Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Biophotonics ; 12(7): e201800479, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30719868

RESUMEN

A growing body of evidence has substantiated the significance of quantitative phase imaging (QPI) in enabling cost-effective and label-free cellular assays, which provides useful insights into understanding the biophysical properties of cells and their roles in cellular functions. However, available QPI modalities are limited by the loss of imaging resolution at high throughput and thus run short of sufficient statistical power at the single-cell precision to define cell identities in a large and heterogeneous population of cells-hindering their utility in mainstream biomedicine and biology. Here we present a new QPI modality, coined multiplexed asymmetric-detection time-stretch optical microscopy (multi-ATOM) that captures and processes quantitative label-free single-cell images at ultrahigh throughput without compromising subcellular resolution. We show that multi-ATOM, based upon ultrafast phase-gradient encoding, outperforms state-of-the-art QPI in permitting robust phase retrieval at a QPI throughput of >10 000 cell/sec, bypassing the need for interferometry which inevitably compromises QPI quality under ultrafast operation. We employ multi-ATOM for large-scale, label-free, multivariate, cell-type classification (e.g. breast cancer subtypes, and leukemic cells vs peripheral blood mononuclear cells) at high accuracy (>94%). Our results suggest that multi-ATOM could empower new strategies in large-scale biophysical single-cell analysis with applications in biology and enriching disease diagnostics.


Asunto(s)
Espacio Intracelular/metabolismo , Microscopía/métodos , Análisis de la Célula Individual/métodos , Humanos , Células MCF-7 , Fenotipo
2.
Biomed Opt Express ; 8(9): 4160-4171, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28966855

RESUMEN

Apart from the spatial resolution enhancement, scaling of temporal resolution, equivalently the imaging throughput, of fluorescence microscopy is of equal importance in advancing cell biology and clinical diagnostics. Yet, this attribute has mostly been overlooked because of the inherent speed limitation of existing imaging strategies. To address the challenge, we employ an all-optical laser-scanning mechanism, enabled by an array of reconfigurable spatiotemporally-encoded virtual sources, to demonstrate ultrafast fluorescence microscopy at line-scan rate as high as 8 MHz. We show that this technique enables high-throughput single-cell microfluidic fluorescence imaging at 75,000 cells/second and high-speed cellular 2D dynamical imaging at 3,000 frames per second, outperforming the state-of-the-art high-speed cameras and the gold-standard laser scanning strategies. Together with its wide compatibility to the existing imaging modalities, this technology could empower new forms of high-throughput and high-speed biological fluorescence microscopy that was once challenged.

3.
J Vis Exp ; (124)2017 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-28715367

RESUMEN

Scaling the number of measurable parameters, which allows for multidimensional data analysis and thus higher-confidence statistical results, has been the main trend in the advanced development of flow cytometry. Notably, adding high-resolution imaging capabilities allows for the complex morphological analysis of cellular/sub-cellular structures. This is not possible with standard flow cytometers. However, it is valuable for advancing our knowledge of cellular functions and can benefit life science research, clinical diagnostics, and environmental monitoring. Incorporating imaging capabilities into flow cytometry compromises the assay throughput, primarily due to the limitations on speed and sensitivity in the camera technologies. To overcome this speed or throughput challenge facing imaging flow cytometry while preserving the image quality, asymmetric-detection time-stretch optical microscopy (ATOM) has been demonstrated to enable high-contrast, single-cell imaging with sub-cellular resolution, at an imaging throughput as high as 100,000 cells/s. Based on the imaging concept of conventional time-stretch imaging, which relies on all-optical image encoding and retrieval through the use of ultrafast broadband laser pulses, ATOM further advances imaging performance by enhancing the image contrast of unlabeled/unstained cells. This is achieved by accessing the phase-gradient information of the cells, which is spectrally encoded into single-shot broadband pulses. Hence, ATOM is particularly advantageous in high-throughput measurements of single-cell morphology and texture - information indicative of cell types, states, and even functions. Ultimately, this could become a powerful imaging flow cytometry platform for the biophysical phenotyping of cells, complementing the current state-of-the-art biochemical-marker-based cellular assay. This work describes a protocol to establish the key modules of an ATOM system (from optical frontend to data processing and visualization backend), as well as the workflow of imaging flow cytometry based on ATOM, using human cells and micro-algae as the examples.


Asunto(s)
Citometría de Flujo/métodos , Microfluídica/métodos , Microscopía/métodos , Imagen Óptica/métodos , Humanos
4.
Biomed Opt Express ; 8(2): 640-652, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-28270973

RESUMEN

Cell-based assay based on time-stretch imaging is recognized to be well-suited for high-throughput phenotypic screening. However, this ultrafast imaging technique has primarily been limited to suspension-cell assay, leaving a wide range of solid-substrate assay formats uncharted. Moreover, time-stretch imaging is generally restricted to intrinsic biophysical phenotyping, but lacks the biomolecular signatures of the cells. To address these challenges, we develop a spinning time-stretch imaging assay platform based on the functionalized digital versatile disc (DVD). We demonstrate that adherent cell culture and biochemically-specific cell-capture can now be assayed with time-stretch microscopy, thanks to the high-speed DVD spinning motion that naturally enables on-the-fly cellular imaging at an ultrafast line-scan rate of >10MHz. As scanning the whole DVD at such a high speed enables ultra-large field-of-view imaging, it could be favorable for scaling both the assay throughput and content as demanded in many applications, e.g. drug discovery, and rare cancer cell screening.

5.
Opt Express ; 24(25): 28170-28184, 2016 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-27958529

RESUMEN

Time-stretch imaging has been regarded as an attractive technique for high-throughput imaging flow cytometry primarily owing to its real-time, continuous ultrafast operation. Nevertheless, two key challenges remain: (1) sufficiently high time-stretch image resolution and contrast is needed for visualizing sub-cellular complexity of single cells, and (2) the ability to unravel the heterogeneity and complexity of the highly diverse population of cells - a central problem of single-cell analysis in life sciences - is required. We here demonstrate an optofluidic time-stretch imaging flow cytometer that enables these two features, in the context of high-throughput multi-class (up to 14 classes) phytoplantkton screening and classification. Based on the comprehensive feature extraction and selection procedures, we show that the intracellular texture/morphology, which is revealed by high-resolution time-stretch imaging, plays a critical role of improving the accuracy of phytoplankton classification, as high as 94.7%, based on multi-class support vector machine (SVM). We also demonstrate that high-resolution time-stretch images, which allows exploitation of various feature domains, e.g. Fourier space, enables further sub-population identification - paving the way toward deeper learning and classification based on large-scale single-cell images. Not only applicable to biomedical diagnostic, this work is anticipated to find immediate applications in marine and biofuel research.


Asunto(s)
Citometría de Flujo/métodos , Fitoplancton , Máquina de Vectores de Soporte , Algoritmos , Reconocimiento de Normas Patrones Automatizadas/métodos , Análisis de la Célula Individual
6.
Sci Rep ; 4: 3656, 2014 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-24413677

RESUMEN

Accelerating imaging speed in optical microscopy is often realized at the expense of image contrast, image resolution, and detection sensitivity--a common predicament for advancing high-speed and high-throughput cellular imaging. We here demonstrate a new imaging approach, called asymmetric-detection time-stretch optical microscopy (ATOM), which can deliver ultrafast label-free high-contrast flow imaging with well delineated cellular morphological resolution and in-line optical image amplification to overcome the compromised imaging sensitivity at high speed. We show that ATOM can separately reveal the enhanced phase-gradient and absorption contrast in microfluidic live-cell imaging at a flow speed as high as ~10 m/s, corresponding to an imaging throughput of ~100,000 cells/sec. ATOM could thus be the enabling platform to meet the pressing need for intercalating optical microscopy in cellular assay, e.g. imaging flow cytometry--permitting high-throughput access to the morphological information of the individual cells simultaneously with a multitude of parameters obtained in the standard assay.


Asunto(s)
Microscopía/métodos , Imagen Óptica/métodos , Células Sanguíneas , Línea Celular , Humanos , Microscopía/instrumentación , Imagen Óptica/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA