Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Arch Oral Biol ; 80: 18-26, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28364672

RESUMEN

OBJECTIVE: The present in situ - investigation aimed to specify the impact of pure hydroxyapatite microclusters on initial bioadhesion and bacterial colonization at the tooth surface. DESIGN: Pellicle formation was carried out in situ on bovine enamel slabs (9 subjects). After 1min of pellicle formation rinses with 8ml of hydroxyapatite (HA) microclusters (5%) in bidestilled water or chlorhexidine 0.2% were performed. As negative control no rinse was adopted. In situ biofilm formation was promoted by the intraoral slab exposure for 8h overnight. Afterwards initial bacterial adhesion was quantified by DAPI staining and bacterial viability was determined in vivo/in vitro by live/dead-staining (BacLight). SEM analysis evaluated the efficacy of the mouthrinse to accumulate hydroxyapatite microclusters at the specimens' surface and spit-out samples of the testsolution were investigated by TEM. RESULTS: Compared to the control (2.36×106±2.01×106bacteria/cm2), significantly reduced amounts of adherent bacteria were detected on specimens rinsed with chlorhexidine 0.2% (8.73×104±1.37×105bacteria/cm2) and likewise after rinses with the hydroxyapatite testsolution (2.08×105±2.85×105bacteria/cm2, p<0.001). No demonstrable effect of HA-particles on Streptococcus mutans viability could be shown. SEM analysis confirmed the temporary adsorption of hydroxyapatite microclusters at the tooth surface. Adhesive interactions of HA-particles with oral bacteria were shown by TEM. CONCLUSION: Hydroxyapatite microclusters reduced initial bacterial adhesion to enamel in situ considerably and could therefore sensibly supplement current approaches in dental prophylaxis.


Asunto(s)
Adhesión Bacteriana/efectos de los fármacos , Biopelículas/efectos de los fármacos , Esmalte Dental/efectos de los fármacos , Durapatita/farmacología , Antisépticos Bucales/farmacología , Adulto , Animales , Bovinos , Clorhexidina/farmacología , Esmalte Dental/microbiología , Película Dental/microbiología , Humanos , Viabilidad Microbiana/efectos de los fármacos , Microscopía Electrónica , Microscopía Fluorescente , Persona de Mediana Edad , Saliva/microbiología , Streptococcus mutans/efectos de los fármacos
2.
Minerva Med ; 104(6): 625-30, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24316915

RESUMEN

AIM: The importance of the abdominal musculature in spine stability, has promoted the development of a variety of studies. Ultrasound imaging (UI) is a valuable tool which, when applied appropriately, has the potential to provide significant insight into abdominal muscle contraction. Limited studies have been taken place regarding the relationship between ultrasound measures of muscle thickening and electromyography (EMG) measures of activation. Inconsistent results, however, have been reported. Based on previous studies association between abdominal muscle activation and thickening may be affected by contraction level. The aims of this study were to measure the relationship between abdominal muscle thickness and abdominal muscles amplitude in different levels of abdominal muscles contraction. METHODS: The research was carried on with a convenience sampling at the Physical Therapy Department of University of Social Welfare and Rehabilitation Sciences. Thirty healthy participants volunteered for this study. Muscle thickness right transversus abdominis (TrA) and obliqus internus (OI) muscles in abdominal hallowing maneuvers with and without pelvic floor muscle (PFM) contraction has been measured. Additionally, surface EMG of the right TrA/IO muscles was recorded. A hardware electrical part that acts as trigger system was used to record the activities of abdominal muscles in UI and EMG synchronously. Thickness change, normalized thickness and maximum amplitude abdominal muscles were used for statistical analysis. RESULTS: Correlations between the thickness change and amplitude measures were -0.03 -- 0.38 for TrA/IO. The Correlations between the normalized thickness and amplitude measures were -0.04--0.26 for TrA/IO. CONCLUSION: There is not clear relationship between increases in abdominal muscle activation and corresponding measures of thickening during abdominal muscle contraction. Changes in thickness of deep abdominal muscle cannot be used to indicate changes in the electrical activity in this muscle.


Asunto(s)
Músculos Abdominales/diagnóstico por imagen , Músculos Abdominales/fisiología , Electromiografía/métodos , Contracción Muscular/fisiología , Músculos Abdominales/anatomía & histología , Adolescente , Adulto , Femenino , Humanos , Masculino , Diafragma Pélvico/diagnóstico por imagen , Diafragma Pélvico/fisiología , Ultrasonografía , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA