Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Pharm ; 84(2): 347-59, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27222609

RESUMEN

Efficacy assessments using a combination of baricitinib and methotrexate necessitate the development of an analytical method for the determination of both drugs in plasma with precision. A high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of baricitinib and methotrexate in rat plasma. Extraction of baricitinib, methotrexate, and tolbutamide (internal standard; IS) from 50 µL of rat plasma was carried out by protein precipitation with methanol. Chromatographic separation of the analytes was performed on the YMC pack ODS AM (150 mm × 4.6 mm, 5 µm) column under gradient conditions with methanol: 2.0 mM ammonium acetate buffer as the mobile phases at a flow rate of 1 mL/min. The precursor ion and product ion transition for both analytes and IS were monitored on a triple quadrupole mass spectrometer, operated with selective reaction monitoring in positive ionization mode. The method was validated over a concentration range of 0.5-250.00 ng/mL for baricitinib and methotrexate. Mean extraction recoveries for baricitinib, methotrexate, and IS of 86.8%, 89.4%, and 91.8% were consistent across low, medium, and high QC levels, respectively. Precision and accuracy at low, medium, and high quality control levels were less than 15% across the analytes. Benchtop, wet, freeze-thaw, and long-term stability were evaluated for both of the analytes. The analytical method was applied to support the pharmacokinetic study of simultaneous estimation of baricitinib and methotrexate in Wistar rats. Assay reproducibility was demonstrated by reanalysis of 18 incurred samples.

2.
Sci Pharm ; 80(3): 633-46, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23008811

RESUMEN

A new method for the simultaneous determination of celecoxib, erlotinib, and its active metabolite desmethyl-erlotinib (OSI-420) in rat plasma, by liquid chromatography/tandem mass spectrometry with positive/negative ion-switching electrospray ionization mode, was developed and validated. Protein precipitation with methanol was selected as the method for preparing the samples. The analytes were separated on a reverse-phase C(18) column (50mm×4.6mm i.d., 3µ) using methanol: 2 mM ammonium acetate buffer, and pH 4.0 as the mobile phase at a flow rate 0.8 mL/min. Sitagliptin and Efervirenz were used as the internal standards for quantification. The determination was carried out on a Theremo Finnigan Quantam ultra triple-quadrupole mass spectrometer, operated in selected reaction monitoring (SRM) mode using the following transitions monitored simultaneously: positive m/z 394.5→278.1 for erlotinib, m/z 380.3→278.1 for desmethyl erlotinib (OSI-420), and negative m/z -380.1→ -316.3 for celecoxib. The limits of quantification (LOQs) were 1.5 ng/mL for Celecoxib, erlotinib, and OSI-420. Within- and between-day accuracy and precision of the validated method were within the acceptable limits of < 15% at all concentrations. The quantitation method was successfully applied for the simultaneous estimation of celecoxib, erlotinib, and desmethyl erlotinib in a pharmacokinetic study in Wistar rats.

3.
J Mass Spectrom ; 47(12): 1612-9, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23280750

RESUMEN

A sensitive and reliable high-performance liquid chromatography-mass spectrometry (LC-MS/MS) was developed and validated for simultaneous quantification IC87114, roflumilast (RFM), and its active metabolite roflumilast N-oxide (RFN) using tolbutamide as an internal standard. The analytes were extracted by using liquid-liquid extraction and separated on a reverse phase C(18) column (50 mm × 3 mm i.d., 4.6 µ) using methanol: 2 mM ammonium acetate buffer, pH 4.0 as mobile phase at a flow rate 1 mL/min in gradient mode. Selective reaction monitoring was performed using the transitions m/z 398.3 > 145.9, 403.1 >186.9, 419.1 > 187.0 and 271.1 > 155.0 to quantify quantification IC87114, RFM, RFN and tolbutamide, respectively. The method was validated over the concentration range of 0.1-60 ng.mL(-1) for RFM and RFN and 6 to 2980 ng.mL(-1) for IC87114. Intra- and inter-day accuracy and precision of validated method were within the acceptable limits of <15% at all concentrations. Coefficients of correlation (r(2) ) for the calibration curves were >0.99 for all analytes. The quantitation method was successfully applied for simultaneous estimation of IC87114, RFM and RFN in a pharmacokinetic drug-drug interaction study in Wistar rats.


Asunto(s)
Adenina/análogos & derivados , Aminopiridinas/sangre , Benzamidas/sangre , Cromatografía Líquida de Alta Presión/métodos , Quinazolinas/sangre , Espectrometría de Masas en Tándem/métodos , Adenina/sangre , Adenina/química , Adenina/farmacocinética , Aminopiridinas/química , Aminopiridinas/farmacocinética , Animales , Benzamidas/química , Benzamidas/farmacocinética , Ciclopropanos/sangre , Ciclopropanos/química , Ciclopropanos/farmacocinética , Estabilidad de Medicamentos , Modelos Lineales , Masculino , Quinazolinas/química , Quinazolinas/farmacocinética , Ratas , Ratas Wistar , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA