Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Ophthalmol ; 17: 2251-2266, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37575208

RESUMEN

Purpose: To explore and report on how glaucoma care was impacted by the SARS-CoV-2 pandemic (COVID-19) in New York City (NYC) with a specific emphasis on the role of telemedicine. Patients and Methods: This was a qualitative, cross-sectional study that engaged glaucoma clinicians in semi-structured interviews to elicit perspectives on telemedicine and patient care experiences during the pandemic. Interview responses were coded and analyzed thematically. Results: Twenty clinicians participated. Mean participant age was 48.8 ± 12.3 years, and the mean number of years in practice post-glaucoma fellowship was 17.5 ± 12.4 years. Four main themes pertinent to the role of telemedicine triggered by the COVID-19 pandemic were identified: (1) The Need to Ensure Patient and Staff Safety Drove Telemedicine Uptake; (2) Telemedicine Allowed Providers to Address Subjective Complaints; (3) Telemedicine was Discontinued Due To Concerns of Compromised Patient Safety and Measurement Inaccuracy; (4) Technological Advances are Needed for Continued Telemedicine Usage and Uptake in Glaucoma Care. The interviews suggested that telemedicine usage dropped markedly within just a few months during the pandemic, and for most physicians interviewed, telemedicine is no longer part of their clinical practice. Several clinicians reported optimism towards future implementation of telemedicine as the technology develops. Conclusion: This study identified 4 themes outlining the uptake, application, discontinuation and overall perspectives on telemedicine by glaucoma clinicians. The role of telemedicine, as triggered by the COVID-19 pandemic, may have lasting implications for patient safety, continuity of care, and glaucoma care delivery beyond this public health crisis.

2.
Clin Ophthalmol ; 17: 145-154, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36647517

RESUMEN

Purpose: To compare the safety and efficacy of Kahook Dual Blade (KDB) versus Trabectome with cataract surgery in reducing intraocular pressure (IOP) and medications used by patients with glaucoma. Methods: Retrospective chart review comparing eyes after KDB or Trabectome with cataract surgery at 2 academic centers. Surgical success was defined as IOP <21 mmHg with ≥20% IOP reduction at post-operative month 12 (POM12). Changes in IOP, number of glaucoma medications, and adverse events were assessed. Results: Ninety eyes in the KDB group and 125 eyes in the Trabectome group were included. Mean changes in IOP at POM12 were -1.9 ± 4.9 mmHg (11.2%, P = 0.002) in the KDB group and -3.5 ± 5.5 mmHg (19.1%, P < 0.001) in the Trabectome group, without a significant difference between the groups (P = 0.20). Mean change in glaucoma medications at POM12 was -0.8 ± 1.5 in the KDB group (58%, P < 0.001) and -0.3 ± 1.3 (38%, P = 0.003) in the Trabectome group, with KDB having a greater decrease in medications (P = 0.02). The percentage of eyes achieving success was 30% for the KDB group and 54% for the Trabectome group (P = 0.01). Hyphema was the most common complication, with an incidence of 3% for the KDB group and 14% for the Trabectome group (P = 0.01). Conclusion: KDB or Trabectome with cataract surgery is safe and effective at lowering IOP and medication burden, with KDB resulting in a greater reduction in medications and Trabectome more frequently achieving success with an increased incidence of hyphema. Considering the study's limitations, the outcomes were similar.

3.
Asia Pac J Ophthalmol (Phila) ; 7(5): 352-355, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29638049

RESUMEN

Visual evoked potentials (VEP) can be used to assess the function of the visual system objectively. Research on VEP testing as a method of glaucoma evaluation has been performed for many years. Pattern VEP has shown good specificity and sensitivity in the detection of glaucoma in some studies, but other studies have not shown similar efficacy. Multifocal VEP can produce a topographical measure of glaucomatous damage and has been shown to be able to detect a similar number of defects in patients with glaucoma or ocular hypertension as compared with the visual field test. Despite promising data on these VEP test modalities in the assessment of glaucoma, multiple aspects of test administration make their routine use impractical in a clinical setting. New VEP testing modalities, such as short-duration transient VEP and isolated-check VEP, allow the test to be performed more quickly and easily. Further research on these more recent technologies may allow us to use VEP effectively in the diagnosis and management of glaucoma.


Asunto(s)
Técnicas de Diagnóstico Oftalmológico , Potenciales Evocados Visuales , Glaucoma/diagnóstico , Potenciales Evocados Visuales/fisiología , Glaucoma/fisiopatología , Humanos , Sensibilidad y Especificidad
4.
J Glaucoma ; 24(4): 311-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25826644

RESUMEN

PURPOSE: To report the 6-month comparative outcomes and bleb morphology for needle revision with bevacizumab and mitomycin C (MMC) versus MMC alone of failed trabeculectomy and ExPRESS shunt blebs. METHODS: Patients undergoing bleb needle revision procedures were enrolled in this study. All patients received a subconjunctival injection of 0.1 mL MMC (0.4 mg/mL) mixed with 0.1 mL preservative-free lidocaine (1%) at the beginning of the procedure. The patients were randomized into 2 cohorts assigned to receive either 1.0 mg (0.04 mL of 25 mg/mL) subconjunctival bevacizumab (treatment group) or 0.04 mL of balanced salt solution (control group) injected in an identical manner posterior to the bleb after the bleb needling. Success was defined as ≥20% reduction in intraocular pressure (IOP) without any IOP-lowering medications. Qualified success was defined as ≥20% reduction of IOP with IOP-lowering medications. Failure was defined as IOP>21 mm Hg, IOP reduction <20%, or need for additional surgery. Bleb morphology was classified using the Indiana Bleb Appearance Grading Scale. RESULTS: Six months postoperatively, in treatment group (n=29), 57% of patients achieved complete success, and 43% failed. In control group (n=29), 41% of patients achieved complete success, 7% achieved qualified success, and 52% failed. The difference in success rates between the 2 groups was not statistically significant (P=0.35). At 6 months, the mean IOP was 11.52 in treatment group and 12.83 in control group (P=0.45); patients in treatment group were on a mean of 0.16 medications as compared with 0.58 medications in control group (P=0.058). For bleb morphology of treatment group compared with control group, the blebs had less vascularity (0.76 vs. 1.20, respectively, on a scale of 0 to 4, P<0.05) and greater extent (2.68 vs. 2.36, on a scale of 0 to 3, P=0.022) in treatment group. CONCLUSIONS: There was no significant difference between the success rates and IOPs at postoperative month 6 between treatment and control groups. Postoperative blebs in the treatment group were less vascular and had greater extent.


Asunto(s)
Alquilantes/administración & dosificación , Inhibidores de la Angiogénesis/administración & dosificación , Anticuerpos Monoclonales Humanizados/administración & dosificación , Conjuntiva/efectos de los fármacos , Glaucoma/cirugía , Mitomicina/administración & dosificación , Trabeculectomía , Adulto , Anciano , Anciano de 80 o más Años , Bevacizumab , Quimioterapia Combinada , Femenino , Glaucoma/fisiopatología , Humanos , Inyecciones , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Agujas , Estudios Prospectivos , Reoperación , Estomas Quirúrgicos , Insuficiencia del Tratamiento , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores
5.
Cornea ; 28(5): 589-93, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19421032

RESUMEN

PURPOSE: To report the identification and characterization of stromal amyloid deposits in patients with keratoconus. METHODS: The excised corneal buttons from 2 patients diagnosed clinically with keratoconus underwent histochemical analysis with Masson trichrome, Congo red, Alcian blue, and periodic acid-Schiff stains, and immunohistochemical analysis for the transforming growth factor beta-induced gene (TGFBI) protein product (TGFBIp), prealbumin, lysozyme, and kappa and lambda light chain expression. After the collection of DNA from both patients, exons 4, 11, 12, 13 and 14 of TGFBI were amplified and sequenced to search for mutations previously associated with dystrophic corneal stromal amyloid deposition. RESULTS: Light microscopic examination of the corneal buttons revealed stromal thinning, epithelial basement membrane abnormalities, and focal disruption of Bowman layer. Multiple stromal deposits were identified that stained red with Masson trichrome, pink with periodic acid-Schiff, and red with Congo red; the Congo red-stained deposits demonstrated birefringence and dichroism with crossed polarizing lenses. Immunohistochemical staining demonstrated reactivity of the stromal deposits with antibodies to TGFBIp but no reactivity with antibodies against prealbumin, lysozyme, or kappa and lambda light chains. Screening of TGFBI exons 4, 11, 12, 13, and 14 revealed 2 previously identified single nucleotide polymorphisms present in the heterozygous state in both individuals but no other coding region variants. CONCLUSIONS: Two cases of keratoconus with clinically unsuspected, presumed secondary stromal amyloid deposition are described. Although TGFBIp is identified in the stromal deposits, no previously reported amyloidogenic mutations are identified in TGFBI in either affected individual, indicating a previously undescribed mechanism of stromal amyloid deposition.


Asunto(s)
Amiloide/química , Amiloide/metabolismo , Sustancia Propia/metabolismo , Proteínas de la Matriz Extracelular/análisis , Proteínas de la Matriz Extracelular/metabolismo , Queratocono/metabolismo , Factor de Crecimiento Transformador beta/análisis , Factor de Crecimiento Transformador beta/metabolismo , Adulto , Córnea/metabolismo , Córnea/patología , Proteínas de la Matriz Extracelular/genética , Pruebas Genéticas , Heterocigoto , Humanos , Inmunohistoquímica/métodos , Queratocono/genética , Queratocono/patología , Masculino , Persona de Mediana Edad , Polimorfismo de Nucleótido Simple , Coloración y Etiquetado , Factor de Crecimiento Transformador beta/genética
7.
J Glaucoma ; 15(6): 524-8, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17106366

RESUMEN

PURPOSE: To determine and compare the central corneal thickness (CCT) and corneal diameter among groups of patients with childhood glaucomas and assess the relationship between CCT and corneal diameter in these patients. DESIGN: A multicenter observational case series using prospective and retrospective data. METHODS: Patients from the Scheie Eye Institute, Children's Hospital of Philadelphia, and Emory and Vanderbilt Medical Centers with childhood glaucomas were eligible to participate. Retrospective data on CCT and corneal diameter of these patients were collected when available; otherwise, patients were asked to return to the ophthalmology clinics for measurements. Patients with corneal edema or central corneal scarring were excluded. One hundred eighty four glaucomatous eyes from 109 patients (median age = 9.0 y; age range = 0 to 60 y) were included. RESULTS: The mean CCT (+/-SE) was 651.1+/-63.5 microm for aphakic, 528.7+/-38.5 microm for Axenfeld-Rieger, and 563.4+/-67.9 microm for 1 degrees infantile eyes. The mean corneal diameter in aphakic, Axenfeld-Rieger, and 1 degrees infantile glaucoma eyes were 11.2+/-1.0, 12.5+/-0.9, and 13.2+/-1.2 mm, respectively. There was a significant difference in CCT and in corneal diameter between aphakic and 1 degrees infantile glaucoma eyes, and between aphakic and Axenfeld-Rieger eyes (P < 0.0001). There was a negative correlation between CCT and corneal diameter in all eyes (r = -0.41, P < 0.0001). CONCLUSIONS: Patients with aphakic glaucoma are different from those with congenital glaucoma or Axenfeld-Rieger in CCT and corneal diameter. A patient with pediatric glaucoma and a larger corneal diameter was more likely to have a thinner CCT. Attention should be paid to the CCT of patients with childhood glaucomas for interpretation of intraocular pressure.


Asunto(s)
Afaquia Poscatarata/complicaciones , Córnea/patología , Glaucoma/congénito , Glaucoma/etiología , Adolescente , Adulto , Pesos y Medidas Corporales , Niño , Preescolar , Córnea/diagnóstico por imagen , Femenino , Humanos , Lactante , Recién Nacido , Presión Intraocular , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Tonometría Ocular , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...