Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 70
1.
Article En | MEDLINE | ID: mdl-38650055

BACKGROUND: The ONCO DVT study revealed the superiority of 12-month relative to 3-month edoxaban treatment for cancer-associated isolated distal deep vein thrombosis (DVT) regarding the thrombotic risk. METHODS: In this pre-specified subgroup analysis of the ONCO DVT study, we stratified the patients into those with a standard edoxaban dose (60 mg/day; N=151) and those with a reduced edoxaban dose (30 mg/day; N=450) and evaluated the clinical outcomes for the 12-month and 3-month treatments. RESULTS: The cumulative 12-month incidence of symptomatic recurrent venous thromboembolism was lower in the 12-month than 3-month group for both the 60 mg (1.3% vs. 11.6%, P=0.02; odds ratio [OR], 0.12; 95% CI, 0.01-0.97) and 30 mg (1.1% vs. 7.6%, P=0.002; OR, 0.14; 95% CI, 0.03-0.60) edoxaban subgroups, which was consistent across the edoxaban doses without a significant interaction (P =0.90). The 12-month cumulative incidence of major bleeding was higher in the 12-month group than 3-month group for the 60 mg edoxaban subgroup (14.3% vs. 4.4%, P=0.046; OR, 3.61; 95% CI, 0.97-13.52), whereas it did not significantly differ between the two groups for the 30 mg edoxaban subgroup (8.7% vs. 8.6%, P=0.89; OR, 0.97; 95% CI, 0.49-1.91), signaling there was a potential interaction (P=0.07). CONCLUSIONS: A 12-month edoxaban regimen for cancer-associated isolated distal DVT was consistently superior to a 3-month regimen, across the edoxaban doses for the thrombotic risk. However, caution was suggested for the standard dose of edoxaban due to the potential for an increased risk of bleeding with prolonged anticoagulation therapy.

2.
Circ J ; 2024 Mar 08.
Article En | MEDLINE | ID: mdl-38462535

BACKGROUND: Patients with appropriately selected low-risk pulmonary embolism (PE) can be treated at home, although it has been controversial whether applies to patients with cancer, who are considered not to be at low risk.Methods and Results: The current predetermined companion report from the ONCO PE trial evaluated the 3-month clinical outcomes of patients with home treatment and those with in-hospital treatment. The ONCO PE trial was a multicenter, randomized clinical trial among 32 institutions in Japan investigating the optimal duration of rivaroxaban treatment in cancer-associated PE patients with a score of 1 using the simplified version of the Pulmonary Embolism Severity Index (sPESI). Among 178 study patients, there were 66 (37%) in the home treatment group and 112 (63%) in the in-hospital treatment group. The primary endpoint of a composite of PE-related death, recurrent venous thromboembolism (VTE) and major bleeding occurred in 3 patients (4.6% [0.0-9.6%]) in the home treatment group and in 2 patients (1.8% [0.0-4.3%]) in the in-hospital treatment group. In the home treatment group, there were no cases of PE-related death or recurrent VTE, but major bleeding occurred in 3 patients (4.6% [0.0-9.6%]), and 2 patients (3.0% [0.0-7.2%]) required hospitalization due to bleeding events. CONCLUSIONS: Active cancer patients with PE of sPESI score=1 could be potential candidates for home treatment.

4.
Thromb Res ; 235: 107-115, 2024 Mar.
Article En | MEDLINE | ID: mdl-38335565

BACKGROUND: The multicenter, open-label, randomized clinical trial ONCO DVT compared 3-month and 12-month edoxaban treatment regimens for isolated distal deep vein thrombosis (DVT) and suggested potential benefits of prolonged edoxaban treatment in terms of thrombotic risk. However, the risk-benefit balance of prolonged edoxaban treatment in patients with renal function remains unclear. OBJECTIVES: To compare the safety and efficacy of 3-month and 12-month edoxaban treatment regimens in patients with cancer-associated isolated distal DVT and different renal functions. METHODS: This pre-specified subgroup analysis of the ONCO DVT study included 601 patients divided into subgroups according to renal function using a 50 mL/min creatinine clearance (Ccr) cutoff. The primary endpoint was symptomatic recurrent venous thromboembolism (VTE) and VTE-related death at 12 months and the major secondary endpoint was major bleeding at 12 months. RESULTS: Among the 601 patients, 131 (21.8 %) comprised the renal dysfunction subgroup. The primary endpoint occurred in 6 (9.7 %) and 1 (1.4 %) patients in the 3-month and 12-month edoxaban groups in the renal dysfunction subgroup, respectively, and in 16 (6.6 %) and 2 (0.9 %) patients in the no renal dysfunction subgroup, respectively. The major secondary endpoint occurred in 9 (14.5 %) and 7 (10.1 %) patients in the 12-month and 3-month edoxaban groups in the renal dysfunction subgroup, and in 13 (5.3 %) and 21 (9.3 %) patients in the no renal dysfunction subgroup, respectively. CONCLUSIONS: A 12-month edoxaban regiment was superior to a 3-month treatment in terms of thrombotic risk irrespective of renal function. A higher bleeding risk was not identified in patients with renal dysfunction who received prolonged edoxaban treatment.


Kidney Diseases , Neoplasms , Pyridines , Thiazoles , Venous Thromboembolism , Venous Thrombosis , Humans , Neoplasms/complications , Venous Thrombosis/drug therapy , Venous Thrombosis/etiology , Kidney
5.
Cardiovasc. revasc. med ; 59: 60-66, fev.2024. ilus, tab
Article En | CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1527062

BACKGROUND: Landmark trials showed that invasive pressure measurement (Fractional Flow Reserve, FFR) was a better guide to coronary stenting than visual assessment. However, present-day interventionists have benefited from extensive research and personal experience of mapping anatomy to hemodynamics. AIMS: To determine if visual assessment of the angiogram performs as well as invasive measurement of coronary physiology. METHODS: 25 interventional cardiologists independently visually assessed the single vessel coronary disease of 200 randomized participants in The Objective Randomized Blinded Investigation with optimal medical Therapy of Angioplasty in stable angina trial (ORBITA). They gave a visual prediction of the FFR and Instantaneous Wave-free Ratio (iFR), denoted vFFR and viFR respectively. Each judged each lesion on 2 occasions, so that every lesion had 50 vFFR, and 50 viFR assessments. The group consensus visual estimates (vFFR-group and viFR-group) and individual cardiologists' visual estimates (vFFR-individual and viFR-individual) were tested alongside invasively measured FFR and iFR for their ability to predict the placebo-controlled reduction in stress echo ischemia with stenting. RESULTS: Placebo-controlled ischemia improvement with stenting was predicted by vFFR-group (p < 0.0001) and viFR-group (p < 0.0001), vFFR-individual (p < 0.0001) and viFR-individual (p < 0.0001). There were no significant differences between the predictive performance of the group visual estimates and their invasive counterparts: p = 0.53 for vFFR vs FFR and p = 0.56 for viFR vs iFR. CONCLUSION: Visual assessment of the angiogram by contemporary experts, provides significant additional information on the amount of ischaemia which can be relieved by placebo-controlled stenting in single vessel coronary artery disease.


Coronary Artery Disease/diagnostic imaging , Fractional Flow Reserve, Myocardial , Severity of Illness Index , Coronary Stenosis
6.
Cardiovasc Revasc Med ; 59: 60-66, 2024 Feb.
Article En | MEDLINE | ID: mdl-37612169

BACKGROUND: Landmark trials showed that invasive pressure measurement (Fractional Flow Reserve, FFR) was a better guide to coronary stenting than visual assessment. However, present-day interventionists have benefited from extensive research and personal experience of mapping anatomy to hemodynamics. AIMS: To determine if visual assessment of the angiogram performs as well as invasive measurement of coronary physiology. METHODS: 25 interventional cardiologists independently visually assessed the single vessel coronary disease of 200 randomized participants in The Objective Randomized Blinded Investigation with optimal medical Therapy of Angioplasty in stable angina trial (ORBITA). They gave a visual prediction of the FFR and Instantaneous Wave-free Ratio (iFR), denoted vFFR and viFR respectively. Each judged each lesion on 2 occasions, so that every lesion had 50 vFFR, and 50 viFR assessments. The group consensus visual estimates (vFFR-group and viFR-group) and individual cardiologists' visual estimates (vFFR-individual and viFR-individual) were tested alongside invasively measured FFR and iFR for their ability to predict the placebo-controlled reduction in stress echo ischemia with stenting. RESULTS: Placebo-controlled ischemia improvement with stenting was predicted by vFFR-group (p < 0.0001) and viFR-group (p < 0.0001), vFFR-individual (p < 0.0001) and viFR-individual (p < 0.0001). There were no significant differences between the predictive performance of the group visual estimates and their invasive counterparts: p = 0.53 for vFFR vs FFR and p = 0.56 for viFR vs iFR. CONCLUSION: Visual assessment of the angiogram by contemporary experts, provides significant additional information on the amount of ischaemia which can be relieved by placebo-controlled stenting in single vessel coronary artery disease.


Cardiologists , Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Humans , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Ischemia , Predictive Value of Tests , Severity of Illness Index
7.
Cardiovasc Revasc Med ; 58: 68-76, 2024 Jan.
Article En | MEDLINE | ID: mdl-37500393

BACKGROUND: Aortic stenosis (AS) and chronic kidney disease (CKD) can coexist. Repeat exposure to contrast media in patients undergoing transcatheter aortic valve implantation (TAVI) has latent mortality risks and increased risk for acute kidney injury. We aimed to assess our "zero-contrast TAVI" protocol for patients with advanced CKD. METHODS: Consecutive patients with severe AS who underwent TAVI at a single center registry were enrolled. Zero-contrast TAVI group included patients who underwent TAVI without contrast and who had an estimated glomerular filtration rate <30 mL/min/1.73 m2. Conventional TAVI group included patients who underwent the regular TAVI procedure. Patients using balloon-expandable valves via transfemoral approach were analyzed. Baseline clinical and procedural characteristics and clinical outcomes were compared between two groups. The primary outcome was early safety as defined by Valve Academic Research Consortium Criteria. Secondary outcomes included the presence of severe prosthesis-patient mismatch, moderate or greater perivalvular leakage, and requirement for new dialysis (within 3 months). RESULTS: A total of 520 patients were analyzed. Among these, 32 (6 %) underwent zero-contrast TAVI and 488 (94 %) conventional TAVI. In the zero-contrast TAVI group, 12 patients (37.5 %) had to use 20.7 (11.0-31.2) mL of contrast media. There were no significant differences in the primary and secondary outcomes between zero-contrast TAVI and conventional TAVI groups (78.1 % vs. 86.8 %, P = 0.184 and 9.4 % vs. 8.1 %, P = 0.738 for the primary and secondary outcomes, respectively). CONCLUSIONS: Zero-contrast TAVI is feasible, safe, and effective in patients with AS and stage 4 CKD.


Aortic Valve Stenosis , Heart Valve Prosthesis , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Humans , Feasibility Studies , Contrast Media/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/therapy , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome
8.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Article En | MEDLINE | ID: mdl-37438144

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Heart Failure , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Angiography , Heart Failure/diagnostic imaging , Kaplan-Meier Estimate , Kidney/diagnostic imaging , Treatment Outcome
9.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Article En | MEDLINE | ID: mdl-38008428

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Proportional Hazards Models , Cardiac Catheterization
10.
Cardiovasc Interv Ther ; 39(1): 74-82, 2024 Jan.
Article En | MEDLINE | ID: mdl-37938532

The safety and feasibility are still not well known for exercise-induced mitral regurgitation (MR). This study is aimed to assess and compare the hemodynamic and symptomatic changes in patients with significant secondary MR during exercise stress echocardiography (ESE) before and after transcatheter edge-to-edge repair (TEER). The study included a total of 15 patients with secondary MR who underwent ESE before and after TEER using the MitraClip system (Abbott, Abbott Park, IL, USA). Echocardiographic data of ESE were collected both before the procedure and during the follow-up visit at 3 months. During the one-year postoperative observation period, the rate of readmission due to heart failure was 13% (n = 2), with no recorded fatalities. Although no significant differences of ESE data were observed in exercise-induced pulmonary hypertension or cardiac output before and after the repair, the severity of MR was significantly improved after the procedure, both at rest (2 [2-3] vs. 1 [1-2], p = 0.0125) and during ESE (3 [3-3] vs. 1 [1-1], p < 0.0001). Furthermore, the New York Heart Association Functional Classification was improved (3 [3-3] vs. 1 [1-1], p < 0.0001) after treatment. For a supplemental analysis, MR during ESE was significantly improved not only in cases with atrial secondary MR but also in ventricular secondary MR. Transcatheter edge-to-edge repair for exercise-induced MR resulted in a significant improvement in postoperative MR severity and subjective symptoms. These results are novel, as they have not been extensively reported previously, particularly among Japanese patients.


Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Echocardiography, Stress , Treatment Outcome , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/surgery , Echocardiography , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization
11.
Am J Cardiol ; 210: 259-265, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-37875233

Aortic stenosis is a prevalent valvular heart disease, especially in the older people. They often coexist with other co-morbidities, and noncardiac surgery carries a higher risk because of the underlying valve condition. Despite the growing concern about the safety and optimal management of noncardiac surgery post-transcatheter aortic valve replacement (TAVR), there is limited evidence on this matter. This study aims to assess the clinical outcomes of noncardiac surgeries after TAVR. This retrospective study included 718 patients who underwent TAVR. Of these, 36 patients underwent noncardiac surgery after TAVR. The primary end point was the incidence of cardiovascular adverse events post-TAVR and the secondary end point was the incidence of structural valve deterioration. Composite end points included disabling stroke, heart failure requiring hospitalization, and cardiac death as defined by Valve Academic Research Consortium 3. Most of these surgeries were orthopedic and classified as intermediate risk. All noncardiac surgeries were performed without perioperative adverse events. There was no observed structural valve deterioration, and the incidence of composite end points did not significantly differ between the surgical and nonsurgical groups during the follow-up period. Noncardiac surgery after TAVR can be performed safely and does not have a negative impact on prognosis. Further studies are warranted to determine the optimal strategy for noncardiac surgery after TAVR.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Prevalence , Risk Factors , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Treatment Outcome , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects
12.
Circ Rep ; 5(12): 442-449, 2023 Dec 08.
Article En | MEDLINE | ID: mdl-38073869

Background: A high score for controlling nutritional status (CONUT) due to poor nutritional status has been associated with adverse outcomes in patients with chronic heart failure. However, because little is known about the effect of CONUT score on mortality rates after transcatheter mitral valve repair, we evaluated nutrition screening tools for prognosis prediction in patients undergoing transcatheter mitral valve repair using the MitraClipTM system. Methods and Results: We retrospectively analyzed 148 patients with severe mitral regurgitation (MR) who underwent MitraClipTM implantation between April 2018 and April 2021. The preprocedural CONUT scores were assessed at the time of hospitalization, the primary outcome was all-cause death, and the analysis was of the mortality and incidence rates of cardiac events 1 year post-operation. Functional MR was of ischemic origin in the majority of patients (69.6%), with a mean left ventricular ejection fraction of 48.9±15.8%. Kaplan-Meier curves indicated that all-cause death was significantly worse in the high-CONUT score group than in the low-CONUT score group. Cox hazard analysis showed a significant association between all-cause death and CONUT score, as well as MitraScore. Conclusions: Preprocedural CONUT score, as well as MitraScore, in patients undergoing transcatheter edge-to-edge mitral valve repair may predict an increased risk of all-cause death. This knowledge should allow the heart team to accurately assess the clinical implications and prognostic benefits of the procedure in individual patients.

13.
Sci Rep ; 13(1): 20602, 2023 11 23.
Article En | MEDLINE | ID: mdl-37996502

Weather conditions influence the incidence of cardiovascular disease. However, few studies have investigated the association between weather temperature and humidity and cerebrovascular disease hospitalizations in a super-aging society. We included 606,807 consecutive patients with cerebrovascular disease admitted to Japanese acute-care hospitals between 2015 and 2019. The primary outcome was the number of cerebrovascular disease hospitalizations per day. Multilevel mixed-effects linear regression models were used to estimate the association of mean temperature and humidity, 1 day before hospital admission, with cerebrovascular disease hospitalizations, after adjusting for air pollution, hospital, and patient demographics. Lower mean temperatures and humidity < 70% or humidity ≧ 70% are associated with an increased incidence of cerebrovascular disease hospitalization (coefficient, - 1.442 [- 1.473 to - 1.411] per °C, p < 0.001, coefficient, - 0.084 [- 0.112 to - 0.056] per%, p < 0.001, and coefficient, 0.136 [0.103 to 0.168] per %, p < 0.001, respectively). Lower mean temperatures and extremely lower or higher humidity are associated with an increased incidence of cerebrovascular disease hospitalization in a super-aging society.


Cerebrovascular Disorders , Hospitalization , Humans , Aging , Cerebrovascular Disorders/epidemiology , Humidity , Temperature , Weather
14.
Circ Rep ; 5(9): 358-364, 2023 Sep 08.
Article En | MEDLINE | ID: mdl-37693232

Background: Very severe aortic stenosis (AS) has a poor prognosis even in asymptomatic patients, and asymptomatic very severe AS is a Class IIa indication for aortic valve replacement, although the safety and effectiveness of transcatheter aortic valve implantation (TAVI) for very severe AS is not well-established. Methods and Results: This study included 366 patients undergoing TAVI at a single center, with 85 and 281 patients in the very severe AS (peak velocity ≥5 m/s or mean pressure gradient (PG) ≥60 mmHg) and severe AS groups, respectively. Procedural and clinical outcomes at 1-year follow-up were compared between groups. The calcium scores were significantly higher in the very severe AS group (2,864.5 vs. 1,405.8 arbitrary units [AU] (P<0.001). Although the patient-prosthesis mismatch rate was higher in the very severe AS group (38.3% vs. 25.7%; P=0.029), there was no significant difference in the early safety and clinical efficacy between the groups (16.5% vs. 17.1% and 12.0% vs. 18.9%, respectively). Similarly, there was no significant difference in all-cause mortality at 1 year (4.8% vs. 9.8%). Conclusions: Despite a higher incidence of prosthesis-patient mismatch in those with very severe AS, the procedural and clinical outcomes were comparable to those in patients with severe AS. TAVI may be a reasonable treatment option for very severe AS.

15.
Circulation ; 148(21): 1665-1676, 2023 11 21.
Article En | MEDLINE | ID: mdl-37638968

BACKGROUND: The optimal duration of anticoagulation therapy for isolated distal deep vein thrombosis in patients with cancer is clinically relevant, but the evidence is lacking. The prolonged anticoagulation therapy could have a potential benefit for prevention of thrombotic events; however, it could also increase the risk of bleeding. METHODS: In a multicenter, open-label, adjudicator-blinded, randomized clinical trial at 60 institutions in Japan, we randomly assigned patients with cancer with isolated distal deep vein thrombosis, in a 1-to-1 ratio, to receive either a 12-month or 3-month edoxaban treatment. The primary end point was a composite of a symptomatic recurrent venous thromboembolism (VTE) or VTE-related death at 12 months. The major secondary end point was major bleeding at 12 months, according to the criteria of the International Society on Thrombosis and Haemostasis. The primary hypothesis was that a 12-month edoxaban treatment was superior to a 3-month edoxaban treatment with respect to the primary end point. RESULTS: From April 2019 through June 2022, 604 patients were randomized, and after excluding 3 patients who withdrew consent, 601 patients were included in the intention-to-treat population: 296 patients in the 12-month edoxaban group and 305 patients in the 3-month edoxaban group. The mean age was 70.8 years, 28% of the patients were men, and 20% of the patients had symptoms of deep vein thrombosis at baseline. The primary end point of a symptomatic recurrent VTE event or VTE-related death occurred in 3 of the 296 patients (1.0%) in the 12-month edoxaban group and in 22 of the 305 patients (7.2%) in the 3-month edoxaban group (odds ratio, 0.13; 95% CI, 0.03-0.44). The major secondary end point of major bleeding occurred in 28 of the 296 patients (9.5%) in the 12-month edoxaban group and in 22 of the 305 patients (7.2%) in the 3-month edoxaban group (odds ratio, 1.34; 95% CI, 0.75-2.41). The prespecified subgroups did not affect the estimates on the primary end point. CONCLUSIONS: In patients with cancer with isolated distal deep vein thrombosis, 12 months was superior to 3 months for an edoxaban treatment with respect to the composite outcome of a symptomatic recurrent VTE or VTE-related death. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03895502.


Neoplasms , Thrombosis , Venous Thromboembolism , Venous Thrombosis , Male , Humans , Aged , Female , Anticoagulants/adverse effects , Venous Thromboembolism/drug therapy , Venous Thromboembolism/complications , Hemorrhage/complications , Thrombosis/complications , Venous Thrombosis/complications , Neoplasms/complications , Neoplasms/drug therapy
18.
Circ J ; 87(4): 517-524, 2023 03 24.
Article En | MEDLINE | ID: mdl-36624061

BACKGROUND: Transesophageal echocardiography (TEE) has been used for percutaneous atrial septal defect (ASD) closure, with intracardiac echocardiography (ICE) guidance recently being introduced.Methods and Results: The Japanese Structural Heart Disease Registry was established by the Japanese Association of Cardiovascular Intervention and Therapeutics. This study analyzed data from the Registry for 2,859 consecutive cases undergoing percutaneous ASD closure between January 2015 and December 2020. ASD closure was performed under ICE guidance (n=519; 18.2%), TEE guidance (n=1,428; 49.9%), or TEE plus ICE guidance ("Both"; n=900 cases; 31.5%). The success rates were similar in the TEE, ICE, and both groups (99.0%, 99.2%, vs. 98.0%, respectively; P=0.054), as were complication rates (1.2%, 0.5%, vs. 2.1%, respectively; P=0.24). In the TEE and Both groups, 92.4% and 79.6% of patients required general anesthesia, compared with only 2.9% of patients in the ICE group (P<0.001). Fluoroscopic time was longer in the ICE and Both groups than in the TEE group (median [interquartile range] 19 [14-28] and 21 [13-30] vs. 12 [8-19] min, respectively; P<0.001). Rim deficiency and larger defect diameter were inversely related, whereas hospital volume was positively related to ICE guidance. CONCLUSIONS: Percutaneous transcatheter ASD closure was as feasible under ICE as under TEE guidance. ICE guidance is used for less challenging cases in high-volume centers in Japan.


Cardiac Catheterization , Heart Septal Defects, Atrial , Humans , Cardiac Catheterization/methods , Treatment Outcome , Echocardiography, Transesophageal/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Fluoroscopy
19.
J Invasive Cardiol ; 34(2): E151, 2022 02.
Article En | MEDLINE | ID: mdl-35100559

The current guidelines recommend at least 6 months of antithrombotic and antibiotic prophylaxis following atrial septal occluding device placement using the phrase "until endothelialization." However, neo-endothelialization has not been assessed in vivo in humans. Considering the atrial septal defect occluding device, several autopsy cases and device extraction cases only demonstrated insufficient endothelialization beyond 6 months after implantation caused endocarditis and thrombosis. Accordingly, we have successfully developed a method for determining device endothelialization using angioscopy. This method helped us evaluate the endothelialization of a 25 mm Amplatzer PFO occluder device (Abbott) in a 40-year-old man 12 months after implantation. This is the first report evaluating the PFO occluder device in vivo.


Foramen Ovale, Patent , Septal Occluder Device , Adult , Angioscopy , Cardiac Catheterization/methods , Humans , Male , Septal Occluder Device/adverse effects , Treatment Outcome
...