1.
Front Physiol ; 13: 869701, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35694404

RESUMEN

Introduction: The blood flow in the normal cardiovascular system is predominately laminar but operates close to the threshold to turbulence. Morphological distortions such as vascular and valvular stenosis can cause transition into turbulent blood flow, which in turn may cause damage to tissues in the cardiovascular system. A growing number of studies have used magnetic resonance imaging (MRI) to estimate the extent and degree of turbulent flow in different cardiovascular diseases. However, the way in which heart rate and inotropy affect turbulent flow has not been investigated. In this study we hypothesized that dobutamine stress would result in higher turbulence intensity in the healthy thoracic aorta. Method: 4D flow MRI data were acquired in twelve healthy subjects at rest and with dobutamine, which was infused until the heart rate increased by 60% when compared to rest. A semi-automatic segmentation method was used to segment the thoracic aorta in the 4D flow MR images. Subsequently, flow velocity and several turbulent kinetic energy (TKE) parameters were calculated in the ascending aorta, aortic arch, descending aorta and whole thoracic aorta. Results: With dobutamine infusion there was an increase in heart rate (66 ± 9 vs. 108 ± 13 bpm, p < 0.001) and stroke volume (88 ± 13 vs. 102 ± 25 ml, p < 0.01). Additionally, there was an increase in Peak Average velocity (0.7 ± 0.1 vs. 1.2 ± 0.2 m/s, p < 0.001, Peak Max velocity (1.3 ± 0.1 vs. 2.0 ± 0.2 m/s, p < 0.001), Peak Total TKE (2.9 ± 0.7 vs. 8.0 ± 2.2 mJ, p < 0.001), Peak Median TKE (36 ± 7 vs. 93 ± 24 J/m3, p = 0.002) and Peak Max TKE (176 ± 33 vs. 334 ± 69 J/m3, p < 0.001). The relation between cardiac output and Peak Total TKE in the whole thoracic aorta was very strong (R2 = 0.90, p < 0.001). Conclusion: TKE of blood flow in the healthy thoracic aorta increases with dobutamine stress and is strongly related to cardiac output. Quantification of such turbulence intensity parameters with cardiac stress may serve as a risk assessment of aortic disease development.

2.
J Magn Reson Imaging ; 56(5): 1393-1403, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35128754

RESUMEN

BACKGROUND: Epicardial adipose tissue (EAT) may induce left atrium (LA) wall inflammation and promote LA fibrosis. Therefore, simultaneous assessment of these two important atrial fibrillation (AF) risk factors would be desirable. PURPOSE: To perform a comprehensive evaluation of 3D Dixon water-fat separated late gadolinium enhancement (LGE-Dixon) MRI by analysis of repeatability and systematic comparison with reference methods for assessment of fibrosis and fat. STUDY TYPE: Prospective. POPULATION: Twenty-eight, 10, and 7 patients, respectively, with clinical indications for cardiac MRI. FIELD STRENGTH/SEQUENCE: A 1.5-T scanner, inversion recovery multiecho spoiled gradient echo. ASSESSMENT: Twenty-eight patients (age 58 ± 19 years, 15 males) were scanned using LGE-Dixon. A 5-point Likert-type scale was used to grade the image quality. Another 10 patients (age 46 ± 19 years, 9 males) were scanned using LGE-Dixon and 3D proton density Dixon (PD-Dixon). Finally, seven patients (age 62 ± 14 years, 4 males) were scanned using LGE-Dixon and conventional LGE. The scan time, intraobserver and interobserver variability, and levels of agreement were assessed. STATISTICAL TESTS: Student's t-test, one-way ANOVA, and Mann-Whitney U-test were used; P < 0.05 was considered significant, intraclass correlation coefficient (ICC). RESULTS: The scan time (minutes:seconds) for LGE-Dixon (n = 28) was 5:01 ± 1:40. ICC values for intraobserver and interobserver measurements of LA wall fibrosis percentage were 0.98 (95% CI, 0.97-0.99) and 0.97 (95% CI, 0.94-0.99) while of EAT were 0.92 (95% CI, 0.82-0.97) and 0.90 (95% CI, 0.80-0.95). The agreement for LA fibrosis percentage between the LGE-Dixon and the conventional LGE was 0.92 (95% CI, 0.66-0.99) and for EAT volume between the LGE-Dixon and the PD-Dixon was 0.93 (95% CI, 0.72-0.98). CONCLUSION: LA fibrosis and EAT can be assessed simultaneously using LGE-Dixon. This method allows a high level of intraobserver and interobserver repeatability as well as agreement with reference methods and can be performed in a clinically feasible scan time. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 3.


Asunto(s)
Fibrilación Atrial , Gadolinio , Tejido Adiposo/diagnóstico por imagen , Adulto , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/patología , Medios de Contraste , Fibrosis , Atrios Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Protones , Agua
3.
Front Cardiovasc Med ; 7: 581495, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33324686

RESUMEN

Introduction: The effects of heart rate, inotropy, and lusitropy on multidimensional flow patterns and energetics within the human heart remain undefined. Recently, reduced volume and end-diastolic kinetic energy (KE) of the portion of left ventricular (LV) inflow passing directly to outflow, Direct flow (DF), have been shown to reflect inefficient LV pumping and to be a marker of LV dysfunction in heart failure patients. In this study, we hypothesized that increasing heart rate, inotropy, and lusitropy would result in an increased efficiency of intraventricular blood flow transit. Therefore, we sought to investigate LV 4D blood flow patterns and energetics with dobutamine infusion. Methods: 4D flow and morphological cardiovascular magnetic resonance (CMR) data were acquired in twelve healthy subjects: at rest and with dobutamine infusion to achieve a target heart rate ~60% higher than the resting heart rate. A previously validated method was used for flow analysis: pathlines were emitted from the end-diastolic (ED) LV blood volume and traced forward and backward in time to separate four functional LV flow components. For each flow component, KE/mL blood volume at ED was calculated. Results: With dobutamine infusion there was an increase in heart rate (64%, p < 0.001), systolic blood pressure (p = 0.02) and stroke volume (p = 0.01). Of the 4D flow parameters, the most efficient flow component (DF), increased its proportion of EDV (p < 0.001). The EDV proportion of Residual volume, the blood residing in the ventricle over at least two cardiac cycles, decreased (p < 0.001). The KE/mL at ED for all flow components increased (p < 0.001). DF had the largest absolute and relative increase while Residual volume had the smallest absolute and relative increase. Conclusions: This study demonstrates that it is feasible to compare 4D flow patterns within the normal human heart at rest and with stress. At higher heart rate, inotropy and lusitropy, elicited by dobutamine infusion, the efficiency of intraventricular blood flow transit improves, as quantified by an increased relative volume and pre-systolic KE of the most efficient DF component of the LV volume. The change in these markers may allow a novel assessment of LV function and LV dysfunction over a range of stress.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...