Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Heart Rhythm O2 ; 5(5): 257-265, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38840763

RESUMEN

Background: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology. Its potential value for repeat procedures after unsuccessful thermal ablation for atrial fibrillation has not been assessed. Objective: The purpose of this study was to summarize our initial experience with patients undergoing repeat procedures using PFA. Methods: Consecutive patients with arrhythmia recurrences after a prior thermal ablation undergoing a repeat procedure using a multipolar PFA catheter from May 2021 and December 2022 were included. After 3-dimensional electroanatomic mapping, reconnected pulmonary veins (PVs) were reisolated and veins with only ostial isolation wither ablated to widen antral PV isolation. Posterior wall ablation was performed if all PVs were durably isolated or in case of low-voltage areas on the posterior wall at the discretion of the operator. Patients underwent follow-up with 7-day Holter electrocardiography after 3, 6, and 12 months. Results: A total of 186 patients undergoing a repeat procedure using PFA were included. The median number of previous ablations was 1 (range 1-6). The prior ablation modality was radiofrequency in 129 patients (69.4%), cryoballoon in 51 (27.4%), and epicardial ablation in 6 (3.2%). At the beginning of the procedure, 258 of 744 PVs (35%) showed reconnections. Additional antral ablations were applied in 236 of 486 still isolated veins (49%). Posterior wall ablation was added in 125 patients (67%). Major complications occurred in 1 patient (transient ischemic attack 0.5%). Freedom from arrhythmia recurrence in Kaplan-Meier-analysis was 78% after 6 months and 54% after 12 months. Conclusion: PFA is a versatile and safe option for repeat procedures after failed prior thermal ablation.

3.
JACC Clin Electrophysiol ; 10(6): 1090-1100, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38639700

RESUMEN

BACKGROUND: Recurrence of paroxysmal atrial fibrillation (AF) following pulmonary vein isolation (PVI) is presumably caused by pulmonary vein (PV) reconnections. However, there is little data available on the durability of PVI and incidence of arrhythmia recurrence in patients with persistent AF. OBJECTIVES: The purpose of this study was to evaluate the lesion durability by means of an a priori planned remapping procedure in patients with persistent AF undergoing CLOSE-guided PVI. METHODS: In a prospective study, we included patients with symptomatic, persistent AF undergoing CLOSE-guided radiofrequency ablation. Irrespective of AF recurrence, a redo procedure was mandated 6 months following the index procedure to evaluate PV reconnections. The outcome of AF ablation was based on clinical recurrence and 7-day Holter electrocardiogram 3 and 6 months after the index procedure and 3, 6, and 12 months after the redo procedure. RESULTS: Of 30 patients included, 26 (81% men; median age 68 years) underwent the planned remapping study a median of 6 months after the index procedure, whereas 4 patients without recurrence refused a repeat procedure. In total, 78 of 102 (76%) PVs showed durable isolation and 15 patients (58%) presented complete isolation of all PVs. Beyond the blanking period, 6 of 26 patients (23%) had arrhythmia recurrence before the redo procedure. Recurrence had occurred in 33% of patients with complete isolation of all veins and in 9% of patients with PV reconnections (P = 0.197). After re-PVI in patients with PV reconnections and additional ablation in patients with recurrence but durable PVI, 17 of 26 patients (65%) were free of arrhythmia after 12 months. CONCLUSIONS: In patients with persistent AF, CLOSE-guided PVI resulted in durable rate of PVI on a per-vein and per-patient level of 76% and 58%, respectively. Arrhythmia recurrence was numerically higher in patients with durable PVI compared with patients without.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Venas Pulmonares/cirugía , Masculino , Femenino , Estudios Prospectivos , Anciano , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Resultado del Tratamiento , Electrocardiografía Ambulatoria , Reoperación/estadística & datos numéricos
4.
Heart Rhythm ; 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38614191

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) has shown promising data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI), with similar long-term outcomes compared to radiofrequency ablation (RFA) and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to compare the procedural and long-term outcomes in patients with persistent AF undergoing PVI using PFA, CBA, or RFA. METHODS: Consecutive patients with persistent AF undergoing first PVI with PFA, CBA, or RFA were included. Patients underwent 7-day Holter electrocardiography at 3, 6, and 12 months postablation. The primary outcome was recurrence of any atrial arrhythmia after a 90-day blanking period. Safety outcomes included the composite of in-hospital major adverse events. RESULTS: A total of 533 patients with persistent AF underwent PVI using PFA (n = 214, 39%), CBA (n = 190, 36%), or RFA (n = 129, 24%). Procedures with PFA guided by fluoroscopy were shorter than those with CBA (median 60 minutes; interquartile range [IQR] 53-80 minutes vs 84 minutes; IQR 68-101 minutes; P ≤ .001), and procedures with PFA in combination with 3-dimensional electroanatomic mapping were shorter than those with RFA (median 101 minutes; IQR 85-126 minutes vs 171 minutes; IQR 141-204 minutes; P < .001). Acute safety events occurred in 2.3%, 2.6%, and 0.8% in the PFA, CBA, and RFA groups, respectively (P = .545). The 1-year confounder-adjusted estimate for freedom from atrial arrhythmias was 62.1% for CBA, 55.3% for PFA, and 48.3% for RFA (CBA vs PFA: P = .79; CBA vs RFA: P = .009; PFA vs RFA: P = .010). CONCLUSION: In patients with persistent AF undergoing first PVI, 1-year confounder-adjusted outcomes are better with PFA and CBA than with RFA.

5.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38597211

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Femenino , Humanos , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Venas Pulmonares/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Fenotipo , Recurrencia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
6.
J Am Heart Assoc ; 13(4): e032223, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38348803

RESUMEN

BACKGROUND: Screening for atrial fibrillation (AF) may reveal incidental arrhythmias of relevance. The aim of this study was to describe incidental arrhythmias detected during screening for AF in the STAR-FIB (Predicting SilenT AtRial FIBrillation in Patients at High Thrombembolic Risk) cohort study. METHODS AND RESULTS: In the STAR-FIB cohort study, we screened hospitalized patients for AF with 3 repeat 7-day Holter ECGs. We analyzed all Holter ECGs for the presence of the following incidental arrhythmias: (1) sinus node dysfunction, defined as sinus pause of ≥3 seconds' duration; (2) second-degree (including Wenckebach) or higher-degree atrioventricular block (AVB); (3) sustained supraventricular tachycardia of ≥30 seconds' duration; and (4) sustained ventricular tachycardia of ≥30 seconds' duration. We furthermore report treatment decisions because of incidental arrhythmias. A total of 2077 Holter ECGs were performed in 794 patients (mean age, 74.7 years; 49% women), resulting in a mean cumulative duration of analyzable ECG signal of 414±136 hours/patient. We found incidental arrhythmias in 94 patients (11.8%). Among these were sinus node dysfunction in 14 patients (1.8%), AVB in 41 (5.2%), supraventricular tachycardia in 42 (5.3%), and ventricular tachycardia in 2 (0.3%). Second-degree AVB was found in 23 patients (2.9%), 2:1 AVB in 10 (1.3%), and complete AVB in 8 (1%). Subsequently, 8 patients underwent pacemaker implantation, 1 for sinus node dysfunction (post-AF conversion pause of 9 seconds) and 7 for advanced AVB. One patient had an implantable cardioverter-defibrillator implanted for syncopal ventricular tachycardia. CONCLUSIONS: Incidental arrhythmias were frequently detected during screening for AF in the STAR-FIB study and resulted in device therapy in 1.1% of our cohort patients.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Desfibriladores Implantables , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Femenino , Anciano , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Electrocardiografía Ambulatoria , Estudios de Cohortes , Síndrome del Seno Enfermo , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/terapia , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Hospitales
7.
J Interv Card Electrophysiol ; 67(3): 503-511, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37523023

RESUMEN

BACKGROUND: A novel multipolar pulsed-field ablation (PFA) catheter has recently been introduced for pulmonary vein isolation (PVI). Pre-market data showed high rates for PVI-durability during mandatory remapping studies. OBJECTIVE: To present post-market data in patients with recurrent arrhythmias. METHODS: Consecutive patients undergoing a redo procedure after an index PFA PVI using a bipolar-biphasic PFA system were included. 3-D electro-anatomical maps (3D-EAM) on redo procedure were compared to the 3D-EAM acquired after ablation during the index procedure. PVI durability was assessed on a per-vein and per-patient level and the sites of reconnections were identified. Furthermore, lesion extent around veins with durable isolation was compared to study lesion regression. RESULTS: Of 341 patients treated with a PFA PVI, 29 (8.5%) underwent a left atrial redo ablation due to arrhythmia recurrence. At the end of the index procedure, 110/112 veins (98%, four common ostia) were isolated. On redo procedures performed a median of 6 months after the first ablation, 3D-EAM identified 69/110 (63%) PVs with durable isolation. In 6 (21%) patients, all PVs were durably isolated. Reconnections were more often found on the right-sided veins and on the anterior aspects of the upper veins. Only minor lesion regression was observed between the index and redo procedure (a median of 3 mm (0 - 9.5) on the posterior wall). CONCLUSION: In patients with arrhythmia recurrence after PFA PVI using a first-generation PFA device, durable isolation was observed in 63% of the veins and 21% of the patients showed durable isolation of all previously isolated veins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Atrios Cardíacos/cirugía , Criocirugía/métodos , Reoperación/métodos , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
8.
J Interv Card Electrophysiol ; 67(2): 389-397, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37776355

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) has shown favourable data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI). We sought to compare procedural and 1-year follow-up data of patients with paroxysmal atrial fibrillation (AF) undergoing PVI using PFA, cryoballoon ablation (CBA) and radiofrequency ablation (RFA). METHODS: Consecutive patients with paroxysmal AF undergoing a first PVI with PFA at our institution were included. For comparison, patients with paroxysmal AF undergoing a first PVI with CBA and RFA were selected using a 1:2:2 propensity score matching. The PFA group followed the standard 32-applications lesion-set protocol, the CBA group a time-to-effect plus 2-min strategy, and the RFA group the CLOSE protocol. Patients were followed with 7d-Holter ECGs 3, 6, and 12 months after ablation. The primary endpoint was recurrence of atrial tachyarrhythmia (ATa) following a blanking period of 3 months. RESULTS: A total of 200 patients were included (PFA n = 40; CBA n = 80; RFA n = 80). Median procedure times were shortest with CBA (75 min) followed by PFA (94 min) and RFA (182 min; p < 0.001). Fluoroscopy dose was lowest with RFA (1.6Gycm2) followed by PFA (5.0Gycm2) and CBA (5.7Gycm2; p < 0.001). After a 1-year follow-up, freedom from ATa recurrence was 85.0% with PFA, 66.2% with CBA and 73.8% with RFA (p = 0.12 PFA vs. CBA; p = 0.27 PFA vs. RFA). CONCLUSION: In a propensity score matched analysis of patients with paroxysmal AF, freedom from any ATa 1 year after PVI using PFA was favourable and at least as good as for PVI with CBA or RFA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Ablación por Radiofrecuencia , Humanos , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Puntaje de Propensión , Resultado del Tratamiento , Criocirugía/métodos , Ablación por Catéter/métodos , Recurrencia
9.
Artículo en Inglés | MEDLINE | ID: mdl-37851866

RESUMEN

AIMS: Implantation of an implantable cardiac monitor (ICM) is a simple procedure, but adds significant and increasing workload to the arrhythmia service. In 2020, we established a nurse-led ICM implantation service. We aimed to analyze patient satisfaction, adverse events during implant and ICM re-interventions with nurse-led ICM implantation (N-Implant) compared to physician-led ICM implantation (P-Implant). METHOD AND RESULTS: From January 2020 to December 2021 we included all consecutive patients implanted with an ICM in a prospective registry. We collected data on patient characteristics, implant procedure and follow-up. Patients were interviewed by phone four weeks after ICM implantation.Of 321 patients implanted with an ICM (median age 67 years; 33% women), 189 (59%) were N-Implants. More N-Implants were performed in the outpatient clinic compared to P-Implants (95% vs. 8%; p<0.001). Two N-Implant patients experienced vaso-vagal reaction during implantation (1%), whereas no adverse events occurred during P-Implant (p=0.51). 297 patients (93%) completed the questionnaire. Duration of pain was shorter and wound closure after 2 weeks better following N-Implant (p=0.019 and p=0.018). A minor bruise or swelling at the implant site was reported more frequently after N-Implant (p=0.003 and p=0.041). Patient satisfaction was excellent with both N-Implant and P-Implant (99% and 97%; p=0.16). After a median follow-up of 242 days (range 7-725 days), five ICMs (2%) were explanted prematurely, without differences among groups. Reasons for premature explants were local discomfort (n=2), infection, MRI and ICM malfunction. CONCLUSION: Nurse-led ICM implantation has excellent patient satisfaction without compromising safety. N-Implant both expands nursing competencies and reduces physician workload.

10.
Europace ; 25(4): 1500-1502, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36892147

RESUMEN

AIMS: Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is generally performed using a standard transseptal sheath that is then exchanged over the wire for a dedicated PFA sheath, which might be a potential source for air embolism. We aimed to prospectively evaluate the feasibility and safety of a simplified workflow using the PFA sheath (Faradrive, Boston Scientific) directly for TSP. METHODS AND RESULTS: We prospectively enrolled 100 patients undergoing PVI using PFA at two centres. TSP was performed using the PFA sheath and a standard 98 cm transseptal needle under fluoroscopic guidance. TSP via the PFA sheath was successfully performed in all patients and no complications occurred. The median time from the first groin puncture to the completed LA access was 12 min (IQR 8-16 min). CONCLUSION: An over-the-needle TSP directly with the PFA sheath proved feasible and safe in our study. This simplified workflow has the potential to reduce the risk of air embolism, to shorten procedure time, and to reduce cost.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Embolia Aérea , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Embolia Aérea/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/cirugía , Punciones/métodos , Resultado del Tratamiento
11.
Europace ; 26(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38225174

RESUMEN

AIMS: The left atrial posterior wall is a potential ablation target in patients with recurrent atrial fibrillation despite durable pulmonary vein isolation or in patients with roof-dependent atrial tachycardia (AT). Pulsed-field ablation (PFA) offers efficient and safe posterior wall ablation (PWA), but available data are scarce. METHODS AND RESULTS: Consecutive patients undergoing PWA using PFA were included. Posterior wall ablation was performed using a pentaspline PFA catheter and verified by 3D-electroanatomical mapping. Follow-up was performed using 7-day Holter ECGs 3, 6, and 12 months after ablation. Recurrence of any atrial arrhythmia lasting more than 30 s was defined as failure. Lesion durability was assessed during redo procedures. Posterior wall ablation was performed in 215 patients (70% males, median age 70 [IQR 61-75] years, 67% redo procedures) and was successful in all patients (100%) by applying a median of 36 (IQR 32-44) PFA lesions. Severe adverse events were cardiac tamponade and vascular access complication in one patient each (0.9%). Median follow-up was 7.3 (IQR 5.0-11.8) months. One-year arrhythmia-free outcome in Kaplan-Meier analysis was 53%. A redo procedure was performed in 26 patients (12%) after a median of 6.9 (IQR 2.4-11) months and showed durable PWA in 22 patients (85%) with only minor lesion regression. Among four patients with posterior wall reconnection, three (75%) presented with roof-dependent AT. CONCLUSION: Posterior wall ablation with this pentaspline PFA catheter can be safely and efficiently performed with a high durability observed during redo procedures. The added value of durable PWA for the treatment of atrial fibrillation remains to be evaluated.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos , Venas Pulmonares/cirugía , Recurrencia
12.
J Clin Med ; 11(24)2022 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-36555877

RESUMEN

Conduction system pacing (CSP) encompassing His bundle (HBP) and left bundle branch area pacing (LBBAP) is gaining increasing attention in the electrophysiology community. These relatively novel physiological pacing modalities have the potential to outperform conventional pacing approaches with respect to clinical endpoints, although data are currently still limited. While HBP represents the most physiological form of cardiac stimulation, success rates, bundle branch correction, and electrical lead performance over time remain a concern. LBBAP systems may overcome these limitations. In this review article, we provide a comprehensive overview of the current evidence, implantation technique, device programming, and follow-up considerations concerning CSP systems. Moreover, we discuss ongoing technical developments and future perspectives of CSP.

13.
Europace ; 24(8): 1248-1255, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35699395

RESUMEN

AIMS: To validate the performance of a multipolar pulsed-field ablation (PFA) catheter compared to a standard pentaspline 3D-mapping catheter for endpoint assessment of pulmonary vein isolation (PVI). PFA for PVI using single-shot devices combines the benefits of high procedural efficacy and safety. A newly available multipolar PFA catheter allows real-time recording of pulmonary vein (PV) signals during PVI. METHODS AND RESULTS: Patients undergoing first PVI using PFA with the standard ablation protocol (eight applications per PV) were studied. Entrance and exit block (10 V/2 ms) were assessed using the PFA catheter. Subsequently, a high-density 3D electroanatomical bipolar voltage map (3D-EAM) was constructed using a standard pentaspline 3D-mapping catheter. Additional PFA applications were delivered only after confirmation of residual PV connection by 3D-EAM. In 56 patients, 213 PVs were targeted for ablation. Acute PVI was achieved in 100% of PVs: in 199/213 (93%) PVs with the standard ablation protocol alone and in the remaining 14 PVs after additional PFA applications. The accuracy of PV assessment with the PFA catheter after the standard ablation protocol was 91% (194/213 veins). In 5/213 (2.3%) PVs, the PFA catheter incorrectly indicated PV-isolation. In 14/213 (6.6%), the PFA catheter incorrectly indicated residual PV-conduction due to high-output pace-capture. Lowering the output to 5 V/1 ms reduced this observation to 0.9% (2/213) and increased the overall accuracy to 97% (206/213). CONCLUSION: A novel multipolar PFA catheter allows reliable endpoint assessment for PVI. Due to its design, far-field sensing and high-output pace-capture can occur. Lowering the pacing output increases the accuracy from 91 to 97%.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Catéteres , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento
14.
J Cardiovasc Electrophysiol ; 33(7): 1617-1627, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35614867

RESUMEN

INTRODUCTION: Conventional transvenous pacemaker leads may interfere with the tricuspid valve leaflets, tendinous chords, and papillary muscles, resulting in significant tricuspid valve regurgitation (TR). Leadless pacemakers (LLPMs) theoretically cause less mechanical interference with the tricuspid valve apparatus. However, data on TR after LLPM implantation are sparse and conflicting. Our goal was to investigate the prevalence of significant TR before and after LLPM implantation. METHODS: Patients who received a leadless LLPM (Micra™ TPS, Medtronic) between May 2016 and May 2021 at our center were included in this observational study if they had at least a pre- and postinterventional echocardiogram (TTE). The evolution of TR severity was assessed. Following a systematic literature review on TR evolution after implantation of a LLPM, data were pooled in a random-effects meta-analysis. RESULTS: We included 69 patients (median age 78 years [interquartile range (IQR) 72-84 years], 26% women). Follow-up duration between baseline and follow-up TTE was 11.4 months (IQR 3.5-20.1 months). At follow-up, overall TR severity was not different compared to baseline (p = .49). Six patients (9%) had new significant TR during follow-up after LLPM implantation, whereas TR severity improved in seven patients (10%). In the systematic review, we identified seven additional articles that investigated the prevalence of significant TR after LLPM implantation. The meta-analysis based on 297 patients failed to show a difference in significant TR before and after LLPM implantation (risk ratio 1.22, 95% confidence interval 0.97-1.53, p = .11). CONCLUSION: To date, there is no substantial evidence for a significant change in TR after implantation of a LLPM.


Asunto(s)
Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Humanos , Masculino , Estudios Observacionales como Asunto , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/epidemiología
16.
Praxis (Bern 1994) ; 106(25): 1405, 2017.
Artículo en Alemán | MEDLINE | ID: mdl-29231083
17.
Praxis (Bern 1994) ; 106(24): 1315-1322, 2017 11.
Artículo en Alemán | MEDLINE | ID: mdl-29183209

RESUMEN

Transient global amnesia (TGA) is a neurological condition which is still a diagnostic challenge for clinicians. Diagnostic clues are an acute onset of a disturbance of memory, a lack of other focal neurological deficits, and repetitive questioning of the patients about time and circumstances. Although the signs and symptoms are quite typical, making the diagnosis of TGA might still be challenging, depending on the patient's characteristics. Taking a precise history from the patient and his/her next of kin is seminal. This article discusses the typical clinical presentation, pathophysiological hypotheses, the diagnostic clues and the most important differential diagnoses.


Asunto(s)
Amnesia Global Transitoria , Diagnóstico Diferencial , Femenino , Humanos , Masculino
18.
Clin Biochem ; 48(4-5): 340-6, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25218814

RESUMEN

OBJECTIVES: The pathophysiological links between obstructive sleep apnea syndrome (OSAS) and cardiovascular mortality are incompletely understood. We aimed to contribute to a better characterization by using comprehensive biomarker profiling quantifying hemodynamic cardiac stress, cardiomyocyte injury, inflammation, endothelial function, matrix turnover and metabolism. DESIGN AND METHODS: In 65 patients with moderate or severe OSAS [apnea-hypopnea index (AHI) 39±20/h] and 33 patients with no or mild OSAS (AHI 8+4/h), B-type natriuretic peptide (BNP), N-terminal-pro-BNP (NT-proBNP), high-sensitivity cardiac troponin I (hs-cTnI), interleukin-6 (IL-6), vascular endothelial growth factor (VEGF), matrix metalloproteinase-9 (MMP-9), and insulin were measured before and after sleep. In a subgroup measurements were repeated in a second night with continuous positive airway pressure (CPAP). RESULTS: Patients with moderate/severe OSAS had higher insulin before sleep [median (interquartile range), 36.4 (21.9-52.1) vs. 20.8 (10.6-32.8)mU/mL; p=0.006], higher IL-6 after sleep [1.00 (0.73-1.58) vs. 0.72 (0.48-0.94)pg/mL; p=0.005], and larger relative overnight reduction in BNP [-9 (-35-0) vs. -3 (-21-13)%; p=0.04] than those with mild/no OSAS. Insulin before sleep was the only independent predictor of moderate/severe OSAS. Insulin before and IL-6 after sleep were independent predictors of severe OSAS, and when combined provided high diagnostic accuracy for severe OSAS (area under the receiver operator characteristic curve 0.80; 95%-confidence interval 0.69-0.91). In contrast, there were no significant differences in NT-proBNP, hs-cTnI, VEGF, and MMP-9 between moderate/severe and mild/no OSAS. Short-term CPAP had no impact on biomarker concentrations before and after sleep. CONCLUSIONS: Significant OSAS is characterized by a distinct biomarker profile including high insulin before and high IL-6 after sleep.


Asunto(s)
Insulina/sangre , Interleucina-6/sangre , Apnea Obstructiva del Sueño/sangre , Apnea Obstructiva del Sueño/diagnóstico , Adulto , Anciano , Biomarcadores/sangre , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía/métodos , Estudios Prospectivos , Factor A de Crecimiento Endotelial Vascular/sangre
19.
J Card Fail ; 19(12): 821-8, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24239955

RESUMEN

BACKGROUND: Biomarkers may help to monitor and tailor treatment in patients with acute heart failure (AHF). METHODS AND RESULTS: Levels of ST2, a novel biomarker integrating hypervolemic cardiac strain and proinflammatory signals, were measured at presentation to the emergency department (ED) and after 48 hours in 207 patients with AHF. Patients were stratified according to their early ST2 response (responders: ST2 decrease ≥25%; nonresponders: ST2 decrease <25%) and beta-blocker, renin-angiotensin-aldosterone system (RAAS) blockade, or diuretic treatment status at hospital discharge. We assessed the utility of ST2 levels and its changes to predict long-term mortality and the interaction between ST2 levels, treatment at discharge, and 1-year mortality. ST2 levels were higher in nonsurvivors than in survivors (median 108 vs 69 ng/mL; P < .01) and decreased significantly during the 1st 48 hours (median decrease 33%). ST2 decrease was less in nonsurvivors compared with survivors (median -25% vs -42%; P < .01). In Cox regression, early ST2 changes independently predicted 1-year mortality (hazard ratio 1.07 for every increase of 10%; P = .02). RAAS blockers at discharge were associated with survival independently from ST2 response, whereas the association of beta-blockers with survival differed markedly according to ST2 response, with beneficial effects restricted to ST2 nonresponders (P interaction = .04). A similar, albeit nonsignificant, trend was observed for diuretics (P interaction = .11). CONCLUSIONS: ED and serial ST2 measurements are independent predictors of 1-year mortality in AHF.


Asunto(s)
Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/diagnóstico , Guías de Práctica Clínica como Asunto/normas , Receptores de Superficie Celular/sangre , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Estudios de Cohortes , Diagnóstico Precoz , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/terapia , Humanos , Proteína 1 Similar al Receptor de Interleucina-1 , Masculino , Valor Predictivo de las Pruebas , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...