Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 5 de 5
1.
Arch Cardiovasc Dis ; 112(5): 323-333, 2019 May.
Article En | MEDLINE | ID: mdl-30797733

BACKGROUND: Transcatheter pulmonary valvuloplasty in neonates with pulmonary atresia and intact ventricular septum (PA-IVS) or duct-dependent pulmonary valve stenosis (DD-PVS) has become a reasonable alternative to surgical right ventricle decompression. AIM: To investigate mid-term outcomes following pulmonary valvuloplasty. METHODS: Sixty-five neonates with PA-IVS (n=29) or DD-PVS (n=36) (median age 4 days; mean weight 3.0kg) undergoing pulmonary valvuloplasty were reviewed retrospectively. Procedural data and clinical outcomes were assessed. RESULTS: Pulmonary valvuloplasty was successful in 59 patients (90.8%). Preterm birth, larger tricuspid valve annulus diameter and PA-IVS correlated with procedural failure. Eleven patients (18.6%) required a Blalock-Taussig shunt during early follow-up, despite valvuloplasty. These neonates had smaller tricuspid and pulmonary valve annulus Z-scores (-1.9 vs. -0.8 [p=0.04] and -2.5 vs. -0.9 [P=0.005], respectively) and a higher incidence of "bipartite" right ventricle (P=0.02). Mean follow-up was 5.4±3.3 years. Mortality after successful valvuloplasty was 8.5% (n=5). Among the 54 survivors, biventricular repair was achieved in 52 patients (96.3%), including nine with a previous Blalock-Taussig shunt. The cumulative rate of subsequent surgery (excluding Blalock-Taussig shunt) was 13.7% (95% confidence interval 6.8-26.7%) and 16.4% (95% confidence interval 8.5-30.4%) at 2 and 4 years, respectively. Secondary surgery was significantly more frequent in PA-IVS compared with DD-PVS, and in neonates with a Blalock-Taussig shunt (P=0.003 and 0.01, respectively). CONCLUSIONS: Selected neonates with DD-PVS or PA-IVS managed by transcatheter pulmonary valvuloplasty had a good mid-term outcome. In neonates with a borderline small right ventricle, a hybrid strategy with a supplementary source of pulmonary blood flow can be efficient to achieve biventricular repair.


Balloon Valvuloplasty/methods , Cardiac Catheterization/methods , Heart Defects, Congenital/therapy , Pulmonary Atresia/therapy , Pulmonary Valve/abnormalities , Age Factors , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/mortality , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Databases, Factual , Female , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/mortality , Heart Defects, Congenital/physiopathology , Hemodynamics , Humans , Infant, Newborn , Male , Pulmonary Atresia/diagnostic imaging , Pulmonary Atresia/mortality , Pulmonary Atresia/physiopathology , Pulmonary Circulation , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Recovery of Function , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
3.
JACC Cardiovasc Interv ; 11(19): 1909-1916, 2018 10 08.
Article En | MEDLINE | ID: mdl-30219326

OBJECTIVES: The aim of this study was to describe and analyze data from patients treated in France with the Edwards SAPIEN transcatheter heart valve (Edwards Lifesciences LLC, Irvine, California) in the pulmonary position. BACKGROUND: The Edwards SAPIEN valve has recently been introduced for percutaneous pulmonary valve implantation (PPVI). METHODS: From April 2011 to May 2017, 71 patients undergoing PPVI were consecutively included. RESULTS: The median age at PPVI was 26.8 years (range 12.8 to 70.1 years). Primary underlying diagnoses were conotruncal malformations (common arterial trunk, tetralogy of Fallot and variants; n = 45), Ross procedure (n = 18), and other diagnoses (n = 8). PPVI indication was pure stenosis in 33.8% of patients, pure regurgitation in 28.1%, and mixed lesions in 38.1%. PPVI was successfully implemented in 68 patients (95.8%). Pre-stenting of the right ventricular outflow tract was performed in 70 patients (98.6%). Early major complications occurred in 4 subjects (5.6%), including 1 death, 1 coronary compression, and 2 pulmonary valve embolizations. Three of the 4 major complications occurred in the first 15 operated patients. No significant regurgitation was recorded after the procedure. Transpulmonary gradient was significantly reduced from 34.5 to 10.5 mm Hg (p < 0.0001). No patient died during a 1-month follow-up period. At 1-year follow-up, the death rate was 2.9%, and 3 patients had undergone surgical reintervention (44%). CONCLUSIONS: Early results with the Edwards SAPIEN valve in the pulmonary position demonstrate an ongoing high rate of procedural success.


Cardiac Catheterization/instrumentation , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Stenosis/surgery , Pulmonary Valve/surgery , Adolescent , Adult , Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Child , Female , France , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Postoperative Complications/mortality , Prospective Studies , Prosthesis Design , Pulmonary Valve/abnormalities , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/mortality , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Stenosis/diagnostic imaging , Pulmonary Valve Stenosis/mortality , Pulmonary Valve Stenosis/physiopathology , Recovery of Function , Registries , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Young Adult
4.
Ann Pediatr Cardiol ; 11(2): 191-193, 2018.
Article En | MEDLINE | ID: mdl-29922017

We report a rare and serious complication of cardiac strangulation arising from the implantation of epicardial pacing leads in a newborn. Patient's follow-up 9-month postsurgery revealed compression under the pulmonary valve annulus by a pacemaker lead, causing progressive stenosis of the right ventricular outflow tract. The epicardial leads were replaced to relieve compression, and stenosis of the right ventricular outflow tract was rectified. Pacemaker implantation in newborns is not without challenges; epicardial leads should be carefully positioned to avoid any compression of cardiac structures.

5.
J Pediatr Endocrinol Metab ; 30(8): 863-868, 2017 Aug 28.
Article En | MEDLINE | ID: mdl-28753541

BACKGROUND: The aim of the study was to assess health-related quality of life (HR-QoL) in children with Turner syndrome in comparison with controls. METHODS: We prospectively recruited 16 female girls with Turner syndrome (mean age 15.2±2.6 years) and 78 female controls (mean age 12.7±2.8 years) in randomly selected schools. We used the PedsQL, a generic HR-QoL questionnaire (self and parents' versions). RESULTS: Global HR-QoL scores in Turner syndrome were lower than controls for self-reports (respectively, 74.3±3.0 vs. 82.8±1.3, p=0.01) and parents' reports (62.7±3.8 vs. 80.1±1.7, p<0.0001). In Turner syndrome, self-reported HR-QoL was impaired in school functioning (70.6±4.0 vs. 80.71±1.7, p=0.02), social functioning (78.2±4.0 vs. 90.4±1.8, p<0.01) and physical functioning (78.5±3.2 vs. 87.1±1.4, p=0.02), but not in emotional functioning. Parents' reported HR-QoL was impaired in all four dimensions. CONCLUSIONS: HR-QoL was impaired in this cohort of young females with Turner syndrome, as in previously reported adult studies. In addition to medical treatment and routine clinical follow-up, female girls and teenagers with Turner syndrome should also be supported psychologically by social, educational and psychotherapeutic interventions that aim to address their self-esteem and emotional difficulties.


Health Status , Quality of Life/psychology , Self Concept , Social Adjustment , Turner Syndrome/psychology , Adolescent , Child , Cross-Sectional Studies , Female , Humans , Parents/psychology , Self Report , Surveys and Questionnaires
...