J Colloid Interface Sci ; 671: 336-343, 2024 May 22.
Article En | MEDLINE | ID: mdl-38815370

Against the backdrop of advancements in modern multifunctional wearable electronics, there is a growing demand for simple, sustainable, and portable electronic skin (e-skin), posing significant challenges. This study aims to delineate the development of a straightforward, transparent, highly sensitive, and high power-density electronic skin based on a triboelectric nanogenerator(S-TENG), designed for harvesting human body energy and real-time monitoring of the physiological motion status. Our e-skin incorporates thermally treated polyvinylidene fluoride (PVDF) fiber membranes as the contact layer and a film of silver nanowires as the conductive electrodes. The resulting contact-separation type e-skin exhibits an impressive transparency of 80 %, along with a nice sensitivity value, capable of detecting a light touch from a 0.13 g sponge and demonstrating good working stability and breathability. Leveraging the triboelectric effect, our e-skin generates an open-circuit voltage of 301 V and a short-circuit current of 2.7 µA under an extrinsic force of 8 N over an interaction area of 4 × 4 cm2, achieving a power density up to 306 mW/m2. With its signal processing circuitry, the integrated S-TENG showcases nice energy harvesting and signal transmission capabilities. Accordingly, we contend that S-TENG has potential applications in energy capture and real-time human motion state monitoring. This research is anticipated to blaze a novel and practical trail for self-powered wearable devices and personalized health rehabilitation training regimens.

2.
Molecules ; 29(9)2024 Apr 23.
Article En | MEDLINE | ID: mdl-38731417

In recent years, renewable and sustainable triboelectric nanogenerators have attracted attention due to their high energy conversion rate, and enhancing their functionality further contributes to their applicability across various fields. A pH-sensitive triboelectric nanogenerator (pH-TENG) has been prepared by electrostatic spinning technology, with anthocyanin as the pH indicator and environmentally friendly polyvinyl alcohol (PVA) as the substrate. Among many friction-negative materials, the pH-TENG exhibits the best combination with fluorinated ethylene propylene (FEP) and yields an open-circuit voltage of 62 V, a short-circuit current of 370 nA, and a transferred charge of 21.8 nC. At a frequency of 3 Hz, it can charge a 4.7 µF capacitor to 2 V within 45 s, effectively powering a thermometer. Furthermore, the presence of anthocyanin does not affect the pH-TENG's power generation performance and enables the monitoring of a wide range of environmental pH changes, with an ΔE change of 28.8 ± 7.6. Therefore, pH-TENG prepared with environmentally friendly materials can bring new available materials to the biological and medical fields.

3.
Sci Adv ; 9(20): eadg5152, 2023 05 19.
Article En | MEDLINE | ID: mdl-37196075

Mild concussions occur frequently and may come with long-term cognitive, affective, and physical sequelae. However, the diagnosis of mild concussions lacks objective assessment and portable monitoring techniques. Here, we propose a multiangle self-powered sensor array for real-time monitoring of head impact to further assist in clinical analysis and prevention of mild concussions. The array uses triboelectric nanogenerator technology, which converts impact force from multiple directions into electrical signals. With an average sensitivity of 0.214 volts per kilopascal, a response time of 30 milliseconds, and a minimum resolution of 1.415 kilopascals, the sensors exhibit excellent sensing capability over a range of 0 to 200 kilopascals. Furthermore, the array enables reconstructed head impact mapping and injury grade assessment via a prewarning system. By gathering standardized data, we expect to build a big data platform that will permit in-depth research of the direct and indirect effects between head impacts and mild concussions in the future.


Brain Concussion , Humans , Brain Concussion/diagnosis , Electric Power Supplies , Forecasting , Electricity
4.
Int J Biol Macromol ; 215: 123-131, 2022 Aug 31.
Article En | MEDLINE | ID: mdl-35691434

Since bacterial contamination is a significant threat to humans, early detection is essential to safeguard dietary safety and physical health. Here, a nanofiber color indicator film based on poly-l-lactic acid (PLLA) as the support and anthocyanin as the indicator material was prepared by electrostatic spinning. It was found that the PLLA/0.8CY nanofiber color indicator film was hydrophobic (the water contact angle of 102.4°) and contained uniform nanofibers with an average diameter of 750 nm. In addition, the film's humidity insensitivity, reusability, color stability, and ammonia sensitivity (the limits of detection 35.39 ppm) made the film environmentally friendly and more accurate and faster for bacterial detection. The film was able to sense 102 CFU/mL of gram-positive and negative bacteria after the model strain E. coli and L. monocytogene. Thus, the PLLA/0.8CY nanofiber color indicator film was able to perform headspace nondestructive detection of low-level bacterial contamination.


Nanofibers , Humans , Anthocyanins , Escherichia coli , Nanofibers/chemistry , Polyesters/chemistry
5.
Int J Biol Macromol ; 208: 1019-1028, 2022 May 31.
Article En | MEDLINE | ID: mdl-35381289

Nanocomposite hydrogel composed of Poly N-isopropylacrylamide (PNIPAM), poly N-tert-Butylacrylamide (PBAM) and poly acrylic acid (PAA) was synthesized by free radical polymerization, and then thymol was embedded in it, to design an active antibacterial material that could control release. The characterization of products used SEM, AFM, FTIR, Zeta sizer to analyze the sensitivity of nanoparticles to pH, temperature and salt ions, and the agar diffusion method was used to determine the antibacterial effect of the polymers. The results showed that nanoparticles had pH, temperature and salt ion responsiveness, PNIPAM/PBAM (65:35) nanoparticles loaded thymol had longer release time (more than 24 h) at lower temperature than that (around 6 h) at high temperature. In addition, the nanoparticles could also be adsorbed on the chitosan film, which makes it have a wider range of applications. All thymol-loaded nanoparticles showed antibacterial activity against both B. subtilis and E. coli, while the chitosan film adsorbed nanoparticles showed weak effect, which was related to the controlled and slow release of bacteriostatic agents. Thus, these copolymers have potential value in the development and application of bacteriostatic packaging films for food.