Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Pacing Clin Electrophysiol ; 47(5): 635-641, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38552167

RESUMEN

BACKGROUND: The stretching of the lead caused by somatic growth may lead to complications (dislodgement, fracture, failure) of transvenous leads implanted in pediatric patients. Atrial loop and absorbable ligatures may prevent it. Periodical lead advancement with lead pushing from the pocket may be an option to growth-induced stretching. Our aim was to analyze retrospectively the outcome of periodical transvenous lead advancement in children with pacemaker (PM). METHODS: A procedure of lead advancement was performed in patients with a single-chamber PM implanted for isolated congenital complete atrioventricular block or sinus node dysfunction with growth-induced lead straightening/stretching. The PM pocket was opened, the lead was released from subcutaneous adherences and was gently advanced to shape again a loop/semi-loop in the atrium without dislodging the tip. Lead data (threshold, sensing, impedance) were compared before and after the procedure. Data are described as median (25th-75th centiles). RESULTS: 14 patients with 13 VVIR and 1 AAIR PM implanted at 6.8 (5.9-8.0) years of age, 23 (19-26) kg, 118 (108-124) cm, underwent 30 advancement procedures, 1.5 (1.0-2.3) per patient, during follow-up [45 (35-63) months]. Delta between procedures was: 18 (14-25) months, 11 (7-13) cm, 6 (4-9) kg; 90% of leads were successfully advanced without complications. Three unsuccessful procedures occurred with longer times [30 (14-37) months]. Electrical lead parameters did not show significant differences pre-/post-procedures. CONCLUSION: the advancement of transvenous leads in children seems safe and effective. This procedure may be another possible choice to preserve transvenous lead position and function until growth has completed.


Asunto(s)
Marcapaso Artificial , Humanos , Masculino , Femenino , Estudios Retrospectivos , Niño , Preescolar , Electrodos Implantados , Bloqueo Atrioventricular/terapia , Síndrome del Seno Enfermo/terapia
2.
Europace ; 25(4): 1482-1490, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794445

RESUMEN

AIMS: In congenitally corrected transposition of the great arteries (CCTGA) the right ventricle (RV) is systemic. Atrioventricular block (AVB) and systolic dysfunction are frequently observed. Permanent pacing of the subpulmonary left ventricle (LV) may worsen RV dysfunction. The aim of this study was to seek out if LV conduction system pacing (LVCSP) guided by three-dimensional-electroanatomic mapping systems (3D-EAMs) can preserve RV systolic function in paediatric CCTGA patients with AVB. METHODS AND RESULTS: Retrospective analysis of CCTGA patients who underwent 3D-EAM-guided LVCSP. Three-dimensional-pacing map guided lead implantation towards septal sites with narrower paced QRS. Electrocardiograms (ECGs), echocardiograms, and lead parameters (threshold, sensing, and impedance) were compared at baseline (pre-implantation) and at 1-year follow-up. Right ventricle function was evaluated by 3D ejection fraction (EF), fractional area change (FAC), RV global longitudinal strain (GLS). Data are reported as median (25th-75th centiles). Seven CCTGA patients aged 15 (9-17) years, with complete/advanced AVB (4 with prior epicardial pacing), underwent 3D-guided LVCSP (5 DDD, 2 VVIR). Baseline echocardiographic parameters were impaired in most patients. No acute/chronic complications occurred. Ventricular pacing was >90%. At 1-year follow-up QRS duration showed no significant changes compared with baseline; however, QRS duration shortened in comparison with prior epicardial pacing. Lead parameters remained acceptable despite ventricular threshold increased. Systemic RV function was preserved: FAC and GLS improved significantly, and all patients showed normal RV EF (>45%). CONCLUSION: Three-dimensional-EAM-guided LVCSP preserved RV systolic function in paediatric patients with CCTGA and AVB after short-term follow-up.


Asunto(s)
Bloqueo Atrioventricular , Transposición de los Grandes Vasos , Humanos , Niño , Transposición Congénitamente Corregida de las Grandes Arterias/complicaciones , Transposición de los Grandes Vasos/complicaciones , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/terapia , Estudios Retrospectivos , Sistema de Conducción Cardíaco , Ventrículos Cardíacos/diagnóstico por imagen , Estimulación Cardíaca Artificial/métodos
3.
Cardiol Young ; 33(5): 760-765, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35673795

RESUMEN

BACKGROUND: Permanent pacing in children with isolated congenital complete atrioventricular block may cause left ventricular dysfunction. To prevent it, alternative pacing sites have been proposed: left ventricular epicardial or selective right ventricular endocardial pacing. AIMS: To compare the functional outcome (left ventricular systolic function and synchrony) in paediatric patients with congenital complete atrioventricular block and left ventricular apical epicardial or right ventricular transvenous mid-septal pacing. METHODS: Retrospective study. Epicardial leads were implanted by standard surgical technique, transvenous leads by 3D electroanatomic mapping systems. 3D mapping acquired 3D right ventricular local pacing map and defined the narrowest paced QRS site. 3D mapping guided screw-in bipolar leads on that ventricular site. Electrocardiogram (ECG) (QRS duration) and echocardiographic data (synchrony: interventricular mechanical delay, septal to posterior wall motion delay, systolic dyssynchrony index; contractility: global longitudinal strain, ejection fraction) were recorded. Data are reported as median [interquartile ranges]. p < 0.05 was significant. RESULTS: There were 19 transvenous systems (age 8.8 [6-14] years; right ventricular mid-septum) and 17 epicardial systems (0.04 [0.001-0.6] years; left ventricular apex). Post-implantation QRS significantly widened either in endocardial or in epicardial patients. Most patients reached 4-year follow-up. One-year and 4-year ejection fraction and global longitudinal strain were mostly within normal limits and did not show significant differences between the two groups and between the same endocardial/epicardial group. Synchrony parameters were within normal limits in the two groups. CONCLUSIONS: Left ventricular apical epicardial pacing and 3D mapping-guided right ventricular mid-septal pacing preserved left ventricular contractility and synchrony in children and adolescents with congenital complete atrioventricular block at short-/mid-term follow-up, without relevant significant differences between the two groups.


Asunto(s)
Bloqueo Atrioventricular , Estimulación Cardíaca Artificial , Adolescente , Humanos , Niño , Bloqueo Atrioventricular/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Función Ventricular Izquierda
4.
J Cardiovasc Dev Dis ; 9(2)2022 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-35200687

RESUMEN

BACKGROUND: Pediatric patients with cardiomyopathies are at risk of malignant arrhythmias and sudden cardiac death (SCD). An ICD may prevent SCD. The aim of this study was to evaluate ICD implantation outcomes, and to compare transvenous and subcutaneous ICDs (S-ICDs) implanted in pediatric patients with cardiomyopathies. METHODS: The study is single center and retrospective, and includes pediatric patients with cardiomyopathies who required ICD implantation (2010-2021). Outcomes were recorded for appropriate/inappropriate ICD therapy and surgical complications. Transvenous ICD and S-ICD were compared. Data are presented as median values (25th-75th centiles). RESULTS: Forty-four patients with cardiomyopathies (hypertrophic 39%, arrhythmogenic 32%, dilated 27%, and restrictive 2%) underwent transvenous (52%) and S-ICD (48%) implantation at 14 (12-17) years of age, mostly for primary prevention (73%). The follow-up period was 29 (14-60) months. Appropriate ICD therapies were delivered in 25% of patients, without defibrillation failures. Lower age at implantation and secondary prevention were significant risk factors for malignant ventricular arrhythmias that required appropriate ICD therapies. ICD-related complications were surgical complications (18%) and inappropriate shocks (7%). No significant differences in outcomes were recorded, either when comparing transvenous and S-ICD or comparing the different cardiomyopathies. CONCLUSIONS: In pediatric patients with cardiomyopathy, ICD therapy is effective, with a low rate of inappropriate shocks. Neither ICD type (transvenous and S-ICDs) nor the cardiomyopathies subgroup revealed divergent outcomes.

5.
Rev Cardiovasc Med ; 23(1): 27, 2022 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-35092219

RESUMEN

BACKGROUND: Remote monitoring-enabled insertable cardiac monitors (ICMs) are useful tools for arrhythmias and symptom management. This study sought to evaluate the outcome of ICM implantation in a large, heterogeneous cohort of pediatric and young adult patients. METHODS: Single centre, retrospective analysis of patients who underwent ICM implantation in 2010-2019. Patients were analysed according to age, symptoms, arrhythmias and underlying heart disease. RESULTS: A total of 200 consecutive patients (58% male), aged 11.5 ± 5.8 years at ICM implantation, were included. Follow-up was 31 ± 18 months. Electrophysiologic study (EPS) was initially performed in 123 patients and was negative in 85%. Patients had no heart disease (57.5%), congenital heart defects (21%), channelopathies (14.5%), cardiomyopathies/heart tumors (8%). The commonest symptoms were syncope/presyncope (45.5%) and palpitations (12.5%). A definite diagnosis was made in 63% of patients (positive diagnosis in 25%, negative in 38%) after 8 (2-19) months of monitoring. EPS results and the presence/absence of an arrhythmia before ICM implantation had no impact on the diagnostic yield. Symptomatic patients as well as patients without structural heart disease showed higher diagnostic yield. Patients with a positive diagnosis underwent pacemaker/implantable cardioverter-defibrillator implantation (13%), pharmacological treatment (10.5%), or catheter ablation (1.5%). CONCLUSIONS: In a large cohort of 200 children and young adults, ICMs with remote monitoring showed a high diagnostic yield (63%), especially in symptomatic patients and in patients without structural heart disease.


Asunto(s)
Arritmias Cardíacas , Cardiopatías Congénitas , Adolescente , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Niño , Preescolar , Femenino , Humanos , Masculino , Estudios Retrospectivos , Síncope/diagnóstico , Síncope/terapia , Adulto Joven
6.
Pediatr Cardiol ; 39(8): 1590-1597, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29948031

RESUMEN

Atrioventricular Septal Defect (AVSD) is a rare congenital heart defect (CHD) often associated with genetic syndromes, most commonly Down syndrome (DS). Over the last four decades, surgical repair has increased survival and improved quality of life in these patients. The prevalence of bradyarrhythmias namely, atrioventricular block (AVB) and sinus node dysfunction (SND) in AVSD is partially known. 522 cases with both partial and complete AVSD (38.7% with DS), undergoing intracardiac repair from 1982 to 2016 at our institution, were reviewed from our system database. 38 (7.3%) patients received permanent PM implantation for AVB (early or late) or SND. On one hand, AVB requiring PM was found in 26 (4.98%). This was further subdivided into early-onset 14 (2.6%) and late-onset AVB 12 (2.2%) (median 4 [IQR 1-7] years). On the other hand, 12 (2.3%) experienced late SND requiring PM (median 11 [IQR 3.5-15.2] years). Early and late AVB were independent from the type of AVSD (partial or complete), whereas the late SND was remarkably observed in complete AVSD compared to partial AVSD (p = 0.017). We classified the cohort into two main categories: DS (202, 38.7%) and non-DS (320, 61.3%). At Kaplan-Meier survival analysis, DS was significantly associated with late-onset bradyarrhythmias (p = 0.024). At Cox regression analysis, we identified DS as an independent predictor of PM implantation (HR 2.17). In conclusion, about 7% of repaired AVSD patients need PM implantation during follow-up. There are no differences in early and late AVB occurrence according to the type of AVSD. There is a higher incidence of late SND in repaired complete AVSD, with a later timing onset in patients with associated DS. Moreover, DS seems to be an independent predictor of PM implantation.


Asunto(s)
Bloqueo Atrioventricular/etiología , Bradicardia/etiología , Defectos de los Tabiques Cardíacos/cirugía , Síndrome del Seno Enfermo/etiología , Procedimientos Quirúrgicos Vasculares/efectos adversos , Niño , Preescolar , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Defectos de los Tabiques Cardíacos/fisiopatología , Humanos , Lactante , Estimación de Kaplan-Meier , Masculino , Marcapaso Artificial/estadística & datos numéricos , Calidad de Vida , Estudios Retrospectivos , Síndrome del Seno Enfermo/complicaciones , Factores de Tiempo
8.
Pacing Clin Electrophysiol ; 39(7): 669-74, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27062386

RESUMEN

BACKGROUND: The etiological diagnosis of syncope and/or palpitations in children is often challenging. However, when noninvasive conventional examinations are inconclusive, the subcutaneous miniaturized implantable loop recorder (ILR) is recommended. The aim of our study was to evaluate the efficacy of miniaturized cardiac implantable devices in the early diagnosis of arrhythmias in children ≤6 years. METHODS: From March 2014 to May 2015, 21 patients (median age 5 years) underwent implantation of miniaturized ILR at our Institution after a complete cardiac work up. Median follow-up was 10 months. RESULTS: One patient underwent device removal for pocket infection and one needed a pocket revision. Eleven (52%) patients did not show any symptom and/or arrhythmia. Eight patients experienced symptoms during ILR monitoring: six had no electrocardiographic abnormalities, two had significant sinus pauses. Two patients had significant arrhythmias without symptoms and in one of these a pacemaker was implanted. The overall diagnostic yield was 47%. CONCLUSIONS: Miniaturized ILR could be very useful to make a diagnosis and to decide future management strategies in small patients with undefined symptoms or severe cardiac diseases. Considering its characteristics, miniaturized ILR could start a new era in the diagnosis and follow-up of young patients with symptomatic and/or malignant arrhythmias.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía Ambulatoria/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Prótesis e Implantes , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/prevención & control , Niño , Preescolar , Muerte Súbita Cardíaca/etiología , Diagnóstico Precoz , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Almacenamiento y Recuperación de la Información , Masculino , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...