivery. Trial Registration: ClinicalTrials.gov Identifier: NCT03915574.


Asunto(s)
Analgesia Obstétrica , Anestesia Epidural , Trabajo de Parto , Embarazo , Femenino , Humanos , Adulto , Analgesia Obstétrica/métodos , Anestesia Epidural/métodos , Punciones
15.
Br J Anaesth ; 131(3): 556-571, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37455197

RESUMEN

BACKGROUND: Neuraxial opioids provide effective analgesia for Caesarean delivery, however, pruritus can be a troubling side-effect. Effective agents to prevent pruritus are needed. Our objective was to perform an updated systematic review and network meta-analysis to provide clinicians with a comparison of relative efficacy of available interventions to reduce the incidence of pruritus, induced by either intrathecal or epidural single-shot morphine, in women undergoing Caesarean delivery. METHODS: Databases systematically searched (up to January 2022) included PubMed MEDLINE, Web of Science, EBSCO CINAHL, Embase, LILACS, and two Cochrane databases. We included randomised, controlled trials involving adult female patients undergoing Caesarean delivery. We pooled trials comparing interventions used for preventing pruritus after Caesarean delivery and performed a Bayesian model network meta-analysis. RESULTS: The final primary network included data from comparisons of 14 distinct interventions (including placebo) used to reduce the incidence of pruritus in 6185 participants. We judged five interventions to be 'definitely superior' to placebo: propofol, opioid agonist-antagonists (neuraxial), opioid antagonists, opioid agonist-antagonists (systemic), and serotonin antagonists. For the network evaluating the incidence of severe pruritus (warranting additional therapeutic treatment of pruritus), data were available for 14 interventions (including placebo) in 4489 patients. For this outcome, we judged three interventions to be 'definitely superior' to placebo: dopamine antagonists (neuraxial) and systemic and neuraxial opioid agonist-antagonists. CONCLUSION: Our analysis found several interventions to be effective in reducing the incidence of pruritus. Although sub-hypnotic doses of propofol appear to have an antipruritic effect, replication of this finding and further investigation of optimal dosing are warranted. SYSTEMATIC REVIEW PROTOCOL: PROSPERO (CRD42022367058).


Asunto(s)
Morfina , Propofol , Embarazo , Adulto , Humanos , Femenino , Analgésicos Opioides , Propofol/efectos adversos , Metaanálisis en Red , Teorema de Bayes , Cesárea/efectos adversos , Prurito/prevención & control , Prurito/inducido químicamente
16.
Am J Obstet Gynecol MFM ; 5(9): 101076, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37402438

RESUMEN

OBJECTIVE: This study aimed to conduct a systematic review and to evaluate the psychometric measurement properties of instruments for postpartum anxiety using the Consensus-Based Standards for the Selection of Health Measurement Instruments guidelines to identify the best available patient-reported outcome measure. DATA SOURCES: We searched 4 databases (CINAHL, Embase, PubMed, and Web of Science in July 2022) and included studies that evaluated at least 1 psychometric measurement property of a patient-reported outcome measurement instrument. The protocol was registered with the International Prospective Register for Systematic Reviews under identifier CRD42021260004 and followed the Consensus-Based Standards for the Selection of Health Measurement Instruments guidelines for systematic reviews. STUDY ELIGIBILITY: Studies eligible for inclusion were those that assessed the performance of a patient-reported outcome measure for screening for postpartum anxiety. We included studies in which the instruments were subjected to some form of psychometric property assessment in the postpartum maternal population, consisted of at least 2 questions, and were not subscales. METHODS: This systematic review used the Consensus-Based Standards for the Selection of Health Measurement Instruments and the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines to identify the best patient-reported outcome measurement instrument for examining postpartum anxiety. A risk of bias assessment was performed, and a modified GRADE approach was used to assess the level of evidence with recommendations being made for the overall quality of each instrument. RESULTS: A total of 28 studies evaluating 13 instruments in 10,570 patients were included. Content validity was sufficient in 9 with 5 instruments receiving a class A recommendation (recommended for use). The Postpartum Specific Anxiety Scale, Postpartum Specific Anxiety Scale Research Short Form, Postpartum Specific Anxiety Scale Research Short Form Covid, Postpartum Specific Anxiety Scale-Persian, and the State-Trait Anxiety Inventory demonstrated adequate content validity and sufficient internal consistency. Nine instruments received a recommendation of class B (further research required). No instrument received a class C recommendation (not recommended for use). CONCLUSION: Five instruments received a class A recommendation, all with limitations, such as not being specific to the postpartum population, not assessing all domains, lacking generalizability, or evaluation of cross-cultural validity. There is currently no freely available instrument that assess all domains of postpartum anxiety. Future studies are needed to determine the optimum current instrument or to develop and validate a more specific measure for maternal postpartum anxiety.


Asunto(s)
COVID-19 , Humanos , Ansiedad/diagnóstico , Ansiedad/epidemiología , Ansiedad/etiología , Medición de Resultados Informados por el Paciente , Psicometría
17.
AJOG Glob Rep ; 3(3): 100226, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37334251

RESUMEN

BACKGROUND: Inpatient postpartum recovery trajectories following cesarean delivery and spontaneous vaginal delivery are underexplored. OBJECTIVE: This study primarily aimed to compare recovery following cesarean delivery and spontaneous vaginal delivery in the first postpartum week, and secondarily to evaluate psychometrically the Japanese version of the Obstetric Quality of Recovery-10 scoring tool. STUDY DESIGN: Following institutional review board approval, the EQ-5D-3L (EuroQoL 5-Dimension 3-Level) questionnaire and a Japanese version of the Obstetric Quality of Recovery-10 measure were used to evaluate inpatient postpartum recovery in uncomplicated nulliparous parturients delivering via scheduled cesarean delivery or spontaneous vaginal delivery. RESULTS: A total of 48 and 50 women who delivered via cesarean delivery and spontaneous vaginal delivery, respectively, were recruited. Women delivering via scheduled cesarean delivery experienced significantly worse quality of recovery on days 1 and 2 compared with those who had spontaneous vaginal delivery. Quality of recovery significantly improved daily, plateauing at days 4 and 3 for cesarean delivery and spontaneous vaginal delivery groups, respectively. Compared with cesarean delivery, spontaneous vaginal delivery was associated with prolonged time to analgesia requirement, decreased opioid consumption, reduced antiemetic requirement, and reduced times to liquid/solid intake, ambulation, and discharge. Obstetric Quality of Recovery-10-Japanese is a valid (correlates with the EQ-5D-3L including a global health visual analog scale, gestational age, blood loss, opioid consumption, time until first analgesic request, liquid/solid intake, ambulation, catheter removal, and discharge), reliable (Cronbach alpha=0.88; Spearman-Brown reliability estimate=0.94; and intraclass correlation coefficient=0.89), and clinically feasible (98% 24-hour response rate) measure. CONCLUSION: Inpatient postpartum recovery is significantly better in the first 2 postpartum days following spontaneous vaginal delivery compared with scheduled cesarean delivery. Inpatient recovery is largely achieved within 4 and 3 days following scheduled cesarean delivery and spontaneous vaginal delivery, respectively. Obstetric Quality of Recovery-10-Japanese is a valid, reliable, and feasible measure of inpatient postpartum recovery.

18.
Korean J Anesthesiol ; 76(6): 597-616, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37066603

RESUMEN

BACKGROUND: Cesarean section is associated with moderate to severe pain and nonsteroidal anti-inflammatory drugs (NSAIDs) are commonly employed. The optimal NSAID, however, has not been elucidated. In this network meta-analysis and systematic review, we compared the influence of control and individual NSAIDs on the indices of analgesia, side effects, and quality of recovery. METHODS: CDSR, CINAHL, CRCT, Embase, LILACS, PubMed, and Web of Science were searched for randomized controlled trials comparing a specific NSAID to either control or another NSAID in elective or emergency cesarean section under general or neuraxial anesthesia. Network plots and league tables were constructed, and the quality of evidence was evaluated with Grading of Recommendations Assessment, Development and Evaluation (GRADE) analysis. RESULTS: We included 47 trials. Cumulative intravenous morphine equivalent consumption at 24 h, the primary outcome, was examined in 1,228 patients and 18 trials, and control was found to be inferior to diclofenac, indomethacin, ketorolac, and tenoxicam (very low quality evidence owing to serious limitations, imprecision, and publication bias). Indomethacin was superior to celecoxib for pain score at rest at 8-12 h and celecoxib + parecoxib, diclofenac, and ketorolac for pain score on movement at 48 h. In regard to the need for and time to rescue analgesia COX-2 inhibitors such as celecoxib were inferior to other NSAIDs. CONCLUSIONS: Our review suggests the presence of minimal differences among the NSAIDs studied. Nonselective NSAIDs may be more effective than selective NSAIDs, and some NSAIDs such as indomethacin might be preferable to other NSAIDs.


Asunto(s)
Diclofenaco , Ketorolaco , Humanos , Embarazo , Femenino , Diclofenaco/uso terapéutico , Ketorolaco/uso terapéutico , Celecoxib/uso terapéutico , Cesárea/efectos adversos , Metaanálisis en Red , Antiinflamatorios no Esteroideos/efectos adversos , Indometacina/uso terapéutico , Dolor/tratamiento farmacológico
20.
Am J Obstet Gynecol ; 228(5S): S1283-S1304.e1, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36925412

RESUMEN

Epidural-related maternal fever affects 15% to 25% of patients who receive a labor epidural. Two meta-analyses demonstrated that epidural-related maternal fever is a clinical phenomenon, which is unlikely to be caused by selection bias. All commonly used neuraxial techniques, local anesthetics with or without opioids, and maintenance regimens are associated with epidural-related maternal fever, however, the impact of each component is unknown. Two major theories surrounding epidural-related maternal fever development have been proposed. First, labor epidural analgesia may lead to the development of hyperthermia through a sterile (noninfectious) inflammatory process. This process may involve reduced activation of caspase-1 (a protease involved in cell apoptosis and activation of proinflammatory pathways) secondary to bupivacaine, which impairs the release of the antipyrogenic cytokine, interleukin-1-receptor antagonist, from circulating leucocytes. Detailed mechanistic processes of epidural-related maternal fever remain to be determined. Second, thermoregulatory mechanisms secondary to neuraxial blockade have been proposed, which may also contribute to epidural-related maternal fever development. Currently, there is no prophylactic strategy that can safely prevent epidural-related maternal fever from occurring nor can it easily be distinguished clinically from other causes of intrapartum fever, such as chorioamnionitis. Because intrapartum fever (of any etiology) is associated with adverse outcomes for both the mother and baby, it is important that all parturients who develop intrapartum fever are investigated and treated appropriately, irrespective of labor epidural utilization. Institution of treatment with appropriate antimicrobial therapy is recommended if an infectious cause of fever is suspected. There is currently insufficient evidence to warrant a change in recommendations regarding provision of labor epidural analgesia and the benefits of good quality labor analgesia must continue to be reiterated to expectant mothers.


Asunto(s)
Analgesia Epidural , Trabajo de Parto , Complicaciones del Trabajo de Parto , Embarazo , Femenino , Humanos , Incidencia , Complicaciones del Trabajo de Parto/epidemiología , Complicaciones del Trabajo de Parto/etiología , Fiebre/etiología , Fiebre/epidemiología , Analgesia Epidural/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA